FA12S20-300TH [WALL]

Operation to No Load;
FA12S20-300TH
型号: FA12S20-300TH
厂家: WALL INDUSTRIES,INC.    WALL INDUSTRIES,INC.
描述:

Operation to No Load

文件: 总4页 (文件大小:180K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
FA Series  
250-300 Watt  
Single Output  
Rev D  
Full Brick DC/DC Converter  
FEATURES  
100% Burn In  
Synchronizable  
Output Trim ±10%  
1500VDC Isolation  
Operation to No Load  
Very Low Output Ripple  
Output Current up to 60A  
Fast Transient Response  
Fixed Switching Frequency  
250-300 Watts Output Power  
Remote Sense Compensation  
Remote ON/OFF (Active High/Low)  
Short Circuit and Over Temperature Protection  
90% Efficient at Half Load, 88% Efficient at Full Load  
DESCRIPTION  
The FA series is a high-density full brick converter that  
incorporates the desired features required in today’s  
demanding low voltage bus applications. Its unique dual  
interleaved phase-shifted topology minimizes both input  
and output noise. When performance, reliability, and low  
cost are needed, the FA series delivers.  
Optional Chassis Mount Version Available (See CMFA Series)  
SPECIFICATIONS: FA Series  
All specifications apply @ 25°C ambient unless otherwise noted  
INPUT SPECIFICATIONS  
PROTECTION SPECIFICATIONS  
Input Voltage Range .................................................................. 10-36VDC  
UVLO Turn On at.....................................................................10VDC max  
UVLO Turn off at.....................................................................9.5VDC max  
Input Filter................................1,000μF low ESR capacitor recommended  
Input Surge Voltage (100ms)...........................................................50VDC  
Reflected Ripple Current (nominal Vin and full load).........................20mA  
Remote ON/OFF.................................................See Technical Datasheet  
Input Current under Remote Off ..........................................................1mA  
Maximum Input Current (Low Line).......................................................35A  
No Load Input Current .........................................................................0.1A  
Current Limit........................................................................................ 130%  
Short Circuit Protection........................................Continuous, self re-setting  
Over Temperature Protection......................................110°C, self re-setting  
GENERAL SPECIFICATIONS  
Efficiency ....................................................................................90% typical  
Switching Frequency .................................................................700KHz typ.  
Isolation Voltage (Input to Output).........................................1500VDC min.  
Isolation Resistance ...................................................................... 1Gmin.  
Isolation Capacitance ........................................................................ 0.01μF  
ENVIRONMENTAL SPECIFICATIONS  
OUTPUT SPECIFICATIONS  
Operating Temperature (ambient)........................... -40°C ~ +100°C (case)  
Storage Temperature ..........................................................-55°C ~ +125°C  
Humidity...................................................................fully potted construction  
Cooling ..........................................................heatsink optional (see Note 4)  
MTBF.................................................................................. 2,212,456 hours  
Output Voltage..............................................................................see table  
Voltage Accuracy................................................................................. ±1%  
Output Adjustability............................................................................ ±10%  
Output Current ..............................................................................see table  
Output Power................................................................................see table  
Line Regulation (LL to HL at FL)....................................................... ±0.2%  
Load Regulation (NL to FL)............................................................... ±0.2%  
Ripple/Noise (20 MHz BW)....................................................1% Vout max  
Temperature Coefficient ................................................. ±0.02% / °C max.  
Transient Response (50% load step)..............................5% total deviation  
PHYSICAL SPECIFICATIONS  
Weight ................................................................................. 11.22oz (318g)  
Dimensions.............................................................. 4.6 x 2.4 x 0.50 inches  
Case Material .......................................................................Aluminum alloy  
Shielding......................................................................................... six-sided  
Due to advances in technology, specifications subject to change without notice  
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833  
603-778-2300 www.wallindustries.com Fax 603-778-9797  
06/29/2010  
Page 1 of 4  
FA Series  
250-300 Watt  
Single Output  
Rev D  
Full Brick DC/DC Converter  
MODEL SELECTION TABLE  
Model Number for  
Threaded Inserts  
Model Number for  
Thru-Hole Inserts  
Input Voltage Range  
Output Voltage  
Output Current  
Output Power  
FA12S43-250  
FA12S48-250  
FA12S5-300  
FA12S12-300  
FA12S15-300  
FA12S20-300  
FA12S24-300  
FA12S26-300  
FA12S28-300  
FA12S43-250TH  
FA12S48-250TH  
FA12S5-300TH  
FA12S12-300TH  
FA12S15-300TH  
FA12S20-300TH  
FA12S24-300TH  
FA12S26-300TH  
FA12S28-300TH  
43 VDC  
48 VDC  
5 VDC  
5.814A  
5.208A  
60A  
250W  
250W  
300W  
300W  
300W  
300W  
300W  
300W  
300W  
12 VDC  
15 VDC  
20 VDC  
24 VDC  
26 VDC  
28 VDC  
25A  
12 VDC  
20A  
(10 - 36 VDC)  
15A  
12.5A  
11.538A  
10.714A  
NOTES  
1. Pin to pin tolerance ± 0.01" [±0.3mm]. Pin diameter tolerance ±0.005" [±0.13mm].  
2. Case material: 0.040" [1.02mm] thick, aluminum alloy 3003-0, Per: QQA 250/2.  
3. Unit comes with either 3M x 0.5 threaded thru inserts or for 0.125 thru-hole add "TH" suffix to the model part  
number. Ex: FA12S24-300TH.  
4. For Heat sink add “HS” suffix to the model part number. Ex: FA12S24-300HS.  
5. Active High Enable is standard; for Active Low Enable add “R” suffix to the model number. Ex: FA12S24-300R.  
6. See CMFA Series for chassis mount version.  
DERATING CURVE  
FA12S24-300 MAX AMBIENT vs OUTPUT POWER  
Airflow across unit in linear  
feet per minute (LFM)  
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833  
06/29/2010  
603-778-2300 www.wallindustries.com Fax 603-778-9797  
Page 2 of 4  
FA Series  
250-300 Watt  
Single Output  
Rev D  
Full Brick DC/DC Converter  
MECHANICAL DRAWING  
Unit: inches [mm]  
HEATSINK SUPPLIED ATTACHED WITH  
THERMAL INTERFACE MATERIAL.  
HEATSINK HAS  
Ø.120±.005 Ø3.05±0.13 THRU HOLE 6X  
.02 [0.4] 6X REF  
COVER TO STANDOFF  
.84±.04 [21.3±1.0]  
HEATSINK  
TO STANDOFFS ONLY  
SEE NOTE 5  
.20 MIN [5.1 MIN]  
SEE NOTE-1&3  
PIN LENGTH FROM  
STANDOFFS ONLY  
.015 [0.38]  
.02 [0.4] 6X REF  
COVER TO STANDOFF  
STANDARD  
+.03  
.50  
+0.8  
-0.0  
12.7  
-.00  
TO STANDOFFS ONLY  
.20 MIN [5.1 MIN]  
SEE NOTE-1&3  
PIN LENGTH FROM  
STANDOFFS ONLY  
+.02  
.30  
+0.5  
7.6  
SEE NOTE-4  
3.600 [91.44]  
-.03  
-0.6  
LABEL  
SERIAL NO:  
1.800 [45.72]  
.50 [12.7]  
DOT DENOTES  
PIN-1  
.35 [8.9]  
.000 [0.00]  
1
6
7
.400 [10.16]  
.700 [17.78]  
1.000 [25.40]  
2
3
4
8
9
1.400 [35.56]  
5
DATE CODE  
4.200 [106.68]  
PIN DESIGNATION  
PIN Ø  
+.02  
-.03  
+0.5  
117.0  
-0.8  
1
2
3
4
5
6
7
8
9
+OUT  
+SENSE  
TRIM  
-SENSE  
-OUT  
+IN  
SD  
SYNC  
-IN  
Ø.081 [2.06]  
Ø.040 [1.02]  
Ø.040 [1.02]  
Ø.040 [1.02]  
Ø.081 [2.06]  
Ø.081 [2.06]  
Ø.040 [1.02]  
Ø.040 [1.02]  
Ø.081 [2.06]  
4.60  
NONMETALLIC INSULATOR 2X  
TO ORDER:  
NOTES:  
4. UNIT COMES WITH EITHER 3M x 0.5 THREADED  
THRU INSERTS OR FOR Ø.125 THRU-HOLE ADD:  
“TH” SUFFIX TO MODEL PART NUMBER.  
EXAMPLE: FA12S24-300TH  
1. PIN TO PIN TOLERANCE ± .01 [±0.3],  
PIN DIAMETER TOLERANCE: ±.005 [±0.13].  
2. CASE MATERIAL: .040 [1.02] THICK, ALUMINUM ALLOY 3003-0,  
PER: QQA 250/2.  
5. FOR HEAT SINK ADD: “HS” SUFFIX TO MODEL  
PART NUMBER. EXAMPLE: FA12S24-300HS.  
6. OPTIONAL CHASSIS MOUNT VERSION  
AVAILABLE (SEE CMFA SERIES).  
3. UNLESS OTHERWISE SPECIFIED.  
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833  
603-778-2300 www.wallindustries.com Fax 603-778-9797  
06/29/2010  
Page 3 of 4  
FA Series  
250-300 Watt  
Single Output  
Rev D  
Full Brick DC/DC Converter  
OPTIONAL CHASSIS MOUNT VERSION (SEE CMFA SERIES)  
Unit: inches [mm]  
8.00 [203.2]  
7.000 [177.80]  
3.500 [88.90]  
.50 [12.7]  
+INPUT  
+OUTPUT  
+S  
SD  
3.40 [86.4]  
2.875 [73.03]  
TRIM  
-S  
SYNC  
-INPUT  
-OUTPUT  
.000 [0.00]  
DATE CODE  
LABEL  
SERIAL NO:  
UNIT THRU HOLE Ø.125 [3.2] 6X REF  
PCB THRU HOLE Ø.140 [3.6] 6X REF  
Ø.143 [3.6] MOUNTING HOLES 6X  
GROUNDED 6-PLACES  
TERMINAL SCREW .136 (NO:6)-32UNC 9X  
.000 [0.00]  
Ø.28 [7.1] 6X  
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833  
603-778-2300 www.wallindustries.com Fax 603-778-9797  
06/29/2010  
Page 4 of 4  

相关型号:

FA12S24-300

Operation to No Load
WALL

FA12S24-300TH

Operation to No Load
WALL

FA12S26-300

Operation to No Load
WALL

FA12S26-300TH

Operation to No Load
WALL

FA12S28-300

Operation to No Load
WALL

FA12S28-300TH

Operation to No Load
WALL

FA12S43-250

Operation to No Load
WALL

FA12S43-250TH

Operation to No Load
WALL

FA12S48-250

Operation to No Load
WALL

FA12S48-250TH

Operation to No Load
WALL

FA12S5-300

Analog Circuit,
WALL

FA12S5-300R

Analog Circuit,
WALL