LANC2412UW8S [WALL]
DC-DC Regulated Power Supply Module, 1 Output, 8W, Hybrid, ROHS COMPLIANT, PLASTIC, SMT-24/18;型号: | LANC2412UW8S |
厂家: | WALL INDUSTRIES,INC. |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 8W, Hybrid, ROHS COMPLIANT, PLASTIC, SMT-24/18 光电二极管 |
文件: | 总5页 (文件大小:230K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DATASHEET
Rev. D
LANCUW8 SERIES
4:1 Ultra Wide Input Voltage Ranges
Single and Dual Outputs
SMT and DIP Packages
8 Watt DC/DC Power Converters
FEATURES
Single and Dual Outputs
4:1 Ultra Wide Input Voltage Ranges
High Efficiency up to 88%
8 Watts Output Power
1600VDC I/O Isolation
Output Current up to 2.4A
Remote ON/OFF
Fixed Switching Frequency (300KHz)
Over Voltage, Over Load, and Short Circuit Protection
Five-Sided Continuous Shield
APPLICATIONS
Railway Applications
Railway Systems
Standard 1.25” x 0.80” x 0.40” and 24 Pin DIP Package
SMT Package Available (Suffix “S”)
Wireless Networks
Telecom / Datacom
Measurement Equipment
Industry Control Systems
Semiconductor Equipment
Compliant to RoHS EU Directive 2002/95/EC
CE Mark Meets 2006/95/EC, 93/68/EEC and 2004/108/EC
UL60950-1, EN60950-1, IEC60950-1, and EN50155 Safety
Approvals (Pending)
DESCRIPTION
The LANCUW8 series of DC/DC power converters provides 8 Watts of output power in a 1.25 x 0.80 x 0.40 inch DIP
package. This series has single and dual output models with 4:1 wide input voltage ranges of 9-36VDC, 18-75VDC, and
43-160VDC. Some features include high efficiency up to 88%, 1600VDC I/O isolation, five-sided shielding, remote
ON/OFF control, and no minimum load requirement. These converters are also protected against over voltage (single
outputs only), over load, and short circuit conditions. All models are RoHS compliant and have UL60950-1, EN60950-1,
IEC60950-1, and EN50155 safety approvals (pending). This series is best suited for use in wireless networks,
telecom/datacom, measurement equipment, industry control systems, semiconductor equipment, and railway systems.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
03/15/2011
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 1 of 5
LANCUW8 Series
Single & Dual Outputs
4:1 Input Voltage Range
Rev. D
8 Watt DC/DC Power Converters
SPECIFICATIONS: LANCUW8 Series
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT SPECIFICATIONS
TEST CONDITIONS
Min
Nom
Max
Unit
VDC
VDC
VDC
24VDC nominal input models
9
18
43
24
48
110
36
75
160
50
100
170
9
Input Voltage Range
Input Surge Voltage (100ms max)
Start-Up Voltage
48VDC nominal input models
110VDC nominal input models
24VDC nominal input models
48VDC nominal input models
110VDC nominal input models
24VDC nominal input models
48VDC nominal input models
110VDC nominal input models
24VDC nominal input models
48VDC nominal input models
110VDC nominal input models
Nominal Vin and full load
18
43
8
Shutdown Voltage
VDC
16
42
20
Input Reflected Ripple Current
mAp-p
DC/DC ON
DC/DC OFF
Open or 3.0V < Vr < 12V
Short or 0V < Vr < 1.2V
Remote ON/OFF (See Note 6)
Input Current of Remote Control Pin
Remote Off State Input Current
Input Filter
Nominal Vin
Nominal Vin
-0.5
+0.5
mA
mA
2.5
Pi type
OUTPUT SPECIFICATIONS
Output Voltage
See Table
Line Regulation
Low line to high line at full load
No load to full load
-0.2
-0.5
-1
+0.2
+0.5
+1
+1
+0.3
+0.8
+0.8
+5
%
%
Single Output (DIP)
Single Output (SMT)
Dual Output (DIP & SMT)
Single Output (DIP)
Single Output (SMT)
Dual Output (DIP & SMT)
-1
Load Regulation
-0.3
-0.8
-0.8
-5
10% load to 90% load
%
Cross Regulation (Dual Outputs)
Voltage Accuracy
Output Power
Output Current
Ripple & Noise
Asymmetrical load 25% / 100% full load
Full load an nominal Vin
%
%
W
-1
+1
8
See Table
See Table
250
20MHz Bandwidth
25% load step change
Nom. Vin and constant resistive load
Transient Response Recovery Time
Start-Up Time
µs
ms
Power Up
450
Minimum Load
0
%
Temperature Coefficient
PROTECTION
-0.02
+0.02
%/°C
Over Load Protection
Short Circuit Protection
% of full load at nominal input
150
%
Continuous, automatic recovery
3.3V output model
5.0V output model
12V output model
15V output model
3.9
6.2
15
Over Voltage Protection
(Single Outputs only)
VDC
18
GENERAL SPECIFICATIONS
Efficiency
Switching Frequency
Nominal Vin and full load
See Table
300
KHz
Input to Output (DIP & SMT)
Input (Output) to Case (DIP)
Input (Output) to Case (SMT)
1600
1600
1000
10
Isolation Voltage
VDC
Isolation Resistance
Isolation Capacitance
GΩ
pF
1500
ENVIRONMENTAL SPECIFICATIONS
without derating
with derating
without derating
with derating
-40
+78
-40
+78
+105
+70
+105
5V, 12V, 15V, ±12V, & ±15V output models
3.3V and ±5V output models
°C
°C
Operating Ambient Temperature (See Note 7)
+70
Maximum Case Temperature
Storage Temperature
Relative Humidity
Thermal Shock
Vibration
Thermal Impedance
+105
+125
95
°C
°C
% RH
-55
5
EN61373, MIL-STD-810F
EN61373, MIL-STD-810F
20
Natural Convection
°C/Watt
BELLCORE TR-NWT-000332
MIL-HDBK-217F
2,350,000 hours
1,078,000 hours
MTBF (See Note 1)
PHYSICAL SPECIFICATIONS
Weight
Case Material
Base Material
Potting Material
0.62oz (18g)
Nickel-coated copper
Non-conductive black plastic
Epoxy (UL94-V0)
Dimensions (L x W x H)
SAFETY & EMC CHARACTERISTICS
Safety Approvals (Pending)
EMI (See Note 8)
1.25 x 0.80 x 0.40 inches (31.8 x 20.3 x 10.2 mm)
IEC60950-1, UL60950-1, EN60950-1, EN50155
Class A
EN55022, EN55011
EN61000-4-2
Air
Contact
±8KV
ESD
Perf. Criteria A
±6KV
20 V/m
±2KV
±2KV
10 Vrms
Radiated Immunity
Fast Transient (See Note 9)
Surge (See Note 9)
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Conducted Immunity
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
03/15/2011
Page 2 of 5
LANCUW8 Series
Single & Dual Outputs
4:1 Input Voltage Range
Rev. D
8 Watt DC/DC Power Converters
MODEL SELECTION TABLES
SINGLE OUTPUT MODELS
Output Current
Input Current
Input Voltage
Range
Output
Voltage
Output (4)
Ripple & Noise
Output
Maximum (5)
Capacitive Load
Model Number
Efficiency (4)
Min. Load Full Load No Load (3) Full Load (2)
Power
8W
8W
8W
8W
8W
8W
8W
8W
8W
8W
8W
8W
LANC2433UW8
LANC2405UW8
LANC2412UW8
LANC2415UW8
LANC4833UW8
LANC4805UW8
LANC4812UW8
LANC4815UW8
LANC11033UW8
LANC11005UW8
LANC11012UW8
LANC11015UW8
3.3 VDC
5 VDC
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
2400mA
1600mA
666mA
533mA
2400mA
1600mA
666mA
533mA
2400mA
1600mA
666mA
533mA
40mA
40mA
25mA
25mA
20mA
20mA
13mA
13mA
8mA
407mA
402mA
407mA
407mA
204mA
201mA
201mA
198mA
82mA
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
75mVp-p
75mVp-p
75mVp-p
75mVp-p
85%
87%
86%
86%
85%
87%
87%
88%
84%
85%
86%
86%
1330μF
1330μF
288μF
24 VDC
(9 - 36 VDC)
12 VDC
15 VDC
3.3 VDC
5 VDC
200μF
1330μF
1330μF
288μF
200μF
1330μF
1330μF
288μF
200μF
48 VDC
(18 - 75 VDC)
12 VDC
15 VDC
3.3 VDC
5 VDC
110 VDC
8mA
90mA
(43 - 160 VDC)
12 VDC
15 VDC
4mA
88mA
4mA
88mA
DUAL OUTPUT MODELS
Input Voltage
Range
Output
Voltage
Output (6)
Ripple & Noise
Output
Power
Maximum (5)
Capacitive Load
Output Current
Input Current
Model Number
Efficiency (4)
Min. Load Full Load No Load (3) Full Load (2)
LANC2405DUW8
LANC2412DUW8
LANC2415DUW8
LANC4805DUW8
LANC4812DUW8
LANC4815DUW8
LANC11005DUW8
LANC11012DUW8
LANC11015DUW8
±5 VDC
±12 VDC
±15 VDC
±5 VDC
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
±800mA
±333mA
±267mA
±800mA
±333mA
±267mA
±800mA
±333mA
±267mA
20mA
25mA
25mA
10mA
13mA
13mA
5mA
417mA
407mA
407mA
208mA
201mA
201mA
93mA
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
50mVp-p
75mVp-p
75mVp-p
75mVp-p
8W
8W
8W
8W
8W
8W
8W
8W
8W
84%
86%
86%
84%
87%
87%
82%
85%
85%
±900µF
±133µF
±90µF
24 VDC
(9 - 36 VDC)
±900µF
±133µF
±90µF
48 VDC
±12 VDC
±15 VDC
±5 VDC
(18 - 75 VDC)
±900µF
±133µF
±90µF
110 VDC
±12 VDC
±15 VDC
5mA
90mA
(43 - 160 VDC)
5mA
90mA
NOTES
1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40°C.
MIL-HDBK-217F Notice2 @Ta=25°C, Full load (Ground, Benign, controlled environment).
2. Maximum value at nominal input voltage and full load.
3. Typical value at nominal input voltage and no load.
4. Typical value at nominal input voltage and full load.
5. Test by minimum Vin and constant resistive load.
6. The ON/OFF control pin voltage is referenced to -Vin.
7. Operating Ambient Temperature:
Converters can meet the railway T2 and TX temperature requirements.
T2: -40°C to +70°C for all models, TX: -40°C to +85°C with power derating to 55% output power.
8. The LANCUW8 series can meet EN55022 and EN55011 Class A with an external capacitor on the input pins to the converter.
Recommended: 24Vin Models: 1µF/50V 1210 MLCC
48Vin Models: 0.47µF/100V 1812 MLCC
110Vin Models: 1µF/250V*2pcs 1812 MLCC
9. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
Recommended: 24Vin & 48Vin Models: Nippon chemi-con KY series, 220µF/100V, ESR 48MΩ
110Vin Models: Nippon chemi-con KXJ series, 150µF/200V, ESR
10.For surface mount (SMT) type add the suffix “S” to the model number. Ex: LANC2405UW8S.
11.CAUTION: This power module is not internally fused. An input line fuse must always be used.
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
03/15/2011
603-778-2300 www.wallindustries.com Fax 603-778-9797
Page 3 of 5
LANCUW8 Series
Single & Dual Outputs
4:1 Input Voltage Range
Rev. D
8 Watt DC/DC Power Converters
LANC4805UW8 DERATING CURVE
120
100
80
60
40
20
0
81
-40
-20
0
20
40
60
80
100
120
AMBIENT TEMPERATURE (°C)
LANC4805UW8
LANC4805UW8
EFFICIENCY VS OUTPUT LOAD
EFFICIENCY VS INPUT VOLTAGE
95
90
85
80
75
70
65
95
90
85
80
75
70
65
18
24
30
36
42
48
54
60
66
72
75
10
20
30
40
50
60
70
80
90
100
INPUT VOLTAGE (V)
OUTPUT LOAD (% OF FULL LOAD)
Recommended Filter for EN55022 Class B Compliance
Recommended EN55022 Class B Filter Circuit Layout
LANCUW8
SERIES
The components used in the figure above are as follows:
C1
C2
C3
C4
L1
4.7µF/50V
1812 MLCC
1000pF/2KV 1000pF/2KV 325µH Common
MLCC MLCC Choke PMT-050
LANC24xxUW8
LANC48xxUW8
LANC110xxUW8
N/A
1.5µF/100V
1812 MLCC 1812 MLCC
1.5µF/100V 1000pF/2KV 1000pF/2KV 325µH Common
MLCC MLCC Choke PMT-050
4.7µF/250V 4.7µF/250V 1000pF/2KV 1000pF/2KV 325µH Common
1812 MLCC 1812 MLCC MLCC MLCC Choke PMT-050
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
03/15/2011
Page 4 of 5
LANCUW8 Series
Single & Dual Outputs
4:1 Input Voltage Range
Rev. D
8 Watt DC/DC Power Converters
MECHANICAL DRAWING
DIP TYPE
SMT TYPE
(add Suffix “S”)
Unit: inches (mm)
Unit: inches (mm)
Pin size is 0.02 (0.5) Dia or
0.01 x 0.02 (0.25 x 0.50) Rectangular Pin
0.44 (11.2)
0.43 (10.9)
1.00 (25.4)
0.90 (22.9)
1
2
3
24
20
16
1
23
22
5
BOTTOM
BOTTOM
VIEW
VIEW
9
16
14
9
11
13
12
Pin Area
0.04 x 0.02
(1.0 x 0.5)
0.80 (20.3)
0.600 (15.24)
0.80 (20.3)
0.40 (10.2)
0.15 (3.8)
1. Tolerance: X.XX±0.02 (X.X±0.5)
X.XXX±0.01 (X.XX±0.25)
2. Pin pitch tolerance ±0.01 (0.25)
(DIP) PIN CONNECTION
(SMT) PIN CONNECTION
PIN
1
SINGLE
CTRL
DUAL
PIN
SINGLE
DUAL
PIN
SINGLE
CTRL
DUAL
PIN
SINGLE
DUAL
CTRL
1
CTRL
2
-INPUT
-INPUT
-INPUT
-INPUT
23
22
+INPUT
+INPUT
+INPUT
+INPUT
2
3
-INPUT
-INPUT
-INPUT
-INPUT
23
22
+INPUT
+INPUT
+INPUT
+INPUT
3
9
NC
NC
COMMON
-OUTPUT
16
14
-OUTPUT
+OUTPUT
COMMON
+OUTPUT
9
NC
NC
NC
COMMON
-OUTPUT
NC
16
14
-OUTPUT
+OUTPUT
NC
COMMON
+OUTPUT
NC
11
11
Others
Others
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will
provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one
example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its
customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for
your project above and beyond the design and production phases. Give us a call today to discuss your future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
(603)778-2300
(888)587-9255
(603)778-9797
E-mail:
Web:
Address:
sales@wallindustries.com
www.wallindustries.com
5 Watson Brook Rd.
Exeter, NH 03833
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833
603-778-2300 www.wallindustries.com Fax 603-778-9797
03/15/2011
Page 5 of 5
相关型号:
©2020 ICPDF网 联系我们和版权申明