LANE6KV_16 [WALL]
1 Watt Medical & Industrial DC/DC Power Converters;型号: | LANE6KV_16 |
厂家: | WALL INDUSTRIES,INC. |
描述: | 1 Watt Medical & Industrial DC/DC Power Converters |
文件: | 总5页 (文件大小:513K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
LANE-6KV SERIES
1 Watt Medical & Industrial DC/DC Power Converters
Rev E
FEATURES
• 1 Watt Output Power
• Small SIP Package
• 3000VACrms (6000VDC) I/O Isolation
• Reinforced Insulation Rated for 300VAC
Working Voltage
• Single & Dual Outputs
• Low Coupling Capacity
• Short Circuit Protection
• cUL/UL60950-1, CSA C22.2 No. 60950-1-03,
IEC/EN 60950-1 Industrial Safety Approvals
• -25°C to +85°C Operating Temperature
• MTBF > 2,000,000 Hours
• UL60601-1, CSA C22.2 No. 601-1, IEC/EN
60601-1 (3rd Edition) Medical Safety
Approvals
DESCRIPTION
Size:
Weight:
The LANE-6KV series of 1 watt DC/DC power converters are specially designed to provide
ultra-high levels of isolation in a miniature SIP package. This series consists of 12 models
with nominal input voltages of 5V and 12V and standard output voltages of 5V, 12V, and 15V
in both single and dual output configurations. The LANE-6KV has both industrial and medical
(3rd edition) approvals and offers an economical solution for many applications in industrial
controls and instrumentation, consumer electronics, and wherever a certified supplementary
or reinforced insulation system is required to comply with relative safety standards.
0.87 x 0.30 x 0.49 inches 0.14oz (3.9g)
22.0 x 7.5 x 12.5 mm
MODEL SELECTION TABLE
SINGLE OUTPUT MODELS
Output Current Input Current (Typ)
Max
Maximum
Capacitive
Load
Output
Voltage
Load
Output Efficiency
Model Number
Input Voltage
Min (1)
Max
No Load
Regulation Power
(Typ)
Load
LANE505N6KV
LANE512N6KV
LANE515N6KV
LANE1205N6KV
LANE1212N6KV
LANE1215N6KV
5 VDC
12 VDC
15 VDC
5 VDC
4mA
2mA
1mA
4mA
2mA
1mA
200mA
80mA
65mA
200mA
80mA
65mA
303mA
10%
8%
1W
1W
1W
1W
1W
1W
66%
66%
66%
66%
66%
66%
680μF
680μF
680μF
680μF
680μF
680μF
5 VDC
55mA
291mA
295mA
126mA
121mA
123mA
(4.5 - 5.5 VDC)
8%
10%
8%
12 VDC
12 VDC
15 VDC
30mA
(10.8 - 13.2
VDC)
8%
DUAL OUTPUT MODELS
Output Current Input Current (Typ)
Max
Maximum
Capacitive
Load
Output
Voltage
Load
Output Efficiency
Model Number
Input Voltage
Min (1)
Max
No Load
Regulation Power
(Typ)
Load
LANE505ND6KV
LANE512ND6KV
LANE515ND6KV
LANE1205ND6KV
LANE1212ND6KV
LANE1215ND6KV
±5 VDC
±2mA ±100mA
303mA
10%
8%
1W
1W
1W
1W
1W
1W
66%
72%
73%
66%
74%
75%
±220μF
±220μF
±220μF
±220μF
±220μF
±220μF
5 VDC
±12 VDC ±1mA ±40mA
±15 VDC ±1mA ±35mA
55mA
267mA
287mA
126mA
108mA
117mA
(4.5 - 5.5 VDC)
8%
±5 VDC
±2mA ±100mA
10%
8%
12 VDC
±12 VDC ±1mA ±40mA
±15 VDC ±1mA ±35mA
30mA
(10.8 - 13.2
VDC)
8%
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-
05/22/2014
9797
Page 1 of 5
website: www.wallindustries.com • e-mail: sales@wallindustries.com
LANE-6KV SERIES
1 Watt Medical & Industrial DC/DC Power Converters
Rev E
TECHNICAL SPECIFICATIONS: LANE-6KV SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
INPUT SPECIFICATIONS
TEST CONDITIONS
Min Typ Max
Unit
VDC
5VDC nominal input models
4.5
10.8
-0.7
-0.7
5
12
5.5
13.2
9
Input Voltage Range
12VDC nominal input models
5VDC nominal input models
12VDC nominal input models
Input Surge Voltage (1sec, max.)
VDC
A
29
Reverse Polarity Input Current
Input Current
Internal Power Dissipation
Input Filter Type
0.3
See Table
650
No Load
mW
LC filter
OUTPUT SPECIFICATIONS
Output Voltage
See Table
Voltage Accuracy
Line Regulation
±1.0
±1.2
±3.0
±1.5
10
%
%
For Vin change of 1%
20% load to 100% load
5VDC and ±5VDC output models
Others
Load Regulation
%
8
Cross Regulation
Output Power
Dual output models; Balanced loads
±0.1
±1.0
1
%
W
Output Current
Minimum Load
Maximum Capacitive Load
Ripple & Noise
See Table
See Table
See Table
150
See Note 1
20MHz bandwidth
mVp-p
%/°C
Temperature Coefficient
PROTECTION
±0.01 ±0.02
Short Circuit Protection
GENERAL SPECIFICATIONS
Efficiency
Switching Frequency
Isolation Voltage (I/P to O/P)
Isolation Test Voltage (I/P to O/P) Flash tested for 1 second
Isolation Resistance (I/P to O/P) 500VDC
Isolation Capacitance (I/P to O/P) 100KHz, 1V
ENVIRONMENTAL SPECIFICATIONS
Operating Ambient Temperature See power derating curve
Case Temperature
Storage Temperature
Relative Humidity
Cooling
Lead Temperature
MTBF
0.5
s
Nominal input voltage and full load
60 seconds
See Table
50
3000
4500
10
80
100
KHz
VACrms
Vpk
GΩ
pF
15
20
-25
-50
+85
+90
+125
95
°C
°C
°C
Non-condensing
% RH
Natural convection is about 20LFM but is not equal to still air (0 LFM)
1.5mm from case for 10 sec.
MIL-HDBK-217F at 25°C, ground benign
Free air convection
260
2,000,000 hours
°C
PHYSICAL SPECIFICATIONS
Weight
0.14oz (3.9g)
Dimensions (L x W x H)
Case Material
Pin Material
0.87 x 0.30 x 0.49 inches (22.0 x 7.5 x 12.5 mm)
Non-conductive black plastic
Alloy 42
Flammability to UL 94V-0 rated
SAFETY
Industrial
Safety Approvals
Medical
CUL/UL60950-1, CSA C22.2 No. 60950-1-03, IEC/EN 60950-1
UL 60601-1, CSA C22.2 No.601-1, IEC/EN 60601-1 (3rd edition)
NOTES
1. The LANE-6KV series requires a minimum load on the output to maintain specified regulation. Operation under no-load conditions will
not damage these devices; however they may not meet all listed specifications.
2. All DC/DC converters should be externally fused at the front end for protection.
3.Other input and output voltages may be available, please contact factory.
Due to advances in technology, specifications subject to change without notice.
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-
05/22/2014
9797
Page 2 of 5
website: www.wallindustries.com • e-mail: sales@wallindustries.com
LANE-6KV SERIES
1 Watt Medical & Industrial DC/DC Power Converters
Rev E
DERATING CURVE
MECHANICAL DRAWING
PIN CONNECTIONS
Pin
1
Single Output
+Vin
Dual Output
+Vin
2
-Vin
-Vin
5
-Vout
-Vout
6
No Pin
+Vout
Common
+Vout
7
NOTES:
1. Unit: inches (mm)
2. Tolerance: X.X±0.25 (X.XX±0.01)
X.XX±0.13 (X.XXX±0.005)
3. Pins: ±0.05 (±0.002)
4. Weight: 0.14oz (3.9g)
5. Pin Material: Alloy 42
6. Case Material:
plastic
non-conductive black
(flammability to UL94V-0 rated)
7. All dimensions are for reference only
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-
05/22/2014
9797
Page 3 of 5
website: www.wallindustries.com • e-mail: sales@wallindustries.com
LANE-6KV SERIES
1 Watt Medical & Industrial DC/DC Power Converters
Rev E
DESIGN CONSIDERATIONS
Peak-to-Peak Output Noise Measurement Test
Use a 0.33µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-
20MHz. Position the load between 50mm and 75mm from the DC/DC converter.
TEST SETUP
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect
the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be
necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure
stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz)
capacitor of 2.2µF for the 5V input devices and a 1.0µF for the 12V input devices.
Output Ripple Reduction
A good quality low ESR capacitor placed as close as possible across the load will give the best ripple and noise performance.
To reduce output ripple, it is recommended to use 1.5µF capacitors at the output.
Maximum Capacitive Load
The LANE-6KV series has a limitation of maximum connected capacitance on the output. The power module may be
operated in current limiting mode during start-up, affecting the ramp-up and the start-up time. For optimum performance we
recommend 220µF maximum capacitive load for dual outputs and 680µF capacitive load for single outputs. The maximum
capacitance can be found in the Model Selection Table.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module, and board
spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case
temperature must be kept below 90°C. The derating curves are determined from measurements obtained in a test setup.
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-
05/22/2014
9797
Page 4 of 5
website: www.wallindustries.com • e-mail: sales@wallindustries.com
LANE-6KV SERIES
1 Watt Medical & Industrial DC/DC Power Converters
Rev E
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and
development engineers will provide a solution that exceeds your performance requirements on-time and on
budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well-
documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for
working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements.
We will continue to provide ongoing support for your project above and beyond the design and production phases.
Give us a call today to discuss your future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
(603)778-2300
(888)597-9255
(603)778-9797
E-mail:
Web:
Address:
sales@wallindustries.com
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-
05/22/2014
9797
Page 5 of 5
website: www.wallindustries.com • e-mail: sales@wallindustries.com
相关型号:
©2020 ICPDF网 联系我们和版权申明