LANE6KV_16 [WALL]

1 Watt Medical & Industrial DC/DC Power Converters;
LANE6KV_16
型号: LANE6KV_16
厂家: WALL INDUSTRIES,INC.    WALL INDUSTRIES,INC.
描述:

1 Watt Medical & Industrial DC/DC Power Converters

文件: 总5页 (文件大小:513K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
LANE-6KV SERIES  
1 Watt Medical & Industrial DC/DC Power Converters  
Rev E  
FEATURES  
1 Watt Output Power  
Small SIP Package  
3000VACrms (6000VDC) I/O Isolation  
Reinforced Insulation Rated for 300VAC  
Working Voltage  
Single & Dual Outputs  
Low Coupling Capacity  
Short Circuit Protection  
cUL/UL60950-1, CSA C22.2 No. 60950-1-03,  
IEC/EN 60950-1 Industrial Safety Approvals  
-25°C to +85°C Operating Temperature  
MTBF > 2,000,000 Hours  
UL60601-1, CSA C22.2 No. 601-1, IEC/EN  
60601-1 (3rd Edition) Medical Safety  
Approvals  
DESCRIPTION  
Size:  
Weight:  
The LANE-6KV series of 1 watt DC/DC power converters are specially designed to provide  
ultra-high levels of isolation in a miniature SIP package. This series consists of 12 models  
with nominal input voltages of 5V and 12V and standard output voltages of 5V, 12V, and 15V  
in both single and dual output configurations. The LANE-6KV has both industrial and medical  
(3rd edition) approvals and offers an economical solution for many applications in industrial  
controls and instrumentation, consumer electronics, and wherever a certified supplementary  
or reinforced insulation system is required to comply with relative safety standards.  
0.87 x 0.30 x 0.49 inches 0.14oz (3.9g)  
22.0 x 7.5 x 12.5 mm  
MODEL SELECTION TABLE  
SINGLE OUTPUT MODELS  
Output Current Input Current (Typ)  
Max  
Maximum  
Capacitive  
Load  
Output  
Voltage  
Load  
Output Efficiency  
Model Number  
Input Voltage  
Min (1)  
Max  
No Load  
Regulation Power  
(Typ)  
Load  
LANE505N6KV  
LANE512N6KV  
LANE515N6KV  
LANE1205N6KV  
LANE1212N6KV  
LANE1215N6KV  
5 VDC  
12 VDC  
15 VDC  
5 VDC  
4mA  
2mA  
1mA  
4mA  
2mA  
1mA  
200mA  
80mA  
65mA  
200mA  
80mA  
65mA  
303mA  
10%  
8%  
1W  
1W  
1W  
1W  
1W  
1W  
66%  
66%  
66%  
66%  
66%  
66%  
680μF  
680μF  
680μF  
680μF  
680μF  
680μF  
5 VDC  
55mA  
291mA  
295mA  
126mA  
121mA  
123mA  
(4.5 - 5.5 VDC)  
8%  
10%  
8%  
12 VDC  
12 VDC  
15 VDC  
30mA  
(10.8 - 13.2  
VDC)  
8%  
DUAL OUTPUT MODELS  
Output Current Input Current (Typ)  
Max  
Maximum  
Capacitive  
Load  
Output  
Voltage  
Load  
Output Efficiency  
Model Number  
Input Voltage  
Min (1)  
Max  
No Load  
Regulation Power  
(Typ)  
Load  
LANE505ND6KV  
LANE512ND6KV  
LANE515ND6KV  
LANE1205ND6KV  
LANE1212ND6KV  
LANE1215ND6KV  
±5 VDC  
±2mA ±100mA  
303mA  
10%  
8%  
1W  
1W  
1W  
1W  
1W  
1W  
66%  
72%  
73%  
66%  
74%  
75%  
±220μF  
±220μF  
±220μF  
±220μF  
±220μF  
±220μF  
5 VDC  
±12 VDC ±1mA ±40mA  
±15 VDC ±1mA ±35mA  
55mA  
267mA  
287mA  
126mA  
108mA  
117mA  
(4.5 - 5.5 VDC)  
8%  
±5 VDC  
±2mA ±100mA  
10%  
8%  
12 VDC  
±12 VDC ±1mA ±40mA  
±15 VDC ±1mA ±35mA  
30mA  
(10.8 - 13.2  
VDC)  
8%  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-  
05/22/2014  
9797  
Page 1 of 5  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
LANE-6KV SERIES  
1 Watt Medical & Industrial DC/DC Power Converters  
Rev E  
TECHNICAL SPECIFICATIONS: LANE-6KV SERIES  
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.  
We reserve the right to change specifications based on technological advances.  
SPECIFICATION  
INPUT SPECIFICATIONS  
TEST CONDITIONS  
Min Typ Max  
Unit  
VDC  
5VDC nominal input models  
4.5  
10.8  
-0.7  
-0.7  
5
12  
5.5  
13.2  
9
Input Voltage Range  
12VDC nominal input models  
5VDC nominal input models  
12VDC nominal input models  
Input Surge Voltage (1sec, max.)  
VDC  
A
29  
Reverse Polarity Input Current  
Input Current  
Internal Power Dissipation  
Input Filter Type  
0.3  
See Table  
650  
No Load  
mW  
LC filter  
OUTPUT SPECIFICATIONS  
Output Voltage  
See Table  
Voltage Accuracy  
Line Regulation  
±1.0  
±1.2  
±3.0  
±1.5  
10  
%
%
For Vin change of 1%  
20% load to 100% load  
5VDC and ±5VDC output models  
Others  
Load Regulation  
%
8
Cross Regulation  
Output Power  
Dual output models; Balanced loads  
±0.1  
±1.0  
1
%
W
Output Current  
Minimum Load  
Maximum Capacitive Load  
Ripple & Noise  
See Table  
See Table  
See Table  
150  
See Note 1  
20MHz bandwidth  
mVp-p  
%/°C  
Temperature Coefficient  
PROTECTION  
±0.01 ±0.02  
Short Circuit Protection  
GENERAL SPECIFICATIONS  
Efficiency  
Switching Frequency  
Isolation Voltage (I/P to O/P)  
Isolation Test Voltage (I/P to O/P) Flash tested for 1 second  
Isolation Resistance (I/P to O/P) 500VDC  
Isolation Capacitance (I/P to O/P) 100KHz, 1V  
ENVIRONMENTAL SPECIFICATIONS  
Operating Ambient Temperature See power derating curve  
Case Temperature  
Storage Temperature  
Relative Humidity  
Cooling  
Lead Temperature  
MTBF  
0.5  
s
Nominal input voltage and full load  
60 seconds  
See Table  
50  
3000  
4500  
10  
80  
100  
KHz  
VACrms  
Vpk  
GΩ  
pF  
15  
20  
-25  
-50  
+85  
+90  
+125  
95  
°C  
°C  
°C  
Non-condensing  
% RH  
Natural convection is about 20LFM but is not equal to still air (0 LFM)  
1.5mm from case for 10 sec.  
MIL-HDBK-217F at 25°C, ground benign  
Free air convection  
260  
2,000,000 hours  
°C  
PHYSICAL SPECIFICATIONS  
Weight  
0.14oz (3.9g)  
Dimensions (L x W x H)  
Case Material  
Pin Material  
0.87 x 0.30 x 0.49 inches (22.0 x 7.5 x 12.5 mm)  
Non-conductive black plastic  
Alloy 42  
Flammability to UL 94V-0 rated  
SAFETY  
Industrial  
Safety Approvals  
Medical  
CUL/UL60950-1, CSA C22.2 No. 60950-1-03, IEC/EN 60950-1  
UL 60601-1, CSA C22.2 No.601-1, IEC/EN 60601-1 (3rd edition)  
NOTES  
1. The LANE-6KV series requires a minimum load on the output to maintain specified regulation. Operation under no-load conditions will  
not damage these devices; however they may not meet all listed specifications.  
2. All DC/DC converters should be externally fused at the front end for protection.  
3.Other input and output voltages may be available, please contact factory.  
Due to advances in technology, specifications subject to change without notice.  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-  
05/22/2014  
9797  
Page 2 of 5  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
LANE-6KV SERIES  
1 Watt Medical & Industrial DC/DC Power Converters  
Rev E  
DERATING CURVE  
MECHANICAL DRAWING  
PIN CONNECTIONS  
Pin  
1
Single Output  
+Vin  
Dual Output  
+Vin  
2
-Vin  
-Vin  
5
-Vout  
-Vout  
6
No Pin  
+Vout  
Common  
+Vout  
7
NOTES:  
1. Unit: inches (mm)  
2. Tolerance: X.X±0.25 (X.XX±0.01)  
X.XX±0.13 (X.XXX±0.005)  
3. Pins: ±0.05 (±0.002)  
4. Weight: 0.14oz (3.9g)  
5. Pin Material: Alloy 42  
6. Case Material:  
plastic  
non-conductive black  
(flammability to UL94V-0 rated)  
7. All dimensions are for reference only  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-  
05/22/2014  
9797  
Page 3 of 5  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
LANE-6KV SERIES  
1 Watt Medical & Industrial DC/DC Power Converters  
Rev E  
DESIGN CONSIDERATIONS  
Peak-to-Peak Output Noise Measurement Test  
Use a 0.33µF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-  
20MHz. Position the load between 50mm and 75mm from the DC/DC converter.  
TEST SETUP  
Input Source Impedance  
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect  
the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be  
necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure  
stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz)  
capacitor of 2.2µF for the 5V input devices and a 1.0µF for the 12V input devices.  
Output Ripple Reduction  
A good quality low ESR capacitor placed as close as possible across the load will give the best ripple and noise performance.  
To reduce output ripple, it is recommended to use 1.5µF capacitors at the output.  
Maximum Capacitive Load  
The LANE-6KV series has a limitation of maximum connected capacitance on the output. The power module may be  
operated in current limiting mode during start-up, affecting the ramp-up and the start-up time. For optimum performance we  
recommend 220µF maximum capacitive load for dual outputs and 680µF capacitive load for single outputs. The maximum  
capacitance can be found in the Model Selection Table.  
Thermal Considerations  
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module, and board  
spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case  
temperature must be kept below 90°C. The derating curves are determined from measurements obtained in a test setup.  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-  
05/22/2014  
9797  
Page 4 of 5  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
LANE-6KV SERIES  
1 Watt Medical & Industrial DC/DC Power Converters  
Rev E  
COMPANY INFORMATION  
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and  
development engineers will provide a solution that exceeds your performance requirements on-time and on  
budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well-  
documented product for our customers.  
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for  
working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements.  
We will continue to provide ongoing support for your project above and beyond the design and production phases.  
Give us a call today to discuss your future projects.  
Contact Wall Industries for further information:  
Phone:  
Toll Free:  
Fax:  
(603)778-2300  
(888)597-9255  
(603)778-9797  
E-mail:  
Web:  
Address:  
sales@wallindustries.com  
www.wallindustries.com  
37 Industrial Drive  
Exeter, NH 03833  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-  
05/22/2014  
9797  
Page 5 of 5  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  

相关型号:

LANE905N

1 Watts DC/DC Power Converters Single and Dual Outputs
WALL

LANE905N2

2 Watts DC/DC Converter Single and Dual Output
WALL

LANE905ND

1 Watts DC/DC Power Converters Single and Dual Outputs
WALL

LANE905ND2

2 Watts DC/DC Converter Single and Dual Output
WALL

LANE905NDH

1 Watt Output Power
WALL

LANE905NH

1 Watt Output Power
WALL

LANE909N

1 Watts DC/DC Power Converters Single and Dual Outputs
WALL

LANE909N2

2 Watts DC/DC Converter Single and Dual Output
WALL

LANE909ND

1 Watts DC/DC Power Converters Single and Dual Outputs
WALL

LANE909ND2

2 Watts DC/DC Converter Single and Dual Output
WALL

LANE909NDH

1 Watt Output Power
WALL

LANE909NH

1 Watt Output Power
WALL