RBA30-24S15CH [WALL]

Ultra Wide 4:1 Input Voltage Range;
RBA30-24S15CH
型号: RBA30-24S15CH
厂家: WALL INDUSTRIES,INC.    WALL INDUSTRIES,INC.
描述:

Ultra Wide 4:1 Input Voltage Range

文件: 总10页 (文件大小:1518K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
RBA30 SERIES  
30 Watts  
DC/DC Converter  
Single & Dual Output  
Rev A  
Through Hole Package  
Chassis Mount  
DIN Rail Mount  
Size: 2 x 1 x 0.47in (50.80 x 25.4 x 11.80mm)  
Through Hole with Heatsink Package  
Size: 2.99 x 1.24 x 0.84in (76 x 31.5 x 21.2mm)  
Chassis Mount with Heatsink  
Size: 2.99 x 1.24 x 1.02in (76 x 31.5 x 25.8mm)  
DIN Rail Mount with Heatsink  
Size: 2 x 1 x 0.64in (50.80 x 25.4 x 16.3mm)  
Size: 2.99 x 1.24 x 0.99in (76 x 31.5 x 25.1mm)  
Size: 2.99 x 1.24 x 1.17in (76 x 31.5 x 29.7mm)  
OPTIONS  
FEATURES  
Ultra Wide 4:1 Input Voltage Range  
Isolated & Regulated Single & Dual Output  
High Efficiency  
Through Hole, Chassis Mount, or DIN Rail  
Package  
Package Type  
-Through Hole  
-Chassis Mount  
-DIN Rail  
RoHS Compliant  
Input Under Voltage Protection  
Over Voltage, Over Current, and Short Circuit Protection  
Reverse Voltage Protection Available for Chassis Mount  
and DIN Rail Models  
Heatsink  
Optional Heatsink Available  
Isolation Voltage of 1500VDC  
Six-Sided Shielded Metal Packaging  
Meets CISPR22/EN55022 Class A Without External  
Components  
IEC60950, UL60950, and EN60950 Safety Approvals  
APPLICATIONS  
DESCRIPTION  
Industrial Robotics  
The RBA30 series of DC/DC converters offers up to 30 watts of output power in either a through hole package,  
chassis mounted package, or DIN rail mounted package. This series consists of single and dual output models  
with an ultra-wide 4:1 input voltage range. Features of this series include high efficiency, six-sided shielding,  
optional heatsink, and input under voltage protection as well as over voltage, over current, and short circuit  
protection. This series meets CISPR22/EN55022 Class A without external components, is RoHS compliant, and  
has IEC60950, UL60905, and EN60950 safety approvals. Please contact factory for ordering information.  
MODEL SELECTION TABLE  
Single Output Models  
Output Current  
Min Load Max Load Min. Typ.  
Efficiency(3)  
Maximum  
Ripple &  
Noise  
Output  
Power  
Model Number(1) Input Voltage Range(2) Output Voltage  
Certification  
UL/CE/CB  
Capacitive Load(4)  
RBA30-24S03  
RBA30-24S05  
RBA30-24S09  
RBA30-24S12  
RBA30-24S15  
RBA30-24S24  
RBA30-48S03  
RBA30-48S05  
RBA30-48S12  
RBA30-48S15  
RBA30-48S24  
3.3VDC  
5VDC  
9VDC  
0mA  
0mA  
0mA  
0mA  
0mA  
0mA  
0mA  
0mA  
0mA  
0mA  
0mA  
6000mA 83% 85%  
6000mA 86% 88%  
3333mA 86% 88%  
2500mA 88% 90%  
2000mA 88% 90%  
1250mA 88% 90%  
6000mA 84% 86%  
6000mA 86% 88%  
2500mA 86% 88%  
2500mA 87% 89%  
1250mA 87% 89%  
10000µF  
10000µF  
4700µF  
2700µF  
1680µF  
680µF  
10000µF  
10000µF  
2700µF  
1680µF  
680µF  
24VDC  
(9~36VDC)  
50mVp-p  
50mVp-p  
30W  
30W  
12VDC  
15VDC  
24VDC  
3.3VDC  
5VDC  
12VDC  
15VDC  
24VDC  
48VDC  
(18~75VDC)  
UL/CE/CB  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •  
Fax 603-778-9797  
11/21/2017  
Page 1 of 10  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
RBA30 SERIES  
30 Watts  
DC/DC Converter  
Single & Dual Output  
Rev A  
MODEL SELECTION TABLE  
Dual Output Models  
Output Current  
Min Load Max Load Min. Typ.  
Efficiency(3)  
Maximum  
Capacitive Load(4)  
2000µF  
Ripple &  
Noise  
Output  
Model Number(1) Input Voltage Range(2) Output Voltage  
Certification  
Power  
RBA30-24D05  
RBA30-24D12  
RBA30-24D15  
RBA30-24D24  
RBA30-48D05  
RBA30-48D12  
RBA30-48D15  
±5VDC  
±12VDC  
±15VDC  
±24VDC  
±5VDC  
0mA  
0mA  
0mA  
0mA  
0mA  
0mA  
0mA  
±3000mA 84% 86%  
±1250mA 87% 89%  
±1000mA 87% 89%  
±625mA 87% 89%  
±3000mA 84% 86%  
±1250mA 86% 88%  
±1000mA 86% 88%  
24VDC  
(9~36VDC)  
1250µF  
680µF  
470µF  
2000µF  
1250µF  
680µF  
50mVp-p  
50mVp-p  
30W  
30W  
CE  
CE  
48VDC  
(18~75VDC)  
±12VDC  
±15VDC  
SPECIFICATIONS  
All specifications are based on 25°C, humidity <75%RH, Nominal Input Voltage, and Rated Output Load unless otherwise noted.  
We reserve the right to change specifications based on technological advances.  
SPECIFICATION  
TEST CONDITIONS  
Min  
Typ  
Max  
Unit  
INPUT SPECIFICATIONS  
24VDC Nominal Input  
48VDC Nominal Input  
24VDC Nominal Input  
48VDC Nomianl Input  
9
18  
24  
48  
36  
75  
40  
Input Voltage Range  
VDC  
VDC  
Absolute Maximum Input(5)  
80  
3.3VDC Output Models  
5VDC Output Models  
Other Models  
3.3VDC Output Models  
5VDC Output Models  
Other Models  
3.3VDC Output Models  
5VDC Output Models  
Other Models  
970  
1420  
1388  
474  
710  
702  
60  
993  
1453  
1488  
485  
726  
744  
100  
100  
12  
24VDC Nominal Input  
48VDC Nominal Input  
24VDC Nominal Input  
48VDC Nominal Input  
Full Load Input Current  
No Load Input Current  
mA  
mA  
60  
6
3.3VDC Output Models  
5VDC  
20  
20  
30  
35  
Other Models  
5
10  
Reflected Ripple Current  
Nominal Input Voltage  
24VDC Nominal Input  
48VDC Nominal Input  
24VDC Nominal Input  
48VDC Nominal Input  
24VDC Nominal Input  
48VDC Nominal Input  
40  
mA  
-0.7  
-0.7  
50  
100  
9
Input Surge Voltage (1sec. max.)  
VDC  
Starting Voltage  
VDC  
VDC  
18  
5.5  
12.0  
6.5  
15.5  
Shutdown Voltage  
Input Filter  
Pi Filter  
Module Switch On, Ctrl suspended or connected to TTL high level  
Module Switch Off, Ctrl pin connected to GND or low level  
Input Current when Switched Off  
3.5  
0
12  
1.2  
8
VDC  
VDC  
mA  
Ctrl(6)  
5
OUTPUT SPECIFICATIONS  
Output Voltage  
See Table  
±1  
±1  
5%-100% Load  
0%-5% Load  
Full Load, input voltage from Positive Output  
low voltage to high voltage  
±3  
±5  
Voltage Accuracy  
Line Regulation  
Load Regulation(7)  
Cross Regulation  
%
%
%
±0.2  
±0.5  
±0.5  
±0.5  
±0.5.  
±1  
Negative Output  
Positive Output  
Negative Output  
±1  
5%-100% Load  
±1.5  
Dual Output, Main Output 50% load  
Supplement output from 10% to 100% load  
±5  
%
Trim  
±10  
%Vo  
Output Power  
Output Current  
Maximum Capacitive Load  
See Table  
See Table  
See Table  
Single Outputs  
Dual Outputs  
25% load step change, nominal input voltage  
50  
100  
150  
500  
±8  
Nominal Input Voltage, 100%  
Load  
Ripple & Noise (20MHz bandwidth)(8)  
mVp-p  
µs  
50  
300  
±5  
Transient Recovery Time  
3.3VDC, 5VDC, & ±5VDC Outputs  
Others  
25% load step change,  
nominal input voltage  
Transient Response Deviation  
%
±3  
±5  
Starting Time  
Temperature Coefficient  
Nominal Input Voltage & Constant Resistance Load  
Full Load  
10  
ms  
%/ºC  
±0.03  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •  
Fax 603-778-9797  
11/21/2017  
Page 2 of 10  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
RBA30 SERIES  
30 Watts  
DC/DC Converter  
Single & Dual Output  
Rev A  
SPECIFICATIONS  
All specifications are based on 25°C, humidity <75%RH, Nominal Input Voltage, and Rated Output Load unless otherwise noted.  
We reserve the right to change specifications based on technological advances.  
SPECIFICATION  
TEST CONDITIONS  
Min  
Typ  
Max  
Unit  
PROTECTION  
Short Circuit Protection  
Over Current Protection  
Over Voltage Protection  
ENVIRONMENTAL SPECIFICATIONS  
Operating Temperature  
Storage Temperature  
Storage Humidity  
Input Voltage Range  
Input Voltage Range  
Input Voltage Range  
Hiccup, Continuous, Self-Recovery  
110  
110  
190  
160  
%Io  
%Vo  
-40  
-55  
5
+80  
+125  
95  
ºC  
ºC  
%RH  
ºC  
Non-Condensing  
Pin Welding Resistance Temperature Welding spot is 1.5mm away from the casing, 10 seconds  
Vibration  
+300  
10-55Hz, 10G, 30 Min. along X, Y, and Z  
MTBF (MIL-HDBK-217F)  
GENERAL SPECIFICATIONS  
Efficiency  
25ºC, Full Load (Ground, Benign, Controlled Environment  
1000  
kHours  
@Full Load  
PWM mode  
See Table  
300  
Switching Frequency(9)  
Insulation Voltage  
KHz  
VDC  
Input-Output, with test time of 1 minute & leak current <1mA  
Input-Output, Insulation voltage 500VDC/60sec., Ta=25ºC,  
humidity=75%RH  
1500  
1000  
Insulation Resistance  
MΩ  
Isolation Capacitance  
PHYSICAL SPECIFICATIONS  
Input-Output, 100KHz/0.1V  
2000  
0.92oz (26g)  
pF  
Through Hole Package  
Without Heatsink  
With Heatsink  
Chassis Mount  
1.69oz (48g)  
2.40oz (68g)  
1.20oz (34g)  
1.98oz (56g)  
2.68oz (76g)  
2in x 1in x 0.47in  
DIN Rail Mount  
Through Hole Package  
Chassis Mount  
Weight  
DIN Rail Mount  
Through Hole Package  
Chassis Mount  
(50.80mm x 25.4mm x 11.80mm)  
2.99in x 1.24in x 0.84in  
(76mm x 31.5mm x 21.2mm)  
2.99in x 1.24in x 1.02in  
(76mm x 31.5mm x 25.8mm)  
2in x 1in x 0.64in  
(50.80mm x 25.4mm x 16.3mm)  
2.99in x 1.24in x 0.99in  
(76mm x 31.5mm x 25.1mm)  
2.99in x 1.24in x 1.17in  
(76mm x 31.5mm x 29.7mm)  
Free Air Convection  
Without Heatsink  
With Heatsink  
DIN Rail Mount  
Dimensions (L x W x H)  
Through Hole Package  
Chassis Mount  
DIN Rail Mount  
Cooling Method  
Shielding  
Six-Sided  
SAFETY CHARACTERISTICS  
Safety Approvals  
IEC60950, UL60950, & EN60950  
CISPR22/EN55022  
Single Output  
Dual Output  
Single Output  
Dual Output  
Class A (Bare Component)/Class B(10)  
Class A (Bare Component)/Class B(10)  
Class A (Bare Component)/Class B(10)  
Class A (Bare Component)/Class B(10)  
Perf. Criteria B  
CE  
RE  
CISPR22/EN55022  
CISPR22/EN55022  
CISPR22/EN55022  
EMI  
ESD IEC/EN61000-4-2 Contact ±4kV  
RS IEC/EN61000-4-3 10V/m  
Perf. Criteria A  
Perf. Criteria B  
Perf. Criteria B  
Perf. Criteria B  
Perf. Criteria B  
Perf. Criteria A  
Perf. Criteria A  
Single Output  
Dual Output  
Single Output  
Dual Output  
Single Output  
Dual Output  
±2kV(10)  
EFT IEC/EN61000-4-4  
Surge IEC/EN61000-4-5  
±2kV(10)  
EMS  
Line to Line ±2kV(10)  
Line to Line ±2kV(10)  
3Vr.m.s  
CS  
IEC/EN61000-4-6  
10Vr.m.s  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •  
Fax 603-778-9797  
11/21/2017  
Page 3 of 10  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
RBA30 SERIES  
30 Watts  
DC/DC Converter  
Single & Dual Output  
Rev A  
NOTES  
1. Chassis Mount, DIN Rail Mount, and Heatsink are available options for this series. To indicate chassis mount, add “C” to model number. To  
indicate DIN Rail Mount, add “DN” to model number. To indicate Heatsink, add “H” to model number.  
2. Due to input reverse polarity protection function, chassis mount & DIN rail mount models minimum value input voltage range and starting voltage  
is higher than 1VDC DIP package.  
3. Efficiency is measured in nominal input voltage and rated output load. Due to input reverse polarity protection, minimum efficiency of chassis  
mount and DIN rail mount models greater than min. -2 is qualified.  
4. The capacitive loads of positive and negative outputs are identical. Maximum capacitive load offered were tested at input voltage range and full  
load.  
5. This is the absolute maximum rating the converter can operate at without damage, but it isn’t recommended.  
6. The voltage of Ctrl pin is relative to input pin GND.  
7. When testing from 0%-100% load working conditions, load regulation index of ±5%.  
8. Ripple & Noise are measured by “parallel cable” method. See application notes for specific operation.  
9. This series of products using reduced frequency technology, the switching frequency is test value of full load. When the load is reduced to below  
50%, the switching frequency decreases with decreasing load.  
10. See EMC solution-recommended circuit for recommended circuit.  
11. Customization is available.  
*Due to advances in technology, specifications subject to change without notice.  
DERATING CURVES  
Temperature Derating Curve (Single Output Models)  
Temperature Derating Curve (Single Output Models)  
Models: RBA30-24S09(H), RBA30-24S12(H), RBA30-24S15(H), RBA30-  
48S12(H), RBA30-48S12(H), RBA30-48S15(H), RBA30-48S24(H)  
Models: RBA30-24S03(H), RBA30-24S05(H), RBA48S03(H),  
RBA30-48S05(H)  
Temperature Derating Curve (Dual Output Models)  
Temperature Derating Curve (Dual Output Models)  
Models: RBA30-24D05(H) (18~36VDC Input Voltage), RBA30-24D24(H)  
(18~36VDC Input Voltage), RBA30-48D05 (36~75VDC Input Voltage),  
RBA30-24D12(H), RBA30-24D15(H), RBA30-48D12(H), RBA30-48D15(H)  
Models: RBA30-24D05(H) (9~18VDC Input), RBA30-24D24(H)  
(9~18VDC Input), RBA30-48D05(H) (18~36VDC Input)  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •  
Fax 603-778-9797  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
11/21/2017  
Page 4 of 10  
RBA30 SERIES  
30 Watts  
DC/DC Converter  
Single & Dual Output  
Rev A  
EFFICIENCY GRAPHS  
Efficiency vs. Input (Full Load)  
Efficiency vs. Output Load (24Vin)  
RBA30-24S05  
RBA30-24S05  
Efficiency vs. Input (Full Load)  
Efficiency vs. Output Load (48Vin)  
RBA30-48S15  
RBA30-48S15  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •  
Fax 603-778-9797  
11/21/2017  
Page 5 of 10  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
RBA30 SERIES  
30 Watts  
DC/DC Converter  
Single & Dual Output  
Rev A  
MECHANICAL DRAWINGS  
Through Hole Package  
Note: Grid 2.54*2.54mm  
Pin Out  
Single  
Pin  
1
2
3
4
Dual  
Vin  
Vin  
GND  
Ctrl  
Trim  
0V  
GND  
Ctrl  
-Vo  
5
0V  
6
+Vo  
+Vo  
Note:  
Unit: mm[inch]  
Pin diameter tolerances: ±0.10 [±0.004]  
General tolerances: ±0.50[±0.020]  
Through Hole Package with Heatsink (“H” Suffix)  
Pin Out  
Pin  
1
Single  
Vin  
Dual  
Vin  
2
3
4
5
GND  
Ctrl  
Trim  
0V  
GND  
Ctrl  
-Vo  
0V  
6
+Vo  
+Vo  
Note:  
Unit: mm[inch]  
General tolerances: ±0.50[±0.020]  
If heatsinks are being used, make sure there is  
enough space for a special size in above graph  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •  
Fax 603-778-9797  
11/21/2017  
Page 6 of 10  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
RBA30 SERIES  
30 Watts  
DC/DC Converter  
Single & Dual Output  
Rev A  
Chassis Mount (“C” Suffix)  
Pin Out  
Pin  
1
2
Single  
Ctrl  
GND  
Vin  
Dual  
Ctrl  
GND  
Vin  
3
4
5
Trim  
0V  
-Vo  
0V  
6
+Vo  
+Vo  
Note:  
Unit: mm[inch]  
Wire range: 24-12AWG  
Tightening torque: Max 0.4 Nm  
General tolerances: ±0.50[  
Chassis Mount with Heatsink (“CH” Suffix)  
Pin Out  
Pin  
1
2
Single  
Ctrl  
GND  
Vin  
Dual  
Ctrl  
GND  
Vin  
3
4
5
Trim  
0V  
-Vo  
0V  
6
+Vo  
+Vo  
Note:  
Unit: mm[inch]  
Wire range: 24-12AWG  
Tightening Torque: Max 0.4N∙m  
General tolerances: ±0.50 [±0.020]  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •  
Fax 603-778-9797  
11/21/2017  
Page 7 of 10  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
RBA30 SERIES  
30 Watts  
DC/DC Converter  
Single & Dual Output  
Rev A  
DIN Rail Mount (“DN” Suffix)  
Pin-Out  
Pin  
1
2
Single  
Ctrl  
GND  
Vin  
Dual  
Ctrl  
GND  
Vin  
3
4
5
Trim  
0V  
-V0  
0V  
6
+Vo  
+Vo  
Note:  
Unit: mm[inch  
Wire range: 24-12AWG  
Tightening torque: Max 0.4N∙m  
General tolerances: ±0.50[±0.020]  
DIN Rail Mount with Heatsink (“DNH” Suffix)  
Pin Out  
Pin  
1
2
Single  
Ctrl  
GND  
Vin  
Dual  
Ctrl  
GND  
Vin  
3
4
5
Trim  
0V  
-Vo  
0V  
6
+Vo  
+Vo  
Note:  
Unit: mm[inch]  
Wire range: 24-12 AWG  
Tightening torque: Max 0.4 N∙m  
General tolerances: ±0.50 [±0.020]  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •  
Fax 603-778-9797  
11/21/2017  
Page 8 of 10  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
RBA30 SERIES  
30 Watts  
DC/DC Converter  
Single & Dual Output  
Rev A  
DESIGN REFERENCE  
1. Typical Application  
All the DC/DC converters of this series are tested below according to the recommended circuit below. If it is required to further reduce input and output  
ripple, properly increase the input & output of additional capacitors Cin and Cout or select capacitors of low equivalent impedance provided that the  
capacitance is no larger than the max. capacitive load of the product.  
Single Output  
Voltage (VDC)  
3.3/5/9  
Cout  
(µF)  
220  
100  
Cin  
(µF)  
Dual Output  
Voltage (VDC)  
±5/±12/±15  
±24  
Cout  
(µF)  
220  
100  
Cin  
(µF)  
100  
100  
12/15/24  
2. EMC Solution-Recommended Circuit  
Parameter Description  
24Vin  
Choose according to actual input current  
Model  
FUSE  
MOV  
C0  
C1  
C2  
48Vin  
S20K30  
S14K60  
680µF/50V  
330µF/50V  
4.7µF/50V  
330µF/100V  
330µF/100V  
2.2µF/100V  
C3  
LCM  
CY1, CY2  
Refer to Cout in Typical Application Figure  
1mH, contact factory for recommendation  
1nF/2KV  
Note: Part in the figure above is used for EMS test and part for EMI  
filtering; selected based on needs.  
Parameter Description  
Model  
FUSE  
MOV  
C0  
C1  
C2  
24Vin  
Choose according to actual input current  
48Vin  
S20K30  
S14K60  
680µF/50V  
2.2µF/50V  
2.2µF/50V  
330µF/50V  
330µF/100V  
2.2µV/100V  
2.2µF/100V  
330µF/100V  
C3  
C4  
LDMI  
CY1, CY2  
Refer to Cout in Typical Application Figure  
3.3µH  
Notes: Part in the figure above is used for EMS test and part for EMI  
filtering; selected based on needs.  
2.2nF/400VAC Safety Y Capacitor  
3. Application of Trim and Calculation of Trim Resistance  
Calculation formula of Trim resistance:  
aR2  
R2-a  
Vref  
Vo’-Vref  
up: RT =  
-R3  
a=  
∙R1  
∙R2  
aR1  
R1-a  
Vo’-Vref  
Vref  
down: RT=  
-R3  
a=  
RT is Trim resistance, a is a self-defined parameter, with no real meaning.  
Vo’ for the actual needs of the up or down regulated votlage  
Vout (VDC)  
R1 (KΩ)  
4.801  
2.883  
R2 (KΩ)  
2.87  
2.87  
R3 (KΩ)  
12.4  
10  
Vref(V)  
1.24  
2.5  
3.3  
5
9
7.500  
2.87  
15  
2.5  
12  
15  
24  
11.000  
14.494  
24.872  
2.87  
2.87  
2.87  
15  
15  
17.8  
2.5  
2.5  
2.5  
Applied circuit of Trim (part in broken line is the interior of models)  
4. Models cannot be connected in parallel to increase power.  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •  
Fax 603-778-9797  
11/21/2017  
Page 9 of 10  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  
RBA30 SERIES  
30 Watts  
DC/DC Converter  
Single & Dual Output  
Rev A  
MODEL NUMBER SETUP  
RBA  
30  
-
12  
S
12  
C
H
Series Name  
Output Power  
Input Voltage  
Output Quantity  
Output Voltage  
Package  
Heatsink  
24: 24VDC  
48: 48VDC  
S: Single  
3.3: 3.3VDC  
5: 5VDC  
Blank: Through Hole  
C: Chassis Mount  
DN: DIN Rail Mount  
Blank: No Heatsink  
H: Heatsink  
9: 9VDC  
12: 12VDC  
15: 15VDC  
24: 24VDC  
D: Dual  
5: ±5VDC  
12: ±12VDC  
15: ±15VDC  
24: ±24VDC  
COMPANY INFORMATION  
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development  
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008  
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.  
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely  
with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide  
ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your  
future projects.  
Contact Wall Industries for further information:  
Phone:  
(603)778-2300  
Toll Free: (888)597-9255  
Fax:  
(603)778-9797  
E-mail:  
Web:  
sales@wallindustries.com  
www.wallindustries.com  
Address: 37 Industrial Drive  
Exeter, NH 03833  
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •  
Fax 603-778-9797  
11/21/2017  
Page 10 of 10  
website: www.wallindustries.com • e-mail: sales@wallindustries.com  

相关型号:

RBA30-24S15DNH

Ultra Wide 4:1 Input Voltage Range
WALL

RBA30-24S24

Ultra Wide 4:1 Input Voltage Range
WALL

RBA30-24S24CH

Ultra Wide 4:1 Input Voltage Range
WALL

RBA30-24S24DNH

Ultra Wide 4:1 Input Voltage Range
WALL

RBA30-24S3.3CH

Ultra Wide 4:1 Input Voltage Range
WALL

RBA30-24S3.3DNH

Ultra Wide 4:1 Input Voltage Range
WALL

RBA30-24S5CH

Ultra Wide 4:1 Input Voltage Range
WALL

RBA30-24S5DNH

Ultra Wide 4:1 Input Voltage Range
WALL

RBA30-24S9CH

Ultra Wide 4:1 Input Voltage Range
WALL

RBA30-24S9DNH

Ultra Wide 4:1 Input Voltage Range
WALL

RBA30-48D05

Ultra Wide 4:1 Input Voltage Range
WALL

RBA30-48D12

Ultra Wide 4:1 Input Voltage Range
WALL