RJW24S5-2000NRP [WALL]
Analog Circuit,;型号: | RJW24S5-2000NRP |
厂家: | WALL INDUSTRIES,INC. |
描述: | Analog Circuit, |
文件: | 总3页 (文件大小:132K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
RJW SERIES
TO 12 WATTS
Single/Dual Output DC/DC Converter
2” x 1” x 0.4” - up to 12 Watts Output
• Single/Dual Out DC/DC Converter, up to 12 Watts
• Ideal for Telecom and Networking Applications
• 4:1 Input Range, High Efficiency
• Industry Compatible Pin Out, 2” x 1” Form Factor
• Six Side Shielded, Low Profile 0.4” Height
• No external Input or Output Filtering required
• Regulated Output
• Over Voltage Protection
• Continuous Short Circuit Protection
• >1500VDC I/O Isolation
• Remote on/off control (with or without)
• Designed to meet UL, CSA, VDE, CE
OVERVIEW
The RJW Series of high efficiency DC/DC convert-
ers are available as single and dual output versions,
3.3VDC up to 15VDC, with up to 12 Watts of output
power. The product is ideal for Telecom and
TYPICAL APPLICATIONS:
• 9V-36V or 18-75VDC Telecom Input
• On-Board Distributed Power
• Low Profile & Height PCB
Networking applications. The converter is designed
for a 4:1 input range, either nominal 24 Volt (9VDC
-36VDC) or nominal 48VDC (18VDC-75VDC). The
converter is PCB mountable, the package has a
formfactor of 2”x1”x.04”. The standard specifica-
tions include the Pi-input filter, excellent load regula-
tion and short circuit protection. The isolation volt-
age meets the >1500VDC telecom requirements.
Model
Number
Input Output
Voltage Volts /mA
Effic.
%
VDC
VDC
SPECIFICATIONS:
Single Output
RJW24S33-2400
RJW24S5-2000
RJW24S12-1000
RJW24S15-800
RJW48S3.3-2400
RJW48S5-2000
RJW48S12-1000
RJW48S15-800
Nominal Input:
24VDC (9-36 VDC)
48VDC (18-75VDC)
Single / Dual, see Table 1
up to 12 W
9-36
9-36
9-36
9-36
3.3 //2400
5 // 2000
12 // 1000
15//800
78
82
84
84
78
82
84
84
Output Voltage:
Output Power:
Isolation Voltage:
>1500VDC (60 seconds)
Operating Temperature: -40C to +71C (ambient)
no derating
18-75 3.3 // 2400
18-75 5 // 2000
18-75 12 // 1000
18-75 15//800
Storage Temp.:
Max. Case Temp.:
Dimensions:
-40ºC to +125ºC
100C
2” x 1” x 0.4”
Dual Output
NOTES:
RJW24D5-1000
RJW24D12-500
RJW24D15-400
9-36
9-36
9-36
±5 // 1000
±12 // 500
±15 // 400
82
84
84
1) For negative logic remote on/off, add suffix “R” to
part number.
2) To remove remote option and pin, add suffix
“NRP”.
RJW48D5-1000
RJW48D12-500
RJW48D15-400
18-75 ±5 // 1000
18-75 ±12 // 500
18-75 ±15 // 400
82
84
84
for further information on these and other options,
please contact our factory directly.
5/10/04
1
(888) 597-9255
WWW.WALLINDUSTRIES.COM
RJW SERIES
TO 12 WATTS
SPECIFICATIONS
Min.
Specification
Method
Typ.
Max.
Units
INPUT VOLTAGE:
48V version
24V version
18
9
48
24
75
36
Volts
Volts
REMOTE ON/OFF
INPUT FILTER
TTL
TTL logic
LC-Filter
OUTPUT VOLTAGE
OUTPUT VOLTAGE
OUTPUT CURRENT
see table
+/- 1%
Volts
Set Point
% of Vout
A
see table
OVERCURRENT PROTECTION Limiting
% of Iout
mV peak/peak
OUTPUT RIPPLE
20MHz BW
<75mVpp
SHORT CIRCUIT PROTECTION continuous
LINE REGULATION
LOAD REGULATION
HL / LL
+/- 0.5%
+/- 0.5%
10-100% load
TRANSIENT RESPONSE
REMOTE ON/OFF
within +/-1% Vout
<500usec
Pin 6
TTL Logic
EFFICIENCY
see table
ISOLATION VOLTAGE
SWITCHING FREQUENCY
In/Out/ >100MOhms Res.
>1500VDC
400kHz typ.
VDC / 60sec
OPERATING TEMPERATURE
STORAGE TEMPERATURE
-40
+71
deg. C (amb)
degree C
-40
+125
WEIGHT
~ 1 oz
DIMENSIONS
CASE MATERIAL
case w/o pin
2”x 1”x 0.4”
Metal Case
inches
REMOTE ON/OFF (positive referenced)
Supply On
2.5 to 5.5VDC or open circuit
Supply Off
-0.7
-----
------
------
0.8
10
VDC
mA
Standby Input Current
Control Common
Referenced to Negative Input
REMOTE ON/OFF (negative referenced, suffix “R”)
Supply On
-0.7
3.5
-------
-------
1.2
VDC
Supply Off
10 VDC or open circuit
1mA max.
Source Current Remote Pin
Control Common
Referenced to Negative Input
5/10/04
WWW.WALLINDUSTRIES.COM
(888) 597-9255
2
TO 12 WATTS
RJW SERIES
Pin
1
Single
+ In
Dual
+ In
2
- In
- In
3
+ V Out
No Pin
- V Out
Remote
+ V Out
4
Common
5
- V Out
6
Remote (see note #2)
All case and Pin-to-Case dimensions are for reference only, unless otherwise noted. All
DC/DC converters should be externally fused at the front end for protection. Significant
capacitive load at the output of the converter may inhibit the start-up and operation.
5/10/04
(888) 597-9255
3
WWW.WALLINDUSTRIES.COM
相关型号:
©2020 ICPDF网 联系我们和版权申明