SP48S33-66 [WALL]

66W DC-DC Converter;
SP48S33-66
型号: SP48S33-66
厂家: WALL INDUSTRIES,INC.    WALL INDUSTRIES,INC.
描述:

66W DC-DC Converter

文件: 总7页 (文件大小:227K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
APPLICATION NOTES  
Rev C  
SP48S3.3-66  
66W DC-DC Converter  
36-75 Vdc Input  
3.3 Vdc Output at 20A  
Half-Brick Package  
Features:  
xꢀ Low Output Ripple  
xꢀ 80% Efficient at Full Load  
xꢀ Fast Transient Response  
xꢀ Operation to No Load  
xꢀ Fixed Switching Frequency  
xꢀ Output Over Current Protection  
xꢀ Output Short Circuit Protection  
xꢀ Over Temperature Protection  
xꢀ 1500 Vdc Isolation  
xꢀ 100% Burn In  
xꢀ Remote ON/OFF (Active High/Low)  
xꢀ Remote Sense Compensation  
xꢀ UL 1950 Listed - CE Mark  
xꢀ Test Board Available  
Description:  
The SP & SPW series is a high-density half brick converter that incorporates the desired features required in  
today’s demanding applications. When performance, reliability, and low cost are needed, the SP & SPW  
series delivers.  
(888) 597-WALL  
www.wallindustries.com  
1 of 7  
Rev C  
APPLICATION NOTES  
SP & SPW SERIES  
WALL INDUSTRIES, INC.  
Technical Specifications  
Model No. SP48S3.3-66  
All specifications are based on 25C, Nominal Line and Full Load unless otherwise noted.  
We reserve the right to change specifications based on technological advances.  
SPECIFICATION  
Related condition  
MIN  
NOM  
MAX  
Unit Measured  
INPUT  
Turn on at  
Turn off at  
34  
32  
Volt DC  
Volt DC  
Input Over voltage Shutdown  
Turn off at  
78  
77  
48  
2.283  
25  
2
Volt DC  
Volt DC  
Volt DC  
A
Turn on at  
Operating Voltage Range  
Maximum Input Current  
No Load Input Current  
Input Current under “LOGIC OFF”  
Inrush Current Transient Rating  
Reflected Ripple Current  
OUTPUT  
Rated Input Voltage  
Low Line 100% load  
36  
75  
mA  
mA  
A2 Sec  
mA  
20  
Output Voltage Set point  
Output Voltage Regulation  
Over Load  
3.267  
3.300  
3.333  
Volt DC  
0.1  
0.1  
0.02  
%
%
Over Line  
Over Temperature  
Output Voltage Ripple and Noise  
Basic Ripple  
% / oC  
mV  
mV  
A
A
A/sec  
Spikes P-P  
50  
20  
32  
Output Current Ranges  
Output Current Limit  
Short Term Output Current Surge  
DYNAMIC CHARACTERISTICS  
Input Voltage Ripple Rejection  
Output Transient and Load Changes  
Load step / delta V  
Load step / delta V  
Recovery Time  
Rated Output Current  
120 Hz  
0
24  
28  
dB  
X
X
50 to 75%  
75 to 50%  
50 to 100%  
100 to 50 %  
250  
250  
100  
250  
0
mV  
mV  
µsec  
M sec  
%
To within 1% Rated Vo  
From Vin(nom) to 90% Vout (nom)  
Full Load Resistive  
Turn on Delay  
Overshoot of Output Voltage  
EFFICIENCY  
@ 100% load  
@ 75% load  
@ 50% load  
@ 25% load  
80  
81  
82  
80  
%
%
%
%
TEMPERATURE CONSIDERATIONS  
Thermal Resistance  
Normal Convection  
100 lfm  
Rtheta c-a  
7.5  
6.2  
5.1  
4.3  
3.5  
oC/Watt  
oC/Watt  
oC/Watt  
oC/Watt  
oC/Watt  
200 lfm  
300 lfm  
400 lfm  
Heatsink Considerations  
General Technical Data  
Switching Frequency  
Remote ON OFF Control (See Note Below)  
Trimmablility  
Contact Factory  
FIXED  
Positive or Negative  
400  
105  
KHz  
Over Temperature Shutdown  
Case Temperature  
oC  
MTBF  
Bellcore TR-332 nom is 2.50m  
Hours  
Note: Positive Remote ON/OFF control is standard. To order negative logic Remote ON/OFF control add the suffix "R" to the part number.  
www.wallindustries.com  
2 of 7  
(888) 597-WALL  
Rev C  
APPLICATION NOTES  
WALL INDUSTRIES, INC.  
SP & SPW SERIES  
Figure 1: Mechanical Dimensions  
Unit: inches  
Tolerance: X.XX ±0.020  
X.XXX±0.010  
(888) 597-WALL  
www.wallindustries.com  
3 of 7  
Rev C  
APPLICATION NOTES  
WALL INDUSTRIES, INC.  
SP & SPW SERIES  
Output Voltage Trim  
The following information is provided to allow quick calculation of the trim resistor value for a desired output voltage. The general  
procedure for calculating a trim resistor is as follows:  
1. Determine the desired output voltage (Vo)  
2. Select Equation. (Trim Low/Trim High)  
3. Use the data in Table 1 to complete the equation.  
4. Evaluate.  
In order to trim low use Equation 1 and Table 1 to calculate resistor RTL for the desired output voltage.  
Equation 1: Trim Low  
ª
«
¬
º
»
¼
Vo VREF  
RT   
 R  
L
LIM  
VREF  
(
)  ( 1 ˜(Vo VREF ))  
RL  
RH  
Vo - Desired output voltage.  
All resistor values in K ohms.  
Schematic 1: Trim Low  
In order to trim high use Equation 2 and Table 1 to calculate resistor RTH for the desired output voltage.  
Equation 2: Trim High  
ª
«
º
»
VREF  
RTH   
 RLIM  
Vo VREF  
VREF  
RL  
«
»
   
RH  
¬
¼
Vo - Desired output voltage.  
All resistor values in K ohms.  
Schematic 2: Trim High  
MODEL  
RH  
RLIM  
RL  
VREF  
(Output Voltage)  
3.3V  
(K OHMS)  
(K OHMS)  
(K OHMS)  
(VOLTS)  
0.750  
0.499  
2.32  
2.495  
5.0V  
8.0V  
9.0V  
12.0V  
15.0V  
24.0V  
26.0V  
32.0V  
2.49  
5.49  
6.49  
9.53  
12.4  
21.5  
17.6  
23.7  
10.0  
10.0  
10.0  
13.7  
13.7  
15.4  
15.4  
12.7  
2.49  
2.49  
2.49  
2.49  
2.49  
2.49  
1.87  
2.00  
2.495  
2.495  
2.495  
2.495  
2.495  
2.495  
2.495  
2.495  
Table 1 : Trim Low/High Data Table.  
Note: Output trim +/- 10% max.  
(888) 597-WALL  
www.wallindustries.com  
4 of 7  
Rev C  
APPLICATION NOTES  
SP & SPW SERIES  
WALL INDUSTRIES, INC.  
DERATING CURVE  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
0 LFM  
100 LFM  
200 LFM  
300 LFM  
400 LFM  
5
15  
25  
35  
45  
55  
65  
75  
85  
95  
105  
A MBIENT TEMPERA TURE 0C  
SP 48S3.3-66  
POWER DISSIPATION VS OUTPUT POWER  
20  
18  
16  
14  
12  
10  
8
36 VIN  
48 VIN  
75VIN  
6
4
2
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
% OUTPUT POWER  
SP48S3.3-66  
EFFICIENCY VS RATED OUTPUT POWER  
90  
80  
70  
60  
50  
40  
30  
36V  
48V  
75V  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
RATED OUTPUT POWER (%)  
SP48S3.3-66  
(888) 597-WALL  
www.wallindustries.com  
5 of 7  
Rev C  
APPLICATION NOTES  
SP & SPW SERIES  
WALL INDUSTRIES, INC.  
TYPICAL OUTPUT RIPPLE VOLTAGE  
20mV/div, 2 us/div, full load 48 vin 10 uF  
decoupling cap. Room temperature.  
TYPICAL INPUT REFLECTED RIPPLE CURRENT  
20mA/div, full load 48 vin.(using 12uH, 33uF (low ESR)  
source impedance). Room temperature.  
TYPICAL RISE TIME AND TURN ON DELAY  
USING LOGIC ENABLE  
TYPICAL RISE TIME AND TURN ON DELAY  
WITH VIN 0-48V  
1 V/div, 10 mS/div, (vout) 2 V/div, 10 mS/div  
(logic enable) 48 vin, full load. Room temperature.  
1V/div, 10 mS/div, (vout) 20 V/div 10 mS/div (vin)  
48 vin full load. Room temperature.  
SP48S3.3-66  
(888) 597-WALL  
6 of 7  
www.wallindustries.com  
Rev C  
APPLICATION NOTES  
WALL INDUSTRIES, INC.  
SP48S3.3-66  
Ordering Information:  
Part Number Example:  
SP 48 S 3.3- 66 R  
Series  
Designation  
Nominal  
Input  
Voltage  
Single  
Output  
Nominal  
Output  
Voltage  
Maximum  
Output  
Power  
Options  
Blank  
Leave Blank for  
Active High Enable  
R
Active Low Enable  
Company Information:  
Wall Industries, Inc. has created custom and modified units for over 40 years. Our in-house research and development engineers will  
provide a solution that exceeds your performance requirements on time and on budget. Our ISO9001-2000 certification is just one  
example of our commitment to producing a high quality, well documented product for our customers.  
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its  
customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for  
your project above and beyond the design and production phases. Give us a call today to discuss your future projects.  
Contact Wall Industries for further information:  
Phone:  
Toll Free:  
Fax:  
(603)778-2300  
(888)587-9255  
(603)778-9797  
E-mail:  
Web:  
sales@wallindustries.com  
www.wallindustries.com  
5 Watson Brook Rd.  
Exeter, NH 03833  
Address:  
(888) 597-WALL  
www.wallindustries.com  
7 of 7  

相关型号:

SP48S48-100

Isolated and Regulated
WALL

SP48S48-50

Isolated and Regulated
WALL

SP48S48-75

Isolated and Regulated
WALL

SP48S5-100

Isolated and Regulated
WALL

SP48S5-50

Isolated and Regulated
WALL

SP48S5-75

Isolated and Regulated
WALL

SP48S6-100

Isolated and Regulated
WALL

SP48S6-50

Isolated and Regulated
WALL

SP48S6-75

Isolated and Regulated
WALL

SP490

Full Duplex RS-485 Transceivers
SIPEX

SP490

Full Duplex RS-485 Transceivers
EXAR

SP4902DP

Prescaler, Bipolar, PDIP8
DYNEX