WMIHPU15 SERIES
Up to 15 Watts, Medical AC/DC Wall Mount Power Supplies
Rev A
Wall Industries, Inc.
FEATURES
Class II System
RoHS Compliant
Single Outputs Ranging from 3VDC to 55VDC
-10°C to +70°C Operating Temperature Range
Up to 15 Watts Output Power
86% High Efficiency
Meets FCC Part-18 Class B & CISPR-11 EN55011
Class B Emission Limits
Energy Star 2.0, Efficiency Level V
80-275VAC Input Voltage Range
Over Voltage & Over Load Protection
Input to Output: 2MOPP
UL/cUL 3rd Edition Medical Approvals
Interchangeable Plug Options: United States,
Europe, Australia, & United Kingdom Types
Optional Output Connectors Available
SAFETY APPROVALS
Size:
Weight:
5.82oz (165g)
2.36 x 1.71 x 1.58 inches
60.0 x 43.5 x 40.2 mm
DESCRIPTION
The WMIHPU15 series of Class II medical AC/DC wall mount power supplies offers up to 15
watts of output power in a 2.36” x 1.71” x 1.58” package. This series consists of single output
models ranging from 3VDC to 55VDC with an 80~275VAC input voltage range and a -10°C
to +70°C operating temperature. This series meets FCC Part-18 Class B and CISPR-11
EN55011 Class B Emission Limits and has ANSI/AAMI ES 60601-1: 2005 (UL/cUL 3rd edition)
and CE safety approvals. All units are RoHS and Energy Star Level V compliant. Plugs come
in United States (“U” suffix), Europe (“E” suffix), Australia (“A” suffix), and United Kingdom
(“K” suffix) types. Plugs are sold separately so please contact factory for ordering details.
AC Plug Types:
Applications:
• Home Healthcare Equipment
• Patient Monitors
• Unites States (“U” Suffix)
• Europe (“E” Suffix)
• Australia (“A” Suffix”)
• United Kingdom (“K” Suffix) • Portable Medical Devices
• ECG Machines
• Blood Pressure Systems
MODEL SELECTION TABLE
Adjustable Voltage Range Adjustable Current Range
Maximum
Output Power
Total
Regulation
No Load
Consumption
Model Number (1) Input Voltage
Ripple & Noise
Efficiency
Min
Max
Min
Max
WMIHPU15-101x
WMIHPU15-102x
WMIHPU15-103x
WMIHPU15-104x
WMIHPU15-105x
3.0 VDC
4.99 VDC
1.44 A
2.40 A
7.2W
12W
12W
13.5W
15W
15W
15W
15W
15W
15W
15W
15W
66mVp-p
50mVp-p
70mVp-p
90mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
5%
5%
5%
5%
5%
5%
5%
5%
3%
3%
3%
3%
65%
80%
82%
83%
84%
85%
85%
86%
86%
86%
86%
86%
0.2W
0.3W
0.3W
0.3W
0.3W
0.3W
0.3W
0.3W
0.3W
0.3W
0.3W
0.3W
5.0 VDC
6.5 VDC
5.99 VDC
8.0 VDC
2.00 A
1.50 A
1.22 A
1.15 A
0.94 A
0.72 A
0.55 A
0.45 A
0.37 A
0.32 A
0.28 A
2.40 A
1.84 A
1.68 A
1.36 A
1.15 A
0.94 A
0.72 A
0.55 A
0.45 A
0.37 A
0.32 A
8.0 VDC
11.0 VDC
13.0 VDC
16.0 VDC
21.0 VDC
27.0 VDC
33.0 VDC
40.0 VDC
48.0 VDC
55.0 VDC
11.0 VDC
13.0 VDC
16.0 VDC
21.0 VDC
27.0 VDC
33.0 VDC
40.0 VDC
48.0 VDC
WMIHPU15-106x
80 ~ 275VAC
WMIHPU15-107x
WMIHPU15-108x
WMIHPU15-109x
WMIHPU15-110x
WMIHPU15-111x
WMIHPU15-112x
NOTES
1. The “x” in the model number can be “U” for United States type plug; “E” for Europe type plug, “A” for Australia type plug, or “K” for United Kingdom type
plug. Plugs are sold separately so please contact factory for ordering details.
2. Output can provide up to peak load when power supply starts up. Continuous staying in more than rated load is not allowed.
3. At factory, in 60% rated load condition, each output is checked to be within voltage accuracy.
4. Line regulation is defined by changing 10% of input voltage from nominal line at rated load.
5. Load regulation is defined by changing 40% of measured output load from 60% rated load.
6. Ripple & noise is measured by using 20MHz limited bandwidth and with 0.47F capacitor in parallel across the output at nominal line and rated load.
7. Hold-up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated
load and nominal line.
8. Optional output connectors are available for this series. Please call factory for ordering details.
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
08/04/2014
Page 1 of 4
website: www.wallindustries.com • e-mail: sales@wallindustries.com
WMIHPU15 SERIES
Up to 15 Watts, Medical AC/DC Wall Mount Power Supplies
Rev A
Wall Industries, Inc.
TECHNICAL SPECIFICATIONS: WMIHPU15 SERIES
All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
Unit
INPUT SPECIFICATIONS
Safety Approvals Input Voltage Range
Derating linearly from 100% load at 90VAC to 80% load at 80VAC
Sine wave
100VAC, full load
240VAC, full load
100VAC, full load, 25°C, cold start
240VAC, full load, 25°C, cold start
230VAC, no load
100
80
47
240
275
63
0.6
0.4
35
Input Voltage
Input Frequency
Input Current
VAC
Hz
A
Inrush Current
A
85
No Load Power Consumption
OUTPUT SPECIFICATIONS
Output Voltage
See Table
See Table
Line Regulation
Total Regulation
Output Power
Output Current
See Note 4
See Note 5
1
%
See Table
See Table
See Table
See Table
Ripple & Noise (peak to peak)
Hold-up Time
Start-up Time
Transient Response Time
Temperature Coefficient
PROTECTION
Short Circuit Protection
Over Load Protection
GENERAL SPECIFICATIONS
Efficiency
See Note 6
See Note 7
100~240VAC, full load
110VAC, Full load
12
0.3
ms
s
ms
%/°C
2
4
-0.04
110
+0.04
Auto-recovery
150
Recovers automatically after fault condition is removed
%
Nominal line and rated load
See Table
Dielectric Withstanding Voltage
Protection Classes
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Primary to Secondary, limit current <10mA
5656
VDC
Double insulated, Class II
Derating linearly from 100% Load at 40°C to 50% load at 70°C
10~95% RH
Non-condensing
-10
-40
0
+70
+85
95
95
°C
°C
%RH
%RH
0
Cooling
Flammability Rating
Vibration
Operating Altitude (Elevation)
MTBF
Free air convection
UL94V-1
10~500Hz, 10min./1cycle, 60 min each along X, Y, Z axes
MIL-HDBK-217F, 25°C
5
G
m
hours
3000
100,000
PHYSICAL SPECIFICATIONS
Weight
5.82oz (165g)
Dimensions (L x W x H)
2.36 x 1.71 x 1.58 inches (60.0 x 43.5 x 40.2 mm)
“U” suffix
“K” suffix
“E” suffix
“A” suffix
United States
United Kingdom
Europe
AC Plug
Australia
Output Connector
Several options available
SAFETY, EMC, & COMPLIANCE
ANSI/AAMI ES 60601-1:2005 (UL/cUL 3rd ed.)
Safety Approvals
IEC60601-1 3rd edition
CE
EMC Emission
Surge Voltage
Compliance to EN55011 (CISPR11), EN61000-3-2,-3
B
2
8
6
Class
kV
Air Discharge, IEC61000-4-2
Contact Discharge, IEC61000-4-2
Electro Static Discharge
kV
Compliance
CEC & Energy Star
RoHS Compliant
CEC and Energy Star 2.0, Efficiency Level V
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
08/04/2014
Page 2 of 4
WMIHPU15 SERIES
Up to 15 Watts, Medical AC/DC Wall Mount Power Supplies
Rev A
Wall Industries, Inc.
DERATING
Input Voltage Derating Curve
Temperature Derating Curve
110
100
90
110
100
90
80
70
60
50
40
30
20
10
0
80
70
60
50
80
100
120
140
160
180
200
220
240
260
280
-10
0
10
20
30
40
50
60
70
80
Input Voltage (VAC)
Temperature (°C)
MECHANICAL DRAWING
1.71±±.±0 [03.5±1.±]
United States Type
(Suffix“U”)
OPTIONAL
1.58±±.±0 [0±.2±1.±]
United Kingdom Type
(Suffix“K”)
Europe Type
(Suffix“E”)
NOTES:
1. Unit: inches [mm]
2.Tolerance: ±±.±0 [±1.±]
3.Weight: 5.82oz (165g)
AustraliaType
(Suffix“A”)
0. Models WMIHPU15-1±1~1±0 need to use AWG#18/0FT output cable in order to meet the total regulation specified.
Models WMIHPU15-1±5~1±9 need to use AWG#2±/0FT output cable in order to meet the total regulation specified.
Models WMIHPU15-11±~112 need to use AWG#22/0FT output cable in order to meet the total regulation specified.
The technical specifications will change if a different output cable is used.
5. Plugs are sold separately. Please call factory for ordering details.
6. Optional output connectors available. Please call factory for ordering details.
7. All dimensions are for reference only.
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
08/04/2014
Page 3 of 4
WMIHPU15 SERIES
Up to 15 Watts, Medical AC/DC Wall Mount Power Supplies
Rev A
Wall Industries, Inc.
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will
provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one
example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its
customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing
support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
(603)778-2300
(888)597-9255
(603)778-9797
E-mail:
Web:
Address:
sales@wallindustries.com
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
08/04/2014
Page 4 of 4
相关型号:
©2020 ICPDF网 联系我们和版权申明