W77E516-25 [WINBOND]
8-BIT MICROCONTROLLER; 8位微控制器型号: | W77E516-25 |
厂家: | WINBOND |
描述: | 8-BIT MICROCONTROLLER |
文件: | 总85页 (文件大小:702K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Preliminary W77E516
8-BIT MICROCONTROLLER
Table of Contents-
1. GENERAL DESCRIPTION...........................................................................................................................3
2. FEATURES..................................................................................................................................................3
3. PIN CONFIGURATIONS..............................................................................................................................4
4. PIN DESCRIPTION......................................................................................................................................5
5. BLOCK DIAGRAM .......................................................................................................................................6
6. FUNCTIONAL DESCRIPTION.....................................................................................................................7
I/O Ports.....................................................................................................................................................7
Serial I/O....................................................................................................................................................7
Timers........................................................................................................................................................8
Interrupts....................................................................................................................................................8
Data Pointers.............................................................................................................................................8
Power Management...................................................................................................................................8
On-chip Data SRAM ..................................................................................................................................8
7. MEMORY ORGANIZATION.........................................................................................................................8
Program Memory .......................................................................................................................................8
Data Memory .............................................................................................................................................9
Special Function Registers......................................................................................................................10
Special Function Registers......................................................................................................................11
Instruction ................................................................................................................................................34
Instruction Timing ....................................................................................................................................41
Power Management.................................................................................................................................49
Reset Conditions .....................................................................................................................................51
Reset State..............................................................................................................................................52
Interrupts..................................................................................................................................................53
8. PROGRAMMABLE TIMERS/COUNTERS.................................................................................................56
Timer/Counters 0 & 1...............................................................................................................................56
Time-base Selection................................................................................................................................57
Timer/Counter 2.......................................................................................................................................59
Watchdog Timer ......................................................................................................................................62
Serial Port................................................................................................................................................64
Framing Error Detection ..........................................................................................................................70
Multiprocessor Communications..............................................................................................................70
Publication Release Date: August 16, 2002
- 1 -
Revision A1
Preliminary W77E516
9. TIMED ACCESS PROTECTION................................................................................................................71
10. ABSOLUTE MAXIMUM RATINGS...........................................................................................................72
11. AC CHARACTERISTICS .........................................................................................................................74
External Clock Characteristics.................................................................................................................74
AC Specification ......................................................................................................................................74
MOVX Characteristics Using Strech Memory Cycles..............................................................................75
12. TIMING WAVEFORMS............................................................................................................................76
Program Memory Read Cycle..................................................................................................................76
Data Memory Read Cycle........................................................................................................................77
Data Memory Write Cycle........................................................................................................................77
13. TYPICAL APPLICATION CIRCUITS........................................................................................................78
Expanded External Program Memory and Crystal...................................................................................78
Expanded External Data Memory and Oscillator.....................................................................................79
14. PACKAGE DIMENSIONS........................................................................................................................79
40-pin DIP................................................................................................................................................79
44-pin PLCC ............................................................................................................................................80
44-pin QFP ..............................................................................................................................................80
15. APPLICATION NOTE...............................................................................................................................81
In-system Programming Software Examples...........................................................................................81
- 2 -
Preliminary W77E516
1. GENERAL DESCRIPTION
The W77E516 is a fast 8051 compatible microcontroller with a redesigned processor core without
wasted clock and memory cycles. As a result, it executes every 8051 instruction faster than the original
8051 for the same crystal speed. Typically, the instruction executing time of W77E516 is 1.5 to 3 times
faster then that of traditional 8051, depending on the type of instruction. In general, the overall
performance is about 2.5 times better than the original for the same crystal speed. Giving the same
throughput with lower clock speed, power consumption has been improved. Consequently, the
W77E516 is a fully static CMOS design; it can also be operated at a lower crystal clock. The W77E516
contains In-System Programmable (ISP) 64 KB Flash EPROM; 4KB auxiliary Flash EPROM for loader
program; operating voltage from 4.5V to 5.5V; on-chip 1 KB MOVX SRAM; three power saving modes.
2. FEATURES
· 8-bit CMOS microcontroller
· High speed architecture of 4 clocks/machine cycle runs up to 40 MHz
· Pin compatible with standard 80C52
· Instruction-set compatible with MCS-51
· 64KB on-chip Mask-ROM
· Four 8-bit I/O Ports
· One extra 4-bit I/O port and Wait State control signal (available on 44-pin PLCC/QFP package)
· Three 16-bit Timers
· 12 interrupt sources with two levels of priority
· On-chip oscillator and clock circuitry
· Two enhanced full duplex serial ports
·
64KB In-System Programmable Flash EPROM (APROM)
· 4KB Auxiliary Flash EPROM for loader program (LDROM)
· 256 bytes scratch-pad RAM
· 1KB on-chip SRAM for MOVX instruction
· Programmable Watchdog Timer
· Dual 16-bit Data Pointers
· Software programmable access cycle to external RAM/peripherals
· Packages:
- DIP 40: W77E516-25/40
- PLCC 44: W77E516P-25/40
- QFP 44: W77E516F-25/40
Publication Release Date: August 16, 2002
Revision A1
- 3 -
Preliminary W77E516
3. PIN CONFIGURATIONS
40-Pin DIP (W77E516)
1
VDD
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
T2, P1.0
T2EX, P1.1
RXD1, P1.2
TXD1, P1.3
2
P0.0, AD0
P0.1, AD1
P0.2, AD2
P0.3, AD3
P0.4, AD4
P0.5, AD5
P0.6, AD6
P0.7, AD7
3
4
INT2, P1.4
5
6
INT3, P1.5
INT4, P1.6
INT5, P1.7
RST
7
8
9
10
11
12
13
14
15
16
17
18
19
20
RXD, P3.0
TXD, P3.1
INT0, P3.2
EA
ALE
PSEN
P2.7, A15
INT1, P3.3
T0, P3.4
T1, P3.5
P2.6, A14
P2.5, A13
P2.4, A12
P2.3, A11
P2.2, A10
P2.1, A9
WR, P3.6
RD, P3.7
XTAL2
XTAL1
VSS
P2.0, A8
44-Pin PLCC (W77E516P)
44-Pin QFP (W77E516F)
I
T
X
D
1
,
R
X
D
T
2
E
X
,
R
X
D
1
,
N
T
2
,
T
2
E
X
,
A
D
1
,
A
D
2
,
A
D
3
,
I
T
X
D
A
D
0
,
A
D
1
,
A
D
2
,
A
D
3
,
T
2
,
N
T
2
,
A
D
0
,
T
2
,
1
,
1
P
4
.
P
1
.
P
P
1
.
P
1
.
P
1
.
P
0
.
P
0
.
P
0
.
P
0
.
,
P
P
1
.
P
1
.
P
1
.
P
1
.
P
0
.
P
0
.
P
0
.
1
.
3
V
D
D
P
0
.
P
4
.
1
.
V
D
D
2
4
2
1
0
0
1
2
3
4
3
2
1
0
0
1
2
3
2
34
33
43 42 41 40 39 38 37 36
44
35
40
39
6
5
4
3
2
1 44 43 42
41
P0.4, AD4
P0.5, AD5
P0.6, AD6
P0.7, AD7
1
2
7
8
9
INT3, P1.5
INT3, P1.5
INT4, P1.6
INT5, P1.7
RST
P0.4, AD4
P0.5, AD5
P0.6, AD6
P0.7, AD7
32
31
30
29
28
27
26
25
INT4, P1.6
38
37
36
35
34
33
32
31
3
4
5
6
7
8
9
INT5, P1.7
RST
10
11
12
13
14
15
RXD, P3.0
P4.3
TXD, P3.1
EA
P4.1
ALE
RXD, P3.0
P4.3
EA
P4.1
ALE
TXD, P3.1
INT0, P3.2
INT1, P3.3
T0, P3.4
T1, P3.5
INT0, P3.2
INT1, P3.3
T0, P3.4
PSEN
P2.7, A15
PSEN
P2.7, A15
P2.6, A14
P2.5, A13
10
11
12
24
23
P2.6, A14
P2.5, A13
16
17
30
29
T1, P3.5
13 14 15 16 17 18 19 20 21 22
18 19 20 21 22 23 24 25 26 27 28
P
4
.
P
3
.
P
3
.
X
T
A
L
2
X
T
A
L
1
V
S
S
P
2
.
P
2
.
P
2
.
P
2
.
P
2
.
P
4
.
P
3
.
P
3
.
X
T
A
L
2
X
T
A
L
1
V
S
S
P
2
.
P
2
.
P
2
.
P
2
.
P
2
.
0
,
6
,
7
,
0
,
1
,
2
,
3
,
4
,
0
,
6
,
7
,
0
,
1
,
3
,
4
,
2
,
/
/
/
A
8
A
9
A
1
0
A
1
1
A
1
2
/
/
/
A
8
A
9
A
1
0
A
1
1
A
1
2
W
A
I
W R
W
A
I
W R
R
D
R
D
T
T
- 4 -
Preliminary W77E516
4. PIN DESCRIPTION
SYMBOL TYPE
DESCRIPTIONS
EXTERNAL ACCESS ENABLE: It should be kept high for internal program
access..
I
O
O
I
EA
PROGRAM STORE ENABLE: PSEN enables the external ROM data onto
the Port 0 address/data bus during fetch and MOVC operations.
PSEN
ALE
ADDRESS LATCH ENABLE: ALE is used to enable the address latch that
separates the address from the data on Port 0.
RESET: A high on this pin for two machine cycles while the oscillator is running
resets the device.
RST
CRYSTAL1: This is the crystal oscillator input. This pin may be driven by an
external clock.
XTAL1
I
XTAL2
VSS
O
I
CRYSTAL2: This is the crystal oscillator output. It is the inversion of XTAL1.
GROUND: Ground potential
VDD
I
POWER SUPPLY: Supply voltage for operation.
PORT 0: Port 0 is an open-drain bi-directional I/O port. This port also provides
a multiplexed low order address/data bus during accesses to external memory.
I/O
I/O
I/O
P0.0 - P0.7
P1.0 - P1.7
P2.0 - P2.7
PORT 1: Port 1 is a bi-directional I/O port with internal pull-ups. The bits have
alternate functions which are described below:
T2(P1.0): Timer/Counter 2 external count input
T2EX(P1.1): Timer/Counter 2 Reload/Capture/Direction control
RXD1(P1.2): Serial port 1 RXD
TXD1(P1.3): Serial port 1 TXD
INT2(P1.4): External Interrupt 2
INT3 (P1.5): External Interrupt 3
INT4(P1.6): External Interrupt 4
INT5 (P1.7): External Interrupt 5
PORT 2: Port 2 is a bi-directional I/O port with internal pull-ups. This port also
provides the upper address bits for accesses to external memory.
PORT 3: Port 3 is a bi-directional I/O port with internal pull-ups. All bits have
alternate functions, which are described below:
RXD(P3.0): Serial Port 0 input
TXD(P3.1): Serial Port 0 output
INT0 (P3.2): External Interrupt 0
I/O
P3.0 - P3.7
INT1(P3.3): External Interrupt 1
T0(P3.4): Timer 0 External Input
T1(P3.5): Timer 1 External Input
WR(P3.6): External Data Memory Write Strobe
RD(P3.7): External Data Memory Read Strobe
PORT 4: Port 4 is a 4-bit bi-directional I/O port. The P4.0 also provides the
alternate function WAIT which is the wait state control signal.
I/O
P4.0 - P4.3
* Note: TYPE
I: input, O: output, I/O: bi-directional.
Publication Release Date: August 16, 2002
Revision A1
- 5 -
Preliminary W77E516
5. BLOCK DIAGRAM
P1.0
Port
1
Port 1
Latch
ACC
B
Port 0
P0.0
ò
Port
0
Latch
P1.7
ò
T1 Register
T2 Register
Interrupt
DPTR
Stack
Pointer
PSW
DPTR 1
ALU
Timer
2
Temp Reg.
Address
Bus
PC
Timer
0
Incrementor
SFR RAM Address
Addr. Reg.
Timer
1
Instruction
Decoder
&
Sequencer
256 bytes
RAM & SFR
2 UARTs
P2.0
Port
2
1KB SRAM
64KB ROM
Port 2
Latch
Port 3
Latch
Port
3
Bus & lock
Controller
P3.0
ò
ò
P3.7
Port 4
Latch
Power control
P4.0
Port
4
&
ò
Power monitor
Oscillator
Reset Block
P4.3
Watchdog Timer
XTAL1 XTAL2 ALE
RST
VCC
GND
PSEN
- 6 -
Preliminary W77E516
6. FUNCTIONAL DESCRIPTION
The W77E516 is 8052 pin compatible and instruction set compatible. It includes the resources of the
standard 8052 such as four 8-bit I/O Ports, three 16-bit timer/counters, and full duplex serial port and
interrupt sources.
The W77E516 features a faster running and better performance 8-bit CPU with a redesigned core
processor without wasted clock and memory cycles. It improves the performance not just by running at
high frequency but also by reducing the machine cycle duration from the standard 8052 period of
twelve clocks to four clock cycles for the majority of instructions. This improves performance by an
average of 1.5 to 3 times. The W77E516 also provides dual Data Pointers (DPTRs) to speed up block
data memory transfers. It can also adjust the duration of the MOVX instruction (access to off-chip data
memory) between two machine cycles and nine machine cycles. This flexibility allows the W77E516 to
work efficiently with both fast and slow RAMs and peripheral devices. In addition, the W77E516
contains on-chip 1KB MOVX SRAM, the address of which is between 0000H and 03FFH. It only can
be accessed by MOVX instruction; this on-chip SRAM is optional under software control.
The W77E516 is an 8052 compatible device that gives the user the features of the original 8052
device, but with improved speed and power consumption characteristics. It has the same instruction
set as the 8051 family, with one addition: DEC DPTR (op-code A5H, the DPTR is decreased by 1).
While the original 8051 family was designed to operate at 12 clock periods per machine cycle, the
W77E516 operates at a much reduced clock rate of only 4 clock periods per machine cycle. This
naturally speeds up the execution of instructions. Consequently, the W77E516 can run at a higher
speed as compared to the original 8052, even if the same crystal is used. Since the W77E516 is a fully
static CMOS design, it can also be operated at a lower crystal clock, giving the same throughput in
terms of instruction execution, yet reducing the power consumption.
The 4 clocks per machine cycle feature in the W77E516 is responsible for a three-fold increase in
execution speed. The W77E516 has all the standard features of the 8052, and has a few extra
peripherals and features as well.
I/O Ports
The W77E516 has four 8-bit ports and one extra 4-bit port. Port 0 can be used as an Address/Data
bus when external program is running or external memory/device is accessed by MOVC or MOVX
instruction. In these cases, it has strong pull-ups and pull-downs, and does not need any external pull-
ups. Otherwise it can be used as a general I/O port with open-drain circuit. Port 2 is used chiefly as the
upper 8-bits of the Address bus when port 0 is used as an address/data bus. It also has strong pull-ups
and pull-downs when it serves as an address bus. Port 1 and 3 act as I/O ports with alternate
functions. Port 4 is only available on 44-pin PLCC/QFP package type. It serves as a general purpose
I/O port as Port 1 and Port 3. The P4.0 has an alternate function WAIT that is the wait state control
signal. When wait state control signal is enabled, P4.0 is input only.
Serial I/O
The W77E516 has two enhanced serial ports that are functionally similar to the serial port of the
original 8052 family. However the serial ports on the W77E516 can operate in different modes in order
to obtain timing similarity as well. Note that the serial port 0 can use Timer 1 or 2 as baud rate
generator, but the serial port 1 can only use Timer 1 as baud rate generator. The serial ports
have the enhanced features of Automatic Address recognition and Frame Error detection.
Publication Release Date: August 16, 2002
- 7 -
Revision A1
Preliminary W77E516
Timers
The W77E516 has three 16-bit timers that are functionally similar to the timers of the 8052 family.
When used as timers, they can be set to run at either 4 clocks or 12 clocks per count, thus providing
the user with the option of operating in a mode that emulates the timing of the original 8052. The
W77E516 has an additional feature, the watchdog timer. This timer is used as a System Monitor or as
a very long time period timer.
Interrupts
The Interrupt structure in the W77E516 is slightly different from that of the standard 8052. Due to the
presence of additional features and peripherals, the number of interrupt sources and vectors has been
increased. The W77E516 provides 12 interrupt resources with two-priority level, including six external
interrupt sources, timer interrupts, serial I/O interrupts and power-fail interrupt.
Data Pointers
The original 8052 had only one 16-bit Data Pointer (DPL, DPH). In the W77E516, there is an additional
16-bit Data Pointer (DPL1, DPH1). This new Data Pointer uses two SFR locations that were unused in
the original 8052. In addition there is an added instruction, DEC DPTR (op-code A5H), which helps in
improving programming flexibility for the user.
Power Management
Like the standard 80C52, the W77E516 also has IDLE and POWER DOWN modes of operation. The
W77E516 provides a new Economy mode that allow user to switch the internal clock rate divided by 4,
64 or 1024. In the IDLE mode, the clock to the CPU core is stopped while the timers; serial ports and
interrupts clock continue to operate. In the POWER DOWN mode, the entire clock is stopped and the
chip operation is completely stopped. This is the lowest power consumption state.
On-chip Data SRAM
The W77E516 has 1K Bytes of data space SRAM which is read/write accessible and is memory
mapped. This on-chip MOVX SRAM is reached by the MOVX instruction. It is not used for executable
program memory. There is no conflict or overlap among the 256 bytes Scratchpad RAM and the 1K
Bytes MOVX SRAM as they use different addressing modes and separate instructions. Setting the
DME0 bit in the PMR register enables the on-chip MOVX SRAM. After a reset, the DME0 bit is cleared
such that the on-chip MOVX SRAM is disabled, and all data memory spaces 0000H - FFFFH access
to the external memory.
7. MEMORY ORGANIZATION
The W77E516 separates the memory into two separate sections, the Program Memory and the Data
Memory. The Program Memory is used to store the instruction op-codes, while the Data Memory is
used to store data or for memory mapped devices.
Program Memory
The Program Memory on the W77E516 can be up to 64Kbytes long. All instructions are fetched for
execution from this memory area. The MOVC instruction can also access this memory region.
- 8 -
Preliminary W77E516
Data Memory
The W77E516 can access up to 64Kbytes of external Data Memory. This memory region is accessed
by the MOVX instructions. Unlike the 8051 derivatives, the W77E516 contains on-chip 1K bytes MOVX
SRAM of Data Memory, which can only be accessed by MOVX instructions.
These 1K bytes of SRAM are between address 0000H and 03FFH. Access to the on-chip MOVX
SRAM is optional under software control. When enabled by software, any MOVX instruction that uses
this area will go to the on-chip RAM. MOVX addresses greater than 03FFH automatically go to external
memory through Port 0 and 2. When disabled, the 1KB memory area is transparent to the system
memory map. Any MOVX directed to the space between 0000H and FFFFH goes to the expanded bus
on Port 0 and 2. This is the default condition. In addition, the W77E516 has the standard 256 bytes of
on-chip Scratchpad RAM. This can be accessed either by direct addressing or by indirect addressing.
There are also some Special Function Registers (SFRs), which can only be accessed by direct
addressing. Since the Scratchpad RAM is only 256 bytes, it can be used only when data contents are
small. In the event that larger data contents are present, two selections can be used. One is on-chip
MOVX SRAM, the other is the external Data Memory. The on-chip MOVX SRAM can only be accessed
by a MOVX instruction, the same as that for external Data Memory. However, the on-chip RAM has the
fastest access times.
FFh
FFFFh
SFRs
Direct
Addressing
Indirect
Addressing
RAM
64 K
Bytes
External
Data
Memory
64K Bytes
On-chip
Program
80h
7Fh
Direct &
Indirect
Addressing
RAM
Memory
00h
APROM
0FFFh
03FFh
0000h
4K Bytes
1K Bytes
On-chip SRAM
LDROM
0000h
Figure 1.
Memory Map
Publication Release Date: August 16, 2002
Revision A1
- 9 -
Preliminary W77E516
FFh
Indirect RAM
Direct RAM
80h
7Fh
30h
2Fh
2Eh
2Dh
2Ch
2Bh
2Ah
29h
28h
27h
26h
25h
24h
23h
22h
21h
20h
1Fh
18h
17h
10h
0Fh
08h
07h
00h
7F
77
6F
67
5F
57
4F
47
3F
37
2F
27
1F
17
0F
07
7E
76
6E
66
5E
56
4E
46
3E
36
2E
26
1E
16
0E
06
7D
75
6D
65
5D
55
4D
45
3D
35
2D
25
1D
15
0D
05
7C
74
6C
64
5C
54
4C
44
3C
34
2C
24
1C
14
0C
04
7B
73
6B
63
5B
53
4B
43
3B
33
2B
23
1B
13
0B
03
7A
72
6A
62
5A
52
4A
42
3A
32
2A
22
1A
12
0A
02
79
71
69
61
59
51
49
41
39
31
29
21
19
11
09
01
78
70
68
60
58
50
48
40
38
30
28
20
18
10
08
00
Bit Addressable
20H - 2FH
Bank 3
Bank 2
Bank 1
Bank 0
Figure 2.
Scratchpad RAM / Register Addressing
- 10 -
Preliminary W77E516
Special Function Registers
The W77E516 uses Special Function Registers (SFRs) to control and monitor peripherals and their
Modes.
The SFRs reside in the register locations 80-FFh and are accessed by direct addressing only. Some of
the SFRs are bit addressable. This is very useful in cases where one wishes to modify a particular bit
without changing the others. The SFRs that are bit addressable are those whose addresses end in 0 or
8. The W77E516 contains all the SFRs present in the standard 8052. However, some additional SFRs
have been added. In some cases unused bits in the original 8052 have been given new functions. The
list of SFRs is as follows. The table is condensed with eight locations per row. Empty locations indicate
that there are no registers at these addresses. When a bit or register is not implemented, it will read
high.
Table 1. Special Function Register Location Table
F8 EIP
F0
B
E8 EIE
E0 ACC
D8 WDCON
D0 PSW
C8 T2CON
C0 SCON1
B8 IP
T2MOD
SBUF1
SADEN
RCAP2L
WSCON
SADEN1
RCAP2H TL2
PMR
TH2
NVMCON NVMDAT
STATUS NVMSEL TA
B0 P3
A8 IE
SADDR
SADDR1
P4CSIN
P42AL
SFRAL
SFRAH
P4
SFDFD
SFRCN
A0 P2
98
90
88
80
SCON0
P1
SBUF
EXIF
TMOD
SP
P42AH
P43AL
P43AH
P40AH
TH1
CHPCON
P41AH
P4CONA P4CONB P40AL
P41AL
CKCON
DPS
TCON
P0
TL0
TL1
TH0
DPL
DPH
DPL1
DPH1
PCON
Note: The SFRs in the column with dark borders are bit-addressable.
Publication Release Date: August 16, 2002
Revision A1
- 11 -
Preliminary W77E516
A brief description of the SFRs now follows.
Port 0
Bit:
7
6
5
4
3
2
1
0
P0.7
P0.6
P0.5
P0.4
P0.3
P0.2
P0.1
P0.0
Mnemonic: P0
Address: 80h
Port 0 is an open-drain bi-directional I/O port. This port also provides a multiplexed low order
address/data bus during accesses to external memory.
Stack Pointer
Bit:
7
6
5
4
3
2
1
0
SP.7
SP.6
SP.5
SP.4
SP.3
SP.2
SP.1
SP.0
Mnemonic: SP
Address: 81h
The Stack Pointer stores the Scratchpad RAM address where the stack begins. In other words, it
always points to the top of the stack.
Data Pointer Low
Bit:
7
6
5
4
3
2
1
0
DPL.7 DPL.6 DPL.5 DPL.4
DPL.3 DPL.2
DPL.1 DPL.0
Mnemonic: DPL
Address: 82h
This is the low byte of the standard 8052 16-bit data pointer.
Data Pointer High
Bit:
7
6
5
4
3
2
1
0
DPH.7 DPH.6 DPH.5 DPH.4 DPH.3 DPH.2 DPH.1 DPH.0
Mnemonic: DPH
Address: 83h
This is the high byte of the standard 8052 16-bit data pointer.
Data Pointer Low1
Bit:
7
6
5
4
3
2
1
0
DPL1.7 DPL1.6 DPL1.5 DPL1.4 DPL1.3 DPL1.2 DPL1.1 DPL1.0
Mnemonic: DPL1
Address: 84h
This is the low byte of the new additional 16-bit data pointer that has been added to the W77E516.
The user can switch between DPL, DPH and DPL1, DPH1 simply by setting register DPS = 1. The
instructions that use DPTR will now access DPL1 and DPH1 in place of DPL and DPH. If they are
not required they can be used as conventional register locations by the user.
- 12 -
Preliminary W77E516
Data Pointer High1
Bit:
7
6
5
4
3
2
1
0
DPH1.7 DPH1.6 DPH1.5 DPH1.4 DPH1.3 DPH1.2 DPH1.1 DPH1.0
Mnemonic: DPH1 Address: 85h
This is the high byte of the new additional 16-bit data pointer that has been added to the W77E516.
The user can switch between DPL, DPH and DPL1, DPH1 simply by setting register DPS = 1. The
instructions that use DPTR will now access DPL1 and DPH1 in place of DPL and DPH. If they are
not required they can be used as conventional register locations by the user.
Data Pointer Select
Bit:
7
-
6
-
5
-
4
-
3
-
2
-
1
-
0
DPS.0
Mnemonic: DPS
Address: 86h
DPS.0: This bit is used to select either the DPL, DPH pair or the DPL1, DPH1 pair as the
activeData Pointer. When set to 1, DPL1, DPH1 will be selected, otherwise DPL, DPH will
be selected.
DPS.1 - 7: These bits are reserved, but will read 0.
Power Control
Bit:
7
6
5
-
4
-
3
2
1
0
SMOD0
SM0D
GF1
GF0
PD
IDL
Mnemonic: PCON
Address: 87h
SMOD : This bit doubles the serial port baud rate in mode 1, 2, and 3 when set to 1.
SMOD0: Framing Error Detection Enable: When SMOD0 is set to 1, then SCON.7(SCON1.7)
indicates a Frame Error and acts as the FE(FE_1) flag. When SMOD0 is 0, then
SCON.7(SCON1.7) acts as per the standard 8052 function.
GF1-0: These two bits are general purpose user flags.
PD: Setting this bit causes the W77E516 to go into the POWER DOWN mode. In this mode all the
clocks are stopped and program execution is frozen.
IDL: Setting this bit causes the W77E516 to go into the IDLE mode. In this mode the clocks to the
CPU are stopped, so program execution is frozen. But the clock to the serial, timer and
interrupt blocks is not stopped, and these blocks continue operating.
Timer Control
Bit:
7
6
5
4
3
2
1
0
TF1
TR1
TF0
TR0
IE1
IT1
IE0
IT0
Mnemonic: TCON
Address: 88h
Publication Release Date: August 16, 2002
Revision A1
- 13 -
Preliminary W77E516
TF1: Timer 1 overflow flag: This bit is set when Timer 1 overflows. It is cleared automatically when
the program does a timer 1 interrupt service routine. Software can also set or clear this bit.
TR1: Timer 1 run control: This bit is set or cleared by software to turn timer/counter on or off.
TF0: Timer 0 overflow flag: This bit is set when Timer 0 overflows. It is cleared automatically when
the program does a timer 0 interrupt service routine. Software can also set or clear this bit.
TR0: Timer 0 run control: This bit is set or cleared by software to turn timer/counter on or off.
IE1: Interrupt 1 edge detect: Set by hardware when an edge/level is detected on INT1. This bit is
cleared by hardware when the service routine is vectored to only if the interrupt was edge
triggered. Otherwise it follows the pin.
IT1: Interrupt 1 type control: Set/cleared by software to specify falling edge/ low level triggered
external inputs.
IE0: Interrupt 0 edge detect: Set by hardware when an edge/level is detected on INT0 . This bit is
cleared by hardware when the service routine is vectored to only if the interrupt was edge
triggered. Otherwise it follows the pin.
IT0: Interrupt 0 type control: Set/cleared by software to specify falling edge/ low level triggered
external inputs.
Timer Mode Control
Bit:
7
6
5
4
3
2
1
0
GATE
M1
M0
GATE
M1
M0
C / T
C / T
TIMER1
TIMER0
Address: 89h
Mnemonic: TMOD
GATE: Gating control: When this bit is set, Timer/counter x is enabled only while INTx pin is
high and TRx control bit is set. When cleared, Timer x is enabled whenever TRx control bit
is set.
C / T : Timer or Counter Select: When cleared, the timer is incremented by internal clocks. When
set, the timer counts high-to-low edges of the Tx pin.
- 14 -
Preliminary W77E516
M1, M0: Mode Select bits:
M1
0
M0 Mode
0
1
0
1
Mode 0: 8-bits with 5-bit prescale.
0
Mode 1: 18-bits, no prescale.
1
Mode 2: 8-bits with auto-reload from THx
1
Mode 3: (Timer 0) TL0 is an 8-bit timer/counter controlled by the standard Timer 0
control bits. TH0 is a 8-bit timer only controlled by Timer 1 control bits. (Timer 1)
Timer/counter is stopped.
Timer 0 LSB
Bit:
7
6
5
4
3
2
1
0
TL0.7
TL0.6
TL0.5
TL0.4
TL0.3
TL0.2
TL0.1
TL0.0
Mnemonic: TL0
TL0.7 - 0: Timer 0 LSB
Address: 8Ah
Timer 1 LSB
Bit:
7
6
5
4
3
2
TL1.2
1
0
TL1.7
TL1.6
TL1.5
TL1.4
TL1.3
TL1.1
TL1.0
Mnemonic: TL1
TL1.7 - 0: Timer 1 LSB
Address: 8Bh
Timer 0 MSB
Bit:
7
6
5
4
3
2
TH0.2
1
0
TH0.7
TH0.6
TH0.5
TH0.4
TH0.3
TH0.1
TH0.0
Mnemonic: TH0
TH0.7 - 0: Timer 0 MSB
Address: 8Ch
Timer 1 MSB
Bit:
7
6
5
4
3
2
TH1.2
1
0
TH1.7
TH1.6
TH1.5
TH1.4
TH1.3
TH1.1
TH1.0
Mnemonic: TH1
TH1.7 - 0: Timer 1 MSB
Address: 8Dh
Publication Release Date: August 16, 2002
Revision A1
- 15 -
Preliminary W77E516
Clock Control
Bit:
7
6
5
4
3
2
1
0
WD1
WD0
T2M
T1M
T0M
MD2
MD1
MD0
Mnemonic: CKCON
Address: 8Eh
WD1 - 0: Watchdog timer mode select bits: These bits determine the time-out period for the
watchdog timer. In all four time-out options the reset time-out is 512 clocks more than
the interrupt time-out period.
WD1 WD0 Interrupt time-out
Reset time-out
17
17
0
0
1
1
0
1
0
1
2
2
2
2
2
2
2
2
+ 512
+ 512
+ 512
+ 512
20
23
26
20
23
26
T2M: Timer 2 clock select: When T2M is set to 1, timer 2 uses a divide by 4 clock, and when set to
0 it uses a divide by 12 clock.
T1M: Timer 1 clock select: When T1M is set to 1, timer 1 uses a divide by 4 clock, and when set to
0 it uses a divide by 12 clock.
T0M: Timer 0 clock select: When T0M is set to 1, timer 0 uses a divide by 4 clock, and when set to
0 it uses a divide by 12 clock.
MD2 - 0: Stretch MOVX select bits: These three bits are used to select the stretch value for the
MOVXinstruction. Using a variable MOVX length enables the user to access slower
external memorydevices or peripherals without the need for external circuits. The RD
or WR strobe will be stretched by the selected interval. When accessing the on-chip
SRAM, the MOVX instruction is always in 2 machine cycles regardless of the stretch
setting. By default, the stretch has value of 1. If the user needs faster accessing, then a
stretch value of 0 should be selected.
MD2
MD1
MD0
Stretch value MOVX duration
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
2
3
4
5
6
7
2 machine cycles
3 machine cycles (Default)
4 machine cycles
5 machine cycles
6 machine cycles
7 machine cycles
8 machine cycles
9 machine cycles
- 16 -
Preliminary W77E516
Port 1
Bit:
7
6
5
4
3
2
1
0
P1.7
P1.6
P1.5
P1.4
P1.3
P1.2
P1.1
P1.0
Mnemonic: P1
Address: 90h
P1.7 - 0: General purpose I/O port. Most instructions will read the port pins in case of a port read
access, however in case of read-modify-write instructions, the port latch is read. Some
pins also have alternate input or output functions. This alternate functions are described
below:
P1.0: T2
External I/O for Timer/Counter 2
Timer/Counter 2 Capture/Reload Trigger
Serial Port 1 Receive
Serial Port 1 Transmit
External Interrupt 2
P1.1: T2EX
P1.2: RXD1
P1.3: TXD1
P1.4: INT2
P1.5: INT3
P1.6: INT4
External Interrupt 3
External Interrupt 4
P1.7: INT5
External Interrupt 5
External Interrupt Flag
Bit:
7
6
5
4
3
-
2
-
1
-
0
-
IE5
IE4
IE3
IE2
Mnemonic: EXIF
Address: 91h
IE5: External Interrupt 5 flag. Set by hardware when a falling edge is detected on INT5 .
IE4: External Interrupt 4 flag. Set by hardware when a rising edge is detected on INT4.
IE3: External Interrupt 3 flag. Set by hardware when a falling edge is detected on INT3 .
IE2: External Interrupt 2 flag. Set by hardware when a rising edge is detected on INT2.
Port 4 Control Register A
Bit:
7
6
5
4
3
2
1
0
P41M1 P41M0 P41C1 P41C0 P40M1 P40M0 P40C1 P40C0
Mnemonic: P4CONA
Address: 92h
2
Port 4 Control Register B
Bit:
7
6
5
4
3
1
0
P43M1 P43M0 P43C1 P43C0 P42M1 P42M0 P42C1 P42C0
Mnemonic: P4CONB
Address: 93h
Publication Release Date: August 16, 2002
Revision A1
- 17 -
Preliminary W77E516
BIT NAME
FUNCTION
P4xM1, P4xM0 Port 4 alternate modes.
= 00: Mode 0. P4.x is a general purpose I/O port which is the same as Port 1.
= 01: Mode 1. P4.x is a Read Strobe signal for chip select purpose. The
address range depends on the SFR P4xAH, P4xAL and bits P4xC1, P4xC0.
= 10: Mode 2. P4.x is a Write Strobe signal for chip select purpose. The
address range depends on the SFR P4xAH, P4xAL and bits P4xC1, P4xC0.
= 11: Mode 3. P4.x is a Read/Write Strobe signal for chip select purpose.
The address range depends on the SFR P4xAH, P4xAL and bits P4xC1,
P4xC0
P4xC1, P4xC0 Port 4 Chip-select Mode address comparison:
= 00: Compare the full address (16 bits length) with the base address registers
P4xAH and P4xAL.
= 01: Compare the 15 high bits (A15 - A1) of address bus with the base
address registers P4xAH and P4xAL.
= 10: Compare the 14 high bits (A15 - A2) of address bus with the base
address registers P4xAH and P4xAL.
= 11: Compare the 8 high bits (A15 - A8) of address bus with the base
address registers P4xAH and P4xAL.
P4.0 Base Address Low Byte Register
Bit:
7
6
5
4
3
2
1
0
A7
A6
A5
A4
A3
A2
A1
A0
Mnemonic: P40AL
Address: 94h
P4.0 Base Address High Byte Register
Bit:
7
6
5
4
3
2
1
0
A15
A14
A13
A12
A11
A10
A9
A8
Mnemonic: P40AH
Address: 95h
P4.1 Base Address Low Byte Register
Bit:
7
6
5
4
3
2
1
0
A7
A6
A5
A4
A3
A2
A1
A0
Mnemonic: P41AL
Address: 96h
- 18 -
Preliminary W77E516
P4.1 Base Address High Byte Register
Bit:
7
6
5
4
3
2
1
0
A15
A14
A13
A12
A11
A10
A9
A8
Mnemonic: P41AH
Address: 97h
Serial Port Control
Bit:
7
6
5
4
3
2
1
0
SM0/FE
SM1
SM2
REN
TB8
RB8
TI
RI
Mnemonic: SCON
Address: 98h
SM0/FE: Serial port 0, Mode 0 bit or Framing Error Flag: The SMOD0 bit in PCON SFR determines
whether this bit acts as SM0 or as FE. The operation of SM0 is described below. When
used as FE, this bit will be set to indicate an invalid stop bit. This bit must be manually
cleared in software to clear the FE condition.
SM1: Serial port Mode bit 1:
SM0
SM1
Mode Description
Length
8
10
11
11
Baud rate
4/12 Tclk
Variable
64/32 Tclk
Variable
0
0
1
1
0
1
0
1
0
1
2
3
Synchronous
Asynchronous
Asynchronous
Asynchronous
SM2: Multiple processors communication. Setting this bit to 1 enables the multiprocessor
communication feature in mode 2 and 3. In mode 2 or 3, if SM2 is set to 1, then RI will not be
activated if the received 9th data bit (RB8) is 0. In mode 1, if SM2 = 1, then RI will not be
activated if a valid stop bit was not received. In mode 0, the SM2 bit controls the serial port
clock. If set to 0, then the serial port runs at a divide by 12 clock of the oscillator. This gives
compatibility with the standard 8052. When set to 1, the serial clock become divide by 4 of the
oscillator clock.
This results in faster synchronous serial communication.
REN: Receive enable: When set to 1 serial reception is enabled, otherwise reception is disabled.
TB8: This is the 9th bit to be transmitted in modes 2 and 3. This bit is set and cleared by software
as desired.
RB8: In modes 2 and 3 this is the received 9th data bit. In mode 1, if SM2 = 0, RB8 is the stop bit
that was received. In mode 0 it has no function.
TI: Transmit interrupt flag: This flag is set by hardware at the end of the 8th bit time in mode 0, or
at the beginning of the stop bit in all other modes during serial transmission. This bit must be
cleared by software.
RI: Receive interrupt flag: This flag is set by hardware at the end of the 8th bit time in mode 0, or
halfway through the stop bits time in the other modes during serial reception. However the
restrictions of SM2 apply to this bit. This bit can be cleared only by software.
Publication Release Date: August 16, 2002
- 19 -
Revision A1
Preliminary W77E516
Serial Data Buffer
Bit:
7
6
5
4
3
2
1
0
SBUF.7 SBUF.6 SBUF.5 SBUF.4 SBUF.3 SBUF.2 SBUF.1 SBUF.0
Mnemonic: SBUF Address: 99h
SBUF.7 - 0: Serial data on the serial port 0 is read from or written to this location. It actually
consists of two separate internal 8-bit registers. One is the receive resister, and the
other is the transmit buffer. Any read access gets data from the receive data buffer,
while write access is to the transmit data buffer.
P4.2 Base Address Low Byte Register
Bit:
7
6
5
4
3
2
1
0
A7
A6
A5
A4
A3
A2
A1
A0
Mnemonic: P42AL
Address: 9Ah
P4.2 Base Address High Byte Register
Bit:
7
6
5
4
3
2
1
0
A15
A14
A13
A12
A11
A10
A9
A8
Mnemonic: P42AH
Address: 9Bh
P4.3 Base Address Low Byte Register
Bit:
7
6
5
4
3
2
1
0
A7
A6
A5
A4
A3
A2
A1
A0
Mnemonic: P43AL
Address: 9Ch
P4.3 Base Address High Byte Register
Bit:
7
6
5
4
3
2
1
0
A15
A14
A13
A12
A11
A10
A9
A8
Mnemonic: P43AH
Address: 9Dh
ISP Control Register
Bit:
7
6
5
4
-
3
-
2
1
0
SWRST/HWB
Mnemonic: CHPCON
-
LDAP
-
LDSEL
ENP
Address: 9Fh
SWRST/HWB: Set this bit to launch a whole device reset that is same as asserting high to RST pin,
micro controller will be back to initial state and clear this bit automatically. To read
this bit, its alternate function to indicate the ISP hardware reboot mode is invoking
when read it in high.
- 20 -
Preliminary W77E516
LDAP: This bit is Read Only. High: device is executing the program in LDROM. Low: device is
executing the program in APROM.
LDSEL: Loader program residence selection. Set to high to route the device fetching code from
LDROM.
ENP: In System Programming Mode Enable. Set this be to launch the ISP mode. Device will
operate ISP procedures, such as Erase, Program and Read operations, according to
correlative SFRs settings. During ISP mode, device achieves ISP operations by the way of
IDLE state. In the other words, device is not indeed in IDLE mode is set bit PCON.1 while ISP
is enabled. Clear this bit to disable ISP mode, device get back to normal operation including
IDLE state.
Port 2
Bit:
7
6
5
4
3
2
1
0
P2.7
P2.6
P2.5
P2.4
P2.3
P2.2
P2.1
P2.0
Mnemonic: P2
Address: A0h
P2.7 - 0: Port 2 is a bi-directional I/O port with internal pull-ups. This port also provides the upper
address bits for accesses to external memory.
Port 4 Chip-Select Polarity
Bit:
7
6
5
4
3
-
2
-
1
-
0
P43INV P42INV P42INV P40INV
P0UP
Mnemonic: P4CSIN
Address: A2h
P4xINV: The active polarity of P4.x when set it as chip-select signal. High = Active High. Low =
Active Low.
PUP0: Enable Port 0 weak pull up.
Port 4
Bit:
7
-
6
-
5
-
4
-
3
2
1
0
P4.3
P4.2
P4.1
P4.0
Mnemonic: P4
Address: A5h
P4.3 - 0: Port 4 is a bi-directional I/O port with internal pull-ups. Port 4 can not use bit-addressable
instruction (SETB or CLR).
Interrupt Enable
Bit:
7
6
5
4
3
2
1
0
EA
ES1
ET2
ES
ET1
EX1
ET0
EX0
Mnemonic: IE
Address: A8h
Publication Release Date: August 16, 2002
Revision A1
- 21 -
Preliminary W77E516
EA: Global enable. Enable/disable all interrupts except for PFI.
ES1: Enable Serial Port 1 interrupt.
ET2: Enable Timer 2 interrupt.
ES: Enable Serial Port 0 interrupt.
ET1: Enable Timer 1 interrupt
EX1: Enable external interrupt 1
ET0: Enable Timer 0 interrupt
EX0: Enable external interrupt 0
Slave Address
Bit:
7
6
5
4
3
2
1
0
Mnemonic: SADDR
Address: A9h
SADDR: The SADDR should be programmed to the given or broadcast address for serial port 0 to
which the slave processor is designated.
Slave Address 1
Bit:
7
6
5
4
3
2
1
0
Mnemonic: SADDR1
Address: AAh
SADDR1: The SADDR1 should be programmed to the given or broadcast address for serial port 1
to which the slave processor is designated.
ISP Address Low Byte
Bit:
7
6
5
4
3
2
1
A1
0
A7
A6
A5
A4
A3
A2
A0
Mnemonic: SFRAL
Address: ACh
Low byte destination address for In System Programming operations. SFRAH and SFRAL address
a specific ROM bytes for erasure, porgramming or read.
ISP Address High Byte
Bit:
7
6
5
4
3
2
1
0
A15
A14
A13
A12
A11
A10
A9
A8
Mnemonic: SFRAH
Address: ADh
High byte destination address for In System Programming operations. SFRAH and SFRAL address
a specific ROM bytes for erasure, porgramming or read.
- 22 -
Preliminary W77E516
ISP Data Buffer
Bit:
7
6
5
4
3
2
1
0
D7
D6
D5
D4
D3
D2
D1
D0
Mnemonic: SFRFD
Address: AEh
In ISP mode, read/write a specific byte ROM content must go through SFRFD register.
ISP Operation Modes
Bit:
7
6
5
4
3
2
1
0
WFWIN NOE
NCE
CTRL3 CTRL2 CTRL1 CTRL0
Address: AFh
Mnemonic: SFRCN
WFWIN: Destination ROM bank for programming, erasure and read. 0 = APROM, 1 = LDROM.
NOE: Flash EPROM output enable.
NCE: Flash EPROM chip enable.
CTRL[3:0]: Mode Selection.
ISP Mode
Erase 4KB LDROM
Erase 64K APROM
Program 4KB LDROM
Program 64KB APROM
Read 4KB LDROM
Read 64KB APROM
BANK
WFWIN
NOE
NCE
CTRL<3:0> SFRAH, SFRAL
SFRFD
X
0
0
0
0
0
0
1
0
1
0
1
0
1
1
1
1
0
0
0
0
0
0
0
0
0010
0010
0001
0001
0000
0000
X
X
X
Address in
Address in
Address in
Address in
Data in
Data in
Data out
Data out
Port 3
Bit:
7
6
5
4
3
2
1
0
P3.7
Mnemonic: P3
P3.6
P3.5
P3.4
P3.3
P3.2
P3.1
P3.0
Address: B0h
P3.7 - 0: General purpose I/O port. Each pin also has an alternate input or output function. The
alternate functions are described below.
P3.7
RD
Strobe for read from external RAM
P3.6
P3.5
P3.4
WR
T1
T0
Strobe for write to external RAM
Timer/counter 1 external count input
Timer/counter 0 external count input
P3.3
INT1 External interrupt 1
INT0 External interrupt 0
P3.2
P3.1
P3.0
TxD
RxD
Serial port 0 output
Serial port 0 input
Publication Release Date: August 16, 2002
Revision A1
- 23 -
Preliminary W77E516
Interrupt Priority
Bit:
7
-
6
5
4
3
2
1
0
PS1
PT2
PS
PT1
PX1
PT0
PX0
Mnemonic: IP
IP.7:This bit is un-implemented and will read high.
PS1:This bit defines the Serial port 1 interrupt priority. PS = 1 sets it to higher priority level.
PT2:This bit defines the Timer 2 interrupt priority. PT2 = 1 sets it to higher priority level.
PS: This bit defines the Serial port 0 interrupt priority. PS = 1 sets it to higher priority level.
PT1:This bit defines the Timer 1 interrupt priority. PT1 = 1 sets it to higher priority level.
PX1:This bit defines the External interrupt 1 priority. PX1 = 1 sets it to higher priority level.
PT0:This bit defines the Timer 0 interrupt priority. PT0 = 1 sets it to higher priority level.
Address: B8h
PX0:This bit defines the External interrupt 0 priority. PX0 = 1 sets it to higher priority level.
Slave Address Mask Enable
Bit:
7
6
5
4
3
2
1
0
Mnemonic: SADEN
Address: B9h
SADEN: This register enables the Automatic Address Recognition feature of the Serial port 0.
When a bit in the SADEN is set to 1, the same bit location in SADDR will be compared
with the incoming serial data. When SADEN.n is 0, then the bit becomes a "don't care" in
the comparison. This register enables the Automatic Address Recognition feature of the
Serial port 0. When all the bits of SADEN are 0, interrupt will occur for any incoming
address.
Slave Address Mask Enable 1
Bit:
7
6
5
4
3
2
1
0
Mnemonic: SADEN1
Address: BAh
SADEN1: This register enables the Automatic Address Recognition feature of the Serial port 1.
When a bit in the SADEN1 is set to 1, the same bit location in SADDR1 will be
compared with the incoming serial data. When SADEN1.n is 0, then the bit becomes a
"don't care" in the comparison. This register enables the Automatic Address Recognition
feature of the Serial port 1. When all the bits of SADEN1 are 0, interrupt will occur for
any incoming address.
Serial Port Control 1
Bit:
7
6
5
4
3
2
1
0
SM0_1/FE_1 SM1_1
Mnemonic: SCON1
SM2_1 REN_1
TB8_1
RB8_1
TI_1
RI_1
Address: C0h
- 24 -
Preliminary W77E516
SM0_1/FE_1: Serial port 1, Mode 0 bit or Framing Error Flag 1: The SMOD0 bit in PCON SFR
determines whether this bit acts as SM0_1 or as FE_1, the operation of SM0_1 is
described below. When used as FE_1, this bit will be set to indicate an invalid stop
bit. This bit must be manually cleared in software to clear the FE_1 condition.
SM1_1: Serial port 1 Mode bit 1:
SM0_1 SM1_1
Mode
Description
Length
8
10
11
11
Baud rate
4/12 Tclk
variable
64/32 Tclk
variable
0
0
1
1
0
1
0
1
0
1
2
3
Synchronous
Asynchronous
Asynchronous
Asynchronous
SM2_1: Multiple processors communication. Setting this bit to 1 enables the multiprocessor
communication feature in mode 2 and 3. In mode 2 or 3, if SM2_1 is set to 1, then RI_1
will not be activated if the received 9th data bit (RB8_1) is 0. In mode 1, if SM2_1 = 1, then
RI_1 will not be activated if a valid stop bit was not received. In mode 0, the SM2_1 bit
controls the serial port 1 clock. If set to 0, then the serial port 1 runs at a divide by 12 clock
of the oscillator. This gives compatibility with the standard 8052. When set to 1, the serial
clock become divide by 4 of the oscillator clock. This results in faster synchronous serial
communication.
REN_1: Receive enable: When set to 1 serial reception is enabled, otherwise reception is disabled.
TB8_1: This is the 9th bit to be transmitted in modes 2 and 3. This bit is set and cleared by software
as desired.
RB8_1: In modes 2 and 3 this is the received 9th data bit. In mode 1, if SM2_1 = 0, RB8_1 is the
stop bit that was received. In mode 0 it has no function.
TI_1: Transmit interrupt flag: This flag is set by hardware at the end of the 8th bit time in mode 0, or
at the beginning of the stop bit in all other modes during serial transmission. This bit must be
cleared by software.
RI_1: Receive interrupt flag: This flag is set by hardware at the end of the 8th bit time in mode 0, or
halfway through the stop bits time in the other modes during serial reception. However the
restrictions of SM2_1 apply to this bit. This bit can be cleared only by software.
Serial Data Buffer 1
Bit:
7
6
5
4
3
2
1
0
SBUF1.7 SBUF1.6 SBUF1.5 SBUF1.4 SBUF1.3 SBUF1.2 SBUF1.1 SBUF1.0
Mnemonic: SBUF1 Address: C1h
SBUF1.7 - 0: Serial data of the serial port 1 is read from or written to this location. It actually
consists of two separate 8-bit registers. One is the receive resister, and the other is
the transmit buffer. Any read access gets data from the receive data buffer, while
write accesses are to the transmit data buffer.
WSCON
Bit:
7
6
-
5
4
-
3
-
2
-
1
-
0
-
WS
-
Mnemonic: WSCON
Address: C2h
Publication Release Date: August 16, 2002
Revision A1
- 25 -
Preliminary W77E516
WS: Wait State Signal Enable. Setting this bit enables the WAIT signal on P4.0. The device will
sample the wait state control signal WAIT via P4.0 during MOVX instruction. This bit is
time access protected.
TA
REG C7H
WSCON
CKCON
MOV
REG C2H
REG 8EH
TA, #AAH
MOV
TA, #55H
ORL
WSCON, #10000000B; Set WS bit and stretch value = 0 to enable wait signal.
Power Management Register
Bit:
7
6
5
4
-
3
-
2
1
-
0
ALE-OFF
CD1
CD0
SWB
DME0
Mnemonic: PMR
Address: C4h
CD1, CD0: Clock Divide Control. These bit selects the number of clocks required to generate one
machine cycle. There are three modes including divide by 4, 64 or 1024. Switching
between modes must first go back divide by 4 mode. For instance, to go from 64 to
1024 clocks/machine cycle the device must first go from 64 to 4 clocks/machine cycle,
and then from 4 to 1024 clocks/machine cycle.
CD1, CD0
Clocks/machine Cycle
0
0
1
1
0
1
0
1
Reserved
4
64
1024
SWB: Switchback Enable. Setting this bit allows an enabled external interrupt or serial port activity
to force the CD1, CD0 to divide by 4 state (0,1). The device will switch modes at the start of
the jump to interrupt service routine while a external interrupt is enabled and actually
recognized by micro controller. While a serial port reception, the switchback occurs at the
start of the instruction following the falling edge of the start bit.
ALE0FF: This bit disables the expression of the ALE signal on the device pin during all on-board
program and data memory accesses. External memory accesses will automatically
enable ALE independent of ALEOFF.
0 = ALE expression is enable; 1 = ALE expression is disable
DME0: This bit determines the on-chip MOVX SRAM to be enabled or disabled. Set this bit to 1 will
enable the on-chip 1KB MOVX SRAM.
- 26 -
Preliminary W77E516
Status Register
Bit:
7
-
6
5
4
3
2
1
0
HIP
LIP
XTUP
SPTA1 SPRA1 SPTA0 SPRA0
Mnemonic: STATUS
Address: C5h
HIP: High Priority Interrupt Status. When set, it indicates that software is servicing a high priority
interrupt. This bit will be cleared when the program executes the corresponding RETI
instruction.
LIP: Low Priority Interrupt Status. When set, it indicates that software is servicing a low priority
interrupt. This bit will be cleared when the program executes the corresponding RETI
instruction.
XTUP: Crystal Oscillator Warm-up Status. When set, this bit indicates CPU has detected clock to
be ready. Each time the crystal oscillator is restarted by exit from power down mode,
hardware will clear this bit. This bit is set to 1 after a power-on reset.
SPTA1: Serial Port 1 Transmit Activity. This bit is set during serial port 1 is currently transmitting
data. It is cleared when TI_1 bit is set by hardware. Changing the Clock Divide Control bits
CD0, CD1 will be ignored when this bit is set to 1 and SWB = 1.
SPRA1: Serial Port 1 Receive Activity. This bit is set during serial port 1 is currently receiving a
data. It is cleared when RI_1 bit is set by hardware. Changing the Clock Divide Control bits
CD0, CD1 will be ignored when this bit is set to 1 and SWB = 1.
SPTA0: Serial Port 0 Transmit Activity. This bit is set during serial port 0 is currently transmitting
data. It is cleared when TI bit is set by hardware. Changing the Clock Divide Control bits
CD0, CD1 will be ignored when this bit is set to 1 and SWB = 1.
SPRA0: Serial Port 0 Receive Activity. This bit is set during serial port 0 is currently receiving a
data. It is cleared when RI bit is set by hardware. Changing the Clock Divide Control bits
CD0, CD1 will be ignored when this bit is set to 1 and SWB = 1.
NVM Address Select
Bit:
7
-
6
-
5
4
3
2
1
0
DCID5
DCID4
DCID3
DCID2
DCID1
DCID0
Mnemonic: NVMSEL
Address: C6h
DCID[5:0]: 6-bit address to access individual location of on-chip 64 bytes non-volatile data memory.
For instance, asserting DCID[5:0] = 00000b addresses to the NVM 1st byte, DCID[5:0] =
11111b addresses to the NVM 64th byte.
NVM ADDRESS
DCID5
0
0
0
0
0
0
0
1
0
0
0
0
0
1
2
0
0
0
0
1
0
3
0
0
0
0
1
1
4
0
0
0
1
0
0
5
0
0
0
1
0
1
6
0
0
0
1
1
0
7
0
0
0
1
1
1
…
…
…
…
…
…
…
63
1
DCID4
1
DCID3
1
DCID2
1
DCID1
1
DCID0
1
Publication Release Date: August 16, 2002
Revision A1
- 27 -
Preliminary W77E516
Timed Access
Bit:
7
6
5
4
3
2
1
0
TA.7
TA.6
TA.5
TA.4
TA.3
TA.2
TA.1
TfA.0
Mnemonic: TA
Address: C7h
TA: The Timed Access register controls the access to protected bits. To access protected bits, the
user must first write AAH to the TA. This must be immediately followed by a write of 55H to TA.
Now a window is opened in the protected bits for three machine cycles, during which the user
can write to these bits.
Timer 2 Control
Bit:
7
6
5
4
3
2
1
0
TF2
EXF2
RCLK
TCLK EXEN2
TR2
CP / RL2
C / T2
Mnemonic: T2CON
Address: C8h
TF2: Timer 2 overflow flag: This bit is set when Timer 2 overflows. It is also set when the count is
equal to the capture register in down count mode. It can be set only if RCLK and TCLK are
both 0. It is cleared only by software. Software can also set or clear this bit.
EXF2: Timer 2 External Flag: A negative transition on the T2EX pin (P1.1) or timer 2 overflow will
cause this flag to set based on the CP / RL2 , EXEN2 and DCEN bits. If set by a negative
transition, this flag must be cleared by software. Setting this bit in software or detection of a
negative transition on T2EX pin will force a timer interrupt if enabled.
RCLK: Receive Clock Flag: This bit determines the serial port 0 time-base when receiving data in
serial modes 1 or 3. If it is 0, then timer 1 overflow is used for baud rate generation,
otherwise timer 2 overflow is used. Setting this bit forces timer 2 in baud rate generator
mode.
TCLK: Transmit Clock Flag: This bit determines the serial port 0 time-base when transmitting data
in modes 1 and 3. If it is set to 0, the timer 1 overflow is used to generate the baud rate
clock otherwise timer 2 overflow is used. Setting this bit forces timer 2 in baud rate
generator mode.
EXEN2: Timer 2 External Enable. This bit enables the capture/reload function on the T2EX pin if
Timer 2 is not generating baud clocks for the serial port. If this bit is 0, then the T2EX pin
will be ignored, otherwise a negative transition detected on the T2EX pin will result in
capture or reload.
TR2: Timer 2 Run Control. This bit enables/disables the operation of timer 2. Clearing this bit will
halt the timer 2 and preserve the current count in TH2, TL2.
C / T2 : Counter/Timer Select. This bit determines whether timer 2 will function as a timer or a
counter. Independent of this bit, the timer will run at 2 clocks per tick when used in baud
rate generator mode. If it is set to 0, then timer 2 operates as a timer at a speed
depending on T2M bit (CKCON.5), otherwise it will count negative edges on T2 pin.
- 28 -
Preliminary W77E516
CP / RL2 : Capture/Reload Select. This bit determines whether the capture or reload function will be
used for timer 2. If either RCLK or TCLK is set, this bit will be ignored and the timer will
function in an auto-reload mode following each overflow. If the bit is 0 then auto-reload
will occur when timer 2 overflows or a falling edge is detected on T2EX pin if EXEN2 =
1. If this bit is 1, then timer 2 captures will occur when a falling edge is detected on
T2EX pin if EXEN2 = 1.
Timer 2 Mode Control
Bit:
7
6
5
4
3
2
-
1
0
HC5
HC4
HC3
HC2
T2CR
T2OE
DCEN
Mnemonic: T2MOD
Address: C9h
HC5: Hardware Clear INT5 flag. Setting this bit allows the flag of external interrupt 5 to be
automatically cleared by hardware while entering the interrupt service routine.
HC4: Hardware Clear INT4 flag. Setting this bit allows the flag of external interrupt 4 to be
automatically cleared by hardware while entering the interrupt service routine.
HC3: Hardware Clear INT3 flag. Setting this bit allows the flag of external interrupt 3 to be
automatically cleared by hardware while entering the interrupt service routine.
HC3: Hardware Clear INT2 flag. Setting this bit allows the flag of external interrupt 3 to be
automatically cleared by hardware while entering the interrupt service routine.
T2CR: Timer 2 Capture Reset. In the Timer 2 Capture Mode this bit enables/disables hardware
automatically reset Timer 2 while the value in TL2 and TH2 have been transferred into the
capture register.
T2OE: Timer 2 Output Enable. This bit enables/disables the Timer 2 clock out function.
DCEN: Down Count Enable: This bit, in conjunction with the T2EX pin, controls the direction that
timer 2 counts in 16-bit auto-reload mode.
Timer 2 Capture LSB
Bit:
7
6
5
4
3
2
1
0
RCAP2L.7
RCAP2L.6 RCAP2L.5 RCAP2L.4 RCAP2L.3 RCAP2L.2 RCAP2L.1 RCAP2L.0
Mnemonic: RCAP2L
Address: CAh
RCAP2L: This register is used to capture the TL2 value when a timer 2 is configured in capture
mode. RCAP2L is also used as the LSB of a 16-bit reload value when timer 2 is
configured in auto-reload mode.
Timer 2 Capture MSB
Bit:
7
6
5
4
3
2
1
0
RCAP2H.7 RCAP2H.6 RCAP2H.5 RCAP2H.4 RCAP2H.3 RCAP2H.2 RCAP2H.1 RCAP2H.0
Mnemonic: RCAP2H
Address: CBh
Publication Release Date: August 16, 2002
Revision A1
- 29 -
Preliminary W77E516
RCAP2H: This register is used to capture the TH2 value when a timer 2 is configured in capture
mode. RCAP2H is also used as the MSB of a 16-bit reload value when timer 2 is
configured in auto-reload mode.
Timer 2 LSB
Bit:
7
6
5
4
3
2
1
0
TL2.7
TL2.6
TL2.5
TL2.4
TL2.3
TL2.2
TL2.1
TL2.0
Mnemonic: TL2
TL2: Timer 2 LSB
Address: CCh
Timer 2 MSB
Bit:
7
6
5
4
3
2
TH2.2
1
0
TH2.7
TH2.6
TH2.5
TH2.4
TH2.3
TH2.1
TH2.0
Mnemonic: TH2
TH2: Timer 2 MSB
Address: CDh
NVM Control
Bit:
7
6
5
4
3
2
1
-
0
ENVM
EWR
ETM3
ETM2
ETM1
ETM0
BUSY
Mnemonic: NVMCON
Address: CEh
ENVM: Enable 64 bytes NVM data cells while user would like to write or read NVM. If user would
not like to access NVM bytes. Clear ENVM bit to reduce power consumption.
EWR: Set this bit to write NVM bytes.
ETM3, ETM2, ETM1, ETM0: Adjust EEPROM timing for different MXT frequency. The default value
of ETMx bits are H.
MXT freq. (Hz)
0M - 2.5M
ETM3
ETM2
ETM1
EMT0
0
0
0
0
0
0
0
0
1
0
0S
0
0
0
1
1
0
0
1
1
0
0
1
0
1
0
1
0
1
0
2.6M - 5M
5.1M - 7.5M
7.6M - 10M
0
1
10.1M - 12.5M
12.6M - 15M
15.1M - 17.5M
17.6M - 20M
20.1M - 22.5M
1
1
1
0
- 30 -
Preliminary W77E516
Continued
MXT freq. (Hz)
22.6M - 25M
ETM3
ETM2
ETM1
EMT0
1
1
1
1
1
1
1
0
0
0
1
1
1
1
0
1
1
0
0
1
1
1
0
1
0
1
0
1
25.1M - 27.5M
27.6M - 30M
30.1M - 32.5M
32.6M - 35M
35.1M - 37.5M
37.6M - 40M
BUSY: CPU returns busy status. CPU will set this bit after write NVM bytes and clear it after
finished writing action. User can not read or write NVMDAT register while this bit is H
state. This bit is read only.
NVM Data Buffer
Bit:
7
6
5
4
3
2
1
0
D7
D6
D5
D4
D3
D2
D1
D0
Mnemonic: NVMDAT
Address: CFh
NVMDAT[7:0]: Each NVM byte is read/write content via this register. CPU will decode DCID5:0 bits
to address specific NVM byte. User must set EWR bit before write to these NVM
bytes. If user set lock bit of security register by external programmer, 64 bytes NVM
will be protected.
Program Status Word
Bit:
7
6
5
4
3
2
1
0
CY
AC
F0
RS1
RS0
OV
F1
P
Mnemonic: PSW
Address: D0h
CY: Carry flag: Set for an arithmetic operation which results in a carry being generated from the
ALU. It is also used as the accumulator for the bit operations.
AC: Auxiliary carry: Set when the previous operation resulted in a carry from the high order nibble.
F0: User flag 0: General purpose flag that can be set or cleared by the user.
RS.1 - 0: Register bank select bits:
RS1
RS0
Register bank
Address
00-07h
08-0Fh
10-17h
18-1Fh
0
0
1
1
0
1
0
1
0
1
2
3
Publication Release Date: August 16, 2002
Revision A1
- 31 -
Preliminary W77E516
OV: Overflow flag: Set when a carry was generated from the seventh bit but not from the 8th bit as
a result of the previous operation, or vice-versa.
F1: User Flag 1: General purpose flag that can be set or cleared by the user by software.
P: Parity flag: Set/cleared by hardware to indicate odd/even number of 1's in the accumulator.
Watchdog Control
Bit:
7
6
5
-
4
-
3
2
1
0
SMOD_1
POR
WDIF
WTRF
EWT
RWT
Mnemonic: WDCON
Address: D8h
SMOD_1: This bit doubles the Serial Port 1 baud rate in mode 1, 2, and 3 when set to 1.
POR: Power-on reset flag. Hardware will set this flag on a power up condition. This flag can be read
or written by software. A write by software is the only way to clear this bit once it is set.
WDIF: Watchdog Timer Interrupt Flag. If the watchdog interrupt is enabled, hardware will set this bit
to indicate that the watchdog interrupt has occurred. If the interrupt is not enabled, then this
bit indicates that the time-out period has elapsed. This bit must be cleared by software.
WTRF: Watchdog Timer Reset Flag. Hardware will set this bit when the watchdog timer causes a
reset. Software can read it but must clear it manually. A power-fail reset will also clear the
bit. This bit helps software in determining the cause of a reset. If EWT = 0, the watchdog
timer will have no affect on this bit.
EWT: Enable Watchdog timer Reset. Setting this bit will enable the Watchdog timer Reset function.
RWT: Reset Watchdog Timer. This bit helps in putting the watchdog timer into a know state. It also
helps in resetting the watchdog timer before a time-out occurs. Failing to set the EWT before
time-out will cause an interrupt, if EWDI (EIE.4) is set, and 512 clocks after that a watchdog
timer reset will be generated if EWT is set. This bit is self-clearing by hardware.
The WDCON SFR is set to a 0x0x0xx0b on an external reset. WTRF is set to a 1 on a Watchdog
timer reset, but to a 0 on power on/down resets. WTRF is not altered by an external reset. POR is set
to 1 by a power-on reset. EWT is set to 0 on a Power-on reset and unaffected by other resets.
All the bits in this SFR have unrestricted read access. POR, EWT, WDIF and RWT require Timed
Access procedure to write. The remaining bits have unrestricted write accesses. Please refer TA
register discription.
TA
REG C7H
REG D8H
REG 8EH
WDCON
CKCON
MOV
TA, #AAH
MOV
TA, #55H
SETB
ORL
WDCON.0
; Reset watchdog timer
CKCON, #11000000B ; Select 26 bits watchdog timer
MOV
TA, #AAH
TA, #55H
MOV
ORL
WDCON, #00000010B ; Enable watchdog
- 32 -
Preliminary W77E516
Accumulator
Bit:
7
6
5
4
3
2
1
0
ACC.7 ACC.6 ACC.5 ACC.4 ACC.3 ACC.2 ACC.1 ACC.0
Mnemonic: ACC
Address: E0h
ACC.7 - 0: The A (or ACC) register is the standard 8052 accumulator.
Extended Interrupt Enable
Bit:
7
-
6
-
5
-
4
3
2
EX4
1
0
EWDI
EX5
EX3
EX2
Mnemonic: EIE
Address: E8h
EIE.7 - 5: Reserved bits, will read high
EWDI: Enable Watchdog timer interrupt
EX5: External Interrupt 5 Enable.
EX4: External Interrupt 4 Enable.
EX3: External Interrupt 3 Enable.
EX2: External Interrupt 2 Enable.
B Register
Bit:
7
6
5
4
3
2
1
0
B.7
B.6
B.5
B.4
B.3
B.2
B.1
B.0
Mnemonic: B
Address: F0h
B.7 - 0: The B register is the standard 8052 register that serves as a second accumulator.
Extended Interrupt Priority
Bit:
7
-
6
-
5
-
4
3
2
1
0
PWDI
PX5
PX4
PX3
PX2
Mnemonic: EIP
Address: F8h
EIP.7 - 5: Reserved bits.
PWDI: Watchdog timer interrupt priority.
PX5: External Interrupt 5 Priority. 0 = Low priority, 1 = High priority.
PX4: External Interrupt 4 Priority. 0 = Low priority, 1 = High priority.
PX3: External Interrupt 3 Priority.
PX2: External Interrupt 2 Priority.
0 = Low priority, 1 = High priority.
0 = Low priority, 1 = High priority.
Publication Release Date: August 16, 2002
Revision A1
- 33 -
Preliminary W77E516
Instruction
The W77E516 executes all the instructions of the standard 8032 family. The operation of these
instructions, their effect on the flag bits and the status bits is exactly the same. However, timing of
these instructions is different. The reason for this is two fold. Firstly, in the W77E516, each machine
cycle consists of 4 clock periods, while in the standard 8032 it consists of 12 clock periods. Also, in the
W77E516 there is only one fetch per machine cycle i.e. 4 clocks per fetch, while in the standard 8032
there can be two fetches per machine cycle, which works out to 6 clocks per fetch.
The advantage the W77E516 has is that since there is only one fetch per machine cycle, the number
of machine cycles in most cases is equal to the number of operands that the instruction has. In case of
jumps and calls there will be an additional cycle that will be needed to calculate the new address. But
overall the W77E516 reduces the number of dummy fetches and wasted cycles, thereby improving
efficiency as compared to the standard 8032.
Table 2.
Instructions that affect Flag settings
Instruction
Carry
Overflow
Auxiliary Carry
Instruction
CLR C
Carry
Overflow
Auxiliary Carry
ADD
X
X
X
0
X
X
X
X
X
X
X
X
0
X
X
X
X
X
X
X
ADDC
SUBB
MUL
CPL C
ANL C, bit
ANL C, bit
ORL C, bit
ORL C, bit
MOV C, bit
CJNE
DIV
0
DA A
X
X
X
1
RRC A
RLC A
SETB C
A "X" indicates that the modification is as per the result of instruction.
Table 3. Instruction Timing for W77E516
W77E516
vs.
8032 Speed
Ratio
W77E516
Machine
Cycles
W77E516
Clock
Cycles
8032
Clock
Cycles
HEX
Op-Code
Instruction
Bytes
NOP
00
28
29
2A
2B
2C
2D
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
4
4
4
4
4
4
12
12
12
12
12
12
12
3
3
3
3
3
3
3
ADD A, R0
ADD A, R1
ADD A, R2
ADD A, R3
ADD A, R4
ADD A, R5
- 34 -
Preliminary W77E516
Table 3. Instruction Timing for W77E516, continued
W77E516
W77E516
Machine
Cycles
W77E516
Clock
Cycles
8032
Clock
Cycles
HEX
Op-Code
vs.
8032 Speed
Ratio
Instruction
Bytes
ADD A, R6
2E
2F
26
27
25
24
38
39
3A
3B
3C
3D
3E
3F
36
37
35
34
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
2
2
4
4
4
4
8
8
4
4
4
4
4
4
4
4
4
4
8
8
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
3
3
ADD A, R7
ADD A, @R0
ADD A, @R1
ADD A, direct
ADD A, #data
ADDC A, R0
ADDC A, R1
ADDC A, R2
ADDC A, R3
ADDC A, R4
ADDC A, R5
ADDC A, R6
ADDC A, R7
ADDC A, @R0
ADDC A, @R1
ADDC A, direct
ADDC A, #data
3
3
1.5
1.5
3
3
3
3
3
3
3
3
3
3
1.5
1.5
71, 91, B1, 11,
31, 51, D1, F1
ACALL addr11
AJMP ADDR11
2
2
3
3
12
12
24
24
2
2
01, 21, 41, 61,
81, A1, C1, E1
ANL A, R0
58
59
5A
5B
5C
5D
5E
5F
56
57
55
54
52
53
82
B0
B5
1
1
1
1
1
1
1
1
1
1
2
2
2
3
2
2
3
1
1
1
1
1
1
1
1
1
1
2
2
2
3
2
2
4
4
4
12
12
12
12
12
12
12
12
12
12
12
12
12
24
24
24
24
3
3
ANL A, R1
ANL A, R2
4
3
ANL A, R3
4
3
ANL A, R4
4
3
ANL A, R5
4
3
ANL A, R6
4
3
ANL A, R7
4
3
ANL A, @R0
ANL A, @R1
ANL A, direct
ANL A, #data
ANL direct, A
ANL direct, #data
ANL C, bit
4
3
4
3
8
1.5
1.5
1.5
2
8
8
12
8
3
ANL C, /bit
8
3
CJNE A, direct, rel
16
1.5
Publication Release Date: August 16, 2002
Revision A1
- 35 -
Preliminary W77E516
Table 3. Instruction Timing for W77E516, continued
W77E516
W77E516
Machine
Cycles
W77E516
Clock
Cycles
8032
Clock
Cycles
HEX
Op-Code
vs.
8032 Speed
Ratio
Instruction
Bytes
CJNE A, #data, rel
CJNE @R0, #data, rel
CJNE @R1, #data, rel
CJNE R0, #data, rel
CJNE R1, #data, rel
CJNE R2, #data, rel
CJNE R3, #data, rel
CJNE R4, #data, rel
CJNE R5, #data, rel
CJNE R6, #data, rel
CJNE R7, #data, rel
CLR A
B4
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
E4
F4
C3
C2
B3
B2
14
3
3
3
3
3
3
3
3
3
3
3
1
1
1
2
1
2
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
1
1
1
2
1
2
1
1
1
1
1
1
1
1
1
1
1
2
2
5
1
3
3
3
3
3
16
16
16
16
16
16
16
16
16
16
16
4
24
24
24
24
24
24
24
24
24
24
24
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
-
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
3
CPL A
4
3
CLR C
4
3
CLR bit
8
1.5
3
CPL C
4
CPL bit
8
1.5
3
DEC A
4
DEC R0
18
4
3
DEC R1
19
4
3
DEC R2
1A
1B
1C
1D
1E
1F
16
4
3
DEC R3
4
3
DEC R4
4
3
DEC R5
4
3
DEC R6
4
3
DEC R7
4
3
DEC @R0
4
3
DEC @R1
17
4
3
DEC direct
15
8
1.5
-
DEC DPTR
DIV AB
A5
84
8
20
4
48
12
24
24
24
24
24
2.4
3
DA A
D4
D8
D9
DD
DA
DB
DJNZ R0, rel
DJNZ R1, rel
DJNZ R5, rel
DJNZ R2, rel
DJNZ R3, rel
12
12
12
12
12
2
2
2
2
2
- 36 -
Preliminary W77E516
Table 3. Instruction Timing for W77E516, continued
W77E516
W77E516
Machine
Cycles
W77E516
Clock
Cycles
8032
Clock
Cycles
HEX
Op-Code
vs.
8032 Speed
Ratio
Instruction
Bytes
DJNZ R4, rel
DC
DE
DF
D5
04
08
09
0A
0B
0C
0D
0E
0F
06
07
05
A3
73
60
70
40
50
20
30
10
12
02
A4
E8
E9
EA
EB
EC
ED
EE
EF
E6
E7
2
2
2
3
1
1
1
1
1
1
1
1
1
1
1
2
1
1
2
2
2
2
3
3
3
3
3
1
1
1
1
1
1
1
1
1
1
1
3
3
3
4
1
1
1
1
1
1
1
1
1
1
1
2
2
2
3
3
3
3
4
4
4
4
4
5
1
1
1
1
1
1
1
1
1
1
12
12
12
16
4
24
24
24
24
12
12
12
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
24
24
48
12
12
12
12
12
12
12
12
12
12
2
2
DJNZ R6, rel
DJNZ R7, rel
DJNZ direct, rel
INC A
2
1.5
3
INC R0
4
3
INC R1
4
3
INC R2
4
3
INC R3
4
3
INC R4
4
3
INC R5
4
3
INC R6
4
3
INC R7
4
3
INC @R0
INC @R1
INC direct
INC DPTR
JMP @A+DPTR
JZ rel
4
3
4
3
8
1.5
3
8
8
3
12
12
12
12
16
16
16
16
16
20
4
2
JNZ rel
2
JC rel
2
JNC rel
2
JB bit, rel
JNB bit, rel
JBC bit, rel
LCALL addr16
LJMP addr16
MUL AB
1.5
1.5
1.5
1.5
1.5
2.4
3
MOV A, R0
MOV A, R1
MOV A, R2
MOV A, R3
MOV A, R4
MOV A, R5
MOV A, R6
MOV A, R7
MOV A, @R0
MOV A, @R1
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
Publication Release Date: August 16, 2002
Revision A1
- 37 -
Preliminary W77E516
Table 3. Instruction Timing for W77E516, continued
W77E516
W77E516
Machine
Cycles
W77E516
Clock
Cycles
8032
Clock
Cycles
HEX
Op-Code
vs.
8032 Speed
Ratio
Instruction
Bytes
MOV A, direct
E5
74
2
2
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
2
2
2
2
2
2
2
2
2
8
8
4
4
4
4
4
4
4
4
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
4
4
8
8
8
8
8
8
8
8
8
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
1.5
1.5
3
MOV A, #data
MOV R0, A
F8
F9
FA
FB
FC
FD
FE
FF
A8
A9
AA
AB
AC
AD
AE
AF
78
MOV R1, A
3
MOV R2, A
3
MOV R3, A
3
MOV R4, A
3
MOV R5, A
3
MOV R6, A
3
MOV R7, A
3
MOV R0, direct
MOV R1, direct
MOV R2, direct
MOV R3, direct
MOV R4, direct
MOV R5, direct
MOV R6, direct
MOV R7, direct
MOV R0, #data
MOV R1, #data
MOV R2, #data
MOV R3, #data
MOV R4, #data
MOV R5, #data
MOV R6, #data
MOV R7, #data
MOV @R0, A
MOV @R1, A
MOV @R0, direct
MOV @R1, direct
MOV @R0, #data
MOV @R1, #data
MOV direct, A
MOV direct, R0
MOV direct, R1
MOV direct, R2
MOV direct, R3
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
3
79
7A
7B
7C
7D
7E
7F
F6
F7
A6
A7
76
3
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
77
F5
88
89
8A
8B
- 38 -
Preliminary W77E516
Table 3. Instruction Timing for W77E516, continued
W77E516
W77E516
Machine
Cycles
W77E516
Clock
Cycles
8032
Clock
Cycles
HEX
Op-Code
vs.
8032 Speed
Ratio
Instruction
Bytes
MOV direct, R4
8C
8D
8E
8F
86
87
85
75
90
93
83
E2
E3
E0
F2
F3
F0
A2
92
48
49
4A
4B
4C
4D
4E
4F
46
47
45
44
42
43
72
A0
C0
D0
22
2
2
2
2
2
2
3
3
3
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
2
2
2
3
2
2
2
2
1
2
8
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
24
24
12
24
12
12
12
12
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
1.5
MOV direct, R5
MOV direct, R6
MOV direct, R7
MOV direct, @R0
MOV direct, @R1
MOV direct, direct
MOV direct, #data
MOV DPTR, #data 16
MOVC A, @A+DPTR
MOVC A, @A+PC
MOVX A, @R0
MOVX A, @R1
MOVX A, @DPTR
MOVX @R0, A
MOVX @R1, A
MOVX @DPTR, A
MOV C, bit
2
8
1.5
2
8
1.5
2
8
1.5
2
8
1.5
2
8
1.5
3
12
2
3
12
2
3
12
2
2
8
3
2
8
3
2 - 9
8 - 36
3 - 0.66
2 - 9
8 - 36
3 - 0.66
2 - 9
8 - 36
3 - 0.66
2 - 9
2 - 9
2 - 9
2
8 - 36
3 - 0.66
8 - 36
3 - 0.66
8 - 36
8
3 - 0.66
1.5
3
MOV bit, C
2
8
ORL A, R0
1
4
3
ORL A, R1
1
4
3
ORL A, R2
1
4
3
ORL A, R3
1
4
3
ORL A, R4
1
4
3
ORL A, R5
1
4
3
ORL A, R6
1
4
3
ORL A, R7
1
4
3
ORL A, @R0
ORL A, @R1
ORL A, direct
ORL A, #data
ORL direct, A
ORL direct, #data
ORL C, bit
1
4
3
1
4
3
2
8
1.5
1.5
1.5
2
2
8
2
8
3
12
8
2
3
ORL C, /bit
2
6
3
PUSH direct
2
8
3
POP direct
2
8
3
RET
2
8
3
Publication Release Date: August 16, 2002
Revision A1
- 39 -
Preliminary W77E516
Table 3. Instruction Timing for W77E516, continued
W77E516
W77E516
Machine
Cycles
W77E516
Clock
Cycles
8032
Clock
Cycles
HEX
Op-Code
vs.
8032 Speed
Ratio
Instruction
Bytes
RETI
RL A
32
23
1
1
1
1
1
1
2
1
2
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
2
1
1
1
1
1
2
1
3
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
8
4
4
4
4
4
8
4
12
4
4
4
4
4
4
4
4
4
4
8
8
4
4
4
4
4
4
4
4
4
4
4
4
8
4
4
4
24
12
12
12
12
12
12
12
24
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
3
3
RLC A
33
3
RR A
03
3
RRC A
13
3
SETB C
D3
D2
C4
80
3
SETB bit
1.5
3
SWAP A
SJMP rel
2
SUBB A, R0
SUBB A, R1
SUBB A, R2
SUBB A, R3
SUBB A, R4
SUBB A, R5
SUBB A, R6
SUBB A, R7
SUBB A, @R0
SUBB A, @R1
SUBB A, direct
SUBB A, #data
XCH A, R0
XCH A, R1
XCH A, R2
XCH A, R3
XCH A, R4
XCH A, R5
XCH A, R6
XCH A, R7
XCH A, @R0
XCH A, @R1
XCHD A, @R0
XCHD A, @R1
XCH A, direct
XRL A, R0
XRL A, R1
XRL A, R2
98
3
99
3
9A
9B
9C
9D
9E
9F
96
3
3
3
3
3
3
3
97
3
95
1.5
1.5
3
94
C8
C9
CA
CB
CC
CD
CE
CF
C6
C7
D6
D7
C5
68
3
3
3
3
3
3
3
3
3
3
3
1.5
3
69
3
6A
3
- 40 -
Preliminary W77E516
Table 3. Instruction Timing for W77E516, continued
W77E516
W77E516
Machine
Cycles
W77E516
Clock
Cycles
8032
Clock
Cycles
HEX
Op-Code
vs.
8032 Speed
Ratio
Instruction
Bytes
XRL A, R3
6B
6C
6D
6E
6F
66
67
65
64
62
63
1
1
1
1
1
1
1
2
2
2
3
1
1
1
1
1
1
1
2
2
2
3
4
4
12
12
12
12
12
12
12
12
12
12
24
3
3
XRL A, R4
XRL A, R5
4
3
XRL A, R6
4
3
XRL A, R7
4
3
XRL A, @R0
XRL A, @R1
XRL A, direct
XRL A, #data
XRL direct, A
XRL direct, #data
4
3
4
3
8
1.5
1.5
1.5
2
8
8
12
Instruction Timing
The instruction timing for the W77E516 is an important aspect, especially for those users who wish to
use software instructions to generate timing delays. Also, it provides the user with an insight into the
timing differences between the W77E516 and the standard 8032. In the W77E516 each machine cycle
is four clock periods long. Each clock period is designated a state. Thus each machine cycle is made
up of four states, C1, C2, C3 and C4 in that order. Due to the reduced time for each instruction
execution, both the clock edges are used for internal timing. Hence it is important that the duty cycle of
the clock be as close to 50% as possible to avoid timing conflicts. As mentioned earlier, the W77E516
does one op-code fetch per machine cycle. Therefore, in most of the instructions, the number of
machine cycles needed to execute the instruction is equal to the number of bytes in the instruction.
Of the 256 available op-codes, 128 of them are single cycle instructions. Thus more than half of all op-
codes in the W77E516 are executed in just four clock periods. Most of the two-cycle instructions are
those that have two byte instruction codes. However there are some instructions that have only one
byte instructions, yet they are two cycle instructions. One instruction which is of importance is the
MOVX instruction. In the standard 8032, the MOVX instruction is always two machine cycles long.
However in the W77E516, the user has a facility to stretch the duration of this instruction from 2
machine cycles to 9 machine cycles. The RD and WR strobe lines are also proportionately
elongated. This gives the user flexibility in accessing both fast and slow peripherals without the use of
external circuitry and with minimum software overhead. The rest of the instructions are either three,
four or five machine cycle instructions. Note that in the W77E516, based on the number of machine
cycles, there are five different types, while in the standard 8032 there are only three. However, in the
W77E516 each machine cycle is made of only 4 clock periods compared to the 12 clock periods for
the standard 8032. Therefore, even though the number of categories has increased, each instruction is
at least 1.5 to 3 times faster than the standard 8032 in terms of clock periods.
Publication Release Date: August 16, 2002
- 41 -
Revision A1
Preliminary W77E516
Single Cycle
C2
C4
C3
C1
CLK
ALE
PSEN
AD7-0
A7-0
Data_ in D7-0
Address A15-8
PORT 2
Figure 3. Single Cycle Instruction Timing
Operand Fetch
Instruction Fetch
C2 C3
C1
C4
C1
C2
C3
C4
CLK
ALE
PSEN
AD7-0
PC
OP-CODE
PC+1
OPERAND
Address A15-8
Address A15-8
PORT 2
Figure 4. Two Cycle Instruction Timing
Instruction Fetch
Operand Fetch
Operand Fetch
C1
C2
C3
C4
C1
C2
C3
C4
C1
C2
C3
C4
CLK
ALE
PSEN
AD7-0
A7-0
OP-CODE
A7-0
OPERAND
A7-0
OPERAND
Address A15-8
Address A15-8
Address A15-8
PORT 2
Figure 5. Three Cycle Instruction Timing
- 42 -
Preliminary W77E516
Instruction Fetch
Operand Fetch
Operand Fetch
Operand Fetch
C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4
CLK
ALE
PSEN
AD7-0
OP-CODE
A7-0
A7-0
A7-0
OPERAND
OPERAND
OPERAND
A7-0
Port 2
Address A15-8
Address A15-8
Address A15-8
Address A15-8
Figure 6. Four Cycle Instruction Timing
Operand Fetch
Instruction Fetch
Operand Fetch
Operand Fetch
Operand Fetch
C1
C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4
CLK
ALE
PSEN
OP-CODE
OPERAND
OPERAND
OPERAND
OPERAND
A7-0
AD7-0
A7-0
A7-0
A7-0
A7-0
Address A15-8
Address A15-8
Address A15-8
Address A15-8
Address A15-8
PORT 2
Figure 7. Five Cycle Instruction Timing
Publication Release Date: August 16, 2002
Revision A1
- 43 -
Preliminary W77E516
MOVX Instruction
The W77E516, like the standard 8032, uses the MOVX instruction to access external Data Memory.
This Data Memory includes both off-chip memory as well as memory mapped peripherals. While the
results of the MOVX instruction are the same as in the standard 8032, the operation and the timing of
the strobe signals have been modified in order to give the user much greater flexibility.
The MOVX instruction is of two types, the MOVX @Ri and MOVX @DPTR. In the MOVX @Ri, the
address of the external data comes from two sources. The lower 8-bits of the address are stored in the
Ri register of the selected working register bank. The upper 8-bits of the address come from the port 2
SFR. In the MOVX @DPTR type, the full 16-bit address is supplied by the Data Pointer.
Since the W77E516 has two Data Pointers, DPTR and DPTR1, the user has to select between the two
by setting or clearing the DPS bit. The Data Pointer Select bit (DPS) is the LSB of the DPS SFR, which
exists at location 86h. No other bits in this SFR have any effect, and they are set to 0. When DPS is 0,
then DPTR is selected, and when set to 1, DPTR1 is selected. The user can switch between DPTR
and DPTR1 by toggling the DPS bit. The quickest way to do this is by the INC instruction. The
advantage of having two Data Pointers is most obvious while performing block move operations. The
accompanying code shows how the use of two separate Data Pointers speeds up the execution time
for code performing the same task.
Block Move with single Data Pointer:
; SH and SL are the high and low bytes of Source Address
; DH and DL are the high and low bytes of Destination Address
; CNT is the number of bytes to be moved
Machine cycles of W77E516
#
MOV R2, #CNT
MOV R3, #SL
MOV R4, #SH
MOV R5, #DL
MOV R6, #DH
; Load R2 with the count value
2
2
2
2
2
; Save low byte of Source Address in R3
; Save high byte of Source address in R4
; Save low byte of Destination Address in R5
; Save high byte of Destination address in R6
LOOP:
MOV DPL, R3
MOV DPH, R4
MOVX A, @DPTR
; Load DPL with low byte of Source address
; Load DPH with high byte of Source address
; Get byte from Source to Accumulator
; Increment Source Address to next byte
; Save low byte of Source address in R3
; Save high byte of Source Address in R4
; Load low byte of Destination Address in DPL
; Load high byte of Destination Address in DPH
; Write data to destination
2
2
2
2
2
2
2
2
2
2
INC
DPTR
MOV R3, DPL
MOV R4, DPH
MOV DPL, R5
MOV DPH, R6
MOVX @DPTR, A
INC
DPTR
; Increment Destination Address
MOV DPL, R5
MOV DPH, R6
DJNZ R2, LOOP
; Save low byte of new destination address in R5 2
; Save high byte of new destination address in R6
; Decrement count and do LOOP again if count <> 0
2
2
- 44 -
Preliminary W77E516
Machine cycles in standard 8032 = 10 + (26 * CNT)
Machine cycles in W77E516 = 10 + (26 * CNT)
If CNT = 50
Clock cycles in standard 8032= ((10 + (26 *50)) * 12 = (10 + 1300) * 12 = 15720
Clock cycles in W77E516 = ((10 + (26 * 50)) * 4 = (10 + 1300) * 4 = 5240
Block Move with Two Data Pointers in W77E516:
; SH and SL are the high and low bytes of Source Address
; DH and DL are the high and low bytes of Destination Address
; CNT is the number of bytes to be moved
Machine cycles of W77E516
#
2
2
3
2
3
MOV R2, #CNT
MOV DPS, #00h
MOV DPTR, #DHDL ; Load DPTR with Destination address
INC DPS ; Set DPS to point to DPTR1
MOV DPTR, #SHSL ; Load DPTR1 with Source address
LOOP:
; Load R2 with the count value
; Clear DPS to point to DPTR
MOVX A, @DPTR
; Get data from Source block
; Increment source address
; Clear DPS to point to DPTR
; Write data to Destination
; Increment destination address
; Set DPS to point to DPTR1
; Check if all done
2
2
2
2
2
2
3
INC
DEC
DPTR
DPS
MOVX @DPTR, A
INC
INC
DPTR
DPS
DJNZ R2, LOOP
Machine cycles in W77E516 = 12 + (15 * CNT)
If CNT = 50
Clock cycles in W77E516 = (12 + (15 * 50)) * 4 = (12 + 750) * 4 = 3048
We can see that in the first program the standard 8032 takes 15720 cycles, while the W77E516 takes
only 5240 cycles for the same code. In the second program, written for the W77E516, program
execution requires only 3048 clock cycles. If the size of the block is increased then the saving is even
greater.
External Data Memory Access Timing
The timing for the MOVX instruction is another feature of the W77E516. In the standard 8032, the
MOVX instruction has a fixed execution time of 2 machine cycles. However in the W77E516, the
duration of the access can be varied by the user.
The instruction starts off as a normal op-code fetch of 4 clocks. In the next machine cycle, the
W77E516 puts out the address of the external Data Memory and the actual access occurs here. The
user can change the duration of this access time by setting the STRETCH value. The Clock Control
SFR (CKCON) has three bits that control the stretch value. These three bits are M2-0 (bits 2-0 of
CKCON). These three bits give the user 8 different access time options. The stretch can be varied
Publication Release Date: August 16, 2002
- 45 -
Revision A1
Preliminary W77E516
from 0 to 7, resulting in MOVX instructions that last from 2 to 9 machine cycles in length. Note that the
stretching of the instruction only results in the elongation of the MOVX instruction, as if the state of the
CPU was held for the desired period. There is no effect on any other instruction or its timing. By
default, the Stretch value is set at 1, giving a MOVX instruction of 3 machine cycles. If desired by the
user the stretch value can be set to 0 to give the fastest MOVX instruction of only 2 machine cycles.
Table 4. Data Memory Cycle Stretch Values
/RD or /WR
strobe width strobe width
in Clocks
/RD or /WR
/RD or /WR
strobe width
@40 MHz
Machine
Cycles
M2
M1
M0
@25 MHz
80 nS
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
2
2
50 nS
100 nS
200 nS
300 nS
400 nS
500 nS
600 nS
700 nS
3(default)
4
160 nS
320 nS
480 nS
640 nS
800 nS
960 nS
1120 nS
4
5
6
7
8
9
8
12
16
20
24
28
Second
Machine cycle
Next Instruction
Machine Cycle
Last Cycle
First
of Previous
Instruction
Machine cycle
MOVX instruction cycle
C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4
CLK
ALE
PSEN
WR
A0-A7
A0-A7
D0-D7
D0-D7
D0-D7
A0-A7
A0-A7
D0-D7
PORT 0
Next Inst.
Address
MOVX Data
Address
MOVX Inst.
Address
MOVX Inst.
MOVX Data out
A15-A8
Next Inst. Read
A15-A8
PORT 2
A15-A8
A15-A8
Figure 8: Data Memory Write with Stretch Value = 0
- 46 -
Preliminary W77E516
Last Cycle
First
Second
Third
Next Instruction
Machine Cycle
of Previous Machine Cycle Machine Cycle Machine Cycle
Instruction
MOVX instruction cycle
C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4
CLK
ALE
PSEN
WR
A0-A7
A0-A7
A0-A7
A0-A7
D0-D7
D0-D7
D0-D7
D0-D7
PORT 0
MOVX Inst.
Address
Next Inst.
Address
MOVX Data
Address
MOVX Data out
Next Inst.
Read
MOVX Inst.
A15-A8
A15-A8
A15-A8
A15-A8
PORT 2
Figure 9: Dada Memory Write with Stretch Value = 1
First
Second
Third
Fourth
Last Cycle
Next
Instruction
Machine Cycle
Machine Cycle
Machine Cycle
Machine Cycle
Machine Cycle
of Previous
Instruction
MOVX instruction cycle
C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4
CLK
ALE
PSEN
WR
A0-A7
A0-A7
A0-A7
A0-A7
D0-D7
D0-D7
D0-D7
D0-D7
PORT 0
MOVX Inst.
Address
Next Inst.
Address
MOVX Data
Address
MOVX Data out
Next Inst.
Read
MOVX Inst.
A15-A8
A15-A8
A15-A8
A15-A8
PORT 2
Figure 10: Dada Memory Write with Stretch Value = 2
Publication Release Date: August 16, 2002
Revision A1
- 47 -
Preliminary W77E516
Wait State Control Signal
Either with the software using stretch value to change the required machine cycle of MOVX instruction,
the W77E516 provides another hardware signal WAIT to implement the wider duration of external
data access timing. This wait state control signal is the alternate function of P4.0 such that it can only
be invoked to 44-pin PLCC/QFP package type. The wait state control signal can be enabled by setting
WS (ROMMAP.7) bit. When enabled, the setting of stretch value decides the minimum length of
MOVX instruction cycle and the device will sample the WAIT pin at each C3 state before the rising
edge of read/write strobe signal during MOVX instruction. Once this signal being recongnized, one
more machine cycle (wait state cycle) will be inserted into next cycle. The inserted wait state cycles are
unlimited, so the MOVX instruction cycle will end in which the wait state control signal is deactivated.
Using wait state control signal allows a dynamically access timimg to a selected external peripheral.
The WS bit is accessed by the Timed Access (TA register) Protection procedure.
Wait State Control Signal Timing (when Stretch = 1)
Third
Machine
Cycle
Second
Machine
Cycle
First
Machine
Cycle
Wait-State
Cycle
MOVX Instruction
C1 C2 C3 C4
C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4
C1 C2 C3 C4
CLOCK
ALE
PSEN
ADDRESS
RD / WR
WAIT
original rising edge
Extended duration
sample WAIT
sample
WAIT
Wait State Control Signal Timing (when Stretch = 2)
Third
Machine
Cycle
Second
Machine
Cycle
Fourth
Machine
Cycle
First
Machine
Cycle
Wait-State
Cycle
MOVX Instruction
C1 C2 C3 C4
C1 C2 C3 C4 C1 C2 C3 C4 C1 C2 C3 C4
C1 C2 C3 C4 C1 C2
CLOCK
ALE
PSEN
ADDRESS
RD / WR
WAIT
original rising edge
Extended duration
sample WAIT
sample
WAIT
- 48 -
Preliminary W77E516
Power Management
The W77E516 has several features that help the user to modify the power consumption of the device.
The power saving features are basically the POWER DOWN mode, ECONOMY mode and the IDLE
mode of operation.
Idle Mode
The user can put the device into idle mode by writing 1 to the bit PCON.0. The instruction that sets
the idle bit is the last instruction that will be executed before the device goes into Idle Mode. In the
Idle mode, the clock to the CPU is halted, but not to the Interrupt, Timer, Watchdog timer and Serial
port blocks. This forces the CPU state to be frozen; the Program counter, the Stack Pointer, the
Program Status Word, the Accumulator and the other registers hold their contents. The ALE and
PSEN pins are held high during the Idle state. The port pins hold the logical states they had at the
time Idle was activated. The Idle mode can be terminated in two ways. Since the interrupt controller
is still active, the activation of any enabled interrupt can wake up the processor. This will
automatically clear the Idle bit, terminate the Idle mode, and the Interrupt Service Routine (ISR) will
be executed. After the ISR, execution of the program will continue from the instruction which put the
device into Idle mode.
The Idle mode can also be exited by activating the reset. The device can be put into reset either by
applying a high on the external RST pin, a Power on/fail reset condition or a Watchdog timer reset.
The external reset pin has to be held high for at least two machine cycles I.e. 8 clock periods to be
recognized as a valid reset. In the reset condition the program counter is reset to 0000h and all the
SFRs are set to the reset condition. Since the clock is already running there is no delay and
execution starts immediately. In the Idle mode, the Watchdog timer continues to run, and if
enabled, a time-out will cause a watchdog timer interrupt which will wake up the device. The
software must reset the Watchdog timer in order to preempt the reset which will occur after 512
clock periods of the time-out. When the W77E516 is exiting from an Idle mode with a reset, the
instruction following the one which put the device into Idle mode is not executed. So there is no
danger of unexpected writes.
Economy Mode
The power consumption of microcontroller relates to operating frequency. The W77E516 offers a
Economy mode to reduce the internal clock rate dynamically without external components. By
default, one machine cycle needs 4 clocks. In Economy mode, software can select 4, 64 or 1024
clocks per machine cycle. It keeps the CPU operating at a acceptable speed but eliminates the
power consumption. In the Idle mode, the clock of the core logic is stopped, but all clocked
peripherals such as watchdog timer are still running at a rate of clock/4. In the Economy mode, all
clocked peripherals run at the same reduced clocks rate as in core logic. So the Economy mode
may provide a lower power consumption than idle mode.
Software invokes the Economy mode by setting the appropriate bits in the SFRs. Setting the bits
CD0(PMR.6),CD1(PMR.7) decides the instruction cycle rate as below:
CD1
CD0
Clocks/Machine Cycle
0
0
1
1
0
1
0
1
Reserved
4
(default)
64
1024
Publication Release Date: August 16, 2002
Revision A1
- 49 -
Preliminary W77E516
The selection of instruction rate is going to take effect after a delay of one instruction cycle.
Switching to divide by 64 or 1024 mode must first go from divide by 4 mode. This means software
can not switch directly between clock/64 and clock/1024 mode. The CPU has to return clock/4
mode first, then go to clock/64 or clock/1024 mode.
The W77E516 allows the user to use internal RC oscillator instead of external crystal. Setting the
XT/RG bit (EXIF.3) selects the crystal or RC oscillator as the clock source. When invoking RC
oscillator in Economy mode, software may set the XTOFF bit to turn off the crystal amplifier for
saving power. The CPU would run at the clock rate of approximately 2 - 4 MHz divided by 4, 64 or
1024. The RC oscillator is not precise so that can not be invoked to the operation which needs the
accurate time-base such as serial communication. The RGMD(EXIF.2) indicates current clock
source. When switching the clock source, CPU needs one instruction cycle delay to take effect new
setting. If crystal amplifier is disabled and RC oscillator is present clock source, software must first
clear the XTOFF bit to turn on crystal amplifier before switch to crystal operation. Hardware will set
the XTUP bit (STATUS.4) once the crystal is warm-up and ready for use. It is unable to set XT/RG
bit to 1 if XTUP = 0.
In Economy mode, the serial port can not receive/transmit data correctly because the baud rate is
changed. In some systems, the external interrupts may require the fastest process such that the
reducing of operating speed is restricted. In order to solve these dilemmas, the W77E516 offers a
switchback feature which allows the CPU back to clock/4 mode immediately when triggered by
serial operation or external interrupts. The switchback feature is enabled by setting the SWB bit
(PMR.5). A serial port reception/transmission or qualified external interrupt which is enabled and
acknowledged without block conditions will cause CPU to return to divide by 4 mode. For the serial
port reception, a switchback is generated by a falling edge associated with start bit if the serial port
reception is enabled. When a serial port transmission, an instruction which writes a byte of data to
serial port buffer will cause a switchback to ensure the correct transmission. The switchback feature
is unaffected by serial port interrupt flags. After a switchback is generated, the software can
manually return the CPU to Economy mode. Note that the modification of clock control bits CD0
and CD1 will be ignored during serial port transmit/receive when switchback is enabled. The
Watchdog timer reset, power-on/fail reset or external reset will force the CPU to return to divide by
4 mode.
Power Down Mode
The device can be put into Power Down mode by writing 1 to bit PCON.1. The instruction that does
this will be the last instruction to be executed before the device goes into Power Down mode. In the
Power Down mode, all the clocks are stopped and the device comes to a halt. All activity is
completely stopped and the power consumption is reduced to the lowest possible value. In this
state the ALE and PSEN pins are pulled low. The port pins output the values held by their
respective SFRs.
The W77E516 will exit the Power Down mode with a reset or by an external interrupt pin enabled as
level detect.
An external reset can be used to exit the Power down state. The high on RST pin
terminates the Power Down mode, and restarts the clock. The program execution will restart from
0000h. In the Power down mode, the clock is stopped, so the Watchdog timer cannot be used to
provide the reset to exit Power down mode.
The W77E516 can be woken from the Power Down mode by forcing an external interrupt pin
activated, provided the corresponding interrupt is enabled, while the global enable(EA) bit is set and
the external input has been set to a level detect mode. If these conditions are met, then the low
- 50 -
Preliminary W77E516
level on the external pin re-starts the oscillator. Then device executes the interrupt service routine
for the corresponding external interrupt. After the interrupt service routine is completed, the
program execution returns to the instruction after the one which put the device into Power Down
mode and continues from there. When RGSL(EXIF.1) bit is set to 1, the CPU will use the internal
RC oscillator instead of crystal to exit Power Down mode. The microcontroller will automatically
switch from RC oscillator to crystal after clock is stable. The RC oscillator runs at approximately 2 -
4 MHz. Using RC oscillator to exit from Power Down mode saves the time for waiting crystal start-
up. It is useful in the low power system which usually be awakened from a short operation then
returns to Power Down mode.
Table 5. Status of external pins during Idle and Power Down
PROGRAM
MEMORY
MODE
ALE
PORT0
PORT1
PORT2
PORT3
PSEN
Idle
Idle
Internal
1
1
0
0
1
1
0
0
Data
Float
Data
Float
Data
Data
Data
Data
Data
Address
Data
Data
Data
Data
Data
External
Internal
Power Down
Power Down
External
Data
Reset Conditions
The user has several hardware related options for placing the W77E516 into reset condition. In
general, most register bits go to their reset value irrespective of the reset condition, but there are a few
flags whose state depends on the source of reset. The user can use these flags to determine the
cause of reset using software. There are three ways of putting the device into reset state. They are
External reset, Power on reset and Watchdog reset.
External Reset
The device continuously samples the RST pin at state C4 of every machine cycle. Therefore the
RST pin must be held for at least 2 machine cycles to ensure detection of a valid RST high. The
reset circuitry then synchronously applies the internal reset signal. Thus the reset is a synchronous
operation and requires the clock to be running to cause an external reset.
Once the device is in reset condition, it will remain so as long as RST is 1. Even after RST is
deactivated, the device will continue to be in reset state for up to two machine cycles, and then
begin program execution from 0000h. There is no flag associated with the external reset condition.
However since the other two reset sources have flags, the external reset can be considered as the
default reset if those two flags are cleared.
Watchdog Timer Reset
The Watchdog timer is a free running timer with programmable time-out intervals. The user can
clear the watchdog timer at any time, causing it to restart the count. When the time-out interval is
reached an interrupt flag is set. If the Watchdog reset is enabled and the watchdog timer is not
cleared, then 512 clocks from the flag being set, the watchdog timer will generate a reset. This
places the device into the reset condition. The reset condition is maintained by hardware for two
machine cycles. Once the reset is removed the device will begin execution from 0000h.
Publication Release Date: August 16, 2002
- 51 -
Revision A1
Preliminary W77E516
Reset State
Most of the SFRs and registers on the device will go to the same condition in the reset state. The
Program Counter is forced to 0000h and is held there as long as the reset condition is applied.
However, the reset state does not affect the on-chip RAM. The data in the RAM will be preserved
during the reset. However, the stack pointer is reset to 07h, and therefore the stack contents will be
lost. The RAM contents will be lost if the VDD falls below approximately 2V, as this is the minimum
voltage level required for the RAM to operate normally. Therefore after a first time power on reset the
RAM contents will be indeterminate. During a power fail condition, if the power falls below 2V, the RAM
contents are lost. Hence it should be assumed that after a power on/fail reset, POR = 1, the RAM
contents are lost.
After a reset most SFRs are cleared. Interrupts and Timers are disabled. The Watchdog timer is
disabled if the reset source was a POR. The port SFRs have FFh written into them which puts the port
pins in a high state. Port 0 floats as it does not have on-chip pull-ups.
Table 6. SFR Reset Value
SFR NAME
P0
RESET VALUE
11111111b
00000111b
00000000b
00000000b
00000000b
00000000b
00000000b
00xx0000b
00000000b
00000000b
00000000b
00000000b
00000000b
00000000b
00000001b
11111111b
00000000b
xxxxxxxxb
11111111b
00000000b
00000000b
SFR NAME
IE
RESET VALUE
00000000b
00000000b
11111111b
x0000000b
00000000b
00000000b
00000x00b
00000000b
00000000b
00000000b
00000000b
11111111b
00000000b
0x0x0xx0b
00000000b
xxx00000b
00000000b
xxx00000b
00000000b
00000000b
xxxxxxxxb
010xx0x0b
000x0000b
SP
SADDR
P3
DPL
DPH
IP
DPL1
DPH1
DPS
SADEN
T2CON
T2MOD
RCAP2L
RCAP2H
TL2
PCON
TCON
TMOD
TL0
TH2
TL1
TA
TH0
PSW
TH1
WDCON
ACC
CKCON
P1
EIE
SCON
SBUF
P2
B
EIP
PC
SADDR1
SCON1
ROMMAP
EXIF
SADEN1
SBUF1
PMR
01xxxxxxb
0000xxx0b
xxxx1111b
STATUS
P4
- 52 -
Preliminary W77E516
The WDCON SFR bits are set/cleared in reset condition depending on the source of the reset.
External reset
0x0x0xx0b
Watchdog reset
0x0x01x0b
Power on reset
01000000b
WDCON
The POR bit WDCON.6 is set only by the power on reset. The WTRF bit WDCON.2 is set when the
Watchdog timer causes a reset. A power on reset will also clear this bit. The EWT bit WDCON.1 is
cleared by power on resets. This disables the Watchdog timer resets. A watchdog or external reset
does not affect the EWT bit.
Interrupts
The W77E516 has a two priority level interrupt structure with 12 interrupt sources. Each of the interrupt
sources has an individual priority bit, flag, interrupt vector and enable bit. In addition, the interrupts can
be globally enabled or disabled.
Interrupt Sources
The External Interrupts INT0 and INT1 can be either edge triggered or level triggered,
depending on bits IT0 and IT1. The bits IE0 and IE1 in the TCON register are the flags which are
checked to generate the interrupt. In the edge triggered mode, the INTx inputs are sampled in every
machine cycle. If the sample is high in one cycle and low in the next, then a high to low transition is
detected and the interrupts request flag IEx in TCON or EXIF is set. The flag bit requests the
interrupt. Since the external interrupts are sampled every machine cycle, they have to be held high
or low for at least one complete machine cycle. The IEx flag is automatically cleared when the
service routine is called. If the level triggered mode is selected, then the requesting source has to
hold the pin low till the interrupt is serviced. The IEx flag will not be cleared by the hardware on
entering the service routine. If the interrupt continues to be held low even after the service routine is
completed, then the processor may acknowledge another interrupt request from the same source.
Note that the external interrupts INT2 to INT5 are edge triggered only. By default, the individual
interrupt flag corresponding to external interrupt 2 to 5 must be cleared manually by software. It can
be configured with hardware cleared by setting the corresponding bit HCx in the T2MOD register.
For instance, if HC2 is set hardware will clear IE2 flag after program enters the interrupt 2 service
routine.
The Timer 0 and 1 Interrupts are generated by the TF0 and TF1 flags. These flags are set by the
overflow in the Timer 0 and Timer 1. The TF0 and TF1 flags are automatically cleared by the
hardware when the timer interrupt is serviced. The Timer 2 interrupt is generated by a logical OR of
the TF2 and the EXF2 flags. These flags are set by overflow or capture/reload events in the timer 2
operation. The hardware does not clear these flags when a timer 2 interrupt is executed. Software
has to resolve the cause of the interrupt between TF2 and EXF2 and clear the appropriate flag.
The Watchdog timer can be used as a system monitor or a simple timer. In either case, when the
time-out count is reached, the Watchdog timer interrupt flag WDIF (WDCON.3) is set. If the
interrupt is enabled by the enable bit EIE.4, then an interrupt will occur.
The Serial block can generate interrupts on reception or transmission. There are two interrupt
sources from the Serial block, which are obtained by the RI and TI bits in the SCON SFR and RI_1
and TI_1 in the SCON1 SFR. These bits are not automatically cleared by the hardware, and the
user will have to clear these bits using software.
Publication Release Date: August 16, 2002
- 53 -
Revision A1
Preliminary W77E516
All the bits that generate interrupts can be set or reset by hardware, and thereby software initiated
interrupts can be generated. Each of the individual interrupts can be enabled or disabled by setting
or clearing a bit in the IE SFR. IE also has a global enable/disable bit EA, which can be cleared to
disable all the interrupts, except PFI, at once.
Priority Level Structure
There are two priority levels for the interrupts, high and low. The interrupt source can be individually
set to either high or low levels. Naturally, a higher priority interrupt cannot be interrupted by a lower
priority interrupt. However there exists a pre-defined hierarchy amongst the interrupts themselves.
This hierarchy comes into play when the interrupt controller has to resolve simultaneous requests
having the same priority level. This hierarchy is defined as shown below; the interrupts are
numbered starting from the highest priority to the lowest.
Table 7. Priority structure of interrupts
SOURCE
External Interrupt 0
Timer 0 Overflow
External Interrupt 1
Timer 1 Overflow
Serial Port
FLAG
PRIORITY LEVEL
IE0
1 (highest)
TF0
IE1
2
3
TF1
RI + TI
4
5
Timer 2 Overflow
Serial Port 1
TF2 + EXF2
RI_1 + TI_1
IE2
6
7
External Interrupt 2
External Interrupt 3
External Interrupt 4
External Interrupt 5
Watchdog Timer
8
IE3
9
IE4
10
IE5
11
WDIF
12 (lowest)
The interrupt flags are sampled every machine cycle. In the same machine cycle, the sampled
interrupts are polled and their priority is resolved. If certain conditions are met then the hardware will
execute an internally generated LCALL instruction which will vector the process to the appropriate
interrupt vector address. The conditions for generating the LCALL are
1. An interrupt of equal or higher priority is not currently being serviced.
2. The current polling cycle is the last machine cycle of the instruction currently being executed.
3. The current instruction does not involve a write to IP, IE, EIP or EIE registers and is not a RETI.
If any of these conditions are not met, then the LCALL will not be generated. The polling cycle is
repeated every machine cycle, with the interrupts sampled in the same machine cycle. If an
interrupt flag is active in one cycle but not responded to, and is not active when the above
conditions are met, the denied interrupt will not be serviced. This means that active interrupts are
not remembered; every polling cycle is new.
- 54 -
Preliminary W77E516
The processor responds to a valid interrupt by executing an LCALL instruction to the appropriate
service routine. This may or may not clear the flag which caused the interrupt. In case of Timer
interrupts, the TF0 or TF1 flags are cleared by hardware whenever the processor vectors to the
appropriate timer service routine. In case of external interrupt, INT0 and INT1, the flags are cleared
only if they are edge triggered. In case of Serial interrupts, the flags are not cleared by hardware.
In the case of Timer 2 interrupt, the flags are not cleared by hardware. The Power-Fail interrupt PFI
flag and Watchdog timer interrupt flag WDIF have to be cleared by software. The hardware LCALL
behaves exactly like the software LCALL instruction. This instruction saves the Program Counter
contents onto the Stack, but does not save the Program Status Word PSW. The PC is reloaded
with the vector address of that interrupt which caused the LCALL. These vector address for the
different sources are as follows.
Table 8. Vector locations for interrupt sources
SOURCE
VECTOR ADDRESS
000Bh
SOURCE
External Interrupt 0
External Interrupt 1
Serial Port
VECTOR ADDRESS
0003h
Timer 0 Overflow
Timer 1 Overflow
Timer 2 Interrupt
External Interrupt 2
External Interrupt 4
Watchdog Timer
001Bh
0013h
002Bh
0023h
0043h
Serial Port 1
003Bh
0053h
External Interrupt 3
External Interrupt 5
004Bh
0063h
005Bh
The vector table is not evenly spaced; this is to accommodate future expansions to the device
family.
Execution continues from the vectored address till an RETI instruction is executed. On execution of
the RETI instruction the processor pops the Stack and loads the PC with the contents at the top of
the stack. The user must take care that the status of the stack is restored to what is was after the
hardware LCALL, if the execution is to return to the interrupted program. The processor does not
notice anything if the stack contents are modified and will proceed with execution from the address
put back into PC. Note that a RET instruction would perform exactly the same process as a RETI
instruction, but it would not inform the Interrupt Controller that the interrupt service routine is
completed, and would leave the controller still thinking that the service routine is underway.
Interrupt Response Time
The response time for each interrupt source depends on several factors, such as the nature of the
interrupt and the instruction underway. In the case of external interrupts INT0 to INT5 , they
are sampled at C3 of every machine cycle and then their corresponding interrupt flags IEx will be
set or reset. The Timer 0 and 1 overflow flags are set at C3 of the machine cycle in which overflow
has occurred. These flag values are polled only in the next machine cycle. If a request is active and
all three conditions are met, then the hardware generated LCALL is executed. This LCALL itself
takes four machine cycles to be completed. Thus there is a minimum time of five machine cycles
between the interrupt flag being set and the interrupt service routine being executed.
A longer response time should be anticipated if any of the three conditions are not met. If a higher
or equal priority is being serviced, then the interrupt latency time obviously depends on the nature of
the service routine currently being executed. If the polling cycle is not the last machine cycle of the
Publication Release Date: August 16, 2002
- 55 -
Revision A1
Preliminary W77E516
instruction being executed, then an additional delay is introduced. The maximum response time (if
no other interrupt is in service) occurs if the W77E516 is performing a write to IE, IP, EIE or EIP and
then executes a MUL or DIV instruction. From the time an interrupt source is activated, the longest
reaction time is 12 machine cycles. This includes 1 machine cycle to detect the interrupt, 2 machine
cycles to complete the IE, IP, EIE or EIP access, 5 machine cycles to complete the MUL or DIV
instruction and 4 machine cycles to complete the hardware LCALL to the interrupt vector location.
Thus in a single-interrupt system the interrupt response time will always be more than 5 machine
cycles and not more than 12 machine cycles. The maximum latency of 12 machine cycle is 48 clock
cycles. Note that in the standard 8051 the maximum latency is 8 machine cycles which equals 96
machine cycles. This is a 50% reduction in terms of clock periods.
8. PROGRAMMABLE TIMERS/COUNTERS
The W77E516 has three 16-bit programmable timer/counters and one programmable Watchdog timer.
The Watchdog timer is operationally quite different from the other two timers.
Timer/Counters 0 & 1
The W77E516 has two 16-bit Timer/Counters. Each of these Timer/Counters has two 8 bit registers
which form the 16 bit counting register. For Timer/Counter 0 they are TH0, the upper 8 bits register,
and TL0, the lower 8 bit register. Similarly Timer/Counter 1 has two 8 bit registers, TH1 and TL1. The
two can be configured to operate either as timers, counting machine cycles or as counters counting
external inputs.
When configured as a "Timer", the timer counts clock cycles. The timer clock can be programmed to
be thought of as 1/12 of the system clock or 1/4 of the system clock. In the "Counter" mode, the
register is incremented on the falling edge of the external input pin, T0 in case of Timer 0, and T1 for
Timer 1. The T0 and T1 inputs are sampled in every machine cycle at C4. If the sampled value is high
in one machine cycle and low in the next, then a valid high to low transition on the pin is recognized
and the count register is incremented. Since it takes two machine cycles to recognize a negative
transition on the pin, the maximum rate at which counting will take place is 1/24 of the master clock
frequency. In either the "Timer" or "Counter" mode, the count register will be updated at C3. Therefore,
in the "Timer" mode, the recognized negative transition on pin T0 and T1 can cause the count register
value to be updated only in the machine cycle following the one in which the negative edge was
detected.
The "Timer" or "Counter" function is selected by the "C/ T " bit in the TMOD Special Function Register.
Each Timer/Counter has one selection bit for its own; bit 2 of TMOD selects the function for
Timer/Counter 0 and bit 6 of TMOD selects the function for Timer/Counter 1. In addition each
Timer/Counter can be set to operate in any one of four possible modes. The mode selection is done by
bits M0 and M1 in the TMOD SFR.
- 56 -
Preliminary W77E516
Time-base Selection
The W77E516 gives the user two modes of operation for the timer. The timers can be programmed to
operate like the standard 8051 family, counting at the rate of 1/12 of the clock speed. This will ensure
that timing loops on the W77E516 and the standard 8051 can be matched. This is the default mode of
operation of the W77E516 timers. The user also has the option to count in the turbo mode, where the
timers will increment at the rate of 1/4 clock speed. This will straight-away increase the counting speed
three times. This selection is done by the T0M and T1M bits in CKCON SFR. A reset sets these bits to
0, and the timers then operate in the standard 8051 mode. The user should set these bits to 1 if the
timers are to operate in turbo mode.
Mode 0
In Mode 0, the timer/counters act as a 8 bit counter with a 5 bit, divide by 32 pre-scale. In this mode
we have a 13 bit timer/counter. The 13 bit counter consists of 8 bits of THx and 5 lower bits of TLx.
The upper 3 bits of TLx are ignored.
The negative edge of the clock increments the count in the TLx register. When the fifth bit in TLx
moves from 1 to 0, then the count in the THx register is incremented. When the count in THx
moves from FFh to 00h, then the overflow flag TFx in TCON SFR is set. The counted input is
enabled only if TRx is set and either GATE = 0 or INTx = 1. When C/ T is set to 0, then it will
count clock cycles, and if C/ T is set to 1, then it will count 1 to 0 transitions on T0 (P3.4) for timer
0 and T1 (P3.5) for timer 1. When the 13 bit count reaches 1FFFh the next count will cause it to
roll-over to 0000h. The timer overflow flag TFx of the relevant timer is set and if enabled an
interrupts will occur. Note that when used as a timer, the time-base may be either clock cycles/12 or
clock cycles/4 as selected by the bits TxM of the CKCON SFR.
T0M = CKCON.3
(T1M = CKCON.4)
Timer 1 functions are shown in brackets
Clock Source
M1,M0 = TMOD.1,TMOD.0
(M1,M0 = TMOD.5,TMOD.4)
C/T = TMOD.2
Mode
div. by 4
input
osc/1
1/4
1
(C/T = TMOD.6)
div. by 64
osc/16
00
0
1
div. by 1024 osc/256
0
1/12
0
4
7
0
7
T0 = P3.4
(T1 = P3.5)
01
TL0
TH0
(TL1)
(TH1)
TR0 = TCON.4
(TR1 = TCON.6)
GATE = TMOD.3
TFx
Interrupt
(GATE = TMOD.7)
INT0 = P3.2
TF0
(INT1 = P3.3)
(TF1)
Figure 11: Timer/Counter
Mode 0 & Mode 1
Publication Release Date: August 16, 2002
Revision A1
- 57 -
Preliminary W77E516
Mode 1
Mode 1 is similar to Mode 0 except that the counting register forms a 16 bit counter, rather than a
13 bit counter. This means that all the bits of THx and TLx are used. Roll-over occurs when the
timer moves from a count of FFFFh to 0000h. The timer overflow flag TFx of the relevant timer is
set and if enabled an interrupt will occur. The selection of the time-base in the timer mode is similar
to that in Mode 0. The gate function operates similarly to that in Mode 0.
Mode 2
In Mode 2, the timer/counter is in the Auto Reload Mode. In this mode, TLx acts as a 8 bit count
register, while THx holds the reload value. When the TLx register overflows from FFh to 00h, the
TFx bit in TCON is set and TLx is reloaded with the contents of THx, and the counting process
continues from here. The reload operation leaves the contents of the THx register unchanged.
Counting is enabled by the TRx bit and proper setting of GATE and INTx pins. As in the other
two modes 0 and 1, mode 2 allows counting of either clock cycles (clock/12 or clock/4) or pulses on
pin Tn.
T0M = CKCON.3
(T1M = CKCON.4)
Clock Source
Timer 1 functions are shown in brackets
Mode
input
1/4
C/T = TMOD.2
1
0
div. by 4
osc/1
TL0
(TL1)
(C/T = TMOD.6)
0
div. by 64
osc/16
div. by 1024 osc/256
1/12
TFx
Interrupt
0
0
7
1
T0 = P3.4
(T1 = P3.5)
TF0
(TF1)
TR0 = TCON.4
(TR1 = TCON.6)
GATE = TMOD.3
(GATE = TMOD.7)
7
TH0
(TH1)
INT0 = P3.2
(INT1 = P3.3)
Figure 12: Timer/Counter
Mode 2
Mode 3
Mode 3 has different operating methods for the two timer/counters. For timer/counter 1, mode 3
simply freezes the counter. Timer/Counter 0, however, configures TL0 and TH0 as two separate 8
bit count registers in this mode. The logic for this mode is shown in the figure. TL0 uses the
Timer/Counter 0 control bits C/ T , GATE, TR0, INT0 and TF0. The TL0 can be used to count
clock cycles (clock/12 or clock/4) or 1-to-0 transitions on pin T0 as determined by C/ T (TMOD.2).
TH0 is forced as a clock cycle counter (clock/12 or clock/4) and takes over the use of TR1 and TF1
from Timer/Counter 1. Mode 3 is used in cases where an extra 8 bit timer is needed. With Timer 0
in Mode 3, Timer 1 can still be used in Modes 0, 1 and 2., but its flexibility is somewhat limited.
- 58 -
Preliminary W77E516
While its basic functionality is maintained, it no longer has control over its overflow flag TF1 and the
enable bit TR1. Timer 1 can still be used as a timer/counter and retains the use of GATE and INT1
pin. In this condition it can be turned on and off by switching it out of and into its own Mode 3. It can
also be used as a baud rate generator for the serial port.
T0M = CKCON.3
Clock Source
1/4
1
Mode
div. by 4
div. by 64
input
osc/1
C/T = TMOD.2
0
TL0
osc/16
0
1/12
div. by 1024 osc/256
Interrupt
0
7
TF0
1
T0 = P3.4
TR0 = TCON.4
GATE = TMOD.3
INT0 = P3.2
TH0
Interrupt
0
7
TF1
TR1 = TCON.6
Figure 13. Timer/Counter 0 Mode 3
Timer/Counter 2
Timer/Counter 2 is a 16 bit up/down counter which is configured by the T2MOD register and controlled
by the T2CON register. Timer/Counter 2 is equipped with a capture/reload capability. As with the Timer
0 and Timer 1 counters, there exists considerable flexibility in selecting and controlling the clock, and in
defining the operating mode. The clock source for Timer/Counter 2 may be selected for either the
external T2 pin (C/ T2 = 1) or the crystal oscillator, which is divided by 12 or 4 (C/ T2 = 0). The clock
is then enabled when TR2 is a 1, and disabled when TR2 is a 0. The modes available on Timer 2 are
described below.
RCLK+TCLK
CP/RL2
T2OE
MODE
Auto-reload Mode
Capture Mode
0
0
1
X
0
1
X
0
0
X
0
1
Baud Rate Generator
Programmable Clock Out
Capture Mode
The capture mode is enabled by setting the CP/RL2 bit in the T2CON register to a 1. In the
capture mode, Timer/Counter 2 serves as a 16 bit up counter. When the counter rolls over from
FFFFh to 0000h, the TF2 bit is set, which will generate an interrupt request. If the EXEN2 bit is set,
then a negative transition of T2EX pin will cause the value in the TL2 and TH2 register to be
captured by the RCAP2L and RCAP2H registers. This action also causes the EXF2 bit in T2CON to
Publication Release Date: August 16, 2002
- 59 -
Revision A1
Preliminary W77E516
be set, which will also generate an interrupt. Setting the T2CR bit (T2MOD.3), the W77E516 allows
hardware to reset timer 2 automatically after the value of TL2 and TH2 have been captured.
T2M = CKCON.5
1
Clock Source
1/4
Mode
input
C/T2 = T2CON.1
div. by 4
osc/1
T2CON.7
TF2
0
div. by 64
osc/16
1/12
0
div. by 1024 osc/256
TL2
TH2
1
T2 = P1.0
TR2 = T2CON.2
Timer 2
Interrupt
T2EX = P1.1
RCAP2L RCAP2H
L
H
EXEN2 = T2CON.3
EXF2
T2CON.6
Figure 14. 16-Bit Capture Mode
Auto-reload Mode, Counting Up
The auto-reload mode as an up counter is enabled by clearing the CP/RL2 bit in the T2CON
register and clearing the DCEN bit in T2MOD register. In this mode, Timer/Counter 2 is a 16 bit up
counter. When the counter rolls over from FFFFh, a reload is generated that causes the contents of
the RCAP2L and RCAP2H registers to be reloaded into the TL2 and TH2 registers. The reload
action also sets the TF2 bit. If the EXEN2 bit is set, then a negative transition of T2EX pin will also
cause a reload. This action also sets the EXF2 bit in T2CON.
T2M = CKCON.5
Clock Source
1/4
1
Mode
input
osc/1
C/T2 = T2CON.1
div. by 4
0
T2CON.7
div. by 64
div. by 1024 osc/256
osc/16
1/12
0
TL2
TH2
TF2
1
T2 = P1.0
TR2 = T2CON.2
Timer 2
Interrup
T2EX = P1.1
RCAP2L RCAP2H
L
EXEN2 = T2CON.3
EXF2
T2CON.6
Figure 15. 16-Bit Auto-reload Mode, Counting Up
- 60 -
Preliminary W77E516
Auto-reload Mode, Counting Up/Down
Timer/Counter 2 will be in auto-reload mode as an up/down counter if CP/RL2 bit in T2CON is
cleared and the DCEN bit in T2MOD is set. In this mode, Timer/Counter 2 is an up/down counter
whose direction is controlled by the T2EX pin. A 1 on this pin cause the counter to count up. An
overflow while counting up will cause the counter to be reloaded with the contents of the capture
registers. The next down count following the case where the contents of Timer/Counter equal the
capture registers will load an FFFFh into Timer/Counter 2. In either event a reload will set the TF2
bit. A reload will also toggle the EXF2 bit. However, the EXF2 bit can not generate an interrupt while
in this mode.
Down Counting Reload Value
0FFh
0FFh
T2M = CKCON.5
Clock Source
C/T = T2CON.1
1/4
Mode
input
1
0
div. by 4
osc/1
0
T2CON.7
TF2
div. by 64 osc/16
div. by 1024 osc/256
1/12
Timer 2
Interrupt
TL2
TH2
1
T2 = P1.0
TR2 = T2CON.2
RCAP2L RCAP2H
Up Counting Reload Value
T2EX = P1.1
EXF2
T2CON.6
DCEN = 1
Figure 16. 16-Bit Auto-reload Up/Down Counter
Baud Rate Generator Mode
The baud rate generator mode is enabled by setting either the RCLK or TCLK bits in T2CON
register. While in the baud rate generator mode, Timer/Counter 2 is a 16 bit counter with auto
reload when the count rolls over from FFFFh. However, rolling over does not set the TF2 bit. If
EXEN2 bit is set, then a negative transition of the T2EX pin will set EXF2 bit in the T2CON register
and cause an interrupt request.
Clock Source
Mode
div. by 4
div. by 64
input
C/T = T2CON.1
0
osc/2
osc/32
Timer 2
overflow
div. by 1024 osc/512
TL2
TH2
1
T2 = P1.0
TR2 = T2CON.2
T2EX = P1.1
RCAP2L RCAP2H
Timer 2
Interrupt
EXF2
T2CON.6
EXEN2 = T2CON.3
Figure 17. Baud Rate Generator Mode
Publication Release Date: August 16, 2002
Revision A1
- 61 -
Preliminary W77E516
Programmable Clock-out
Timer 2 is equipped with a new clock-out feature which outputs a 50% duty cycle clock on P1.0. It
can be invoked as a programmable clock generator. To configure Timer 2 with clock-out mode,
software must initiate it by setting bit T2OE = 1, C/T2 = 0 and CP/RL = 0. Setting bit TR2 will start
the timer. This mode is similar to the baud rate generator mode, it will not generate an interrupt
while Timer 2 overflow. So it is possible to use Timer 2 as a baud rate generator and a clock
generator at the same time. The clock-out frequency is determined by the following equation:
The Clock-out Frequency = Oscillator Frequency / [4 X (65536-RCAP2H, RCAP2L)]
Clock Source
Mode
div. by 4
div. by 64
input
osc/2
1/2
osc/32
TL2
TH2
T2=P1.0
div. by 1024 osc/512
TR2 = T2CON.2
T2EX = P1.1
RCAP2L RCAP2H
Timer 2
Interrupt
EXF2
T2CON.6
EXEN2 = T2CON.3
Figure 18. Programmable Clock-Out Mode
Watchdog Timer
The Watchdog timer is a free-running timer which can be programmed by the user to serve as a
system monitor, a time-base generator or an event timer. It is basically a set of dividers that divide the
system clock. The divider output is selectable and determines the time-out interval. When the time-out
occurs a flag is set, which can cause an interrupt if enabled, and a system reset can also be caused if
it is enabled. The interrupt will occur if the individual interrupt enable and the global enable are set. The
interrupt and reset functions are independent of each other and may be used separately or together
depending on the users software.
0
16
19
22
25
WD1,WD0
Time-out
Interrupt
Clock Source
WDIF
Mode
div. by 4
input
osc/1
EWDI(EIE.4)
00
01
10
11
div. by 64
osc/16
17
20
23
div. by 1024 osc/256
WTRF
512 clock
delay
Reset
Reset Watchdog
RWT (WDCON.0)
Enable Watchdog timer reset
EWT(WDCON.1)
Figure 19. Watchdog Timer
- 62 -
Preliminary W77E516
The Watchdog timer should first be restarted by using RWT. This ensures that the timer starts from a
known state. The RWT bit is used to restart the watchdog timer. This bit is self clearing, i.e. after
writing a 1 to this bit the software will automatically clear it. The watchdog timer will now count clock
cycles. The time-out interval is selected by the two bits WD1 and WD0 (CKCON.7 and CKCON.6).
When the selected time-out occurs, the Watchdog interrupt flag WDIF (WDCON.3) is set. After the
time-out has occurred, the watchdog timer waits for an additional 512 clock cycles. If the Watchdog
Reset EWT (WDCON.1) is enabled, then 512 clocks after the time-out, if there is no RWT, a system
reset due to Watchdog timer will occur. This will last for two machine cycles, and the Watchdog timer
reset flag WTRF (WDCON.2) will be set. This indicates to the software that the watchdog was the
cause of the reset.
When used as a simple timer, the reset and interrupt functions are disabled. The timer will set the
WDIF flag each time the timer completes the selected time interval. The WDIF flag is polled to detect a
time-out and the RWT allows software to restart the timer. The Watchdog timer can also be used as a
very long timer. The interrupt feature is enabled in this case. Every time the time-out occurs an
interrupt will occur if the global interrupt enable EA is set.
The main use of the Watchdog timer is as a system monitor. This is important in real-time control
applications. In case of some power glitches or electro-magnetic interference, the processor may begin
to execute errant code. If this is left unchecked the entire system may crash. Using the watchdog timer
interrupt during software development will allow the user to select ideal watchdog reset locations. The
code is first written without the watchdog interrupt or reset. Then the watchdog interrupt is enabled to
identify code locations where interrupt occurs. The user can now insert instructions to reset the
watchdog timer which will allow the code to run without any watchdog timer interrupts. Now the
watchdog timer reset is enabled and the watchdog interrupt may be disabled. If any errant code is
executed now, then the reset watchdog timer instructions will not be executed at the required instants
and watchdog reset will occur.
The watchdog time-out selection will result in different time-out values depending on the clock speed.
The reset, when enabled, will occur 512 clocks after the time-out has occurred. WDIF, EWT and RWT
bits are protected by TA register.
Table 9. Time-out values for the Watchdog timer
WATCHDOGIN
TERVAL
NUMBER OF
CLOCKS
TIME
@1.8432 MHz
TIME
@10 MHz
TIME
@25 MHz
WD1
WD0
0
0
1
1
0
1
0
1
217
220
223
226
131072
1048576
8388608
67108864
71.11 mS
568.89 mS
13.11 mS
104.86 mS
838.86 mS
6710.89 mS
5.24 mS
41.94 mS
335.54 mS
2684.35 mS
4551.11 mS
36408.88 mS
The Watchdog timer will de disabled by a power-on/fail reset. The Watchdog timer reset does not
disable the watchdog timer, but will restart it. In general, software should restart the timer to put it into a
known state.
The control bits that support the Watchdog timer are discussed below.
Watch Dog Control
WDIF: WDCON.3 - Watchdog Timer Interrupt flag. This bit is set whenever the time-out occurs in
the watchdog timer. If the Watchdog interrupt is enabled (EIE.4), then an interrupt will occur
Publication Release Date: August 16, 2002
- 63 -
Revision A1
Preliminary W77E516
(if the global interrupt enable is set and other interrupt requirements are met). Software or
any reset can clear this bit.
WTRF: WDCON.2 - Watchdog Timer Reset flag. This bit is set whenever a watchdog reset occurs.
This bit is useful for determined the cause of a reset. Software must read it, and clear it
manually. A Power-fail reset will clear this bit. If EWT = 0, then this bit will not be affected by
the watchdog timer.
EWT: WDCON.1 - Enable Watchdog timer Reset. This bit when set to 1 will enable the Watchdog
timer reset function. Setting this bit to 0 will disable the Watchdog timer reset function, but
will leave the timer running
RWT: WDCON.0 - Reset Watchdog Timer. This bit is used to clear the Watchdog timer and to
restart it. This bit is self-clearing, so after the software writes 1 to it the hardware will
automatically clear it. If the Watchdog timer reset is enabled, then the RWT has to be set by
the user within 512 clocks of the time-out. If this is not done then a Watchdog timer reset will
occur.
Clock Control
WD1, WD0: CKCON.7, CKCON.6 - Watchdog Timer Mode select bits. These two bits select the
time-out interval for the watchdog timer. The reset time is 512 clock longer than the interrupt time-
out value.
17
The default Watchdog time-out is 2 clocks, which is the shortest time-out period. The EWT,
WDIF and RWT bits are protected by the Timed Access procedure. This prevents software from
accidentally enabling or disabling the watchdog timer. More importantly, it makes it highly
improbable that errant code can enable or disable the watchdog timer.
Serial Port
Serial port in the W77E516 is a full duplex port. The W77E516 provides the user with additional
features such as the Frame Error Detection and the Automatic Address Recognition. The serial ports
are capable of synchronous as well as asynchronous communication. In Synchronous mode the
W77E516 generates the clock and operates in a half duplex mode. In the asynchronous mode, full
duplex operation is available. This means that it can simultaneously transmit and receive data. The
transmit register and the receive buffer are both addressed as SBUF Special Function Register.
However any write to SBUF will be to the transmit register, while a read from SBUF will be from the
receive buffer register. The serial port can operate in four different modes as described below.
Mode 0
This mode provides synchronous communication with external devices. In this mode serial data is
transmitted and received on the RXD line. TXD is used to transmit the shift clock. The TxD clock is
provided by the W77E516 whether the device is transmitting or receiving. This mode is therefore a
half duplex mode of serial communication. In this mode, 8 bits are transmitted or received per
frame. The LSB is transmitted/received first. The baud rate is fixed at 1/12 or 1/4 of the oscillator
frequency. This baud rate is determined by the SM2 bit (SCON.5). When this bit is set to 0, then the
serial port runs at 1/12 of the clock. When set to 1, the serial port runs at 1/4 of the clock. This
additional facility of programmable baud rate in mode 0 is the only difference between the standard
8051 and the W77E516.
- 64 -
Preliminary W77E516
The functional block diagram is shown below. Data enters and leaves the Serial port on the RxD
line. The TxD line is used to output the shift clock. The shift clock is used to shift data into and out
of the W77E516 and the device at the other end of the line. Any instruction that causes a write to
SBUF will start the transmission. The shift clock will be activated and data will be shifted out on the
RxD pin till all 8 bits are transmitted. If SM2 = 1, then the data on RxD will appear 1 clock period
before the falling edge of shift clock on TxD. The clock on TxD then remains low for 2 clock
periods, and then goes high again. If SM2 = 0, the data on RxD will appear 3 clock periods before
the falling edge of shift clock on TxD. The clock on TxD then remains low for 6 clock periods, and
then goes high again. This ensures that at the receiving end the data on RxD line can either be
clocked on the rising edge of the shift clock on TxD or latched when the TxD clock is low.
Clock Source
Mode
div. by 4
div. by 64
input
osc/1
osc/16
div. by 1024 osc/256
Internal
Data Bus
RXD
P3.0 Alternate
Output Function
PARIN
SOUT
Write to
SBUF
LOAD
CLOCK
¸ 12
¸ 4
TX SHIFT
TI
TX START
Transmit Shift Register
Serial Port Interrupt
TX CLOCK
SM2
SERIAL
RI
0
1
CONTROLLER
SHIFT
CLOCK
TXD
P3.1 Alternate
Output function
RX
CLOCK
LOAD SBUF
RX SHIFT
RI
RX
START
REN
Read SBUF
SBUF
CLOCK
SIN
RXD
PAROUT
SBUF
Internal
P3.0 Alternate
Iutput function
Data Bus
Receive Shift Register
Figure 20. Serial Port Mode 0
The TI flag is set high in C1 following the end of transmission of the last bit. The serial port will
receive data when REN is 1 and RI is zero. The shift clock (TxD) will be activated and the serial port
will latch data on the rising edge of shift clock. The external device should therefore present data on
the falling edge on the shift clock. This process continues till all the 8 bits have been received.
The RI flag is set in C1 following the last rising edge of the shift clock on TxD. This will stop
reception, till the RI is cleared by software.
Mode 1
In Mode 1, the full duplex asynchronous mode is used. Serial communication frames are made up
of 10 bits transmitted on TXD and received on RXD. The 10 bits consist of a start bit (0), 8 data bits
(LSB first), and a stop bit (1). On receive, the stop bit goes into RB8 in the SFR SCON. The baud
rate in this mode is variable. The serial baud can be programmed to be 1/16 or 1/32 of the Timer 1
overflow. Since the Timer 1 can be set to different reload values, a wide variation in baud rates is
possible.
Transmission begins with a write to SBUF. The serial data is brought out on to TxD pin at C1
following the first roll-over of divide by 16 counter. The next bit is placed on TxD pin at C1 following
the next rollover of the divide by 16 counter. Thus the transmission is synchronized to the divide by
16 counter and not directly to the write to SBUF signal. After all 8 bits of data are transmitted, the
Publication Release Date: August 16, 2002
- 65 -
Revision A1
Preliminary W77E516
stop bit is transmitted. The TI flag is set in the C1 state after the stop bit has been put out on TxD
pin. This will be at the 10th rollover of the divide by 16 counter after a write to SBUF.
Reception is enabled only if REN is high. The serial port actually starts the receiving of serial data,
with the detection of a falling edge on the RxD pin. The 1-to-0 detector continuously monitors the
RxD line, sampling it at the rate of 16 times the selected baud rate. When a falling edge is detected,
the divide by 16 counter is immediately reset. This helps to align the bit boundaries with the
rollovers of the divide by 16 counter.
The 16 states of the counter effectively divide the bit time into 16 slices. The bit detection is done on
a best of three basis. The bit detector samples the RxD pin, at the 8th, 9th and 10th counter states.
By using a majority 2 of 3 voting system, the bit value is selected. This is done to improve the noise
rejection feature of the serial port. If the first bit detected after the falling edge of RxD pin is not 0,
then this indicates an invalid start bit, and the reception is immediately aborted. The serial port
again looks for a falling edge in the RxD line. If a valid start bit is detected, then the rest of the bits
are also detected and shifted into the SBUF.
After shifting in 8 data bits, there is one more shift to do, after which the SBUF and RB8 are loaded
and RI is set. However certain conditions must be met before the loading and setting of RI can be
done.
1. RI must be 0 and
2. Either SM2 = 0, or the received stop bit = 1.
If these conditions are met, then the stop bit goes to RB8, the 8 data bits go into SBUF and RI is
set. Otherwise the received frame may be lost. After the middle of the stop bit, the receiver goes
back to looking for a 1-to-0 transition on the RxD pin.
Timer 1
Overflow
Transmit Shift Register
Timer 2 Overflow
(for Serial Port 0 only)
STOP
Internal
Data Bus
PARIN
Write to
SBUF
SOUT
¸ 2
TXD
START
LOAD
SMOD=
(SMOD_1)
CLOCK
0
1
TX START TX SHIFT
TX CLOCK
TCLK
0
0
1
1
¸ 16
TI
Serial Port
Interrupt
RCLK
SERIAL
RI
CONTROLLER
¸ 16
RX CLOCK
LOAD
SAMPLE
RX
Read
SBUF
1-TO-0
DETECTOR
SBUF
RX SHIFT
START
CLOCK
Internal
Data
Bus
SBUF
RB8
PAROUT
BIT
DETECTOR
D8
SIN
RXD
Receive Shift Register
Figure 21: Serial Port
Mode 1
- 66 -
Preliminary W77E516
Mode 2
This mode uses a total of 11 bits in asynchronous full-duplex communication. The functional
description is shown in the figure below. The frame consists of one start bit (0), 8 data bits (LSB
first), a programmable 9th bit (TB8) and a stop bit (1). The 9th bit received is put into RB8. The
baud rate is programmable to 1/32 or 1/64 of the oscillator frequency, which is determined by the
SMOD bit in PCON SFR. Transmission begins with a write to SBUF. The serial data is brought out
on to TxD pin at C1 following the first roll-over of the divide by 16 counter. The next bit is placed on
TxD pin at C1 following the next rollover of the divide by 16 counter. Thus the transmission is
synchronized to the divide by 16 counter, and not directly to the write to SBUF signal. After all 9 bits
of data are transmitted, the stop bit is transmitted. The TI flag is set in the C1 state after the stop bit
has been put out on TxD pin. This will be at the 11th rollover of the divide by 16 counter after a write
to SBUF. Reception is enabled only if REN is high. The serial port actually starts the receiving of
serial data, with the detection of a falling edge on the RxD pin. The 1-to-0 detector continuously
monitors the RxD line, sampling it at the rate of 16 times the selected baud rate. When a falling
edge is detected, the divide by 16 counter is immediately reset. This helps to align the bit
boundaries with the rollovers of the divide by 16 counter. The 16 states of the counter effectively
divide the bit time into 16 slices. The bit detection is done on a best of three basis. The bit detector
samples the RxD pin, at the 8th, 9th and 10th counter states. By using a majority 2 of 3 voting
system, the bit value is selected. This is done to improve the noise rejection feature of the serial
port. If the first bit detected after the falling edge of RxD pin, is not 0, then this indicates an invalid
start bit, and the reception is immediately aborted. The serial port again looks for a falling edge in
the RxD line. If a valid start bit is detected, then the rest of the bits are also detected and shifted into
the SBUF. After shifting in 9 data bits, there is one more shift to do, after which the SBUF and RB8
are loaded and RI is set. However certain conditions must be met before the loading and setting of
RI can be done.
1. RI must be 0 and
2. Either SM2 = 0, or the received stop bit = 1.
If these conditions are met, then the D8 bit goes to RB8, the 8 data bits go into SBUF and RI is set.
Otherwise the received frame may be lost. After the middle of the stop bit, the receiver goes back to
looking for a 1-to-0 transition on the RxD pin.
Publication Release Date: August 16, 2002
- 67 -
Revision A1
Preliminary W77E516
Clock Source
Mode
div. by 4
input
osc/2
div. by 64
div. by 1024 osc/512
osc/32
TB8
D8
STOP
Internal
Data Bus
PARIN
Write to
SBUF
¸ 2
TXD
SOUT
START
LOAD
T
SMOD=
(SMOD_1)
CLOCK
0
1
TX
SHIFT
TX START
TX CLOCK
Transmit Shift Register
¸ 16
TI
SERIAL
Serial Port
Interrupt
CONTROLLER
RI
¸ 16
RX CLOCK
LOAD
SBUF
RX SHIFT
SAMPLE
Read
SBUF
RX START
1-TO-0
DETECTOR
Internal
CLOCK
PAROUT
SBUF
RB8
Data
Bus
BIT
DETECTOR
SIN
D8
RXD
Receive Shift Register
Figure 22. Serial Port
Mode 2
- 68 -
Preliminary W77E516
Mode 3
This mode is similar to Mode 2 in all respects, except that the baud rate is programmable. The user
must first initialize the Serial related SFR SCON before any communication can take place. This
involves selection of the Mode and baud rate. The Timer 1 should also be initialized if modes 1 and
3 are used. In all four modes, transmission is started by any instruction that uses SBUF as a
destination register. Reception is initiated in Mode 0 by the condition RI = 0 and REN = 1. This will
generate a clock on the TxD pin and shift in 8 bits on the RxD pin. Reception is initiated in the other
modes by the incoming start bit if REN = 1. The external device will start the communication by
transmitting the start bit.
Table 10.
SM1
Serial Ports Modes
FRAME START STOP
9TH BIT
FUNCTION
SM0
MODE
TYPE
BAUD CLOCK
SIZE
BIT
No
1
BIT
No
1
0
0
1
1
0
1
0
1
0
1
2
3
Synch.
Asynch.
Asynch.
Asynch.
4 or 12 TCLKs
Timer 1 or 2
32 or 64 TCLKs
Timer 1 or 2
8 bits
None
None
0, 1
10 bits
11 bits
11 bits
1
1
1
1
0, 1
Timer 1
Overflow
Timer 2 Overflow
(for Serial Port 0 only)
STOP
TB8
D8
Internal
Data Bus
PARIN
Write to
SBUF
SOUT
¸ 2
TXD
START
LOAD
SMOD=
(SMOD_1)
CLOCK
0
1
Transmit Shift Register
TX START TX SHIFT
TX CLOCK
TCLK
0
0
1
1
¸ 16
TI
Serial Port
Interrupt
RCLK
SERIAL
RI
CONTROLLER
¸ 16
RX CLOCK
LOAD
SBUF
SAMPLE
RX
Read
SBUF
1-TO-0
DETECTOR
START
RX SHIFT
CLOCK
SIN
Internal
Data
Bus
SBUF
PAROUT
BIT
DETECTOR
D8
RB8
RXD
Receive Shift Register
Figure 23: Serial Port Mode 3
Publication Release Date: August 16, 2002
Revision A1
- 69 -
Preliminary W77E516
Framing Error Detection
A Frame Error occurs when a valid stop bit is not detected. This could indicate incorrect serial data
communication. Typically the frame error is due to noise and contention on the serial communication
line. The W77E516 has the facility to detect such framing errors and set a flag which can be checked
by software.
The Frame Error FE(FE_1) bit is located in SCON.7(SCON1.7). This bit is normally used as SM0 in the
standard 8051 family. However, in the W77E516 it serves a dual function and is called SM0/FE
(SM0_1/FE_1). There are actually two separate flags, one for SM0 and the other for FE. The flag that
is actually accessed as SCON.7(SCON1.7) is determined by SMOD0 (PCON.6) bit. When SMOD0 is
set to 1, then the FE flag is indicated in SM0/FE. When SMOD0 is set to 0, then the SM0 flag is
indicated in SM0/FE.
The FE bit is set to 1 by hardware but must be cleared by software. Note that SMOD0 must be 1 while
reading or writing to FE or FE_1. If FE is set, then any following frames received without any error will
not clear the FE flag. The clearing has to be done by software.
Multiprocessor Communications
Multiprocessor communications makes use of the 9th data bit in modes 2 and 3. In the W77E516, the
RI flag is set only if the received byte corresponds to the Given or Broadcast address. This hardware
feature eliminates the software overhead required in checking every received address, and greatly
simplifies the software programmer task.
In the multiprocessor communication mode, the address bytes are distinguished from the data bytes by
transmitting the address with the 9th bit set high. When the master processor wants to transmit a block
of data to one of the slaves, it first sends out the address of the targeted slave (or slaves). All the slave
processors should have their SM2 bit set high when waiting for an address byte. This ensures that they
will be interrupted only by the reception of a address byte. The Automatic address recognition feature
ensures that only the addressed slave will be interrupted. The address comparison is done in hardware
not software.
The addressed slave clears the SM2 bit, thereby clearing the way to receive data bytes. With SM2 = 0,
the slave will be interrupted on the reception of every single complete frame of data. The unaddressed
slaves will be unaffected, as they will be still waiting for their address. In Mode 1, the 9th bit is the stop
bit, which is 1 in case of a valid frame. If SM2 is 1, then RI is set only if a valid frame is received and
the received byte matches the Given or Broadcast address.
The Master processor can selectively communicate with groups of slaves by using the Given Address.
All the slaves can be addressed together using the Broadcast Address. The addresses for each slave
are defined by the SADDR and SADEN SFRs. The slave address is an 8-bit value specified in the
SADDR SFR. The SADEN SFR is actually a mask for the byte value in SADDR. If a bit position in
SADEN is 0, then the corresponding bit position in SADDR is don't care. Only those bit positions in
SADDR whose corresponding bits in SADEN are 1 are used to obtain the Given Address. This gives
the user flexibility to address multiple slaves without changing the slave address in SADDR.
The following example shows how the user can define the Given Address to address different slaves.
Slave 1:
SADDR1010 0100
SADEN 1111 1010
Given 1010 0x0x
- 70 -
Preliminary W77E516
Slave 2:
SADDR1010 0111
SADEN 1111 1001
Given 1010 0xx1
The Given address for slave 1 and 2 differ in the LSB. For slave 1, it is a don't care, while for slave 2 it
is 1. Thus to communicate only with slave 1, the master must send an address with LSB = 0 (1010
0000). Similarly the bit 1 position is 0 for slave 1 and don't care for slave 2. Hence to communicate only
with slave 2 the master has to transmit an address with bit 1 = 1 (1010 0011). If the master wishes to
communicate with both slaves simultaneously, then the address must have bit 0 = 1 and bit 1 = 0. The
bit 3 position is don't care for both the slaves. This allows two different addresses to select both slaves
(1010 0001 and 1010 0101).
The master can communicate with all the slaves simultaneously with the Broadcast Address. This
address is formed from the logical ORing of the SADDR and SADEN SFRs. The zeros in the result are
defined as don't cares in most cases the Broadcast Address is FFh. In the previous case, the
Broadcast Address is (1111111X) for slave 1 and (11111111) for slave 2.
The SADDR and SADEN SFRs are located at address A9h and B9h respectively. On reset, these two
SFRs are initialized to 00h. This results in Given Address and Broadcast Address being set as XXXX
XXXX(i.e. all bits don't care). This effectively removes the multiprocessor communications feature,
since any selectivity is disabled.
9. TIMED ACCESS PROTECTION
The W77E516 has several new features, like the Watchdog timer, on-chip ROM size adjustment, wait
state control signal and Power on/fail reset flag, which are crucial to proper operation of the system. If
left unprotected, errant code may write to the Watchdog control bits resulting in incorrect operation and
loss of control. In order to prevent this, the W77E516 has a protection scheme which controls the write
access to critical bits. This protection scheme is done using a timed access.
In this method, the bits which are to be protected have a timed write enable window. A write is
successful only if this window is active, otherwise the write will be discarded. This write enable window
is open for 3 machine cycles if certain conditions are met. After 3 machine cycles, this window
automatically closes. The window is opened by writing AAh and immediately 55h to the Timed
Access(TA) SFR. This SFR is located at address C7h. The suggested code for opening the timed
access window is
TA
REG 0C7h
;define new register TA, located at 0C7h
MOV TA, #0AAh
MOV TA, #055h
When the software writes AAh to the TA SFR, a counter is started. This counter waits for 3 machine
cycles looking for a write of 55h to TA. If the second write (55h) occurs within 3 machine cycles of the
first write (AAh), then the timed access window is opened. It remains open for 3 machine cycles, during
which the user may write to the protected bits. Once the window closes the procedure must be
repeated to access the other protected bits.
Examples of Timed Assessing are shown below.
Example 1: Valid access
MOV TA, #0AAh
3 M/C
Note: M/C = Machine Cycles
Publication Release Date: August 16, 2002
Revision A1
- 71 -
Preliminary W77E516
MOV TA, #055h
MOV WDCON, #00h 3 M/C
Example 2: Valid access
MOV TA, #0AAh
3 M/C
3 M/C
3 M/C
1 M/C
2 M/C
MOV TA, #055h
NOP
SETB EWT
Example 3: Invalid access
MOV TA, #0AAh
MOV TA, #055h
NOP
3 M/C
3 M/C
1 M/C
1 M/C
2 M/C
NOP
CLR
POR
Example 4: Invalid Access
MOV TA, #0AAh
NOP
3 M/C
1 M/C
3 M/C
2 M/C
MOV TA, #055h
SETB EWT
In the first two examples, the writing to the protected bits is done before the 3 machines cycle window
closes. In Example 3, however, the writing to the protected bit occurs after the window has closed, and
so there is effectively no change in the status of the protected bit. In Example 4, the second write to TA
occurs 4 machine cycles after the first write, therefore the timed access window in not opened at all,
and the write to the protected bit fails.
10. ABSOLUTE MAXIMUM RATINGS
PARAMETER
DC Power Supply
SYMBOL
VDD - VSS
VIN
CONDITION
RATING
+7.0
UNIT
V
-0.3
VSS -0.3
0
Input Voltage
VDD +0.3
+70
V
Operating Temperature
Storage Temperatute
TA
°C
°C
Tst
-55
+150
Note: Exposure to conditions beyond those listed under Absolute Maximum Ratings may adversely affect the life and reliability
of the device.
- 72 -
Preliminary W77E516
11. DC CHARACTERISTICS
(VDD- VSS = 5V ±10%, TA = 25°C, Fosc = 20 MHz, unless otherwise specified.)
SPECIFICATION
PARAMETER
Operating Voltage
SYM.
TEST CONDITIONS
MIN.
4.5
MAX.
UNIT
VDD
IDD
5.5
V
No load
VDD = RST = 5.5V
Idle mode
VDD = 5.5V
Power-down mode
VDD = 5.5V
VDD = 5.5V
VIN = 0V or VDD
VDD = 5.5V
Operating Current
Idle Current
-
-
50
24
mA
mA
mA
mA
mA
mA
mA
V
IIDLE
IPWDN
IIN1
Power Down Current
-
50
Input Current
P1, P2, P3
-50
-10
-10
-500
0
+10
+300
+10
-200
0.8
Input Current
IIN2
RST[*1]
0 < VIN < VDD
Input Leakage Current
VDD = 5.5V
0V < VIN < VDD
ILK
ITL[*4]
VIL1
P0, EA
Logic 1 to 0 Transition Current
P1, P2, P3
VDD = 5.5V
VIN = 2.0V
Input Low Voltage
VDD = 4.5V
P0, P1, P2, P3, EA
Input Low Voltage
RST[*1]
VIL2
VIL3
0
0
0.8
V
V
V
V
V
V
VDD = 4.5V
VDD = 4.5V
VDD = 5.5V
VDD = 5.5V
VDD = 5.5V
Input Low Voltage
0.8
XTAL1[*3]
Input High Voltage
VIH1
VIH2
VIH3
VOL1
2.4
3.5
3.5
-
VDD +0.2
VDD +0.2
VDD +0.2
0.45
P0, P1, P2, P3, EA
Input High Voltage
RST
Input High Voltage
XTAL1[*3]
Output Low Voltage
P1, P2, P3
VDD = 4.5V
IOL = +4 mA
Output Low Voltage
VDD = 4.5V
IOL = +10 mA
VOL2
VOH1
VOH2
-
0.45
V
V
V
P0, ALE, PSEN [*2]
Output High Voltage
P1, P2, P3
VDD = 4.5V
IOH = -120 mA
2.4
2.4
-
-
Output High Voltage
P0, ALE, PSEN [*2]
VDD = 4.5V
IOH = -8 mA
Notes:
*1. RST pin is a Schmitt trigger input.
*2. P0, ALE and PSEN are tested in the external access mode.
*3. XTAL1 is a CMOS input.
*4. Pins of P1, P2, P3, P4 can source a transition current when they are being externally driven from 1 to 0. The transition
current reaches its maximum value when VIN approximates to 2V.
Publication Release Date: August 16, 2002
- 73 -
Revision A1
Preliminary W77E516
11. AC CHARACTERISTICS
tCLCL
tCLCH
tCLCX
tCHCL
tCHCX
External Clock Characteristics
PARAMETER
Clock High Time
Clock Low Time
Clock Rise Time
Clock Fall Time
SYMBOL
tCHCX
MIN.
TYP.
MAX.
UNITS
nS
NOTES
12.5
-
-
-
-
-
tCLCX
12.5
-
nS
tCLCH
-
-
10
10
nS
tCHCL
nS
Note: Duty cycle is 50 %.
AC Specification
VARIABLE
CLOCK
MIN.
VARIABLE
CLOCK
MAX.
PARAMETER
SYM.
UNITS
Oscillator Frequency
1/tCLCL
tLHLL
0
40
MHz
nS
nS
nS
nS
nS
nS
nS
ALE Pulse Width
1.5 tCLCL - 5
0.5 tCLCL - 5
0.5 tCLCL - 5
0.5 tCLCL - 5
Address Valid to ALE Low
Address Hold After ALE Low
tAVLL
tLLAX1
tLLAX2
tLLIV
Address Hold After ALE Low for MOVX Write
ALE Low to Valid Instruction In
ALE Low to PSEN Low
2.5 tCLCL - 20
2.0 tCLCL - 20
tLLPL
0.5 tCLCL - 5
2.0 tCLCL - 5
tPLPH
PSEN Pulse Width
tPLIV
tPXIX
nS
nS
nS
nS
nS
nS
nS
nS
nS
PSEN Low to Valid Instruction In
Input Instruction Hold After PSEN
Input Instruction Float After PSEN
Port 0 Address to Valid Instr. In
Port 2 Address to Valid Instr. In
0
tPXIZ
tCLCL - 5
tAVIV1
tAVIV2
tPLAZ
tRHDX
tRHDZ
tRLAZ
3.0 tCLCL - 20
3.5 tCLCL - 20
0
0
PSEN Low to Address Float
Data Hold After Read
Data Float After Read
tCLCL - 5
0.5 tCLCL - 5
RD Low to Address Float
- 74 -
Preliminary W77E516
MOVX Characteristics Using Strech Memory Cycles
VARIABLE
VARIABLE
PARAMETER
SYM.
CLOCK
MIN.
CLOCK
MAX.
UNITS STRECH
1.5 tCLCL - 5
2.0 tCLCL - 5
tMCS = 0
Data Access ALE Pulse Width
tLLHL2
tLLAX2
tRLRH
tWLWH
nS
tMCS > 0
Address Hold After ALE Low for
MOVX Write
0.5 tCLCL - 5
nS
2.0 tCLCL - 5
tMCS - 10
tMCS = 0
nS
nS
nS
RD Pulse Width
WR Pulse Width
tMCS > 0
2.0 tCLCL - 5
tMCS - 10
tMCS = 0
tMCS > 0
2.0 tCLCL - 20
tMCS - 20
tMCS = 0
tRLDV
tRHDX
tRHDZ
RD Low to Valid Data In
Data Hold after Read
Data Float after Read
tMCS > 0
0
nS
tCLCL - 5
tMCS = 0
nS
2.0 tCLCL - 5
2.5 tCLCL - 5
tMCS > 0
tMCS = 0
ALE Low to Valid Data In
tLLDV
nS
tMCS + 2tCLCL
- 40
tMCS > 0
3.0 tCLCL - 20
2.0tCLCL - 5
tMCS = 0
Port 0 Address to Valid Data In
Port 2 Address to Valid Data In
ALE Low to RD or WR Low
tAVDV1
tAVDV2
tLLWL
nS
nS
nS
nS
nS
nS
nS
tMCS > 0
3.5 tCLCL - 20
2.5 tCLCL - 5
0.5 tCLCL + 5
1.5 tCLCL + 5
tMCS = 0
tMCS > 0
0.5 tCLCL - 5
1.5 tCLCL - 5
tCLCL - 5
tMCS = 0
tMCS > 0
tMCS = 0
Port 0 Address to RD or WR
Low
tAVWL
tAVWL2
tQVWX
2.0 tCLCL - 5
tMCS > 0
1.5 tCLCL - 5
2.5 tCLCL - 5
-5
tMCS = 0
Port 2 Address to RD or WR
Low
tMCS > 0
tMCS = 0
Data Valid to WR Transition
1.0 tCLCL - 5
tCLCL - 5
tMCS > 0
tMCS = 0
Data Hold after Write
tWHQX
tRLAZ
2.0 tCLCL - 5
tMCS > 0
0.5 tCLCL - 5
nS
RD Low to Address Float
RD or WR High to ALE High
0
10
tMCS = 0
nS
tWHLH
1.0 tCLCL - 5
1.0 tCLCL + 5
tMCS > 0
Note: tMCS is a time period related to the Stretch memory cycle selection. The following table shows the time period of tMCS for
each selection of the Stretch value.
Publication Release Date: August 16, 2002
- 75 -
Revision A1
Preliminary W77E516
M2
0
M1
0
M0
0
MOVX Cycles
2 machine cycles
3 machine cycles
4 machine cycles
5 machine cycles
6 machine cycles
7 machine cycles
8 machine cycles
9 machine cycles
tMCS
0
0
0
1
4 tCLCL
8 tCLCL
12 tCLCL
16 tCLCL
20 tCLCL
24 tCLCL
28 tCLCL
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
Explanation of Logic Symbols
In order to maintain compatibility with the original 8051 family, this device specifies the same
parameter for each device, using the same symbols. The explanation of the symbols is as follows.
t
C
H
Time
Clock
Logic level high
A
D
L
Address
Input Data
Logic level low
I
Instruction
P
R
PSEN
Q
Output Data
RD signal
V
X
Valid
W
Z
WR signal
Tri-state
No longer a valid state
12. TIMING WAVEFORMS
Program Memory Read Cycle
tLHLL
tLLIV
ALE
tAVLL
tPLPH
tPLIV
tLLPL
PSEN
tPXIZ
tPLAZ
tPXIX
tLLAX1
ADDRESS
A0-A7
INSTRUCTION
IN
ADDRESS
A0-A7
PORT 0
PORT 2
tAVIV1
tAVIV2
ADDRESS A8-A15
ADDRESS A8-A15
- 76 -
Preliminary W77E516
Timing Waveforms, continued
Data Memory Read Cycle
tLLDV
ALE
PSEN
RD
tWHLH
tLLWL
tRLRH
tRLDV
tLLAX1
tAVLL
tAVWL1
tRHDZ
tRLAZ
tRHDX
PORT 0 INSTRUCTION
IN
DATA
IN
ADDRESS
A0-A7
ADDRESS
A0-A7
tAVDV1
tAVDV2
ADDRESS A8-A15
PORT 2
Data Memory Write Cycle
ALE
tWHLH
tLLWL
PSEN
WR
tWLWH
tLLAX2
tAVLL
tAVWL1
tWHQX
tQVWX
PORT 0 INSTRUCTION
IN
ADDRESS
A0-A7
ADDRESS
A0-A7
DATA OUT
tAVDV2
PORT 2
ADDRESS A8-A15
Publication Release Date: August 16, 2002
Revision A1
- 77 -
Preliminary W77E516
13. TYPICAL APPLICATION CIRCUITS
Expanded External Program Memory and Crystal
V
CC
V
CC
31
19
AD0
39
3
4
7
8
11
12
13
15
16
17
18
19
AD0
AD1
AD2
AD3
AD0
AD1
AD2
AD3
AD4
AD5
AD6
AD7
2
5
6
9
A0
A1
A2
A3
A0
A1
A2
A3
A4
A5
A6
A7
10
9
D0
D1
D2
D3
D4
D5
D6
D7
Q0
Q1
Q2
Q3
Q4
Q5
Q6
Q7
P0.0
P0.1
P0.2
P0.3
P0.4
P0.5
P0.6
P0.7
A0
O0
O1
O2
O3
O4
O5
O6
O7
EA
38 AD1
37 AD2
36 AD3
35 AD4
A1
8
A2
A3
XTAL1
10 u
7
6
AD4 13
14
AD6 17
AD7 18
12 A4
15 A5
16 A6
A4
R
18
9
AD5
34
33 AD6
AD5
5
XTAL2
A5
CRYSTAL
4
A6
AD7
3
32
19
A7
A7
8.2 K
RST
INT0
A8 25
A8
1
GND
A8
A9
A9
A10
A11
A12
24
21
23
2
21
22
23
24
25
26
27
28
OC
G
P2.0
P2.1
P2.2
P2.3
P2.4
P2.5
P2.6
P2.7
A9
C1
C2
11
A10
A11
A12
A13
A14
12
13
14
15
A10
A11
A12
A13
A14
A15
INT1
T0
T1
74F373
A13 26
A14
1
20
CE
GND
1
2
3
4
5
6
7
8
P1.0
P1.1
P1.2
P1.3
P1.4
P1.5
P1.6
P1.7
22
27
OE
WR
RD
17
16
WR
PSEN
ALE
TXD
RXD
29
20256
30
11
10
W77E516
Figure A
CRYSTAL
16 MHz
24 MHz
33 MHz
40 MHz
C1
30P
15P
5P
C2
R
-
30P
15P
5P
-
4.7K
3.3K
1P
1P
The above table shows the reference values for crystal applications.
Note: C1, C2, R components refer to Figure A.
- 78 -
Preliminary W77E516
Typical Application Circuits, continued
Expanded External Data Memory and Oscillator
V
CC
V
CC
31
19
AD0
AD1
AD2
AD3
AD4
AD5 14
AD6 17
AD7 18
3
4
A0
A1
A2
A3
11
12
13
15
16
17
18
19
AD0
AD1
AD2
AD3
AD4
AD5
AD6
AD7
39 AD0
2
5
6
9
10
9
A0
A1
A2
A3
A4
A5
A6
A7
P0.0
P0.1
P0.2
P0.3
P0.4
P0.5
P0.6
P0.7
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
D0
D1
D2
D3
D4
D5
D6
D7
D0 Q0
D1 Q1
D2 Q2
D3 Q3
D4 Q4
D5 Q5
D6 Q6
D7 Q7
EA
AD1
38
37 AD2
36 AD3
7
8
XTAL1
8
13
7
10 u
OSCILLATOR
AD4
AD5
12 A4
15 A5
16 A6
19 A7
35
34
6
18
9
5
XTAL2
33 AD6
32 AD7
4
8.2 K
3
A8 25
RST
INT0
GND
1
11
21
A8
A9 24
P2.0
P2.1
P2.2
P2.3
P2.4
P2.5
P2.6
P2.7
OC
G
22 A9
21
23
2
26
1
A10
A11
A12
A13
A14
A10
A11
A12
A13
12
23
A10
24
13
14
15
A11
74F373
INT1
T0
T1
25
A12
26
A13
A14
27
28
A14
CE
GND
1
2
3
4
5
6
7
8
20
22
27
P1.0
P1.1
P1.2
P1.3
P1.4
P1.5
P1.6
P1.7
OE
RD
WR
17
16
29
30
11
10
WR
20256
PSEN
ALE
TXD
RXD
W77E516
Figure B
14. PACKAGE DIMENSIONS
40-pin DIP
Dimension in inches
Min. Nom. Max.
0.210
Dimension in mm
Symbol
Min. Nom. Max.
5.334
A
A
A
0.010
0.254
1
2
0.150
0.016
0.048
0.008
0.155
0.018
0.050
0.010
2.055
0.160
0.022
0.054
0.014
2.070
0.610
3.81
3.937
0.457
1.27
4.064
0.559
1.372
0.356
52.58
15.494
13.97
2.794
0.406
1.219
0.203
B
1
B
0.254
52.20
15.24
13.84
2.54
c
D
E
D
40
21
0.590
0.540
0.090
0.600
0.545
0.100
14.986
13.72
0.550
0.110
1
1
E
e
2.286
3.048
0
0.120
0
0.130
0.140
15
3.302
3.556
15
E
1
L
a
0.630
0.650
0.670
0.090
16.00
16.51
17.01
2.286
A
e
S
1
20
Notes:
E
1. Dimension D Max. & S include mold flash or
tie bar burrs.
S
c
2. Dimension E1 does not include interlead flash.
3. Dimension D & E1 include mold mismatch and
are determined at the mold parting line.
A
2
A
L
A1
Base Plane
.
Seating Plane
4. Dimension B1 does not include dambar
protrusion/intrusion.
B
B
e 1
e A
5. Controlling dimension: Inches.
6. General appearance spec. should be based on
final visual inspection spec.
a
1
Publication Release Date: August 16, 2002
Revision A1
- 79 -
Preliminary W77E516
Package Dimensions, continued
44-pin PLCC
H D
D
6
1
44
40
Dimension in inches
Min. Nom. Max. Min. Nom. Max.
0.185
Dimension in mm
Symbol
A
7
39
4.699
0.020
0.145 0.150 0.155 3.683 3.81 3.937
0.508
A
A
b
b
c
1
2
1
0.026 0.028
0.016 0.018
0.032 0.66
0.406
0.813
0.559
0.356
0.711
0.457
0.022
HE
GE
E
0.008 0.010 0.014 0.203 0.254
16.46 16.59 16.71
16.46 16.59 16.71
1.27 BSC
0.648 0.653 0.658
0.648 0.653
0.050 BSC
D
E
e
0.658
0.590
0.590
0.680
0.680
0.630 14.99 15.49 16.00
17
29
0.610
D
E
D
G
G
H
H
L
y
14.99 15.49 16.00
17.27 17.53 17.78
17.27 17.53 17.78
0.610 0.630
0.690 0.700
0.690 0.700
18
28
c
E
0.090 0.100
2.54 2.794
0.10
0.110 2.296
0.004
L
Notes:
A2
A
1. Dimension D & E do not include interlead
flash.
2. Dimension b1 does not include dambar
protrusion/intrusion.
q
e
b
A1
3. Controlling dimension: Inches
4. General appearance spec. should be based
on final visual inspection spec.
b 1
y
Seating Plane
G D
44-pin QFP
H D
Dimension in inch
Dimension in mm
D
Symbol
A
Min. Nom. Max. Min. Nom. Max.
34
44
---
---
---
---
---
---
0.002
0.01
0.02
0.25
2.05
0.05
1.90
0.5
A
A
b
1
0.081 0.087
2.20
0.45
0.254
0.075
0.01
2
33
1
0.014
0.006
0.394
0.394
0.031
0.25
0.018
0.010
0.398
0.398
0.036
0.530
0.35
0.101 0.152
0.004
0.390
c
10.00
9.9
9.9
10.1
10.1
0.952
13.45
13.45
0.95
1.905
0.08
7
D
E
e
0.390
0.025
10.00
0.80
E
HE
0.635
12.95
12.95
0.65
0.510 0.520
13.2
13.2
0.8
HD
0.520 0.530
0.510
H
L
E
11
0.025 0.031
0.037
0.051 0.063 0.075
0.003
1.295
1.6
L
y
1
12
22
e
b
0
7
0
q
Notes:
1. Dimension D & E do not include interlead
flash.
c
2. Dimension b does not include dambar
protrusion/intrusion.
3. Controlling dimension: Millimeter
4. General appearance spec. should be based
on final visual inspection spec.
A
A
2
1
q
A
L
See Detail F
y
Seating Plane
L
1
Detail F
- 80 -
Preliminary W77E516
15. APPLICATION NOTE
In-system Programming Software Examples
This application note illustrates the in-system programmability of the Winbond W77E516 MTP-ROM
microcontroller. In this example, microcontroller will boot from 64 KB APROM bank and waiting for a
key to enter in-system programming mode for re-programming the contents of 64 KB APROM.
While entering in-system programming mode, microcontroller executes the loader program in 4KB
LDROM bank. The loader program erases the 64 KB APROM then reads the new code data from
external SRAM buffer (or through other interfaces) to update the 64KB APROM.
EXAMPLE 1:
;*******************************************************************************************************************
;* Example of 64K APROM program: Program will scan the P1.0. if P1.0 = 0, enters in-system
;* programming mode for updating the content of APROM code else executes the current ROM code.
;* XTAL = 24 MHz
;*******************************************************************************************************************
.chip 8052
.RAMCHK OFF
.symbols
CHPCON
TA
SFRAL
SFRAH
SFRFD
SFRCN
EQU
EQU
EQU
EQU
EQU
EQU
9FH
C7H
ACH
ADH
AEH
AFH
ORG
LJMP 100H
0H
; JUMP TO MAIN PROGRAM
;************************************************************************
;* TIMER0 SERVICE VECTOR ORG = 000BH
;************************************************************************
ORG
CLR
00BH
TR0
; TR0 = 0, STOP TIMER0
MOV
MOV
RETI
TL0,R6
TH0,R7
;************************************************************************
;* 64K APROM MAIN PROGRAM
;************************************************************************
ORG
100H
MAIN_64K:
MOV
A,P1
; SCAN P1.0
ANL
A,#01H
CJNE
JMP
A,#01H,PROGRAM_64K ; IF P1.0 = 0, ENTER IN-SYSTEM PROGRAMMING MODE
NORMAL_MODE
PROGRAM_64:
MOV
TA,#AAH
; CHPCON register is written protect by TA register.
MOV
TA,#55H
MOV
CHPCON,#03H
; CHPCON = 03H, ENTER IN-SYSTEM PROGRAMMING MODE
Publication Release Date: August 16, 2002
- 81 -
Revision A1
Preliminary W77E516
MOV
SFRCN,#30H
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
TCON,#00H
IP, #00H
IE, #82H
R6, #F0H
R7, #FFH
TL0, R6
; TR = 0 TIMER0 STOP
; IP = 00H
; TIMER0 INTERRUPT ENABLE FOR WAKE-UP FROM IDLE MODE
; TL0 = F0H
; TH0 = FFH
TH0, R7
TMOD, #01H
TCON, #10H
PCON, #01H
; TMOD = 01H, SET TIMER0 A 16-BIT TIMER
; TCON = 10H, TR0 = 1,GO
; ENTER IDLE MODE FOR LAUNCHING THE IN-SYSTEM PROGRAMMING
;************** ******************************************************************
;* Normal mode 64KB APROM program: depending user's application
;********************************************************************************
NORMAL_MODE:
.
; User's application program
.
.
.
EXAMPLE 2:
;***************************************************************************************************************************** ;*
Example of 4KB LDROM program: This loader program will erase the 64KB APROM first, then reads the new ;*
code from external SRAM and program them into 64KB APROM bank. XTAL = 24 MHz
;*****************************************************************************************************************************
.chip 8052
.RAMCHK OFF
.symbols
CHPCON
TA
SFRAL
SFRAH
SFRFD
SFRCN
EQU
EQU
EQU
EQU
EQU
EQU
9FH
C7H
ACH
ADH
AEH
AFH
ORG 000H
LJMP 100H
; JUMP TO MAIN PROGRAM
;************************************************************************
;* 1. TIMER0 SERVICE VECTOR ORG = 0BH
;************************************************************************
ORG 000BH
CLR
TR0
; TR0 = 0, STOP TIMER0
MOV
MOV
RETI
TL0, R6
TH0, R7
;************************************************************************
;* 4KB LDROM MAIN PROGRAM
;************************************************************************
ORG 100H
MAIN_4K:
- 82 -
Preliminary W77E516
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
TA, #AAH
TA, #55H
CHPCON, #03H
TCON, #00H
TMOD, #01H
IP, #00H
IE, #82H
R6, #F0H
R7, #FFH
TL0, R6
; CHPCON = 03H, ENABLE IN-SYSTEM PROGRAMMING.
; TCON = 00H, TR = 0 TIMER0 STOP
; TMOD = 01H, SET TIMER0 A 16BIT TIMER
; IP = 00H
; IE = 82H, TIMER0 INTERRUPT ENABLED
TH0, R7
TCON, #10H
PCON, #01H
; TCON = 10H, TR0 = 1, GO
; ENTER IDLE MODE
UPDATE_64K:
MOV
MOV
MOV
MOV
MOV
TCON, #00H
IP, #00H
IE, #82H
TMOD,#01H
R6, #D0H
; TCON = 00H , TR = 0 TIM0 STOP
; IP = 00H
; IE = 82H, TIMER0 INTERRUPT ENABLED
; TMOD = 01H, MODE1
; SET WAKE-UP TIME FOR ERASE OPERATION, ABOUT 15 mS
DEPENDING ON USER'S SYSTEM CLOCK RATE.
MOV
MOV
MOV
R7,#8AH
TL0,R6
TH0,R7
ERASE_P_4K:
MOV
SFRCN, #22H
; SFRCN = 22H, ERASE 64K
APROM0
; SFRCN = A2H, ERASE 64K APROM1
; TCON = 10H, TR0 = 1,GO
; ENTER IDLE MODE (FOR ERASE OPERATION)
MOV
MOV
TCON, #10H
PCON, #01H
;*********************************************************************
;* BLANK CHECK
;*********************************************************************
MOV
SFRCN, #0H
; SFRCN = 00H, READ 64KB APROM0
; SFRCN = 80H, READ 64KB APROM1
; START ADDRESS = 0H
MOV
MOV
MOV
MOV
MOV
MOV
SFRAH, #0H
SFRAL, #0H
R6, #FDH
R7, #FFH
TL0, R6
; SET TIMER FOR READ OPERATION, ABOUT 1.5 mS.
TH0, R7
BLANK_CHECK_LOOP:
SETB
MOV
MOV
CJNE
INC
TR0
PCON, #01H
A, SFRFD
A, #FFH, BLANK_CHECK_ERROR
SFRAL ; NEXT ADDRESS
; ENABLE TIMER 0
; ENTER IDLE MODE
; READ ONE BYTE
MOV
JNZ
A, SFRAL
BLANK_CHECK_LOOP
INC
SFRAH
MOV
CJNE
JMP
A, SFRAH
A, #0H,BLANK_CHECK_LOOP ; END ADDRESS = FFFFH
PROGRAM_64KROM
Publication Release Date: August 16, 2002
Revision A1
- 83 -
Preliminary W77E516
BLANK_CHECK_ERROR:
JMP
$
;*******************************************************************************
;* RE-PROGRAMMING 64KB APROM BANK
;*******************************************************************************
PROGRAM_64KROM:
MOV
MOV
MOV
MOV
MOV
R2, #00H
R1, #00H
DPTR, #0H
SFRAH, R1
SFRCN, #21H
; TARGET LOW BYTE ADDRESS
; TARGET HIGH BYTE ADDRESS
; SFRAH, TARGET
HIGH ADDRESS
; SFRCN = 21H, PROGRAM 64K APROM0
; SFRCN = A1H, PROGRAM 64K APROM1
; SET TIMER FOR PROGRAMMING, ABOUT 50 mS.
MOV
MOV
MOV
MOV
R6, #9CH
R7, #FFH
TL0, R6
TH0, R7
PROG_D_64K:
MOV
CALL
SFRAL,R2
; SFRAL = LOW BYTE ADDRESS
GET_BYTE_FROM_PC_TO_ACC ; THIS PROGRAM IS BASED ON USER’S CIRCUIT.
MOV
MOV
MOV
MOV
INC
@DPTR, A
SFRFD, A
TCON, #10H
PCON, #01H
DPTR
; SAVE DATA
; SFRFD = DATA IN
; TCON = 10H, TR0 = 1,GO
; ENTER IDLE MODE (PRORGAMMING)
INTO SRAM TO VERIFY CODE.
INC
R2
CJNE
INC
R2, #0H, PROG_D_64K
R1
MOV
CJNE
SFRAH, R1
R1,#0H, PROG_D_64K
;*****************************************************************************
; * VERIFY 64KB APROM BANK
;*****************************************************************************
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
MOV
R4, #03H
R6, #FDH
R7, #FFH
TL0, R6
TH0, R7
DPTR, #0H
R2, #0H
R1, #0H
SFRAH, R1
SFRCN, #00H
; ERROR COUNTER
; SET TIMER FOR READ VERIFY, ABOUT 1.5 mS.
; The start address of sample code
; Target
; Target
low byte address
high byte address
; SFRAH, Target high address
; SFRCN = 00H, Read APROM0
;SFRCN = 80H , Read APROM1
READ_VERIFY_64K:
MOV
MOV
MOV
INC
SFRAL,R2
; SFRAL = LOW ADDRESS
; TCON = 10H, TR0 = 1,GO
TCON, #10H
PCON, #01H
R2
MOVX
INC
A, @DPTR
DPTR
CJNE
A, SFRFD, ERROR_64K
- 84 -
Preliminary W77E516
CJNE
INC
R2, #0H, READ_VERIFY_64K
R1
MOV
CJNE
SFRAH, R1
R1, #0H, READ_VERIFY_64K
;******************************************************************************
;* PROGRAMMING COMPLETLY, SOFTWARE RESET CPU
;******************************************************************************
MOV
MOV
MOV
TA, #AAH
TA, #55H
CHPCON, #83H
; SOFTWARE RESET.
CPU will restart from APROM0
ERROR_64K:
DJNZ
R4, UPDATE_64K
; IF ERROR OCCURS, REPEAT 3 TIMES.
; IN-SYST PROGRAMMING FAIL, USER'S PROCESS TO DEAL
WITH IT.
.
Headquarters
Winbond Electronics Corporation America Winbond Electronics (Shanghai) Ltd.
27F, 2299 Yan An W. Rd. Shanghai,
2727 North First Street, San Jose,
No. 4, Creation Rd. III,
Science-Based Industrial Park,
Hsinchu, Taiwan
TEL: 886-3-5770066
FAX: 886-3-5665577
200336 China
CA 95134, U.S.A.
TEL: 1-408-9436666
FAX: 1-408-5441798
TEL: 86-21-62365999
FAX: 86-21-62365998
http://www.winbond.com.tw/
Taipei Office
Winbond Electronics Corporation Japan
7F Daini-ueno BLDG, 3-7-18
Shinyokohama Kohoku-ku,
Yokohama, 222-0033
Winbond Electronics (H.K.) Ltd.
Unit 9-15, 22F, Millennium City,
No. 378 Kwun Tong Rd.,
Kowloon, Hong Kong
9F, No.480, Rueiguang Rd.,
Neihu Chiu, Taipei, 114,
Taiwan, R.O.C.
TEL: 886-2-8177-7168
FAX: 886-2-8751-3579
TEL: 81-45-4781881
FAX: 81-45-4781800
TEL: 852-27513100
FAX: 852-27552064
Please note that all data and specifications are subject to change without notice.
All the trade marks of products and companies mentioned in this data sheet belong to their respective owners.
Publication Release Date: August 16, 2002
Revision A1
- 85 -
相关型号:
W77E516A40DL
Microcontroller, 8-Bit, FLASH, 8051 CPU, 40MHz, CMOS, PDIP40, ROHS COMPLIANT, DIP-40
WINBOND
W77E516A40FL
Microcontroller, 8-Bit, FLASH, 8051 CPU, 40MHz, CMOS, PQFP44, ROHS COMPLIANT, QFP-44
WINBOND
W77E516A40PL
Microcontroller, 8-Bit, FLASH, 8051 CPU, 40MHz, CMOS, PQCC44, ROHS COMPLIANT, PLASTIC, LCC-44
WINBOND
©2020 ICPDF网 联系我们和版权申明