AEJ50US48 [XPPOWER]
AC-DC Power Supplies;型号: | AEJ50US48 |
厂家: | XP POWER LIMITED |
描述: | AC-DC Power Supplies |
文件: | 总4页 (文件大小:621K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AC-DC Power Supplies
AEJ50 Series
50 Watts
• Energy Efficiency Level VI
• European CoC Tier 2
• <0.15 W Standby Power
• Single Output 12 to 48 V
• 0 °C to 65 °C Operation
• Universal Input
• 3 Year Warranty
Dimensions:
AEJ50:
4.72 x 2.05 x 1.22” (120.0 x 52.0 x 31.0 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
Total Regulation
Efficiency(1)
Model Number
12.0 V
15.0 V
19.0 V
24.0 V
28.0 V
36.0 V
48.0 V
4.20 A
3.36 A
2.65 A
2.10 A
1.80 A
1.40 A
1.05 A
89%
89%
89%
89%
89%
89%
89%
AEJ50US12
AEJ50US15
AEJ50US19
AEJ50US24
AEJ50US28
AEJ50US36
AEJ50US48
50 W
5%
Notes
1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 230 VAC input.
Mechanical Details
Cable length
12-19 V:
48” (1220 mm) 16 AWG
24-48 V:
48” (1220 mm) 18 AWG
2.09
(53.0)
0.47
(12.00)
4.72
(120.0)
IEC320-C14
1.24
(31.5)
Notes
1. All dimensions shown in inches (mm).
2. Weight: 0.60 lbs (300 g) approx.
4. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center +
and outer shell - polarity.
3. Tolerance is 0.02 ( 0.5) maximum, except output cable length
which is 2” ( 50 mm)
www.xppower.com
1
AC-DC Power Supplies
AEJ50 Series
Input
Characteristic
Minimum
Typical
Maximum
264
Units
Notes & Conditions
Input Voltage
90
47
VAC
Input Frequency
Input Current
Inrush Current
Earth Leakage Current
No Load Input Power
Input Protection
63
Hz
A
A
µA
W
1.20
Measured at 100VAC
230 VAC, cold start at 25 °C
264 VAC, 60 Hz
50
350
0.15
T2.0A/250 VAC internal fuse in line
Output
Characteristic
Min.
Typ.
Max.
Units
Notes & Conditions
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
12
48
2
VDC
%
See Models and Ratings table
At 60% load
No minimum load required
3
20
s
ms
ms
%
8
Full load and 115 VAC
Line Regulation
Total Regulation
1
4
%
Maximum deviation, recovering to less than 1% within
500 µs for 25% step load
Transient Response
5
%
Measured with 20 MHz Bandwidth and 10 µF electrolytic in
parallel with 0.1 µF ceramic capacitor.
Ripple and Noise
1
% pk-pk
Overshoot
10
175
125
%
%
%
At turn on / turn off
Overload Protection
Overvoltage Protection
Short Circuit Protection
Temperature Coefficient
115
112
Recycle mains to reset
Trip and restart (hiccup), auto resetting
0.05
%/°C
Environmental
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Operating Temperature
Cooling
-20
+65
°C
Derate from 100% load at 50 °C to 58% load at 65 °C
Natural convection
Operating Humidity
Storage Temperature
Operating Altitude
Shock
5
-40
90
+85
5000
%RH
°C
m
Non-condensing
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes
Vibration
IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes
Derating Curve
100
80
60
40
20
65
-20
50
Ambient Temperature (ºC)
www.xppower.com
2
AC-DC Power Supplies
AEJ50 Series
General
Characteristic
Minimum
Typical
Maximum
Units
%
Notes & Conditions
Efficiency
89
See Models and Ratings table and curves.
3000
1500
VAC
VAC
Isolation: Input to Output
Input to Ground
Output to Ground
Negative output is connected to ground
Switching Frequency
Power Density
65
kHz
3
4.23
W/in
Mean Time Between Failure
Weight
285
kHrs
lb (g)
MIL-HDBK-217F at 25 °C GB for 24 V version
0.60 (300)
Efficiency Curves
AEJ50US12
100%
90%
80%
70%
60%
50%
115Vac input
230Vac input
10
20
30
40
50
60
70
80
90
100
Load (%)
AEJ50US24
100%
90%
80%
70%
60%
50%
115Vac input
230Vac input
10
20
30
40
50
60
70
80
90
100
Load (%)
EMC: Emissions
Phenomenon
Standard
EN55022
EN61000-3-2
EN61000-3-3
Test Level
Notes & Conditions
Emissions
Harmonic Current
Voltage Flicker
Level B
Class A
Conducted & Radiated
www.xppower.com
3
AC-DC Power Supplies
AEJ50 Series
EMC: Immunity
Phenomenon
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Test Level
Criteria
Notes & Conditions
ESD
8 kV Air, 6 kV contact
3 V/m
A
A
A
A
A
Radiated
EFT/Burst
Surge
Conducted
Magnetic Fields
2
Installation Class 3
3 V
3 A/m
A
Dip: 30% 500 ms
Dip: 60% 100 ms
Int: 100% 5000 ms
Int: 100% 10 ms
A/B
A/B
B
High Line/Low Line
High Line/Low Line
Dips and Interruptions
EN61000-4-11
A
Safety Approvals
Safety Agency
Safety Standard
UL60950-1
Notes & Conditions
UL
TUV
CB
EN60950-1
IEC60950-1
Mechanical Details
Cable length
12-19 V:
48” (1220 mm) 16 AWG
24-48 V:
48” (1220 mm) 18 AWG
2.09
(53.0)
0.47
(12.00)
4.72
(120.0)
IEC320-C14
1.24
(31.5)
Notes
1. All dimensions shown in inches (mm).
2. Weight: 0.60 lbs (300 g) approx.
4. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center +
and outer shell - polarity.
3. Tolerance is 0.02 ( 0.5) maximum, except output cable length
which is 2” ( 50 mm)
www.xppower.com
07 June 16
相关型号:
©2020 ICPDF网 联系我们和版权申明