AEK40US12 [XPPOWER]
AC-DC Power Supplies;型号: | AEK40US12 |
厂家: | XP POWER LIMITED |
描述: | AC-DC Power Supplies |
文件: | 总4页 (文件大小:547K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AC-DC Power Supplies
XP Power
AEK40 Series
40 Watts
• Energy Efficiency Level VI
• European CoC Tier 2
• <0.075 W Standby Power
• Single Outputs 5 to 48 V
• 0 °C to 60 °C Operation
• Universal Input
• 3 Year Warranty
Dimensions:
AEK40:
4.21 x 1.85 x 1.19” (107.0 x 47.0 x 30.1 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
Total Regulation
Ripple & Noise(3)
Efficiency(1)
Model Number
25 W
5.0 V
12.0 V
15.0 V
18.0 V
24.0 V
48.0 V
5.00 A
3.33 A
2.67 A
2.22 A
2.08 A
1.04 A
50 mV
100 mV
100 mV
100 mV
100 mV
100 mV
85.9%
88.5%
88.5%
88.0%
88.0%
88.0%
AEK40US05
AEK40US12
AEK40US15
AEK40US18
40 W
50 W
5%
(2)
AEK40US24
(2)
AEK40US48
Notes
1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load
and 230 VAC input.
2. No load input power is <0.15 W.
3. Pk Pk value measured with 20 MHz bandwidth and 0.47 µF ceramic capacitor.
Mechanical Details
1.19 (30.1)
0.02 (0.5)
4.21 (107.0)
AC INPUT
IEC320-C14 INLET
Notes
1. All dimensions shown in inches (mm).
2. Weight: 0.38 lbs (190 g) approx.
3. Tolerance is 0.02 ( 0.5) maximum, except output cable length
which is 2” ( 50 mm)
4. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center +
and outer shell - polarity.
5. Cable length: 5 & 12 V: 48” (1220 mm) 16 AWG
Others: 48” (1220 mm) 18 AWG
www.xppower.com
1
AC-DC Power Supplies
AEK40 Series
Input
Characteristic
Minimum
Typical
Maximum
264
Units
Notes & Conditions
Input Voltage
90
47
VAC
Input Frequency
Input Current
Inrush Current
Leakage Current
No Load Input Power
Input Protection
63
Hz
A
A
mA
mW
0.9/0.52
Measured at 100 VAC/240 VAC
230 VAC, cold start at 25 °C
240 VAC, 60 Hz
110
0.75
75
150 mW for 24 V and 48 V models
T2.0A/250 VAC internal fuse in line
Output
Characteristic
Min.
Typ.
Max.
Units
Notes & Conditions
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Hold Up Time
5
48
2
VDC
%
See Models and Ratings table
At 60% load
No minimum load required
2
s
12
ms
%
%
Full load and 115 VAC
Line Regulation
Load Regulation
1
4
From minimum to maximum input voltage at full load
Load regulation measured from 10% to 100% load
Maximum deviation, recovering to less than 1% within
500 µs for 25% step load
Transient Response
5
%
Ripple and Noise
mV pk-pk
See Models and Ratings table
Overshoot
5
%
%
At turn on / turn off
Overload Protection
Short Circuit Protection
Temperature Coefficient
110
150
Trip and restart (hiccup), auto resetting
0.04
%/°C
Environmental
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Operating Temperature
Cooling
0
+60
°C
Derate from 100% load at 40 °C to 67% load at 60 °C
Natural convection
Operating Humidity
Storage Temperature
Operating Altitude
Shock
0
-40
95
+85
5000
%RH
°C
m
Non-condensing
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes
Vibration
IEC68-2-6, 10-500 Hz, 5 g 10 mins/sweep, 60 mins for each of 3 axes
Derating Curve
100
80
60
40
20
60
0
40
Ambient Temperature (ºC)
www.xppower.com
2
AC-DC Power Supplies
AEK40 Series
General
Characteristic
Minimum
Typical
Maximum
Units
%
Notes & Conditions
Efficiency
88
See Models and Ratings table and curves.
Isolation: Input to Ground
Isolation: Input to Output
Isolation: Output to Ground
Switching Frequency
Power Density
1500
3000
500
VAC
VAC
VDC
kHz
65
3
4.3
W/in
Mean Time Between Failure
Weight
100
kHrs
lb (g)
MIL-HDBK-217F at 25 °C GB
0.38 (190)
Efficiency Curves
AEK40US12
100%
90%
80%
70%
60%
50%
115Vac input
230Vac input
10
20
30
40
50
60
70
80
90
100
Load (%)
AEK40US24
100%
90%
80%
70%
60%
50%
115Vac input
230Vac input
10
20
30
40
50
60
70
80
90
100
Load (%)
EMC: Emissions
Phenomenon
Standard
Test Level
Notes & Conditions
Conducted & Radiated
Emissions
Harmonic Current
Voltage Flicker
EN55022
EN61000-3-2
EN61000-3-3
Level B
Class A
www.xppower.com
3
AC-DC Power Supplies
AEK40 Series
EMC: Immunity
Phenomenon
Standard
Test Level
Criteria
Notes & Conditions
ESD
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
8 kV Air, 6 kV contact
3 V/m
A
A
A
A
A
Radiated
EFT/Burst
Surge
Conducted
Magnetic Fields
2
Installation Class 3
3 V
3 A/m
A
Dip: 30% 10 ms
Dip: 60% 100 ms
Int: 100% 5000 ms
A
A/B
B
High Line/Low Line
Dips and Interruptions
EN61000-4-11
Safety Approvals
Safety Agency
Safety Standard
UL60950-1
Notes & Conditions
UL
TUV
CB
EN60950-1
IEC60950-1
Mechanical Details
1.19 (30.1)
4.21 (107.0)
0.02 (0.5)
AC INPUT
IEC320-C14 INLET
Notes
1. All dimensions shown in inches (mm).
2. Weight: 0.38 lbs (190 g) approx.
3. Tolerance is 0.02 ( 0.5) maximum, except output cable length
which is 2” ( 50 mm)
4. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center +
and outer shell - polarity.
5. Cable length: 5 & 12 V: 48” (1220 mm) 16 AWG
Others: 48” (1220 mm) 18 AWG
www.xppower.com
06 Feb 17