AG60N-12T [XPPOWER]
DC-DC Regulated Power Supply Module,;型号: | AG60N-12T |
厂家: | XP POWER LIMITED |
描述: | DC-DC Regulated Power Supply Module, |
文件: | 总10页 (文件大小:1079K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AG SERIES
ISOLATED, PROPORTIONAL DC TO HV DC CONVERTERS
100V to 6000V @ 1.0 and 1.5 Watts
PRODUCT SELECTION TABLE
Extremely Low Profile: 0.128 inches
and volume of < 0.100 cubic inches
*5
STANDARD 1 WATT -
AG MODEL
1.5 WATT OPTION -
AGH MODEL
VDC
MAXIMUM
MAXIMUM
MODEL
OUTPUT
MODEL
OUTPUT
CURRENT*1
CURRENT*1
*7
100 VDC
200 VDC
250 VDC
300 VDC
400 VDC
500 VDC
600 VDC
700 VDC
800 VDC
900 VDC
1000 VDC
1200 VDC
1500 VDC
2000 VDC
3000 VDC
4000 VDC
5000 VDC
6000 VDC
AG01
AG02
AG025
AG03
AG04
AG05
AG06
AG07
AG08
AG09
AG10
AG12
AG15
AG20
AG30
AG40
AG50
AG60
10 mA
5 mA
AGH01
AGH02
AGH025
AGH03
15 mA
7.5 mA
6 mA
4 mA
3.33 mA
2.5 mA
2 mA
5mA
AGH04 3.75 mA
AGH05
AGH06
AGH07
AGH08
AGH09
AGH10
AGH12
AGH15
AGH20
AGH30
–
3 mA
2.5 mA
2.15 mA
1.87 mA
1.67 mA
1.5 mA
1.25 mA
1 mA
PRODUCT DESCRIPTION
1.67 mA
1.43 mA
1.25 mA
1.1 mA
1 mA
The AG Series is a new line of ultra-miniature DC to HV DC converters
that set an industry standard in high voltage miniaturization. These
component-sized converters are ideal for applications requiring mini-
mal size and weight. Occupying less than one tenth of a cubic inch
of volume*5, this unique package features an extremely low profile of
only 0.128 inches (3.25mm) when mounted in from the top, or 0.152
(3.86mm) when mounted in from the bottom of the PCB! The AG Series
converter can also mount off the PCB with .030” diameter pins. See
page 9 for illustrations. Controllable output voltages range from 100
volts to 6000 volts. Please refer to the A Series data sheet for PCB
pin mounting.
0.83 mA
0.66 mA
0.5 mA
0.32 mA
0.24 mA
0.2 mA
0.75 mA
0.5 mA
–
–
–
0.167 mA AGH60
0.25 mA
Complete List of Models on page 2
FEATURES
APPLICATIONS
• Proportional Input/Output
• Low Noise Quasi-sinewave Oscillator
• Control Pin (can be used for on/off control)
• Low Leakage Current
• Low Input/Output Capacitance
• Input to Output Galvanic Isolation
• Short Circuit Protection, 1 Minute Minimum
• No Minimum Load Required*2
• MTBF > 1,862,000 hours, per Bellcore TR 332
• Surface Mount Package
Avalanche Photodiodes
Capacitor Charging
Electrophoresis
Photomultiplier Tubes
Piezo Devices
Mass Spectrometry
Sustaining Ion Pumps
OPTIONS
• No external components required
• RoHS Compliant
1 Watt and 1.5 Watt Versions Available (AG/AGH)
Available in 3 Standard Input Voltage Ranges: 0 to 5, 12 or 24VDC (up to 3 kV)
Polarity: Choose Positive or Negative Output (P/N)
• UL Recognized
Extended Operating Temperature (AG Models / 1.0W) (T Suffix)
Alternate Input / Output Voltages (Consult Factory)
E139109
See Ordering Information (Page 12)
WWW.XPPOWER.COM
4718L06
PAGE 1
AG SERIES
ELECTRICAL SPECIFICATIONS*3
STANDARD 1 WATT - AG MODEL
1.5 WATT OPTION - AGH MODEL
OUTPUT VOLTAGE*2
MAXIMUM
OUTPUT
MAXIMUM
OUTPUT
RIPPLE
P-P*4
RIPPLE
P-P*4
(To select polarity, see pg. 12 - How to Order)
MODEL
MODEL
CURRENT*1
CURRENT*1
*7
0 to 100 VDC
0 to 200 VDC
0 to 250 VDC
0 to 300 VDC
0 to 400 VDC
0 to 500 VDC
0 to 600 VDC
0 to 700 VDC
0 to 800 VDC
0 to 900 VDC
0 to 1000 VDC
0 to 1200 VDC
0 to 1500 VDC
0 to 2000 VDC
0 to 3000 VDC
0 to 4000 VDC
0 to 5000 VDC
0 to 6000 VDC
AG01
AG02
AG025
AG03
AG04
AG05
AG06
AG07
AG08
AG09
AG10
AG12
AG15
AG20
AG30
AG40
AG50
AG60
10 mA
5 mA
5%
AGH01
AGH02
AGH025
AGH03
AGH04
AGH05
AGH06
AGH07
AGH08
AGH09
AGH10
AGH12
AGH15
AGH20
AGH30
–
15 mA
7.5 mA
6 mA
4%
3%
1%
4 mA
0.90%
0.70%
0.50%
0.50%
1%
1.2%
0.70%
0.75%
0.70%
2%
3.33 mA
2.5mA
5 mA
3.75 mA
3 mA
2 mA
1.67 mA
1.43 mA
1.25 mA
1.1 mA
1 mA
2.5 mA
2.15 mA
1.87 mA
1.67 mA
1.5 mA
1.25 mA
1 mA
0.50%
1%
1.2%
1.2%
1.2%
1%
1%
0.79%
0.50%
0.40%
0.30%
0.30%
0.30%
0.30%
0.30%
0.83 mA
0.67 mA
0.5 mA
0.33 mA
0.25 mA
0.2 mA
0.167 mA
0.60%
0.60%
0.50%
0.30%
–
0.75 mA
0.5 mA
–
–
–
–
AGH60
0.25 mA
0.30%
INPUT CURRENT
AG MODELS - 1 Watt AGH MODELS - 1.5 Watt
VIN
NO-LOAD
FULL-LOAD
NO-LOAD
FULL-LOAD
5 VDC
12 VDC
24 VDC
<200mA
<100mA
<25mA
<470mA
<185mA
<60mA
<300mA
<125mA
<40mA
<550mA
<250mA
<120mA
WWW.XPPOWER.COM
4718L06
PAGE 2
AG SERIES
ELECTRICAL SPECIFICATIONS*3
PARAMETER
VALUE
0 TO 5, 12, OR 24V (FOR MODELS UP TO 3KV)
0 TO 5V (FOR MODELS OVER 3KV)
<0.7 VDC
INPUT VOLTAGE
TURN-ON VOLTAGE
ISOLATION
< +/- 500V BIAS ON PIN 4
OUTPUT VOLTAGE TOLERANCE
INPUT/OUTPUT COUPLING CAPACITANCE
INPUT/OUTPUT LEAKAGE CURRENT
CONTROL PIN
+10%, -10% FULL LOAD, MAX. INPUT VOLTAGE
<250 pf TYPICAL
<100 nA TYPICAL
0 TO MAX INPUT VOLTAGE
50kHz - 350kHz
INTERNAL OSCILLATOR FREQUENCY
OPERATING: -25° TO +75°C*6 (CASE)
STANDARD TEMPERATURE RANGES
STORAGE: -55° TO +105°C
OPERATING: -55° TO +85°C*6 (CASE) (AG Models/1.0W)
STORAGE: -55° TO +105°C
EXTENDED TEMPERATURE RANGES (-T OPTION)
DETAILED PRODUCT DESCRIPTION
The AG Series is a new line of ultra-miniature, DC to HV DC convert-
ers that set an industry standard in high voltage miniaturization. These
component-sized converters are ideal for applications requiring minimal
size and weight. Occupying less than one tenth of a cubic inch of volume*5,
this unique package features an extremely low profile of only 0.128 inches
(3.25mm) when mounted in from the top, or 0.152 (3.86mm) when mounted
in from the bottom of the PCB! The AG Series converter can also mount off
the PCB with .030” diameter pins. See page 9 for illustrations. Controllable
output voltages range from 100 volts to 6000 volts.
Output power is 1 watt standard, with 1.5 watts available as an option. No
minimum load is required. A proprietary vacuum encapsulation process and
custom 94V-0 listed, high performance formula are used to achieve excellent
high voltage and thermal properties. Isolation is +/- 500V bias on the output
return. Input to output leakage current is very low at less than 100 nA and
coupling capacitance is also low at <250 pF.
The AG Series leverages XP EMCO’s Best-in-Class long-term reli-
ability, utilizing proven DC to high voltage DC conversion technology,
perfected by over four decades of high voltage design experience
in the most demanding applications. Our extensive in-house capabili-
ties enable us to meet specific customer requirements with standard,
modified and custom solutions quickly, easily, and economically. Technical
assistance is readily available.
Turn-on voltage is very low at less than 0.7 volts, allowing for wide output
voltage operating range. Use of a resonant, quasi-sinewave oscillator and
fully shielded transformer result in clean, reliable high voltage conversion
with inherently low ripple, EMI/RFI and input ripple current, making this
product ideal for integration into noise sensitive equipment.
A separate high impedance control pin is standard and is designed for
external error amplifier and/or DAC control in closed or open loop systems,
or simply connect the control pin to the + input for proportional input to
output operation (see performance charts below).
WWW.XPPOWER.COM
4718L06
PAGE 3
AG SERIES & AGH SERIES
MECHANICAL SPECIFICATIONS (100V - 2,000V)
TOP VIEW
RECOMMENDED
PCB LAYOUT
TOP VIEW
AG Series
BOTTOM VIEW
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
+
+
DIMENSIONAL TOLERANCES: .XX = 0.02 (0.51), .XXX = 0.005 ( 0.127)
-
-
PARAMETER
WEIGHT
VALUE
PIN #
FUNCTION
(–) INPUT
(+) INPUT
HV OUT
< 0.20 OZ. (5.66 GRAMS)
1
2
3
4
5
VOLUME
< 0.10 CUBIC INCHES (1.639 CUBIC CENTIMETERS)
0.92L (23.37L) x 0.45W (11.43W) x 0.25H (6.35H)
BODY DIMENSIONS
BODY + WING
DIMENSIONS
HV RTN
0.92L (23.37L) x 0.69W (17.53W) x 0.25H (6.35H)
CONTROL
WWW.XPPOWER.COM
4718L06
PAGE 4
AG SERIES & AGH SERIES
MECHANICAL SPECIFICATIONS (3,000V – 5,000V)
TOP VIEW
RECOMMENDED
PCB LAYOUT
TOP VIEW
AG Series
BOTTOM VIEW
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
+
+
DIMENSIONAL TOLERANCES: .XX = 0.02 (0.51), .XXX = 0.005 ( 0.127)
-
-
PARAMETER
WEIGHT
VALUE
PIN #
FUNCTION
(–) INPUT
(+) INPUT
HV OUT
0.25 OZ. (7.09 GRAMS)
1
2
3
4
5
VOLUME
<0.125 CUBIC INCHES (2.048 CUBIC CENTIMETERS)
1.13L (28.70L) x 0.45W (11.43W) x 0.25H (6.35H)
BODY DIMENSIONS
BODY + WING
DIMENSIONS
HV RTN
1.13L (28.70L) x 0.69W (17.53W) x 0.25H (6.35H)
CONTROL
WWW.XPPOWER.COM
4718L06
PAGE 5
AG SERIES & AGH SERIES
MECHANICAL SPECIFICATIONS (6,000V)
TOP VIEW
RECOMMENDED
PCB LAYOUT
TOP VIEW
AG Series
BOTTOM VIEW
DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS)
+
+
DIMENSIONAL TOLERANCES: .XX = 0.02 (0.51), .XXX = 0.005 ( 0.127)
-
-
PARAMETER
VALUE
PIN #
FUNCTION
(–) INPUT
(+) INPUT
HV OUT
WEIGHT
0.3 OZ (8.51 GRAMS)
1
2
3
4
5
VOLUME
<0.156 CUBIC INCHES (2.556 CUBIC CENTIMETERS)
1.32L (33.53L) x 0.45W (11.43W) x 0.25H (6.35H)
BODY DIMENSIONS
BODY + WING
DIMENSIONS
HV RTN
1.32L (33.53L) x 0.69W (17.53W) x 0.25H (6.35H)
CONTROL
WWW.XPPOWER.COM
4718L06
PAGE 6
AG SERIES
AG INSTALLATION
AG Mounted
on Top of PCB
AG Mounted
From Bottom
of PCB
AG Mounted Off
PCB With .030”
DIA Pins
*Height of pin can vary depending upon application
WWW.XPPOWER.COM
4718L06
PAGE 7
AG SERIES
AG RoHS REFLOW PROFILE
Reflow Results
Time Above
Liquidus
(217.0°C)
(mm:ss.tt)
Probe
Positive
Slope
(°C/sec)
Positive
Slope Time
(mm:ss.tt)
Rise Time
(120.0 - 180.0°C)
(mm:ss.tt)
Mean Slope
to Peak
(°C/sec)
Peak
Temperature
(°C)
Negative
Slope
(°C/sec)
(°C) Module Lead Top
2.62
03:43.50
01:17.00
0.77
00:44.00
237.5
-2.59
Maximum / Minimum
Probe
Maximum
(°C)
Max. Reached
(mm:ss.tt)
Mean
(°C)
Deviation from
255.0°C
Standard
deviation
Minimum
(°C)
Min. Reached
(mm:ss.tt)
(°C) Module Lead Top
237.5
04:18.00
139.8
-17.5
56.5
38.5
00:00.00
Time at Temperature
Slopes
Probe
Time Above 230.0°C
(mm:ss.tt)
Time to Reach 230.0°C
(mm:ss.tt)
Positive Slope
(°C/sec)
Mean Slope
(°C/sec)
(°C) Module Lead Top
00:16.00
04:09.50
2.62
0.38
*Reflow profile is subject to change based on your application
WWW.XPPOWER.COM
4718L06
PAGE 8
AG SERIES
APPLICATION NOTES
Typical HV Output vs. Control Voltage
300
250
200
150
100
50
Full Load Output
No Load Output (AG)
No Load Output (AGH)
Safe Operating Limit
0
0
10
20
30
40
50
60
70
80
90
100
% Control Voltage
NOTE: Vin held at maximum
TYPICAL INPUT vs. OUTPUT VOLTAGE
100
90
80
70
60
50
40
30
20
10
0
loaded
unloaded (AG)
unloaded (AGH)
0
10
20
30
40
50
60
70
80
90
100
% INPUT VOLTAGE
NOTE: Control Pin tied to Vin Pin
Output Voltage is load dependent. Under light or no-load conditions, reduce
the Input Voltage so maximum rated Output Voltage is not exceeded.
WWW.XPPOWER.COM
4718L06
PAGE 9
AG SERIES
OPTION CODES
ORDERING INFORMATION
ORDER CODE
AVAILABILITY
1 WATT
AG
AGH
P
ALL
ALL
OUTPUT VOLTAGE
1.5 WATT
POSITIVE OUTPUT
NEGATIVE OUTPUT
5 VDC
ALL
POLARITY DESIGNATOR
N
ALL
5
ALL/Except AGH01 Model
UP TO 3KV
UP TO 3KV
AG MODELS/1W
INPUT VOLTAGE
OPTIONS
12 VDC
12
24
T
24 VDC
EXTENDED TEMP
HOW TO ORDER
PART NUMBER SELECTOR:
Model Number:
AG 20 ꢁ ꢀ 12 ꢂ
ꢂ ꢀ Extended Operating Temperature
12 ꢀ Input Voltage
ꢁ ꢀ Polarity Designator
AG ꢀ Model
20 ꢀ Output Voltage/100 (See table)
EXAMPLE: AG20ꢁꢀ12ꢂ (AG - Model, 20 - Output Voltage, ꢁ - Negative, 12 - Input Voltage, ꢂ ꢀ Extended Operating Temperature)
*Note:
1. At maximum rated output voltage.
2. Output Voltage is load dependent. Under light or no-load conditions, reduce the Input Voltage so maximum rated Output Voltage is not exceeded.
3. Specifications after 30 minute warm-up, full-load, at 25ºC, unless otherwise noted.
4. Ripple may be reduced substantially by the addition of an external RC filter.
5. Volume will vary depending on package size.
6. Proper thermal management techniques are required to maintain safe case temperature at maximum power output.
7. The AGH01 is only available in 12V or 24V.
XP EMCO reserves the right to make changes on products and literature, including specifications, without notice. XP EMCO standard product models are not recommended for “copy-exact” applications or any other application restricting product
changes. “Copy-exact” options are available. Please contact an XP EMCO sales representative for more details.
WWW.XPPOWER.COM