DNR05US05-S [XPPOWER]

AC-DC Regulated Power Supply Module, 5W;
DNR05US05-S
型号: DNR05US05-S
厂家: XP POWER LIMITED    XP POWER LIMITED
描述:

AC-DC Regulated Power Supply Module, 5W

文件: 总4页 (文件大小:177K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
5ꢀ60 Watts  
DNR Series  
xppower.com  
Rugged Design for Industrial Applications  
Up to 89% Efficiency  
Full Power to +60 °C  
Wide Adjustment Range  
DC OK 24 V Models  
DC Standby Versions  
3 Year Warranty  
Specification  
Input  
General  
Input Voltage  
• 90-264 VAC, 120-375 VDC (DNR05/10/18)  
Efficiency  
Isolation  
• See tables  
• 3000 VAC Input to Output, 1500 VAC Input  
to Ground, 500 VAC Output to Ground  
85-264 VAC, 90-375 VDC (DNR30/60)  
• 47-63 Hz  
Input Frequency  
Input Current  
Inrush Current  
• See tables  
Switching Frequency  
Signals  
• 132 KHz typical, 55-90 kHz (DNR60)  
• 5-18 W: 10/18 A at 115/230 VAC  
30 W: 20/40 A at 115/230 VAC  
60 W: 30/60 A at 115/230 VAC  
• DC ON indicator LED Green: All models  
DC LOW indicator LED Red: 5-18 W models  
DC OK: 24 V 30-60 W models  
DC OK: All standby models  
Power Factor  
Earth Leakage Current • 0.8 mA max  
Input Protection  
• EN61000-3-2, class A  
MTBF  
• 800 kHrs typical Bellcore, Issue 6 at +40 °C,  
GB (DNR05/10/18), 530 kHrs typical  
• Internal fuse T2A, 250 VAC fitted in line  
Bellcore, Issue 6 at +40 °C, GB (DNR30/60)  
DIN Rail  
• Compatible with TS35/7.5 or TS35/15  
Output  
Output Voltage  
• See tables  
• See tables  
Environmental  
Operating Temperature • -20 °C to +70 °C (DNR05/10/18)  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
1ꢀ  
-40 °C to +70 °C, start up at -35 °C  
• No minimum load required  
• <1 s (may increase at low  
temperature extremes)  
(DNR30/60), all units derate linearly from  
60 °C (see derating curves)  
Start Up Delay  
Cooling  
• Convection-cooled with 25mm free space  
all sides  
• 20-95ꢀ RH, non-condensing  
Start Up Rise Time  
Hold Up Time  
• <150 ms  
• 30/130 ms at 115/230 VAC (DNR05)  
25/100 ms at 115/230 VAC (DNR10)  
20/75 ms at 115/230 VAC (DNR18)  
20/30 ms at 115/230 VAC (DNR30)  
20/30 ms at 115/230 VAC DNR60)  
• 5-18 W: 1.0ꢀ max  
30-60 W: 0.5ꢀ max  
• 5-18 W: 2.0ꢀ max  
30-60 W: 0.5ꢀ max  
• Redundancy module DPM10 available  
for load currents up to 10 A (not with  
standby system), contact sales  
• 4ꢀ max deviation recovery to within  
1ꢀ in 2 ms for a 50ꢀ load change  
Operating Humidity  
Storage Temperature • -25 °C to +85 °C (DNR05/10/18)  
-40 °C to +85 °C (DNR30/60)  
• 15 g, 11 ms, X, Y & Z axis, 3 shocks/axis  
in both directions  
• 2 g, 10 Hz to 500 Hz, along X, Y & Z axis,  
60 mins/axis, mounted on rail  
Shock  
Line Regulation  
Load Regulation  
Parallel Operation  
Vibration  
EMC & Safety  
Emissions  
Harmonic Currents  
Voltage Flicker  
ESD Immunity  
Radiated Immunity  
EFT/Burst  
• EN55022, level B conducted & radiated  
• EN61000-3-2, class A  
• EN61000-3-3  
• EN61000-4-2, level 4, Perf Criteria A  
• EN61000-4-3, level 3, Perf Criteria A  
• EN61000-4-4, level 4, Perf Criteria A  
Transient Response  
Ripple & Noise  
• 50 mV pk-pk, 20 MHz bandwidth (may  
increase at low temperature extremes)  
Overvoltage Protection • Output clamps at 120-145ꢀ Vnom,  
auto recovery  
• 110-145ꢀ constant current (DNR05-18)  
105-150ꢀ power limited (DNR30/60)  
Surge  
• EN61000-4-5, installation class 3,  
Perf Criteria A  
Overload Protection  
Conducted Immunity  
Magnetic Field  
Dips & Interruptions  
• EN61000-4-6, level 3, Perf Criteria A  
• EN61000-4-8, level 4 Perf Criteria A  
• EN61000-4-11, 30ꢀ 10 ms,  
60ꢀ 100 ms, 100ꢀ 5000 ms  
Perf Criteria A, B, B  
Short Circuit Protection • Power limited, auto recovery  
Temperature  
Coefficient  
0.03ꢀ/°C  
Safety Approvals  
• EN60950-1, UL508 Pollution Degree 2,  
UL1310 class 2 power recognised,  
See note 3 & ratings table,  
UL60950-1 Overvoltage Category II,  
UL508 Overvoltage Category III,  
DNR30 & DNR60: SEMI F47  
ANSI/ISA 12.12.01. Class 1, Division 2  
Groups A,B,C and D  
DNR05ꢀ60  
Models and Ratings  
Input Current (typ.)  
Output  
Output  
Voltage Trim  
Output Current Efficiency (typ.)  
Model Number  
115 VAC  
0.12 A  
0.12 A  
0.12 A  
0.12 A  
0.20 A  
0.20 A  
0.20 A  
0.20 A  
0.36 A  
0.36 A  
0.36 A  
0.36 A  
0.56 A  
0.56 A  
0.56 A  
0.56 A  
1.10 A  
1.10 A  
1.10 A  
1.10 A  
230 VAC  
0.08 A  
0.08 A  
0.08 A  
0.08 A  
0.13 A  
0.13 A  
0.13 A  
0.13 A  
0.21 A  
0.21 A  
0.21 A  
0.21 A  
0.33 A  
0.33 A  
0.33 A  
0.33 A  
0.59 A  
0.59 A  
0.59 A  
0.59 A  
Voltage  
(1)  
5 V  
12 V  
15 V  
24 V  
5 V  
4.50-5.75 V  
10.80-13.80 V  
13.50-17.25 V  
21.60-28.80 V  
4.50-5.75 V  
1.000 A  
0.420 A  
0.340 A  
0.210 A  
2.000 A  
0.840 A  
0.670 A  
0.420 A  
3.000 A  
1.500 A  
1.200 A  
0.750 A  
6.000 A  
2.500 A  
1.250 A  
0.625 A  
10.000 A  
5.000 A  
2.500 A  
1.250 A  
69ꢀ  
72ꢀ  
72ꢀ  
72ꢀ  
73ꢀ  
75ꢀ  
76ꢀ  
76ꢀ  
75ꢀ  
77ꢀ  
77ꢀ  
77ꢀ  
79ꢀ  
84ꢀ  
86ꢀ  
86ꢀ  
79ꢀ  
86ꢀ  
89ꢀ  
89ꢀ  
DNR05US05  
(1)  
DNR05US12  
(1)  
DNR05US15  
(1)  
DNR05US24  
(1)  
DNR10US05  
(1)  
12 V  
15 V  
24 V  
5 V  
10.80-13.80 V  
13.50-17.25 V  
21.60-28.80 V  
4.50-5.75 V  
DNR10US12  
(1)  
DNR10US15  
(1)  
DNR10US24  
(1)  
DNR18US05  
(1)  
12 V  
15 V  
24 V  
5 V  
10.80-13.80 V  
13.50-17.25 V  
21.60-28.80 V  
5.00-5.50 V  
DNR18US12  
(1)  
DNR18US15  
(1)  
DNR18US24  
(1,3,4)  
DNR30US05  
(1,3,4)  
12 V  
24 V  
48 V  
5 V  
12.00-14.00 V  
24.00-28.00 V  
48.00-55.00 V  
5.00-5.50 V  
DNR30US12  
(1,3,4)  
DNR30US24  
(1,3,4)  
DNR30US48  
(1,3,4)  
DNR60US05  
(1,3,4)  
12 V  
24 V  
48 V  
12.00-14.00 V  
24.00-28.00 V  
48.00-55.00 V  
DNR60US12  
(1,3,4)  
DNR60US24  
(1,3,4)  
DNR60US48  
Notes  
1. Add suffix ‘-S’ for spring clamp connection option.  
2. 30-60 W models are suitable for battery-charging applications.  
3. Approved to UL1310, but 5 & 12 V not Class 2 Power recognised.  
4. SEMI F47 compliant.  
Derating Curves  
100  
DNR05ꢀ18 W Models  
80  
60  
40  
20  
0
20  
30  
40  
-20  
0
10  
50  
60  
70  
DNR30ꢀ60 W Models  
100  
80  
60  
40  
20  
0
20  
30  
Ambient Temp (˚C)  
40  
-40  
0
10  
50  
60  
70  
DNR05ꢀ60  
Mechanical Details  
DNR05/10/18 W Models  
0.89  
(22.5)  
4.53 (115.0)  
2
1
-V  
+V  
DC  
Output  
DC LO  
ON  
3.48  
(88.5)  
Voltage  
Trim  
N
L
3
1
AC Input  
DNR05, 10, 18 Connections  
Designation  
Ground  
Neutral  
Line  
Positive  
Negative  
Conn Pin  
1
AC  
2
Notes  
Input  
3
1. All dimensions in inches (mm).  
2. Weight 0.33 lb (150 g) approx.  
3. Tolerance: 0.02 (0.5) maximum.  
4. Connection screw maximum torque:  
DC  
Output  
1
2
Input: 9 lbs-in (1.0 Nm), Output: 5.5 lbs-in (0.6 Nm)  
30/60 W Models  
1.59  
(40.5)  
4.53 (115.0)  
5
1
-V -V +V +V DC  
OK  
DC Output  
Voltage  
Trim  
3.60  
(90.0)  
ON  
N
L
1
3
DNR30/60 Connections  
Designation  
Ground  
Neutral  
AC Input  
Conn Pin  
1
AC  
2
Input  
3
Line  
1
2
DC OK*  
Positive  
Positive  
Negative  
Negative  
DC  
3
Output  
4
Notes  
1. All dimensions in inches (mm).  
2. Weight 0.8 lb (350 g) approx.  
4. Connection screw maximum torque:  
5
Input: 9 lbs-in (1.0 Nm), Output: 5.5 lbs-in (0.6 Nm)  
3. Tolerance: 0.02 (0.5) maximum.  
* 24 V and standby models only.  
DNR05ꢀ60  
Standby Versions  
5
1
Maximum current drain from battery by PSU when inactive 22 mA  
-V -V +V +V DC  
OK  
+V  
+V  
DNR30/60 Connections  
DC Output  
Conn  
Pin  
1
2
Designation  
Ground  
Neutral  
DC OK  
AC Input  
Voltage  
Trim  
3
Line  
D1  
1
DC OK  
e.g. IN4001  
2
3
4
5
Positive  
Positive  
Negative  
Negative  
LOAD  
DC Output  
ON  
Fuse  
Notes  
1. With AC in, unit provides power to the load and to charge the  
battery. The DC OK signal acts by sensing a voltage on +V and  
holds the relay closed.  
2. With loss of AC in, battery voltage is present on +V. DC OK  
signal holds the relay closed. Battery supplies power to the load.  
3. As the battery discharges, its voltage falls. When this falls below  
the level shown in the table below the DC OK signal switches off  
to allow the relay to open to disconnect and protect the battery.  
Lead  
Acid  
Battery  
-V  
-V  
N
L
1
3
DNR30/60 connection for DC  
standby system applications  
AC Input  
Output Set Voltages For Standby Versions  
Model(1)  
Voltage  
13.6 V  
27.2 V  
54.5 V  
13.6 V  
27.2 V  
54.5 V  
Current  
2.20 A  
1.10 A  
0.55 A  
4.40 A  
2.20 A  
1.10 A  
DC OK Signal Off  
Efficiency  
84ꢀ  
DNR30US12#  
DNR30US24#  
DNR30US48#  
DNR60US12#(2)  
DNR60US24#  
DNR60US48#  
10.30-11.30 V  
21.10-22.10 V  
42.70-43.70 V  
10.30-11.30 V  
21.10-22.10 V  
42.70-43.70 V  
86ꢀ  
86ꢀ  
86ꢀ  
89ꢀ  
89ꢀ  
Notes  
1. Suffix # indicates standby version.  
2. Not UL1310 approved.  
DC OK  
30/60 W Models  
Output good = 24 V Output not good = 0 V  
RL > 700Ω  
N/O  
N/C  
DCOK  
-Vout  
DCOK  
22 K  
0.5 W  
5.1 V  
0.3 W  
-Vout  
Common  
Example using external components  
to create TTL signal  
Example using external relay  
to create volt-free contact  
Standard on 24 V models, 30-60 W only.  
21-Jan-11  

相关型号:

DNR05US12

AC-DC Power Supplies
XPPOWER

DNR05US12-S

AC-DC Regulated Power Supply Module, 5W
XPPOWER

DNR05US15

AC-DC Power Supplies
XPPOWER

DNR05US24

AC-DC Power Supplies
XPPOWER

DNR10US05

AC-DC Power Supplies
XPPOWER

DNR10US05-S

AC-DC Regulated Power Supply Module, 10W,
XPPOWER

DNR10US12

AC-DC Power Supplies
XPPOWER

DNR10US12-S

AC-DC Regulated Power Supply Module, 10W
XPPOWER

DNR10US15

AC-DC Power Supplies
XPPOWER

DNR10US15-S

AC-DC Regulated Power Supply Module, 10W
XPPOWER

DNR10US24

AC-DC Power Supplies
XPPOWER

DNR10US24-S

AC-DC Regulated Power Supply Module, 10W