ECF40US36 [XPPOWER]

AC-DC Power Supplies;
ECF40US36
型号: ECF40US36
厂家: XP POWER LIMITED    XP POWER LIMITED
描述:

AC-DC Power Supplies

文件: 总5页 (文件大小:937K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
AC-DC Power Supplies  
ECF40 Series  
40 Watts  
• 40 W Convection Rating  
• 1.5” by 3” Footprint  
• Low 1.1” Profile  
• High Efficiency  
• Medical and ITE Approvals  
• Class I & Class II Installations  
• High Power Density  
• Less than 0.15 W No Load Input Power  
• 3 Year Warranty  
Dimensions:  
The ECF40 series is designed to minimize the no load power consumption and maximize efficiency  
to facilitate equipment design to meet the latest environmental legislation. Approved for medical and  
ITE applications in either Class I or Class II installations, this range of single output AC-DC power supplies  
are packaged in a low profile 1.1” height with a foot print of just 1.5” by 3”. The ECF40 provides up to  
40W convection-cooled over the full 90-264 VAC input range, and operates down to 80 VAC with minimal  
ECF40:  
3.00 x 1.50 x 1.10” (76.2 x 38.1 x 28.0 mm)  
de-rating. The power supply features two AC line fuses and low leakage currents required by medical applications. The low profile, low noise and safety  
approvals covering ITE and medical standards allows the versatile ECF40 series to be used in a wide range of applications.  
Models & Ratings  
Output Power  
40 W  
Output Voltage  
12.0 V  
Output Current  
3.34 A  
Efficiency(1)  
91%  
Model Number  
ECF40US12  
ECF40US15  
ECF40US18  
ECF40US24  
ECF40US36  
ECF40US48  
40 W  
40 W  
40 W  
40 W  
15.0 V  
18.0 V  
24.0 V  
36.0 V  
2.67 A  
2.23 A  
1.67 A  
1.11 A  
92%  
93%  
91%  
90%  
40 W  
48.0 V  
0.83 A  
90%  
Notes  
1. Typical efficiency measured at full load and 230 VAC input.  
Mechanical Details  
Output Voltage Control  
CN1 - Input Connector  
Ø0.14 (3.6) through in 4 positions  
3.00 (76.2)  
Pin 1  
Pin 2  
Pin 3  
Neutral  
Not Fitted  
Line  
-VE  
+VE  
Output  
Terminals  
Mates with JST housing VHR-3N and JST  
Series SVH-21T-P1.1 crimp terminals  
Line  
Neutral  
Mounting hole marked with  
must be  
connected to safety earth for class I  
applications  
0.13  
0.13  
2.75 (69.85)  
(3.18)  
(3.18)  
CN2 - Output Connector  
Pin 1  
Pin 2  
+Vout  
-Vout  
1.11  
(28.14)  
Mates with JST housing VHR-2N and JST  
Series SVH-21T-P1.1 crimp terminals  
Notes  
1. All dimensions shown in inches (mm).  
Tolerance: 0.02 (0.5)  
2. Weight: 0.15 lbs (69 g) approx.  
www.xppower.com  
1
AC-DC Power Supplies  
ECF40 Series  
Summary  
Characteristic  
Minimum  
Typical  
Maximum  
264  
Units  
Notes & Conditions  
Derate output from 100% at 90 VAC to 90% at 85 VAC and  
80% at 80 VAC  
Input Range  
80  
115/230  
VAC  
No Load Input Power  
Efficiency  
0.15  
W
%
°C  
90  
230 VAC (see fig.1 & 2)  
Operating Temperature  
-25  
+70  
See derating curve (fig.3)  
ITE  
IEC60950, UL60950-1, CSA 22.2 No.60950-1-11 Ed 2, EN60950-1, LVD  
IEC60601-1 Ed 3.1 Including Risk Management, ANSI/AAMI ES60601-1 & CSA C22.2 No.6061-1:08, EN60601-1  
Safety Approvals  
Medical  
Input  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
Notes & Conditions  
Derate output from 100% at 90 VAC to 90% at 85 VAC and  
80% at 80 VAC  
Input Voltage - Operating  
80  
47  
115/230  
50/60  
264  
63  
VAC  
Hz  
Input Frequency  
Agency approval, 47-63 Hz  
EN61000-3-2 class A  
115/230 VAC  
Power Factor  
Input Current - Full Load  
Inrush Current  
0.8/0.4  
A
A
60  
264 VAC cold start, 25 ºC  
Earth Leakage Current  
No load Input Power  
Input Protection  
250  
0.15  
µA  
W
264 VAC/60 Hz  
T3.15 A/250 A, 250 V Internal fuse fitted in line and neutral.  
Output - Main Output  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
VDC  
%
Notes & Conditions  
Output Voltage  
12  
48  
1
See Models and Ratings table  
50% load, 115/230 VAC  
Initial Set Accuracy  
Output Voltage Adjustment  
Minimum Load  
10  
0
%
A
No minimum load required  
Start Up Delay  
1
2
s
Output Rise Time  
Hold Up Time  
50  
ms  
ms  
%
8.3/20  
Min at full load 115/230 VAC  
90-264 VAC  
Line Regulation  
Load Regulation  
0.5  
1
%
0-100% load.  
Recovery within 1% in less than 500 µs  
for a 50-75% and 75-50% load step  
Transient Response  
Over/Undershoot  
4
5
%
%
Full load  
Ripple & Noise  
3/2  
140  
160  
% pk-pk  
%
12 V/15-48 V models  
Overvoltage Protection  
Overload Protection  
Short Circuit Protection  
Temperature Coefficient  
115  
110  
Vnom, recycle input to reset  
% I nom  
Continuous trip and restart (hiccup)  
0.05  
%/˚C  
General  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
Notes & Conditions  
Average active mode efficiency at 25%, 50%, 75% and  
100% load  
Efficiency  
90  
%
4000  
1500  
500  
VAC  
VAC  
VAC  
2 MOPP  
Isolation: Input to Output  
Input to Ground  
1 MOPP  
Output to Ground  
1 MOPP at output voltage  
3
Power Density  
8.1  
W/in  
Mean Time Between Failure  
Weight  
500  
kHrs  
lb(g)  
MIL-HDBK-217F, Notice 2 +25 °C GB  
0.15 (69.0)  
www.xppower.com  
2
AC-DC Power Supplies  
ECF40 Series  
Efficiency Vs Load  
Figure 1  
ECF40PS12  
100  
95  
90  
85  
80  
75  
70  
115VAC  
230VAC  
25  
50  
75  
100  
Load (%)  
Figure 2  
ECF40PS24  
100  
95  
90  
85  
80  
75  
70  
115VAC  
230VAC  
25  
50  
75  
100  
Load (%)  
Environmental  
Characteristic  
Operating Temperature  
Storage Temperature  
Humidity  
Minimum  
Typical  
Maximum  
Units  
°C  
Notes & Conditions  
-25  
-40  
5
+70  
+85  
95  
See derating curve, fig.3  
°C  
%RH  
m
Non-condensing  
ITE/Medical  
Operating Altitude  
Shock  
5000/4000  
3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/- 0.5msecs), half sine. Conforms to EN60068-2-27  
Single axis 10-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6  
Vibration  
www.xppower.com  
3
AC-DC Power Supplies  
ECF40 Series  
Temperature Derating Curve  
Figure 3  
100  
50  
0
-25 -20  
0
+50  
+70  
Ambient Temperature (ºC)  
EMC: Emissions  
Phenomenon  
Standard  
Test Level  
Class B  
Class A  
Class A  
Criteria  
Notes & Conditions  
Conducted  
EN55011/22  
EN55011/22  
EN61000-3-2  
EN61000-3-3  
Radiated  
Harmonic Current  
Voltage Functions  
EMC: Immunity  
Phenomenon  
Medical Device EMC  
Low Voltage PSU EMC  
ESD  
Standard  
Test Level  
Criteria  
Notes & Conditions  
IEC60601-1-2  
EN61204-3  
Ed.4.0 : 2014  
as below  
High severity level  
as below  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
8kV contact, 15kV air  
3
A
A
A
A
A
A
A
B
B
B
B
B
A
B
B
B
B
B
A
B
B
B
B
B
A
A
A
A
B
A
A
A
A
B
Radiated  
EFT  
3
Surge  
Installation class 3  
Conducted  
Magnetic Fields  
3
4
Dip 100% (0 VAC), 8.4 ms  
Dip 100% (0 VAC), 16.7 ms  
Dip 60% (40 VAC), 200 ms  
Dip 30% (70 VAC), 500 ms  
Dip 20% (80 VAC), 5000 ms  
Int 100% (0 VAC), 5000 ms  
Dip 100% (0 VAC), 8.4 ms  
Dip 100% (0 VAC), 16.7 ms  
Dip 60% (40 VAC), 200 ms  
Dip 30% (70 VAC), 500 ms  
Dip 20% (80 VAC), 5000 ms  
Int 100% (0 VAC), 5000 ms  
Dip 100% (0 VAC), 10 ms  
Dip 100% (0 VAC), 20 ms  
Dip 60% (96 VAC), 200 ms  
Dip 30% (168 VAC), 500 ms  
Dip 20% (192 VAC), 5000 ms  
Int 100% (0 VAC), 5000 ms  
Dip 100% (0 VAC), 10 ms  
Dip 100% (0 VAC), 20 ms  
Dip 60% (40 VAC), 100 ms  
Dip 30% (70 VAC), 500 ms  
Int 100% (0 VAC), 5000 ms  
Dip 100% (0 VAC), 10 ms  
Dip 100% (0 VAC), 20 ms  
Dip 60% (96 VAC), 100 ms  
Dip 30% (168 VAC), 500 ms  
Int 100% (0 VAC), 5000 ms  
25% derating  
EN61000-4-11 (100 VAC)  
EN61000-4-11 (115 VAC)  
EN61000-4-11 (240 VAC)  
Dips and Interruptions  
30% derating  
60% derating  
75% derating  
EN60601-1-2 (100 VAC)  
EN60601-1-2 (420 VAC)  
www.xppower.com  
4
AC-DC Power Supplies  
ECF40 Series  
Safety Approvals  
Safety Agency  
Safety Standard  
Notes & Conditions  
CB Report  
UL  
IEC60950-1:2005  
Information Technology  
Information Technology  
Information Technology  
UL60950-1, CSA 22.2 No.60950-1-11 Ed 2  
TUV  
EN60950-1  
LVD  
CE  
Safety Agency  
Safety Standard  
Notes & Conditions  
Medical  
CB Report  
IEC60601-1 Ed 3.1 Including Risk Management  
ANSI/AAMI ES60601-1: & CSA C22.2 No.6061-1:08  
EN60601-1  
UL  
CE  
Medical  
Medical  
Isolation  
Safety Standard  
Notes & Conditions  
Primary to Secondary  
Primary to Earth  
Secondary to Earth  
2 x MOPP (Means of Patient Protection)  
1 x MOPP (Means of Patient Protection)  
IEC60601-1 Ed 3.1  
1 x MOPP (Means of Patient Protection) at output voltage  
Mechanical Details  
Output Voltage Control  
Ø0.14 (3.6) through in 4 positions  
3.00 (76.2)  
-VE  
+VE  
Output  
Terminals  
Line  
Neutral  
0.13  
0.13  
2.75 (69.85)  
(3.18)  
(3.18)  
1.11  
(28.14)  
CN1 - Input Connector  
CN2 - Output Connector  
Pin 1  
Pin 2  
Pin 3  
Neutral  
Not Fitted  
Line  
Pin 1  
Pin 2  
+Vout  
-Vout  
Mates with JST housing VHR-2N and  
JST Series SVH-21T-P1.1 crimp terminals  
Mates with JST housing VHR-3N and JST  
Series SVH-21T-P1.1 crimp terminals  
Mounting hole marked with  
must be  
connected to safety earth for class I  
applications  
Notes  
1. All dimensions shown in inches (mm).  
Tolerance: 0.02 (0.5)  
2. Weight: 0.14 lbs (66 g) approx.  
www.xppower.com  
5
31 Aug 17  

相关型号:

ECF40US48

AC-DC Power Supplies
XPPOWER

ECF40_17

AC-DC Power Supplies
XPPOWER

ECF45

Surface Mount Crystal Filters
ECM

ECF80

TRIODE-PENTODE
NXP

ECF82

STEILE TRIODE PENTODE
ETC

ECFF1E102KB

Ceramic Capacitor, Ceramic, 25V, Y5P, -/+10ppm/Cel TC, 0.001uF
PANASONIC

ECFF1E122KB

Ceramic Capacitor, Ceramic, 25V, 10% +Tol, 10% -Tol, Y5P, -/+10ppm/Cel TC, 0.0012uF,
PANASONIC

ECFF1E223MR2

Ceramic Capacitor, Ceramic, 25V, 20% +Tol, 20% -Tol, Y5R, -/+15ppm/Cel TC, 0.022uF,
PANASONIC

ECFF1E272KB

Ceramic Capacitor, Ceramic, 25V, 10% +Tol, 10% -Tol, Y5P, -/+10ppm/Cel TC, 0.0027uF,
PANASONIC

ECFF1E472KB

Ceramic Capacitor, Ceramic, 25V, 10% +Tol, 10% -Tol, Y5P, -/+10ppm/Cel TC, 0.0047uF,
PANASONIC

ECFF1H103KB

Ceramic Capacitor, Ceramic, 50V, Y5P, -/+10ppm/Cel TC, 0.01uF
PANASONIC

ECFF1H103MR

Ceramic Capacitor, Ceramic, 50V, Y5R, -/+15ppm/Cel TC, 0.01uF
PANASONIC