ECS130US24-C [XPPOWER]

AC-DC Regulated Power Supply Module, 130W;
ECS130US24-C
型号: ECS130US24-C
厂家: XP POWER LIMITED    XP POWER LIMITED
描述:

AC-DC Regulated Power Supply Module, 130W

输出元件
文件: 总5页 (文件大小:667K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
65/100/130 Watts  
ECS Series  
xppower.com  
IT & Medical Safety Approvals  
65/80/100 W ꢀ Convectionꢀcooled Ratings  
Class I & Class II Construction  
Industry Standard 2” x 4” Package  
<0.5 W No Load Input Power  
Low Leakage Current  
3 Year Warranty  
Specification  
Input  
General  
Input Voltage  
• 80-264 VAC (275 VAC ECS65)  
(120-370 VDC), derate output power  
<90 VAC, see derating curves  
Efficiency  
Isolation  
• Up to 90% model dependent  
• 4000 VAC Input to Output, 2 x MOPP,  
1500 VAC Input to Ground, 1 x MOPP,  
500 VDC Output to Ground, 1 x MOPP  
(1)  
Input Frequency  
Input Current  
• 47-400 Hz  
• 65 W: 1.0/0.6 A typical at 115/230 VAC  
100 W: 1.5/0.9 A typical at 115/230 VAC,  
130 W: 1.9/1.1 A typical at 115/230 VAC  
full load  
• 40 A max at 230 VAC, cold start at 25 ˚C  
• EN61000-3-2, class A  
Switching Frequency  
Power Density  
• 65 KHz typical  
• 65 W: 7.7 W/in , 100 W: 10 W/in ,  
130 W: 13 W/in  
3
3
3
MTBF  
• 65 W: 850 kHrs, 100 W: 834 kHrs,  
130 W: 715 kHrs to MIL-HDBK-217F  
at 25 ˚C, GB  
Inrush Current  
Power Factor  
No Load Input Power • <0.5 W  
Environmental  
Operating Temperature • -20 ˚C (-40 ˚C, ECS130) to +70 ˚C derate  
linearly from +50 ˚C at 2.5%/˚C to 50%  
load at +70 ˚C.  
Cooling  
Operating Humidity  
Storage Temperature • -40 ˚C to +85 ˚C  
Operating Altitude  
Shock  
Earth Leakage Current • 65/130 W: 260 µA at 264 VAC/60 Hz max  
100 W: 230 µA at 264 VAC/60 Hz max  
Input Protection  
• Internal T3.15/T5 A/250 V fuse in line and  
neutral  
• Convection & fan cooled ratings (see tables)  
• 95% RH, non-condensing  
Output  
Output Voltage  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
Start Up Delay  
Start Up Rise Time  
Hold Up Time  
• 12-48 VDC (see tables)  
• 3000 m  
• 30 g pk, half sine, 6 axes  
• 2 g rms, 5 Hz to 500 Hz, 3 axes  
10%  
1%  
Vibration  
• No minimum load required  
• 1 s typical  
• 50 ms  
EMC & Safety  
Low Voltage PSU EMC • EN61204-3, high severity level  
Emissions  
• 16 ms min at 115 VAC  
• EN55011/22 level B conducted  
EN55011/22 level A radiated, level B  
Suffix ‘-B’ models  
• EN61000-3-2, class A  
• EN61000-3-3  
• EN61000-4-3, level 3 Perf Criteria A  
• EN61000-4-4, level 3 Perf Criteria A  
• EN61000-4-5, installation class 3  
Perf Criteria A  
Drift  
0.2% after 20 min warm up  
0.5% max  
1%  
Line Regulation  
Load Regulation  
Over/Undershoot  
Transient Response  
Harmonic Currents  
Voltage Flicker  
Radiated Immunity  
EFT/Burst  
• 5% typical  
• 4% max. deviation, recovery to within  
1% in 500 µs for a 50-75-50% load  
change  
Surge  
Ripple & Noise  
• 1% pk-pk, 20 MHz bandwidth  
Overvoltage Protection • 115-140% Vnom, recycle input to reset  
Overload Protection • 110-160%  
Short Circuit Protection • Continuous trip and restart (hiccup mode)  
Conducted Immunity  
Dips & Interruptions  
• EN61000-4-6, level 3 Perf Criteria A  
• EN61000-4-11, 30% 10 ms, 60% 100 ms,  
100% 5000 ms, Perf Criteria A, B, B,  
EN60601-1-2, 30% 500 ms, 60% 100 ms,  
100% 10 ms, 100% 5000 ms, Perf Criteria  
A, A, A, B - 230 VAC. Consult longform  
datasheet for 115 V operation.  
Temperature  
Coefficient  
• 0.05%/˚C  
Safety Approvals  
• IEC60950-1 CB report, CSA 22.2  
No. 60950-1, UL60950-1, TUV EN60950-1  
IEC60601-1 CB report, CSA 22.2  
No. 60601-1, ANSI/AMMI ES60601-1,  
TUV 60601-1, including risk management  
Equipment Protection • Class I & II (ECS65 Non ‘-B’ models,  
Class Class I only)  
Notes  
1. Safety approvals cover frequency 47-63 Hz.  
ECS65  
Models and Ratings  
Output Power  
Output Voltage  
Output Current  
Model Number(1)  
65 W  
65 W  
65 W  
65 W  
65 W  
65 W  
12.0 VDC  
15.0 VDC  
18.5 VDC  
24.0 VDC  
28.0 VDC  
48.0 VDC  
5.4 A  
4.3 A  
3.4 A  
2.7 A  
2.3 A  
1.4 A  
ECS65US12  
ECS65US15  
ECS65US18  
ECS65US24  
ECS65US28  
ECS65US48  
Notes  
1. For Class B radiated emissions models, add suffix -B to model number. For covered versions, add suffix ‘-C’ to model number or order part no. ECM40/60 COVER  
KIT for standalone cover. Derate output power by 20% with cover. The cover is not suitable for Class II installations.  
Mechanical Details  
4.00 (101.6)  
3.750 (95.25)  
1.05  
(26.7)  
0.125 (3.17)  
C4  
1
2.00 (50.8)  
1.75 (44.45)  
2
1
C5  
J1  
T1  
1
4
J2  
0.95 (24.1)  
0.96 (24.5)  
0.25 Faston Ground Tab  
0.125 (3.18)  
0.20 (5.1)  
Q1  
0.14 (3.5)  
SMD Component Height  
0.20 (5.1)  
4 X ø.156 (3.96) Mounting Holes  
ø.312 (7.92) Clearance top and bottom  
Input Connector J1  
Molex PN 09-65-2038  
Output Connector J2  
Molex PN 09-65-2048  
Pin 1  
Pin 2  
0.25” Faston  
Line  
Neutral  
Earth  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
+V1  
+V1  
RTN  
RTN  
J1 mates with Molex Housing PN 09-50-1031, J2 mates with  
Molex Housing PN 09-50-1041 and both with Molex Series 5194  
Crimp Terminals  
Notes  
1. All dimensions in inches (mm).  
2. Weight: 0.386 lbs (175 g)  
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)  
Derating Curve ꢀ ECS65 Models  
Some Specification Parameters  
may not be met  
100  
90  
100  
90  
Open Frame  
With Cover  
80  
80  
70  
60  
50  
40  
70  
60  
50  
40  
30  
80  
85  
90  
275  
70  
40  
50  
60  
Input Voltage (VAC)  
Ambient Temperature (ºC)  
ECS100  
Models and Ratings  
Output Power  
Output Voltage  
Output Current  
Model Number(1)  
Forced Cooled (10 CFM)  
Convection-cooled  
100 W  
100 W  
100 W  
100 W  
100 W  
100 W  
80 W  
80 W  
80 W  
80 W  
80 W  
80 W  
12.0 VDC  
15.0 VDC  
18.0 VDC  
24.0 VDC  
28.0 VDC  
48.0 VDC  
8.3 A  
6.7 A  
5.5 A  
4.2 A  
3.6 A  
2.1 A  
ECS100US12  
ECS100US15  
ECS100US18  
ECS100US24  
ECS100US28  
ECS100US48  
Notes  
1. For Class B radiated emissions models, add suffix -B to model number. For covered versions, add suffix ‘-C’ to model number or order part no. ECM40/60 COVER  
KIT for standalone cover. Derate output power by 20% with cover. The cover is not suitable for Class II installations. ‘-C’ not available for ‘-B’ models.  
Mechanical Details  
1.25 (31.8)  
4.00 (101.6)  
3.750 (95.25)  
0.125 (3.18)  
C4  
Voltage  
Adj.  
1.750  
(44.45)  
2.00  
(50.8)  
J1  
C5  
T1  
J2  
Output Connector J2  
Molex PN 09-65-2048  
1.01  
(25.7)  
1.00  
(25.4)  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
+V1  
+V1  
RTN  
RTN  
Q1  
0.25 Faston  
Ground Tab  
0.20 (5.1)  
0.14 (3.5)  
0.125 (3.18)  
0.20 (5.1)  
SMD Component  
Height  
4 X ø.156 (3.96) Mounting Holes  
ø.312 (7.92) Clearance top and bottom  
Input Connector J1  
Molex PN 09-65-2038  
Pin 1  
Pin 2  
0.25” Faston  
Line  
Neutral  
Earth  
‘ ꢀB’ Model  
4.50 (114.3)  
3.75 (95.25)  
1.25 (31.8)  
0.37 (9.52)  
J1 mates with Molex Housing  
PN 09-50-1031, J2 mates with  
Molex Housing PN 09-50-1041  
and both with Molex Series 5194  
Crimp Terminals  
2.00  
(50.8)  
1.75  
(44.45)  
J1  
Notes  
J2  
0.20  
(5.1)  
1. All dimensions in inches (mm).  
Tolerance .xx = 0.02 (0.50);  
.xxx = 0.01 (0.25)  
1.00  
(25.4)  
1.01  
(25.7)  
2. Weight: 0.386 lbs (175 g)  
0.20 (5.1)  
0.14 (3.5)  
0.125 (3.18)  
SMD Component  
4 X ø.156 (3.96) Mounting Holes  
ø.312 (7.92) Clearance top and bottom  
Height  
0.10 (2.5)  
0.25 Faston Ground Tab  
Derating Curve ꢀ ECS100 Models  
100  
90  
100  
90  
Force-cooled >10 CFM  
Convection-cooled  
80  
80  
70  
60  
50  
40  
70  
60  
50  
40  
30  
Convection-cooled with cover  
+70  
80  
85  
90  
264  
-20  
+40  
+50  
+60  
Input Voltage (VAC)  
Ambient Temperature (ºC)  
ECS130  
Models and Ratings  
Output Power  
Output Voltage  
Output Current  
Model Number(1)  
Forced Cooled (10 CFM)  
Convection-cooled  
130 W  
130 W  
130 W  
130 W  
130 W  
130 W  
100 W  
100 W  
100 W  
100 W  
100 W  
100 W  
12.0 VDC  
15.0 VDC  
18.0 VDC  
24.0 VDC  
28.0 VDC  
48.0 VDC  
10.9 A  
8.7 A  
7.3 A  
5.4 A  
4.7 A  
2.7 A  
ECS130US12  
ECS130US15  
ECS130US18  
ECS130US24  
ECS130US28  
ECS130US48  
Notes  
1. For covered versions, add suffix ‘-C’ to model number or order part no. ECM40/60 COVER KIT for standalone cover, see derating curve.  
The cover is not suitable for Class II installations. ‘-C’.  
Mechanical Details  
4.00 (101.6)  
1.28  
0.125 (3.17)  
1.75 (44.45)  
3.750 (95.25)  
(32.5)  
Voltage Adjust  
C4  
N
J1  
2.00 (50.8)  
2
1
1
4
T1  
L
J2  
C5  
1.00 (25.4)  
1.05 (26.7)  
0.20 (5.1)  
Q1  
0.12 (3.18)  
0.15 (3.8)  
SMD COMPONENT HEIGHT  
0.20 (5.1)  
.25 FASTON  
GROUND TAB  
4X .156 (3.96) MOUNTING HOLES  
.312 (7.92) CLEARANCE TOP AND BOTTOM  
Output Connector J2  
Molex PN 09-65-2048  
Input Connector J1  
Notes  
Molex PN 09-65-2038  
1. All dimensions in inches (mm).  
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)  
2. Weight: 0.386 lbs (175 g)  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
+V1  
+V1  
RTN  
RTN  
Pin 1  
Pin 2  
0.25” Faston  
Line  
Neutral  
Earth  
J1 mates with Molex Housing PN 09-50-1031, J2 mates with Molex Housing PN 09-50-1041  
and both with Molex Series 5194 Crimp Terminals  
Derating Curve ꢀ ECS130 Models  
130  
130  
120  
110  
120  
110  
Forced-cooled >10 CFM  
Convection-cooled  
Forced-cooled >10 CFM  
Convection-cooled  
100  
90  
100  
90  
80  
70  
80  
70  
60  
60  
Convection-cooled with cover  
Convection-cooled with cover  
50  
40  
30  
20  
10  
50  
40  
30  
20  
10  
80  
90  
100  
264  
-40  
-20  
0
50  
60  
70  
Input Voltage (VAC)  
Ambient Temperature (ºC)  
ECS65/100/130  
Mechanical Details  
Covered Version (not available for ECS100ꢀB Models)  
4.49 (114.0)  
2.52  
(64.0)  
Input Connector  
Output Connector  
0.25 (0.6) Ground  
Faston Terminal  
0.807  
(20.50)  
1.54  
(39.0)  
2 x M3 x 0.5 THD  
0.16 (4.0)  
Max Screw Penetration  
4.055 (103.00)  
4.055 (103.00)  
0.22  
(5.5)  
0.22  
(5.5)  
0.79  
(20.0)  
0.984  
(25.00)  
4 x M3 x 0.5 THD  
0.16 (4.0) Max Screw Penetration  
Notes  
1. All dimensions in inches (mm).  
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)  
2. Weight: 0.8 lbs (360 g)  
Thermal Considerations ꢀ All Models  
In order to ensure safe and reliable operation of the PSU in the most adverse conditions permitted in the end-use equipment, the temperature of the components  
listed in the table below must not be exceeded. See mechanical drawing for component locations. Temperature should be monitored using K type thermocouples  
placed on the hottest part of the component (out of any direct air flow).  
Temperature Measurements (Ambient 50 °C)  
Component  
Max Temperature °C  
110 °C  
T1  
C5  
C4  
Q1  
100 °C  
100 °C  
110 °C  
30-May-14  

相关型号:

ECS130US28

AC-DC Regulated Power Supply Module, 130W
XPPOWER

ECS130US28-C

AC-DC Regulated Power Supply Module, 130W
XPPOWER

ECS130US48

Convection & Forced Cooled Ratings
XPPOWER

ECS1X5

Peripheral IC
ETC

ECS1X5-1.0

Micro Peripheral IC
ECS

ECS2100

Peripheral IC
ETC

ECS21P2131

COMMON MODE NOISE FILTERS
ABCO

ECS21P2181

COMMON MODE NOISE FILTERS
ABCO

ECS21P2201

COMMON MODE NOISE FILTERS
ABCO

ECS21P2271

COMMON MODE NOISE FILTERS
ABCO

ECS21P2361

COMMON MODE NOISE FILTERS
ABCO

ECS21P2551

COMMON MODE NOISE FILTERS
ABCO