65/100/130 Watts
ECS Series
xppower.com
•
•
•
•
•
•
•
IT & Medical Safety Approvals
65/80/100 W ꢀ Convectionꢀcooled Ratings
Class I & Class II Construction
Industry Standard 2” x 4” Package
<0.5 W No Load Input Power
Low Leakage Current
3 Year Warranty
Specification
Input
General
Input Voltage
• 80-264 VAC (275 VAC ECS65)
(120-370 VDC), derate output power
<90 VAC, see derating curves
Efficiency
Isolation
• Up to 90% model dependent
• 4000 VAC Input to Output, 2 x MOPP,
1500 VAC Input to Ground, 1 x MOPP,
500 VDC Output to Ground, 1 x MOPP
(1)
Input Frequency
Input Current
• 47-400 Hz
• 65 W: 1.0/0.6 A typical at 115/230 VAC
100 W: 1.5/0.9 A typical at 115/230 VAC,
130 W: 1.9/1.1 A typical at 115/230 VAC
full load
• 40 A max at 230 VAC, cold start at 25 ˚C
• EN61000-3-2, class A
Switching Frequency
Power Density
• 65 KHz typical
• 65 W: 7.7 W/in , 100 W: 10 W/in ,
130 W: 13 W/in
3
3
3
MTBF
• 65 W: 850 kHrs, 100 W: 834 kHrs,
130 W: 715 kHrs to MIL-HDBK-217F
at 25 ˚C, GB
Inrush Current
Power Factor
No Load Input Power • <0.5 W
Environmental
Operating Temperature • -20 ˚C (-40 ˚C, ECS130) to +70 ˚C derate
linearly from +50 ˚C at 2.5%/˚C to 50%
load at +70 ˚C.
Cooling
Operating Humidity
Storage Temperature • -40 ˚C to +85 ˚C
Operating Altitude
Shock
Earth Leakage Current • 65/130 W: 260 µA at 264 VAC/60 Hz max
100 W: 230 µA at 264 VAC/60 Hz max
Input Protection
• Internal T3.15/T5 A/250 V fuse in line and
neutral
• Convection & fan cooled ratings (see tables)
• 95% RH, non-condensing
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
• 12-48 VDC (see tables)
• 3000 m
• 30 g pk, half sine, 6 axes
• 2 g rms, 5 Hz to 500 Hz, 3 axes
•
•
10%
1%
Vibration
• No minimum load required
• 1 s typical
• 50 ms
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level
Emissions
• 16 ms min at 115 VAC
• EN55011/22 level B conducted
EN55011/22 level A radiated, level B
Suffix ‘-B’ models
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, installation class 3
Perf Criteria A
Drift
•
•
•
0.2% after 20 min warm up
0.5% max
1%
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
Harmonic Currents
Voltage Flicker
Radiated Immunity
EFT/Burst
• 5% typical
• 4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Surge
Ripple & Noise
• 1% pk-pk, 20 MHz bandwidth
Overvoltage Protection • 115-140% Vnom, recycle input to reset
Overload Protection • 110-160%
Short Circuit Protection • Continuous trip and restart (hiccup mode)
Conducted Immunity
Dips & Interruptions
• EN61000-4-6, level 3 Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms, Perf Criteria
A, A, A, B - 230 VAC. Consult longform
datasheet for 115 V operation.
Temperature
Coefficient
• 0.05%/˚C
Safety Approvals
• IEC60950-1 CB report, CSA 22.2
No. 60950-1, UL60950-1, TUV EN60950-1
IEC60601-1 CB report, CSA 22.2
No. 60601-1, ANSI/AMMI ES60601-1,
TUV 60601-1, including risk management
Equipment Protection • Class I & II (ECS65 Non ‘-B’ models,
Class Class I only)
Notes
1. Safety approvals cover frequency 47-63 Hz.
ECS65
Models and Ratings
Output Power
Output Voltage
Output Current
Model Number(1)
65 W
65 W
65 W
65 W
65 W
65 W
12.0 VDC
15.0 VDC
18.5 VDC
24.0 VDC
28.0 VDC
48.0 VDC
5.4 A
4.3 A
3.4 A
2.7 A
2.3 A
1.4 A
ECS65US12
ECS65US15
ECS65US18
ECS65US24
ECS65US28
ECS65US48
Notes
1. For Class B radiated emissions models, add suffix -B to model number. For covered versions, add suffix ‘-C’ to model number or order part no. ECM40/60 COVER
KIT for standalone cover. Derate output power by 20% with cover. The cover is not suitable for Class II installations.
Mechanical Details
4.00 (101.6)
3.750 (95.25)
1.05
(26.7)
0.125 (3.17)
C4
1
2.00 (50.8)
1.75 (44.45)
2
1
C5
J1
T1
1
4
J2
0.95 (24.1)
0.96 (24.5)
0.25 Faston Ground Tab
0.125 (3.18)
0.20 (5.1)
Q1
0.14 (3.5)
SMD Component Height
0.20 (5.1)
4 X ø.156 (3.96) Mounting Holes
ø.312 (7.92) Clearance top and bottom
Input Connector J1
Molex PN 09-65-2038
Output Connector J2
Molex PN 09-65-2048
Pin 1
Pin 2
0.25” Faston
Line
Neutral
Earth
Pin 1
Pin 2
Pin 3
Pin 4
+V1
+V1
RTN
RTN
J1 mates with Molex Housing PN 09-50-1031, J2 mates with
Molex Housing PN 09-50-1041 and both with Molex Series 5194
Crimp Terminals
Notes
1. All dimensions in inches (mm).
2. Weight: 0.386 lbs (175 g)
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
Derating Curve ꢀ ECS65 Models
Some Specification Parameters
may not be met
100
90
100
90
Open Frame
With Cover
80
80
70
60
50
40
70
60
50
40
30
80
85
90
275
70
40
50
60
Input Voltage (VAC)
Ambient Temperature (ºC)
ECS100
Models and Ratings
Output Power
Output Voltage
Output Current
Model Number(1)
Forced Cooled (10 CFM)
Convection-cooled
100 W
100 W
100 W
100 W
100 W
100 W
80 W
80 W
80 W
80 W
80 W
80 W
12.0 VDC
15.0 VDC
18.0 VDC
24.0 VDC
28.0 VDC
48.0 VDC
8.3 A
6.7 A
5.5 A
4.2 A
3.6 A
2.1 A
ECS100US12
ECS100US15
ECS100US18
ECS100US24
ECS100US28
ECS100US48
Notes
1. For Class B radiated emissions models, add suffix -B to model number. For covered versions, add suffix ‘-C’ to model number or order part no. ECM40/60 COVER
KIT for standalone cover. Derate output power by 20% with cover. The cover is not suitable for Class II installations. ‘-C’ not available for ‘-B’ models.
Mechanical Details
1.25 (31.8)
4.00 (101.6)
3.750 (95.25)
0.125 (3.18)
C4
Voltage
Adj.
1.750
(44.45)
2.00
(50.8)
J1
C5
T1
J2
Output Connector J2
Molex PN 09-65-2048
1.01
(25.7)
1.00
(25.4)
Pin 1
Pin 2
Pin 3
Pin 4
+V1
+V1
RTN
RTN
Q1
0.25 Faston
Ground Tab
0.20 (5.1)
0.14 (3.5)
0.125 (3.18)
0.20 (5.1)
SMD Component
Height
4 X ø.156 (3.96) Mounting Holes
ø.312 (7.92) Clearance top and bottom
Input Connector J1
Molex PN 09-65-2038
Pin 1
Pin 2
0.25” Faston
Line
Neutral
Earth
‘ ꢀB’ Model
4.50 (114.3)
3.75 (95.25)
1.25 (31.8)
0.37 (9.52)
J1 mates with Molex Housing
PN 09-50-1031, J2 mates with
Molex Housing PN 09-50-1041
and both with Molex Series 5194
Crimp Terminals
2.00
(50.8)
1.75
(44.45)
J1
Notes
J2
0.20
(5.1)
1. All dimensions in inches (mm).
Tolerance .xx = 0.02 (0.50);
.xxx = 0.01 (0.25)
1.00
(25.4)
1.01
(25.7)
2. Weight: 0.386 lbs (175 g)
0.20 (5.1)
0.14 (3.5)
0.125 (3.18)
SMD Component
4 X ø.156 (3.96) Mounting Holes
ø.312 (7.92) Clearance top and bottom
Height
0.10 (2.5)
0.25 Faston Ground Tab
Derating Curve ꢀ ECS100 Models
100
90
100
90
Force-cooled >10 CFM
Convection-cooled
80
80
70
60
50
40
70
60
50
40
30
Convection-cooled with cover
+70
80
85
90
264
-20
+40
+50
+60
Input Voltage (VAC)
Ambient Temperature (ºC)
ECS130
Models and Ratings
Output Power
Output Voltage
Output Current
Model Number(1)
Forced Cooled (10 CFM)
Convection-cooled
130 W
130 W
130 W
130 W
130 W
130 W
100 W
100 W
100 W
100 W
100 W
100 W
12.0 VDC
15.0 VDC
18.0 VDC
24.0 VDC
28.0 VDC
48.0 VDC
10.9 A
8.7 A
7.3 A
5.4 A
4.7 A
2.7 A
ECS130US12
ECS130US15
ECS130US18
ECS130US24
ECS130US28
ECS130US48
Notes
1. For covered versions, add suffix ‘-C’ to model number or order part no. ECM40/60 COVER KIT for standalone cover, see derating curve.
The cover is not suitable for Class II installations. ‘-C’.
Mechanical Details
4.00 (101.6)
1.28
0.125 (3.17)
1.75 (44.45)
3.750 (95.25)
(32.5)
Voltage Adjust
C4
N
J1
2.00 (50.8)
2
1
1
4
T1
L
J2
C5
1.00 (25.4)
1.05 (26.7)
0.20 (5.1)
Q1
0.12 (3.18)
0.15 (3.8)
SMD COMPONENT HEIGHT
0.20 (5.1)
.25 FASTON
GROUND TAB
4X .156 (3.96) MOUNTING HOLES
.312 (7.92) CLEARANCE TOP AND BOTTOM
Output Connector J2
Molex PN 09-65-2048
Input Connector J1
Notes
Molex PN 09-65-2038
1. All dimensions in inches (mm).
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
2. Weight: 0.386 lbs (175 g)
Pin 1
Pin 2
Pin 3
Pin 4
+V1
+V1
RTN
RTN
Pin 1
Pin 2
0.25” Faston
Line
Neutral
Earth
J1 mates with Molex Housing PN 09-50-1031, J2 mates with Molex Housing PN 09-50-1041
and both with Molex Series 5194 Crimp Terminals
Derating Curve ꢀ ECS130 Models
130
130
120
110
120
110
Forced-cooled >10 CFM
Convection-cooled
Forced-cooled >10 CFM
Convection-cooled
100
90
100
90
80
70
80
70
60
60
Convection-cooled with cover
Convection-cooled with cover
50
40
30
20
10
50
40
30
20
10
80
90
100
264
-40
-20
0
50
60
70
Input Voltage (VAC)
Ambient Temperature (ºC)
ECS65/100/130
Mechanical Details
Covered Version (not available for ECS100ꢀB Models)
4.49 (114.0)
2.52
(64.0)
Input Connector
Output Connector
0.25 (0.6) Ground
Faston Terminal
0.807
(20.50)
1.54
(39.0)
2 x M3 x 0.5 THD
0.16 (4.0)
Max Screw Penetration
4.055 (103.00)
4.055 (103.00)
0.22
(5.5)
0.22
(5.5)
0.79
(20.0)
0.984
(25.00)
4 x M3 x 0.5 THD
0.16 (4.0) Max Screw Penetration
Notes
1. All dimensions in inches (mm).
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
2. Weight: 0.8 lbs (360 g)
Thermal Considerations ꢀ All Models
In order to ensure safe and reliable operation of the PSU in the most adverse conditions permitted in the end-use equipment, the temperature of the components
listed in the table below must not be exceeded. See mechanical drawing for component locations. Temperature should be monitored using K type thermocouples
placed on the hottest part of the component (out of any direct air flow).
Temperature Measurements (Ambient ≤ 50 °C)
Component
Max Temperature °C
110 °C
T1
C5
C4
Q1
100 °C
100 °C
110 °C