ECS60US05_16 [XPPOWER]
25-60 Watts ECS Series;型号: | ECS60US05_16 |
厂家: | XP POWER LIMITED |
描述: | 25-60 Watts ECS Series |
文件: | 总4页 (文件大小:1016K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
25-60 Watts
ECS Series
xppower.com
•
•
•
•
•
•
•
IT & Medical Safety Approvals
Very Small 2”x 3”x 0.95”Package
<0.3 W No Load Input Power
25, 45 & 60 W - Convection Cooled Ratings
Class I & Class II Installations
-20 °C to +70 °C Operation
3 Year Warranty
Specification
Input
General
Efficiency
Isolation
• Up to 90%, model dependant
Input Voltage
• 80-264 VAC (120-370 VDC), derate linearly
from 100% at 90 VAC to 80% at 80 VAC
• 4000 VAC In to Out, 2 x MOPP, 1500 VAC In
to Earth, 1 x MOPP, 500 VDC Out to Earth, 1
x MOPP
(1)
Input Frequency
Input Current
• 47-400 Hz
• 25 W: 0.45 A, 45 W: 0.75 A, 60 W: 0.95 A
typical at 115 VAC, full load,
25 W: 0.30 A, 45 W: 0.45 A, 60 W: 0.60 A,
typical at 230 VAC, full load
• 40 A max at 230 VAC, cold start 25 ˚C
• EN61000-3-2, class A
Switching Frequency
Power Density
MTBF
• 65 KHz typical
3
• Up to 7.9 W/in
• 25 & 45 W: 1072 kHrs, 60 W: 471 kHrs to
MIL-HDBK-217F at 25 ˚C, GB
Inrush Current
Power Factor
Environmental
Operating Temperature • -20 ˚C to +70 ˚C derate linearly from +50 ˚C
No Load Input Power • US05, 12 & 24 models: <0.3 W,
US48 and all ECS60 models: <0.5 W
at 2.5%/˚C to 50% load at +70 ˚C.
Earth Leakage Current • 260 µA at 264 VAC/60 Hz max,
Cooling
• Convection, see thermal considerations
• 95% RH, non-condensing
• -40 ˚C to +85 ˚C
• 3000 m
• 30 g pk, half sine, 6 axes
• 2 g rms, 5 Hz to 500 Hz, 3 axes
80/160 µA typical 115/230 VAC
• T3.15 A/250 V internal fuse in line
and neutral
Operating Humidity
Storage Temperature
Operating Altitude
Shock
Input Protection
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
• 5-48 VDC (see tables)
Vibration
•
•
10%
1%
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level
• No minimum load required
• 1 s typical
• 50 ms
Emissions
• All models: EN55011/22 level B conducted.
45 & 60 W: EN55011/22 level A radiated,
ECS25 & ECS60US24/48 models: level B
radiated
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, installation class 3
Perf Criteria A
• 16 ms min at 115 VAC
Drift
•
•
•
0.2% after 20 min warm up
0.5% max
1%
Harmonic Currents
Voltage Flicker
Radiated Immunity
EFT/Burst
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
• 5% typical
• 4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Surge
Conducted Immunity
Dips & Interruptions
• EN61000-4-6, level 3 Perf Criteria A
(2)
Ripple & Noise
• 1% pk-pk V1, 20 MHz bandwidth
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms, Perf Criteria
A, A, A, B - 230 VAC. Consult longform
datasheet for 115 V operation.
Overvoltage Protection • 115-140% Vnom, recycle input to reset
Overload Protection • 110-160%
Short Circuit Protection • Continuous trip and restart (hiccup mode)
Temperature
Coefficient
• 0.05%/˚C
Safety Approvals
• IEC60950-1 CB report, UL60950-1,
TUV EN60950-1, IEC60601-1 CB report,
ANSI/AAMI ES60601-1, TUV 60601-1,
Including Risk Management
Notes
1. Safety approvals cover frequency 47-63 Hz.
2. ECS60US12 1.5% pk-pk, 20 MHz bandwidth under certain line/load conditions.
3. See longform datasheet or contact sales for details.
Equipment Protection • Class I and Class II
Class
ECS25
Models and Ratings
Output Power
25 W
Output Voltage
12.0 VDC
Output Current
2.08 A
Model Number(1)
ECS25US12
ECS25US15
ECS25US24
ECS25US48
25 W
15.0 VDC
1.67 A
25 W
24.0 VDC
1.04 A
25 W
48.0 VDC
0.52 A
Notes
1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations,
derate output power by 20% with cover.
Mechanical Details
4 x Ø.156 (3.96) Mounting Holes
2.75 (69.8)
Ø.312 (7.92) Clearance Top and Bottom
Input Connector J1
Molex PN 09-65-2038
Pin 1
Pin 2
0.25” Faston
Line
Neutral
Earth
2
1
1
2
J1
J2
3
4
C18
C5
1.75
2.00
Output Connector J2
Molex PN 09-65-2048
(44.4)
(50.8)
1.65
(41.8)
1.31
(33.3)
Pin 1
+V1
+V1
RTN
RTN
T1
Pin 2
Pin 3
Pin 4
Q1
0.27
(7.0)
0.20
0.25 (0.6) Faston Ground Tab
(5.1)
J1 mates with Molex Housing PN 09-50-1031,
J2 mates with Molex Housing PN 09-50-1041 and
both with Molex Series 5194 Crimp Terminals
3.00 (76.2)
Notes
0.14 (3.6)
0.95 (24.2)
1. All dimensions in inches (mm).
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
2. Weight 0.22 lbs (100 g)
SMD Height
Covered version (All ECS25-60 Models)
4 x M3 x 0.5 THD
0.16 (4.0) Max
4 x M3 x 0.5 THD
0.16 (4.0) Max
Screw Penetration
Screw Penetration
1.26
0.63
(32.0)
(16.0)
Output Connector
0.22 (5.7)
J2
1
4
3.03
3.48
(76.99)
3.03
(88.4)
(76.9)
1
2
J1
0.22 (5.7)
Input
0.25 (0.6) Faston Ground Tab
0.70
Top View
Connector
2.52
(17.79)
(64.0)
Bottom View
1.23 (31.28)
1.40
(35.6)
Notes
1. All dimensions in inches (mm).
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
2. Weight 0.5 lbs (230 g)
ECS45
Models and Ratings
Output Power
30 W
Output Voltage
5.0 VDC
Output Current
6.00 A
Model Number(1)
ECS45US05
ECS45US12
ECS45US15
ECS45US24
ECS45US48
45 W
12.0 VDC
15.0 VDC
24.0 VDC
48.0 VDC
3.75 A
45 W
3.00 A
45 W
1.90 A
45 W
0.95 A
Notes
1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations,
derate output power by 20% with cover.
Mechanical Details
4 x Ø.156 (3.96) Mounting Holes
Ø.312 (7.92) Clearance Top and Bottom
2.75 (69.9)
5 V version
2
1
1
2
J1
C18
J2
2.00
C5
3
4
(50.8)
Input Connector J1
Molex PN 09-65-2038
1.75
(44.5)
1.58
Pin 1
Line
Neutral
Earth
(40.3)
1.30
(33.0)
Pin 2
T1
0.25” Faston
Output Connector J2
Molex PN 09-65-2048
Q1
0.28
(7.0)
0.20
(5.1)
Pin 1
+V1
+V1
RTN
RTN
0.25 (0.6) Faston Ground Tab
Pin 2
Pin 3
Pin 4
3.00 (76.2)
J1 mates with Molex Housing PN
09-50-1031,
J2 mates with Molex Housing
PN 09-50-1041 and both with Molex
Series 5194 Crimp Terminals
1.05
(26.7)
0.14 (3.6) SMD Height Limit
4 x Ø.156 (3.96) Mounting Holes
Ø.312 (7.92) Clearance Top and Bottom
12-48 V version
2.75 (69.9)
2
1
1
2
J1
J2
3
4
C18
Input Connector J1
C5
2.00
Molex PN 09-65-2038
(50.8 )
1.75
1.65
Pin 1
Pin 2
0.25” Faston
Line
Neutral
Earth
(44.5)
(41.8)
1.31
(33.3)
T1
Output Connector J2
Molex PN 09-65-2048
Q1
Pin 1
+V1
+V1
RTN
RTN
0.28
(7.0)
0.20
(5.1)
0.25 (0.6) Faston Ground Tab
3.00 (76.2)
Pin 2
Pin 3
Pin 4
J1 mates with Molex Housing PN
09-50-1031,
J2 mates with Molex Housing PN 09-
50-1041 and both with Molex Series
5194 Crimp Terminals
0.95
(24.2)
0.14 (3.6)
SMD Height
Notes
1. All dimensions in inches (mm).
2. Weight 0.22 lbs (100 g)
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
ECS60
Models and Ratings
Output Power
40 W
Output Voltage
5.0 VDC
Output Current
8.00 A
Model Number(1)
ECS60US05
ECS60US12
ECS60US15
ECS60US24
ECS60US48
60 W
12.0 VDC
15.0 VDC
24.0 VDC
48.0 VDC
5.00 A
60 W
4.00 A
60 W
2.50 A
60 W
1.25 A
Notes
1. For covered versions, add suffix ‘-C’ to model number or order part number ECS25-60 COVER KIT for standalone cover. Not suitable for use in class II installations,
derate output power by 20% with cover.
Mechanical Details
0.28 (7.1)
4 x ø0.156 (3.96) mounting holes
ø3.12 (7.92) clearance top and bottom
1.05 (26.7)
0.20 (5.1)
A
1
4
J2
C18
2.00
(50.8)
1.75
C5
(44.4)
1.62
(41.1)
1.30
(33.0)
T1
A
Q1
0.14 (3.5)
0.12
(3.18)
Components may
extend beyond
edge of PCB
0.25 faston ground tab
0.12
(3.1)
2.75 (69.8)
by 0.04 (1.0)
3.00 (76.2)
Mounting points A should be connected together for optimum EMI performance
Output Connector J2
Molex PN 09-65-2048
Input Connector J1
Molex PN 09-65-2038
Pin 1
+V1
+V1
RTN
RTN
Pin 1
Pin 2
Line
Neutral
Earth
Pin 2
Pin 3
Pin 4
0.25” Faston
J1 mates with Molex Housing PN 09-50-1031
J2 mates with Molex Housing PN 09-50-1041
and both with Molex Series 5194 Crimp Terminals
Notes
1. All dimensions in inches (mm).
2. Weight: 0.22 lbs (100 g)
Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)
Thermal Considerations (All ECS25-60 Models)
In order to ensure safe and reliable operation of the PSU in the most adverse
Temperature Measurements (Ambient ≤50 °C)
conditions permitted in the end-use equipment, the temperature of the
components listed in the table must not be exceeded. See mechanical
drawings for component locations. Temperature should be monitored using
K type thermocouples placed on the hottest part of the component (out of
any direct air flow).
Component
Max Temperature ºC
T1
Q1
C5
110 °C
110 °C
100 °C
100 °C
C18
24 Mar 16