GSP500 [XPPOWER]

AC-DC Power Supplies;
GSP500
型号: GSP500
厂家: XP POWER LIMITED    XP POWER LIMITED
描述:

AC-DC Power Supplies

文件: 总8页 (文件大小:1146K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
AC-DC Power Supplies  
GSP500 Series  
500 Watts  
• Convection/Forced-cooled Ratings  
• Universal 80 - 264 VAC Input  
• IT & Medical Safety Approvals  
• < 0.5 W Standby Power  
• -40° C to +70° C Operation  
• Remote On/Off  
• 5 V/2 A Standby Output  
• 3 Year Warranty  
Dimensions:  
The GSP500 has been designed to offer a full 500W of output power in a very small mechanical  
footprint, whilst still providing peak power to 650W, a 5V standby output with 2Amps of current  
capability and an input standby power draw of < 0.5W when the inhibit is activated.  
GSP:  
6.00 x 4.00 x 1.65” (152.4 x 101.6 x 41.9 mm)  
(-EF): 6.71 x 4.00 x 1.65” (170.4 x 101.6 x 41.9 mm)  
Approved for both IT and medical applications the series has output versions from 12V to 48V  
and can be supplied as a U channel for system cooling or with optional very quiet integral fans  
(-EF). These fans are intelligently controlled to provide the most optimised accoustic noise in the  
system and further more the GSP500 can provide up to 180W without forced cooling, thus  
allowing fans to be switched off during periods of lower system loading.  
Models & Ratings  
Output Current V1  
Standby Supply  
Max Output Power  
Output  
Voltage  
(1,3)  
Fan Supply  
Model Number  
(2)  
Convection  
Forced  
Convection  
Forced  
5 V/2 A  
5 V/2 A  
5 V/2 A  
Nom  
Peak  
12.0 VDC  
24.0 VDC  
48.0 VDC  
15.00 A  
7.50 A  
3.75 A  
42.0 A  
21.0 A  
10.5 A  
5 V/1 A  
5 V/1 A  
5 V/1 A  
12 V/0.3 A  
12 V/0.3 A  
12 V/0.3 A  
500 W  
500 W  
500 W  
650 W  
650 W  
650 W  
GSP500PS12-EF  
GSP500PS24-EF  
GSP500PS48-EF  
Notes  
1. Remove suffix -EF (EndFan) for use with integral system cooling.  
2. Peak power available for 100 ms maximum with a 10% duty cycle. The average power in a period should be equal or less than the normal power.  
3. For optional current share version, add suffix ‘P’, e.g. GSP500PS24P or GSP500PS24P-EF.  
Mechanical Details  
6.71 (170.40)  
LOGIC CONNECTOR  
0.08 (2.00)  
0.63 (15.90)  
1
3
9 10  
2 1  
FAN CONNECTOR  
LED  
M4 SCREW-2X  
TORQUE: 10.62lbs-in(1.2Nm) Max.  
1.14 (28.90)  
0.77 (19.45)  
4.00 (101.60)  
VOUT (-)  
VOUT (+)  
1.93 (48.94)  
M3.5 SCREW 9.5mm CENTER  
TORQUE: 10.62lbs-in(1.2Nm) Max.  
N
L
0.82 (20.95)  
7.00 (177.79)  
5.65 (143.40)  
0.02 (0.50)  
A
1.65 (41.90)  
AIRFLOW  
DIRECTION  
A
1.30 (33.00)  
0.21 (5.39)  
0.98 (24.90)  
0.20 (5.00)  
www.xppower.com  
1
AC-DC Power Supplies  
GSP500 Series  
Input  
Characteristic  
Minimum  
Typical  
Maximum  
264  
Units  
VAC  
VAC  
Hz  
Notes & Conditions  
Input Voltage - Operating  
Input Voltage - Fault condition  
Input Frequency  
80  
115/230  
Derate output power <90 VAC. See fig 1.  
5 second max  
300  
47  
50/60  
63  
>
Power Factor  
0.9  
230 VAC, 100% load  
115/230 VAC  
Input Current - Full Load  
Inrush Current  
5.0/2.4  
60  
A
A
0.5  
All models, when inhibit activated  
GSP500PS12 - 115 VAC  
3.0  
1.3  
GSP500PS12 - 230 VAC  
No Load Input Power  
3.0  
W
GSP500PS24 - 115 VAC  
1.2  
GSP500PS24 - 230 VAC  
4.8  
GSP500PS48 - 115 VAC  
2.3  
GSP500PS48 - 230 VAC  
Earth Leakage Current  
Input Protection  
80/220  
250  
µA  
115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max.  
F16 A/250 V internal fuse in both lines  
Output  
Characteristic  
Minimum  
Typical  
Maximuµm  
Units  
VDC  
%
Notes & Conditions  
Output Voltage - V1  
Initial Set Accuracy  
Output Voltage Adjustment  
Minimum Load  
Start Up Delay  
Hold Up Time  
12  
48  
1
See Models and Ratings table  
50% load, 115/230 VAC  
+1,-3  
%
0
A
0.5  
2
s
115/230 VAC full load from input AC turn on  
20  
ms  
%
Drift  
0.2  
0.5  
1.0  
After 20 min warm up  
90-264 VAC  
Line Regulation  
Load Regulation  
0.01  
0.2  
%
%
0-100% load  
Recovery within 1% in less than 500 µs  
for a 50-75% and 75-50% load step  
Transient Response  
4
%
Over/Undershoot  
0
%
Ripple & Noise  
0.5  
1.5  
140  
150  
% pk-pk  
%
20 MHz bandwidth  
Overvoltage Protection  
Overload Protection  
Short Circuit Protection  
Temperature Coefficient  
Overtemperature Protection  
115  
110  
Vnom DC. Output 1, recycle input to reset  
See fig. 2. Trip and Restart  
Shutdown & auto recovery  
% I nom  
0.05  
%/˚C  
Shutdown & auto recovery  
Input Voltage Derating Curve  
Output Overload Characteristic  
Figure 1  
Figure 2  
GSP500PS12 example (others similar).  
12  
Trip & Restart  
550  
500  
450  
400  
350  
300  
10  
8
6
4
2
0
0
42  
44  
46  
48  
50  
52  
54  
56  
58  
60  
80  
85  
90  
300  
264  
Output Load (A)  
Input Voltage (VAC)  
www.xppower.com  
2
AC-DC Power Supplies  
GSP500 Series  
General  
Characteristic  
Minimum  
Typical  
Maximum  
Units  
%
Notes & Conditions  
230 VAC Full load (see fig.3-5)  
2 x MOPP  
Efficiency  
90  
4000  
1500  
500  
VAC  
VAC  
VDC  
Isolation: Input to Output  
Input to Ground  
1 x MOPP  
Output to Ground  
65  
90  
PFC Converter  
Switching Frequency  
50  
200  
kHz  
Main Converter  
Standby Converter  
100  
3
Power Density  
12.6  
W/in  
Mean Time Between Failure  
216  
1.87 (0.85)  
1.98 (0.90)  
kHrs  
MIL-HDBK-217F, Notice 2 +25 °C GB  
GSP500PSxx models  
GSP500PSxx-EF models  
Weight  
lb (kg)  
Efficiency Vs Load  
100 %  
Figure 3  
12 V Models  
80 %  
60 %  
40 %  
20 %  
0 %  
115Vac  
230Vac  
0%  
20%  
40%  
60%  
LOAD  
80%  
100%  
Figure 4  
24 V Models  
100 %  
80 %  
60 %  
40 %  
20 %  
0 %  
115Vac  
230Vac  
0%  
20%  
40%  
60%  
80%  
100%  
LOAD  
100 %  
80 %  
60 %  
40 %  
20 %  
0 %  
Figure 5  
48 V Models  
115Vac  
230Vac  
0%  
20%  
40%  
60%  
80%  
100%  
LOAD  
www.xppower.com  
3
AC-DC Power Supplies  
GSP500 Series  
Signals & Controls  
Characteristic  
Notes & Conditions  
Open collector referenced to negative sense, transistor normally on when power is good (see fig. 5); power is considered good when  
PFC bulk capacitor voltage is normal. PF: Provides ≥ 5 ms warning of loss of output from power failure.  
Power Fail (PF)  
Uncommited isolated optocoupler diode, powered diode inhibits both V1 and fan supply (see fig. 6). During inhibit the standby  
supply and current should be limited to 1 A for thermal reasons.  
Inhibit  
Output Good  
LED Indicator  
Fan Speed Control  
GSP500PSxx-EF Models  
The fan speed is set to one of 4 states (high, mid, low or off) dependant on the internal power supply ambient temperature,  
input voltage and output load at any given time.  
Standby Supply  
Remote Sense  
5V/2A Isolated supply present when AC applied.  
Compensates for 0.5 V total voltage drop.  
Optional, on ‘P’ version only. Connecting pins 5 or 6 on one unit to pins 5 or 6 on another like voltage unit will force the current to be  
shared within 10% between the two outputs. Up to three units can share current. (see fig. 7)  
Current Share  
Power Fail (PF)  
Remote On/Off (Inhibit)  
Current Share  
Figure 5  
Figure 6  
Figure 7  
INHIBIT HI  
INHIBIT LOW  
GSP500PSXX  
V1 Output  
GSP500PSXX (2)  
GSP500PSXX (3)  
V1 Output  
1.5K  
POWER SUPPLY  
POWER SUPPLY  
1.5K  
POWER SUPPLY  
5 V Standby  
V1 Output  
5 V Standby  
Pin 9  
5 V Standby  
Pin 9  
-
+
-
+
-
+
Pin 9  
Typical 2 mA  
(min requirement 500 µA)  
Current  
Share  
Current  
Share  
10K  
100 R  
250 µA  
100 R  
Pin 9  
Inhibit Hi  
Pin 7  
Typical 500 µA  
PF Collector  
(max allowable 600 µA)  
Pin 3  
Inhibit Hi  
Pin 7  
Transistor On (<0.8 V):  
POWER OK  
Transistor Off (>3.5 V):  
POWER NOT OK  
PF Emitter Pin 2  
(-sense)  
Inhibit Lo  
Pin 8  
Inhibit Lo  
Pin 8  
5 V Standby  
Return Pin 10  
5 V Standby  
Return Pin 10  
5 V Standby  
Return Pin 10  
-
+
Chassis J301 Logic Connector  
J301 Logic Connector  
Chassis J301 Logic Connector  
Signal High: Power Supply OFF  
Low or Floating: Power Supply ON  
Signal  
High: Power Supply ON  
Low or Floating: Power Supply OFF  
Load  
Environmental  
Characteristic  
Operating Temperature  
Storage Temperature  
Cooling  
Humidity  
Operating Altitude  
Minimum  
Typical  
Maximum  
+70  
+85  
Units  
°C  
°C  
CFM  
%RH  
m
Notes & Conditions  
Start up at -40 °C. See derating curve, fig. 8  
-20  
-40  
12  
5
GSP500PSxx models  
Non-condensing  
95  
5000  
59.9  
52.2  
36.6  
Lw db(A)  
Lw db(A)  
Lw db(A)  
Full Speed  
Mid Speed  
Low Speed  
Accoustic Fan Noise  
GSP500PSxx-EF Models  
3 x 30g shocks in each plane, total 18 shocks. 30g =  
11ms (+/-0.5msec), half sine. Conforms to EN60068-2-27  
& EN60068-2-47  
Shock  
Single axis 10 - 500 Hz at 2g sweep and endurance at  
resonance in all 3 planes. Conforms to EN60068-2-6  
Vibration  
500  
Thermal Derating Curve  
Figure 8  
Forced-cooled  
250  
180  
Convection-cooled  
0
90  
0
-40  
-20  
+50  
+70  
Ambient Temperature (ºC)  
www.xppower.com  
4
AC-DC Power Supplies  
GSP500 Series  
EMC: Emissions  
Phenomenon  
Standard  
Test Level  
Class B  
Notes & Conditions  
Conducted  
EN55011/22  
EN55011/22  
EN61000-3-3  
Class A  
Radiated  
With 1 Turn Wurth 742 712 22 core or similar on output  
lead  
Class B  
Harmonic Fluctuations  
EMC: Immunity  
Phenomenon  
Standard  
Test Level  
Criteria  
Notes & Conditions  
Low Voltage PSU EMC  
EN61204-3  
High severity level  
as below  
Class A  
All models  
> 50 W  
Harmonic Current  
EN61000-3-2  
Class C  
Radiated  
EFT  
EN61000-4-3  
EN61000-4-4  
3
3
A
A
Surges  
EN61000-4-5  
EN61000-4-6  
Installation class 3  
A
Conducted  
3
A
A
A
B
A
A
B
A
A
A
B
A
A
A
B
Dip >95% (0 VAC), 8.3ms  
Dip 30% (70 VAC), 416ms  
Dip >95% (0 VAC), 4160ms  
Dip >95% (0 VAC), 10.0ms  
Dip 30% (168 VAC), 500ms  
Dip >95% (0 VAC), 5000ms  
Dip >95% (0 VAC), 10.0ms  
Dip 60% (40 VAC), 100ms  
Dip 30% (70 VAC), 500ms  
Dip >95% (0 VAC), 5000ms  
Dip >95% (0 VAC), 10.0ms  
Dip 60% (96 VAC), 100ms  
Dip 30% (168 VAC), 500ms  
Dip >95% (0 VAC), 5000ms  
EN55024  
(100 VAC)  
EN55024  
(240 VAC)  
Dips and Interruptions  
Derate Output Power to 250 W  
EN60601-1-2  
(100 VAC)  
EN60601-1-2  
(240 VAC)  
Safety Approvals  
Safety Agency  
Safety Standard  
Notes & Conditions  
Information Technology  
Medical  
IEC60950-1:2005 Ed 2  
CB Report  
UL  
IEC60601-1 Ed 3 Including Risk Management  
UL60950-1 (2007), CSA 22.2 No.60950-1-1:08  
Information Technology  
ANSI/AAMI ES60601-1:2005 & CSA C22.2, No.60601-1:08 Medical  
EN60950-1:2006  
EN60601-1/A12:2006  
LVD & RoHS  
Information Technology  
TUV  
Medical  
CE  
Equipment Protection Class  
Class I  
See safety agency conditions of acceptibility for details  
Means of Protection  
Category  
Primary to Secondary  
Primary to Earth  
2 x MOPP (Means of Patient Protection)  
1 x MOPP (Means of Patient Protection)  
IEC60601-1 Ed 3  
www.xppower.com  
55  
AC-DC Power Supplies  
GSP500 Series  
Mechanical Details  
GSP500-EF  
1.30 (33.00) X 2  
A
A
0.20 (5.00)  
5.65 (143.40)  
6.71 (170.40)  
LOGIC CONNECTOR  
0.08 (2.00)  
0.63 (15.90)  
1
3
9 10  
2 1  
FAN CONNECTOR  
LED  
M4 SCREW-2X  
TORQUE: 10.62lbs-in(1.2Nm) Max.  
1.14 (28.90)  
0.77 (19.45)  
4.00 (101.60)  
VOUT (-)  
VOUT (+)  
1.93 (48.94)  
M3.5 SCREW 9.5mm CENTER  
TORQUE: 10.62lbs-in(1.2Nm) Max.  
N
L
0.82 (20.95)  
7.00 (177.79)  
5.65 (143.40)  
0.02 (0.50)  
DETAIL A  
Mounting Hole  
8 PLCS M3 X 0.5  
A
1.65 (41.90)  
AIRFLOW  
A
DIRECTION  
0.15 (3.8) MAX Penetration  
Torque: 5 lb/in (0.6 Nm)  
1.30 (33.00)  
0.21 (5.39)  
0.98 (24.90)  
0.20 (5.00)  
6.00 (152.40)  
5.41 (137.40) X 2  
Logic Connector(3)  
for standard versions  
JST B10B-PHDSS  
A
A
Pin  
1
2
3
4
5
6
7
Function  
+Sense  
-Sense  
4.00 (101.60)  
2.36 (60.00)  
C
L
Power Fail  
No Connection  
No Connection  
No Connection  
+Inhibit  
A
A
8
9
10  
-Inhibit  
+5V Standby  
-5V Standby  
0.39 (10.00)X2  
(3)  
(3)  
Fan Connector  
Logic Connector  
S3B-PH-KL(LF)  
For Current Share Versions -P  
JST B10B-PHDSS  
Pin  
1
2
Function  
+12 V  
N/C  
Pin  
1
2
Function  
+Sense  
-Sense  
3
GND  
3
4
5
6
Power Fail  
No Connection  
Current Share  
Current Share  
+Inhibit  
Notes  
7
1. All dimensions in inches (mm).  
2. Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)  
3. Fan connector mates with JST housing PHR-3 and SPH-002T-P0.5S crimp  
terminals or equivalent. Logic connector J301 mates with JST housing  
PHDR-10VS and SPHD-001T-P0.5 crimp terminals.  
8
9
10  
-Inhibit  
+5V Standby  
-5V Standby  
www.xppower.com  
6
AC-DC Power Supplies  
GSP500 Series  
Mechanical Details  
GSP500  
1.30 (33.00) X2  
A
A
0.20 (5.00)  
5.65 (143.40)  
6.00 (152.40)  
LOGIC CONNECTOR  
0.63 (15.9) X2  
1
3
9 10  
2 1  
FAN CONNECTOR  
LED  
M4 SCREW-2X  
TORQUE: 10.62lbs-in(1.2Nm) Max.  
1.14 (28.90)  
0.77 (19.45)  
VOUT (-)  
VOUT (+)  
4.00 (101.60)  
N
L
5.65 (143.40)  
0.02 (0.50)  
DETAIL A  
A
1.65 (41.90)  
Mounting Hole  
AIRFLOW  
A
8 PLCS M3 X 0.5  
0.15[3.8] MAX Penetration  
Torque: 5 lb/in (0.6 Nm)  
DIRECTION  
1.30 (33.00)  
0.21 (33.00)  
at 12 CFM  
0.98 (24.90)  
0.20 (5.00)  
6.00 (152.40)  
Logic Connector(3)  
5.41 (137.40)X2  
for standard versions  
JST B10B-PHDSS  
A
A
Pin  
1
2
Function  
+Sense  
-Sense  
4.00 (101.60)  
3
4
5
6
Power Fail  
No Connection  
No Connection  
No Connection  
+Inhibit  
2.36 (60.00)  
C
L
A
A
7
8
9
10  
-Inhibit  
+5V Standby  
-5V Standby  
0.39 (10.00)X2  
(3)  
Logic Connector  
(3)  
Fan Connector  
For Current Share Versions -P  
JST B10B-PHDSS  
S3B-PH-KL(LF)  
Pin  
1
2
Function  
+12 V  
N/C  
Pin  
1
2
Function  
+Sense  
-Sense  
3
GND  
3
4
5
6
Power Fail  
No Connection  
Current Share  
Current Share  
+Inhibit  
Notes  
1. All dimensions in inches (mm).  
2. Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)  
7
8
9
10  
-Inhibit  
+5V Standby  
-5V Standby  
3. Fan connector mates with JST housing PHR-3 and SPH-002T-P0.5S crimp  
terminals or equivalent. Logic connector J301 mates with JST housing  
PHDR-10VS and SPHD-001T-P0.5 crimp terminals.  
www.xppower.com  
77  
AC-DC Power Supplies  
GSP500 Series  
Thermal Considerations - GSP500PSxx Models Only  
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must  
not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component  
(out of direct air flow). See below for component locations.  
Temperature Measurements (At Ambient 50 °C)  
Component  
T1 Coil  
Max Temperature °C  
120 °C  
L3 Coil  
120 °C  
Q7 Body  
Q102 Body  
C20  
120 °C  
120 °C  
105 °C  
C102  
105 °C  
--  
Service Life  
The estimated service life of the GSP500PSxx Series is determined by the cooling arrangements and load conditions experienced in the end  
application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a  
key capacitors with in the product when installed by the end application. The worst case of the two figures should be taken as the indicative  
service life in 24/7 operation.  
The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this  
temperature.  
Estimated Service Life vs Component Temperature  
70000  
Q102  
60000  
50000  
40000  
30000  
C20  
20000  
10000  
C102  
Q7  
0
105  
95  
85  
75  
65  
55  
C20 Temperature (°C)  
T1  
350000  
300000  
250000  
200000  
150000  
100000  
50000  
L3  
0
105  
95  
85  
75  
65  
55  
C102Temperature (°C)  
www.xppower.com  
12 April 16  

相关型号:

GSP500-20-3P208

可编程电源
TDK

GSP500-20-3P480

可编程电源
TDK

GSP500-30-3P208

可编程电源
TDK

GSP500-30-3P480

可编程电源
TDK

GSP500PS12-EF

AC-DC Regulated Power Supply Module,
XPPOWER

GSP500PS24-EF

AC-DC Regulated Power Supply Module,
XPPOWER

GSP500PS48

AC-DC Regulated Power Supply Module,
XPPOWER

GSP500PS48-EF

AC-DC Regulated Power Supply Module,
XPPOWER

GSP500V

Video Generator & Line Lock Circuit
ETC

GSP5A

Rectifier Diode, 1 Element, 1A, 600V V(RRM), Silicon,
GOOD-ARK

GSP60-170-3P208

Programmable Power Supplies
TDK

GSP60-170-3P400

Programmable Power Supplies
TDK