8 Watts  
xppower.com  
JCJ08 Series  
2:1 Input Range  
DIP-24 Metal Package  
Operating Temperature -40 ºC to +100 ºC  
Single & Dual Outputs  
Continuous Short Circuit Protection  
1500 VDC Isolation  
High Efficiency - Up to 85%  
Specification  
Input  
General  
Input Voltage Range  
• 12 V (9-18 VDC)  
24 V (18-36 VDC  
48 V (36-75 VDC)  
Efficiency  
Isolation  
• See tables  
• 1500 VDC Input to Output  
1000 VDC Input to Case  
1000 VDC Output to Case  
Input Current  
Input Filter  
• See table  
• Pi network  
Isolation Capacitance • 1200 pF max  
Input Reflected Ripple • 35 mA pk-pk through 12 µH inductor,  
Switching Frequency  
MTBF  
• 330 kHz typical  
5 Hz to 20 MHz  
• >0ꢁ9 MHrs to MIL-STD-217F  
Input Surge  
• 12 V models 25 VDC for 100 ms  
24 V models 50 VDC for 100 ms  
48 V models 100 VDC for 100 ms  
Environmental  
Operating Temperature • -40 ºC to +100 ºC, derate from 100ꢀ load  
at +60 /C to no load at +100 /C  
Output  
Case Temperature  
Storage Temperature  
Humidity  
• +100 ºC max  
• -40 ºC to +125 ºC  
• Up to 90ꢀ, non-condensing  
• Natural convection  
Output Voltage  
• See table  
Output Voltage Balance • 1ꢀ max, dual output models  
Cooling  
Minimum Load  
• No minimum load required  
• 1ꢀ max  
Initial Set Accuracy  
Start Up Delay  
EMC  
• <20 ms  
• <10 ms  
Emissions  
• EN55022 Class A conducted with external  
components - see application note  
Start Up Rise Time  
Line Regulation  
Load Regulation  
0ꢁ5ꢀ max  
ESD Immunity  
• EN61000-4-2,  
4 kV contact discharge Perf Criteria B  
0ꢁ7ꢀ for 3ꢁ3 V models , 0ꢁ5ꢀ for all  
other models, see note 2  
Radiated Immunity  
EFT/Burst  
• EN61000-4-3, 3 Vꢂm Perf Criteria A  
• EN61000-4-4, level 3 Perf Criteria B*  
• EN61000-4-5, level 3 Perf Criteria B*  
• EN61000-4-6, 3 Vrms Perf Criteria A  
• EN61000-4-8, 1 Aꢂm Perf Criteria A  
Cross Regulation  
5ꢀ on dual output models, see note 3  
Transient Response  
• <3ꢀ max deviation, recovery to within 1ꢀ  
in 250 µs for a 25ꢀ load change  
Surge  
Conducted Immunity  
Magnetic Field  
Ripple & Noise  
• 75 mV pk-pk, 20 MHz BW, with 1 µF  
ceramic capacitor, see note 4  
Overload Protection  
• >150ꢀ  
Short Circuit Protection Trip & restart (hiccup) with auto recovery  
* See note 5ꢁ  
Maximum Capacitive  
Load  
• See tables  
Temperature  
Coefficient  
• 0ꢁ02ꢂ/C max  
JCJ08  
Models and Ratings  
Input  
Voltage  
Output  
Voltage  
3ꢁ3 V  
Output  
Current  
2ꢁ000 A  
1ꢁ500 A  
0ꢁ665 A  
0ꢁ535 A  
0ꢁ800 A  
0ꢁ335 A  
0ꢁ265 A  
2ꢁ000 A  
1ꢁ500 A  
0ꢁ665 A  
0ꢁ535 A  
0ꢁ800 A  
0ꢁ335 A  
0ꢁ265 A  
2ꢁ000 A  
1ꢁ500 A  
0ꢁ665 A  
0ꢁ535 A  
0ꢁ800 A  
0ꢁ335 A  
0ꢁ265 A  
Input Current(1)  
No Load  
Maximum  
Capacitive Load  
3000 µF  
2200 µF  
470 µF  
Model  
Number  
Efficiency  
Full Load  
0ꢁ69 A  
0ꢁ76 A  
0ꢁ78 A  
0ꢁ80 A  
0ꢁ81 A  
0ꢁ79 A  
0ꢁ79 A  
0ꢁ34 A  
0ꢁ38 A  
0ꢁ39 A  
0ꢁ40 A  
0ꢁ41 A  
0ꢁ40 A  
0ꢁ39 A  
0ꢁ17 A  
0ꢁ19 A  
0ꢁ20 A  
0ꢁ20 A  
0ꢁ20 A  
0ꢁ20 A  
0ꢁ20 A  
20 mA  
20 mA  
20 mA  
20 mA  
20 mA  
20 mA  
20 mA  
15 mA  
15 mA  
15 mA  
15 mA  
15 mA  
15 mA  
15 mA  
15 mA  
15 mA  
15 mA  
15 mA  
15 mA  
15 mA  
15 mA  
80ꢀ  
82ꢀ  
85ꢀ  
83ꢀ  
82ꢀ  
84ꢀ  
84ꢀ  
80ꢀ  
82ꢀ  
85ꢀ  
84ꢀ  
82ꢀ  
83ꢀ  
85ꢀ  
80ꢀ  
82ꢀ  
84ꢀ  
84ꢀ  
82ꢀ  
85ꢀ  
85ꢀ  
JCJ0812S3V3  
JCJ0812S05  
JCJ0812S12  
JCJ0812S15  
JCJ0812D05  
JCJ0812D12  
JCJ0812D15  
JCJ0824S3V3  
JCJ0824S05  
JCJ0824S12  
JCJ0824S15  
JCJ0824D05  
JCJ0824D12  
JCJ0824D15  
JCJ0848S3V3  
JCJ0848S05  
JCJ0848S12  
JCJ0848S15  
JCJ0848D05  
JCJ0848D12  
JCJ0848D15  
5ꢁ0 V  
12ꢁ0 V  
15ꢁ0 V  
5ꢁ0 V  
12ꢁ0 V  
15ꢁ0 V  
3ꢁ3 V  
9-18 V  
18-36 V  
36-75 V  
220 µF  
1000 µF  
220 µF  
100 µF  
3000 µF  
2200 µF  
470 µF  
220 µF  
1000 µF  
220 µF  
5ꢁ0 V  
12ꢁ0 V  
15ꢁ0 V  
5ꢁ0 V  
12ꢁ0 V  
15ꢁ0 V  
3ꢁ3 V  
100 µF  
3000 µF  
2200 µF  
470 µF  
220 µF  
1000 µF  
220 µF  
5ꢁ0 V  
12ꢁ0 V  
15ꢁ0 V  
5ꢁ0 V  
12ꢁ0 V  
15ꢁ0 V  
100 µF  
Notes  
1. Input current measured at nominal input voltage.  
2. From 10% to 100% load.  
4. Measured with 20 MHz BW and 1 µF ceramic capacitor across output rails.  
5. External input capacitor required, Nippon Chemi-Con KY series, 220 µF/100 V  
or equivalent.  
3. When one output is set at 100% load and the other varied between 25% and  
100% load  
Mechanical Details  
All dimensions are in inches (mm)  
Weight: 0ꢁ04 lbs (20 g) approxꢁ  
24 Pin DIL Package - Nickel Coated Copper  
1.25  
(31.75)  
0.08  
(2.00)  
0.90  
(22.86)  
Pin Connections  
Pin  
2
Single  
-Vin  
Dual  
-Vin  
1
2
3
9
11  
DIA  
3
-Vin  
-Vin  
0.80  
(20.32)  
0.60  
(15.24)  
0.02  
Bottom View  
(0.50)  
9
No Pin  
Not Connected  
+Vout  
Common  
-Vout  
11  
14  
16  
22  
23  
23 22  
16 14  
+Vout  
Common  
+Vin  
-Vout  
0.10  
(2.54)  
+Vin  
+Vin  
+Vin  
Notes:  
1. Pin diameter: 0.02 0.002 (0.5 0.05)  
2. Pin pitch tolerance: 0.014 ( 0.35)  
3. Case Tolerance: 0.02 ( 0.5)  
0.40 (10.40)  
0.12 (3.05) Min.  
Application Notes  
Derating Curve  
Input Filter  
100  
80  
60  
40  
20  
0
+Vin  
+Vout  
L
DC/DC  
Converter  
C1  
LOAD  
-Vin  
-Vout  
-40  
-20  
0
40 50 60 70 80 90 100  
10 20 30  
Ambient Temperature (ºC)  
Model  
12 V  
L
C1  
12 µH  
12 µH  
12 µH  
100 µF, 100 V  
100 µF, 100 V  
100 µF, 100 V  
24 V  
48 V  
27-Nov-08  

相关型号:

JCJ0848S15

DC-DC Power Supplies
XPPOWER

JCJ0848S3V3

DC-DC Power Supplies
XPPOWER

JCJ1012D12

DC-DC Power Supplies
XPPOWER

JCJ1012D15

DC-DC Power Supplies
XPPOWER

JCJ1012S05

DC-DC Power Supplies
XPPOWER

JCJ1012S12

DC-DC Power Supplies
XPPOWER

JCJ1012S15

DC-DC Power Supplies
XPPOWER

JCJ1012S2V5

DC-DC Power Supplies
XPPOWER

JCJ1012S3V3

DC-DC Power Supplies
XPPOWER

JCJ1024D12

DC-DC Power Supplies
XPPOWER

JCJ1024D15

DC-DC Power Supplies
XPPOWER

JCJ1024S05

DC-DC Power Supplies
XPPOWER