JPP130PT09 [XPPOWER]
DC-DC Power Supplies; 直流 - 直流电源型号: | JPP130PT09 |
厂家: | XP POWER LIMITED |
描述: | DC-DC Power Supplies |
文件: | 总2页 (文件大小:307K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
130 Watts
xppower.com
JPP130 Series
•
•
•
•
•
•
•
High Power Density
Small Footprint
Up to Five DC Outputs
Wide Adjustment on Two Outputs
Short Circuit Protection with Auto Recovery
Power Fail Signal
Active Power Factor Correction
Specification
Input
General
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
• 90-264 VAC
Efficiency
Isolation
• 75% typical
• 47-63 Hz
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• 7.2 W/In3
• 2.10 A at 115 VAC, 1.10 A at 230 VAC
• 35 A at 115 VAC, 70 A at 230 VAC
• 0.98 typical
Power Density
Signals
• PFD = TTL Level (see note 5)
• 200 kHrs per MIL-STD-217F
MTBF
Output
Output Voltage
• See table
Environmental
Output Voltage Trim
Initial Set Accuracy
Minimum Load
• User adjustable (see note 3)
• 2% except V2: 3%
• See note 4
Operating Temperature • -10 ºC to +60 ºC, derate from 100% load
at +40 ºC to 50% load at +60 ºC
Cooling
• 10 CFM
Start Up Delay
• 2 s max
Operating Humidity
Storage Temperature
Shock
• 5-95% RH, non-condensing
• -40 ºC to + 85 ºC
Start Up Rise Time
Hold Up Time
• 12 ms max
• 15 ms min
• 20 G on 3 axis, 3 times each
Line Regulation
Transient Response
•
0.5% max
Vibration
• 10-55 Hz, 0.15 at 1 octave/min for
30 mins on each 3 axis
• 4% max. deviation, 500 µs recovery time
for a 25% load change
Ripple & Noise
• 65 mV for V1, 1% pk-pk on all other
outputs, 20 MHz BW
EMC & Safety
Emissions
• EN55022 FCC part 15 and VCCI level B
conducted and level A radiated
Overvoltage Protection • V1, V2 & V5 only: 112-132% of nominal
Temperature
Coefficient
• 0.04% / ºC
Harmonic Currents
Voltage Flicker
EFT/Burst
• EN61000-3-2
• EN61000-3-3
Remote Sense
• On 3.3 V output only: Compensates for
up to 0.5 V drop
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 3 V Perf Criteria A
• EN61000-4-8, 1 A/m Perf Criteria A
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
Safety Approvals
• UL60950, CSA C22.2 No. 60950,
EN60950, CE Mark LVD
JPP130
Models and Ratings
Output
Output
Output
V3(3)
Output
V4(3)
Output
V5(2, 3)
Model
Number
V1(3, 4)
V2
+12.0 V/6.0 A
+15.0 V/4.8 A
+24.0 V/3.0 A
+12.0 V/6.0 A
+15.0 V/4.8 A
+24.0 V/3.0 A
+12.0 V/6.0 A
+15.0 V/4.8 A
+24.0 V/3.0 A
+12.0 V/6.0 A
+15.0 V/4.8 A
+24.0 V/3.0 A
+12.0 V/6.0 A
+15.0 V/4.8 A
+24.0 V/3.0 A
+12.0 V/6.0 A
+15.0 V/4.8 A
+24.0 V/3.0 A
+12.0 V/6.0 A
+15.0 V/4.8 A
+24.0 V/3.0 A
+12.0 V/6.0 A
+15.0 V/4.8 A
+24.0 V/3.0 A
JPP130PD02
JPP130PD03
JPP130PD04
JPP130PT01
JPP130PT02
JPP130PT03
JPP130PT04
JPP130PT05
JPP130PT06
JPP130PT07
JPP130PT08
JPP130PT09
JPP130PQ01
JPP130PQ02
JPP130PQ03
JPP130PQ04
JPP130PQ05
JPP130PQ06
JPP130PQ07
JPP130PQ08
JPP130PQ09
JPP130PM01
JPP130PM02
JPP130PM03
+5.1 V/12.0 A
3.3 V/12.0 A
3.3 V/12.0 A
3.3 V/12.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
+5.1 V/12.0 A
-5.0 to -24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
3.3 V/12.0 A
3.3 V/12.0 A
3.3 V/12.0 A
3.3 V/12.0 A
3.3 V/12.0 A
3.3 V/12.0 A
-5.0 to -24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
-5.0 to -24.0 V/1.0 A
+5.1 V/12.0 A
+5.1 V/12.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
+5.0 to 24.0 V/1.0 A
3.3 V/12.0 A
3.3 V/12.0 A
3.3 V/12.0 A
Notes
1. Minimum 10 CFM required for 130 W operation.
2. V1 and V5 combined output power not to exceed 65 W; V2, V3 and V4 combined output power not to exceed 65 W; V3 and V4 combined output power
not to exceed 30 W.
3. Adjustable range: V1 and V5 are adjustable 10ꢀ, V3 and V4 can be trimmed 5ꢁ24 VꢂC and are factoryꢁset to 12 VꢂC nominal.
Accessible trim pots are assigned as VR1 for V1, VR2 for V5, VR3 for V3, VR4 for V4 and V2 is fixed.
VR3 and VR4 trim pots are SMꢂ types are located underneath PCB.
4. Minimum load of 0.8 A is required on V1 to regulate V5 where fitted.
5. PFꢂ = TTL low gives warning of at least 10 ms before V1 output drops below 95ꢀ of nominal. This signal also provides a minimum of 100 ms delay after
V1 is within regulation.
Mechanical Details
All dimensions are in inches (mm), tolerance: 0.02 ( 0.5) max
Weight: 0.71 lbs (320 g)
0.225 (5.72)
0.16 (4.0) Dia Mounting Hole (4 PLS)
PIN CONNECTIONS
Pin
1
P1
P2
V1
P3
-Sense (V5)
+Sense (V5)
PFD signal
Com
P4(1)
Live
V5
6
2
Neutral
Com
Com
3
-
-
-
-
Com
-
-
-
-
P2
4
V3 or N/C
V4 or N/C
V2 or N/C
5
-
DIRECTION
OF AIR FLOW
1
4
6
-
P3
P4
N
L
1
2
1
Note:
P1
1. P4 only applies to models which have an Output V5 in the
Models and Rating table.
Derating Curve
4.55 (115.6)
5.00 (127.0)
130
10 CFM
Forced-air Cooling
90
1.04 (26.4)
0.06 (1.60)
65 W
5 CFM
Forced-air Cooling
45 W
VR2 VR1
0.10 (2.54)
20
10 W
Convection Cooling
0
-10
P2 & P4 Connectors: Can accept 18-12 AWG electric wires.
0
10 20 30 40 50 60
P1 Mating Connector: Molex 09-50-3031 and 2878 series crimp terminals or equivalent.
P3 Mating Connector: Molex 22-01-1043 and 40445 series crimp terminals or equivalent.
Ambient Temperature (˚C)
04/04/05
相关型号:
©2020 ICPDF网 联系我们和版权申明