JTL3048D05 [XPPOWER]
30 Watts JTL Series; 30瓦JTL系列型号: | JTL3048D05 |
厂家: | XP POWER LIMITED |
描述: | 30 Watts JTL Series |
文件: | 总2页 (文件大小:291K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
xppower.com
30 Watts
JTL Series
•
•
•
•
•
•
•
4:1 Input Range
High Power Density
Single, Dual and Triple Outputs
High Efficiency ꢀ Up to 91%
Remote On/Off
1600 VDC Isolation
3 Year Warranty
Specification
Input
General
Input Voltage Range
Input Current
Input Reflected Ripple • 20 mA pk-pk through 12 µH inductor
Input Filter • Pi network
• 24 V (9-36 VDC), 48 V (18-75 VDC)
• See table
Efficiency
• See table
Isolation Voltage
• 1600 VDC Input to Output
1600 VDC Input to Case
1600 VDC Output to Case
Undervoltage Lockout • 24 V models: ON 8.6 V, OFF 7.9 V typical
Switching Frequency
Power Density
MTBF
• 330 kHz typical
• 37.5 W/in
• 320 kHrs min to MIL-HDBK-217F
at 25 °C, GB
48 V models: ON 17.8 V, OFF 16 V typical
3
Input Surge
• 24 V models 50 VDC for 100 ms
48 V models 100 VDC for 100 ms
Output
Output Voltage
Environmental
• See table
Output Voltage Trim
Minimum Load
•
10% on single outputs models only
Operating Temperature • -40 °C to +75 °C, see derating curve
• No minimum load required for single and
dual output models, 10% required on all
outputs for triple output models
Case Temperature
Cooling
• +105 °C max
• Convection-cooled
• 5-95% RH, non-condensing
Operating Humidity
Line Regulation
Load Regulation
•
0.2% max for single and dual output
models, 1.0% main, 5% auxiliary for
triple output models
Storage Temperature • -40 °C to +125 °C
• Single output models: 0.5% max
Dual output models: 1% max
balanced outputs
EMC
Triple output models: 1% max main, 5%
auxiliaries
5% for dual and triples output (see note 2)
1% ( 5% for triple auxiliaries)
Emissions
• EN55022, class A conducted &
radiated with external components,
see application note
Cross Regulation
Setpoint Accuracy
Start Up Time
•
•
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-4-2, level 3, Perf Criteria A
• EN61000-4-3 10 V/m Perf Criteria A*
• EN61000-4-4 level 3, Perf Criteria A*
• 30 ms typical
Ripple & Noise
• 100 mV or 1% pk-pk, whichever is greater
single & dual output models, 50/75 mV
pk-pk main/auxiliary outputs of triple output
models, 20 MHz bandwidth (see note 3)
Surge
• EN61000-4-5 installation class 2,
Perf Criteria A
Transient Response
Temp. Coefficient
• 3% max deviation, recovery to within
1% in <250 µs for a 25% load change
• 0.02%/°C
Conducted Immunity
Magnetic Field
• EN61000-4-6 10 V/rms, Perf Criteria A
• EN61000-4-8 1 A/m, Perf Criteria A
Overvoltage Protection • 3.3 V models: 3.9 V typical
5 V models: 6.2 V typical
*External input capacitor required 220 µF/250 V
12 V models: 15 V typical
15 V models: 18 V typical
5 V models: 6.2 V typical
12 V models: 15 V typical
15 V models: 18 V typical
Overload Protection
• >150% of full load
Short Circuit Protection • Trip & restart (hiccup mode), auto recovery
Overtemperature
Protection
• 115 °C typical
Remote On/Off
• On = Logic High (>3.0) or Open
Off = Logic Low (<1.2 V) or short pin 2 to 3
Maximum Capacitive
Load
• See table
JTL30
Models and Ratings
Input Current(1)
No Load
Maximum
Capacitive Load
Input Voltage
Output Voltage
Output Current
Efficiency
Model Number
Full Load
1185 mA
1420 mA
1436 mA
1420 mA
1437 mA
1453 mA
1437 mA
1287 mA
1279 mA
1440 mA
1431 mA
593 mA
702 mA
718 mA
710 mA
710 mA
718 mA
718 mA
663 mA
640 mA
712 mA
707 mA
3.3 V
5.0 V
12.0 V
15.0 V
5.0 V
12.0 V
15.0 V
7.50 A
6.00 A
2.50 A
2.00 A
3.00 A
1.25 A
1.00 A
60 mA
100 mA
30 mA
30 mA
120 mA
30 mA
40 mA
80 mA
90 mA
100 mA
110 mA
50 mA
60 mA
30 mA
30 mA
70 mA
30 mA
40 mA
50 mA
50 mA
60 mA
50 mA
20000 µF
14000 µF
2000 µF
2000 µF
3000 µF
1300 µF
1300 µF
89%
91%
90%
91%
90%
89%
89%
89%
89%
89%
90%
89%
91%
90%
90%
91%
90%
90%
89%
89%
91%
90%
JTL3024S3V3
JTL3024S05
JTL3024S12
JTL3024S15
JTL3024D05
JTL3024D12
JTL3024D15
JTL3024T0312
JTL3024T0315
JTL3024T0512
JTL3024T0515
JTL3048S3V3
JTL3048S05
JTL3048S12
JTL3048S15
JTL3048D05
JTL3048D12
JTL3048D15
JTL3048T0312
JTL3048T0315
JTL3048T0512
JTL3048T0515
9-36 VDC
+3.3 V, 12.0 V
+3.3 V, 15.0 V
+5.0 V, 12.0 V
+5.0 V, 15.0 V
3.3 V
5.00 A, 0.42 A
5.00 A, 0.33 A
4.00 A, 0.42 A
4.00 A, 0.33 A
7.50 A
15000, 220 µF
15000, 220 µF
8000, 220 µF
8000, 220 µF
20000 µF
5.0 V
12.0 V
15.0 V
5.0 V
12.0 V
15.0 V
6.00 A
2.50 A
2.00 A
3.00 A
1.25 A
1.00 A
14000 µF
2000 µF
2000 µF
3000 µF
18-75 VDC
1300 µF
1300 µF
15000, 220 µF
15000, 220 µF
8000, 220 µF
8000, 220 µF
+3.3 V, 12.0 V
+3.3 V, 15.0 V
+5.0 V, 12.0 V
+5.0 V, 15.0 V
5.00 A, 0.42 A
5.00 A, 0.33 A
4.00 A, 0.42 A
4.00 A, 0.33 A
Notes
1. Input current specified at nominal 24 V or 48 V input.
3. Measured with 1 µF ceramic capacitor across output rails.
4. For heatsink option add ‘-HK’ to the end of the part number.
2. Cross regulation for duals is 5% when one output is at 100% and the other is
varied between 25% and 100%. Cross regulation for triples is 5% when main
output and one auxiliary is at 25% and the other is varied between 25% and 100%.
Mechanical Details
Optional heatsink (-HK)
1.00 (25.4)
0.20
0.30
0.10
0.40
0.10
0.64
0.40
0.40
PIN CONNECTIONS
(5.08)
(7.62)
0.30
(2.54)
(2.54)
(10.16)
(16.3)
(10.16)
0.10
(10.16)
(7.62)
(2.54)
Pin
1
2
3
4
5
6
7
Single
+Vin
Dual
+Vin
-Vin
Triple
+Vin
-Vin
4
5
6
7
4
5
6
0.10
(2.54)
0.10
-Vin
(2.54)
Dia.
0.04
Dia. 1.0
(0.04)
Dia. 1.0
(0.04)
0.5
Dia. 1.0
(0.04)
Dia. 1.0
(0.04)
Remote On/Off Remote On/Off Remote On/Off
(0.02)
(1.00)
+Vout
-Vout
Trim
+Vout
Com
-Vout
+Vout 2
-Vout 3
Com
1.80
Bottom View
Bottom View
2.00
2.00
(45.72)
(50.80)
(50.80)
Triple Output Models
Single & Dual
+Vout 1
Output Models
Dia.
0.04
Notes
Dia. 1.0
(0.04)
Dia. 1.0
(0.04)
Dia. 1.0
Dia. 1.0
(0.04)
1
0.5
0.10
1. All dimensions are in inches (mm).
2. Weight: 0.07 lbs (30 g) approx
3. Pin diameter: 0.04 0.002 (1.0 0.05)
4. Pin pitch tolerance: 0.014 ( 0.35)
5. Case tolerance: 0.02 ( 0.5)
(1.00)
(0.04)
1
(0.02)
(2.54)
2
3
2
3
0.30
0.20
0.20
(5.08)
min
(7.62)
(5.08)
0.10
(2.54)
Thermal Pad
0.20
5.08)
0.10
(2.54)
0.60 (15.24)
0.50 (12.7)
Application Notes
Derating Curve
Input Filter
100%
+Vin
+Vout
+
without heat-sink
with heat-sink
12 µH
75%
50%
DC/DC
Converter
100 µF,
100 V
LOAD
25%
-Vin
Com
-
50
75
80
-40
-20
0
20
40
60
100
Ambient Temperature (°C)
470 pF, 2Kv
External Output Trim
6
6
Output can be externally
trimmed using this method.
R trim-up
5
R trim-down
4
Contact sales for details.
20-Aug-13
相关型号:
©2020 ICPDF网 联系我们和版权申明