LCW100 Series
AC-DC POWER SUPPLIES
CONVECTION
COOLED
100W
The LCW series of regulated output convecꢀon cooled AC-DC power supplies are
designed to provide a cost effecꢀve soluꢀon for industrial electronics, technology and
household applicaꢀons. Features include wide range AC input from 85-305VAC, output
voltage adjustment, low stand-by power consumpꢀon, output short circuit protecꢀon, over
current and over voltage protecꢀon. Applicaꢀons include auxiliary power sources, security
installaꢀons, lighꢀng control, smart home or office control systems, ꢀckeꢀng and vending
applicaꢀons.
Features
• 100W convecꢀon cooled
Applicaꢀons
• Integrated connector cover
• ITE, industrial & household approvals
• Class B conducted & radiated emissions
• Input voltage range 85-305VAC
• Regulated single outputs from 5.0V to 48VDC
• Output voltage trim ±10%
Technology
Household
Appliances
Industrial
Roboꢀcs
Electronics
Dimensions
5.079” x 3.819” x 1.181” (129.0 x 97.0 x 30.0mm)
• Efficiency to 90%
• Short circuit, overvoltage & overload protecꢀon
• Conformal coaꢀng opꢀon
• -30°C to +70°C operaꢀng temperature
• 3 year warranty
Models & Raꢀngs
Output Voltage
Adjustment Range(4)
Ripple & Noise
pk to pk(1)
Maximum
Model Number(3)
Output Current
Efficiency(2)
Power
Capaciꢀve Load
Nominal
5.0V
LCW100US05
LCW100US12
LCW100US15
LCW100US24
LCW100US36
LCW100US48
4.5 - 5.5V
10.8 - 13.2V
13.5 - 16.5V
21.6 - 26,4V
32.4 - 39.6V
43.2 - 52.8V
18.0A
8.5A
7.0A
100mV
120mV
120mV
150mV
200mV
200mV
85%
87%
87%
89%
89%
90%
10000μF
6800μF
3300μF
2200μF
1000μF
470μF
90W
100W
100W
100W
100W
100W
12.0V
15.0V
24.0V
36.0V
48.0V
4.5A
2.8A
2.3A
Notes:
1. Ripple & noise measured with 20MHz bandwidth and 47μF electrolyꢀc capacitor in parallel with 0.1μF ceramic capacitor.
2. Typical efficiencies measured at 230VAC full load.
3. Add suffix -E to model number to specify conformal coaꢀng opꢀon, MOQ applies, please contact sales.
4. Output power raꢀng must not be exceeded.
AC-DC POWER SUPPLIES
LCW100 Series
Input
Characterisꢀc
Minimum
Typical
Maximum
Units
Notes & Condiꢀons
85
115/230
305
VAC
Derate output power linearly from 100% at 115VAC to 80% at 85VAC
Alternative input. Not to be used in addition to AC input. DC input not
included in safety approvals, external DC rated fuse required. Derate
output power linearly from 100% at 163VDC to 80% at 120VDC
Input Voltage - Operating
120
47
430
VDC
Input Frequency
50/60
63
3.0
1.5
0.5
Hz
A
115VAC
230VAC
Input Current - Full Load
No Load Input Power
Inrush Current
W
A
35
65
115VAC cold start at 25°C ambient
230VAC cold start at 25°C ambient
277VAC/50Hz (Typ)
Earth Leakage Current
Input Protection
0.75
mA
T6.3A/300VAC Internal fuse fitted in line
Output
Characterisꢀc
Minimum
Typical
Maximum
Units
Notes & Condiꢀons
Output Voltage
4.5
52.8
VDC
See Models & Ratings table
±2
±1
LCW100US05
Full load
Initial Set Accuracy
%
All other models
Voltage Adjustment
Minimum Load
Start Up Delay
±10
%
A
0
No minimum load required
115/230VAC full load
115VAC
230
10
ms
Hold Up Time
ms
55
230VAC
Drift
±0.03
%
%
After 20 minutes warm up, 230VAC, 0°C to 50°C
100-264VAC, full load
Line Regulation
±0.5
±1.0
±0.5
LCW100US05
0-100%
Load Regulation
%
%
load
All other models
Recovery within 1% in less than 5ms for a 50-75% and 75-50% load
step
Transient Response
10
Ripple & Noise
mV pk-pk
%
See Models & Ratings table
Full load 5ms recovery
LCW100US05
Over/Undershoot
10
7. 5
19.2
24.0
38.4
57.6
LCW100US12
LCW100US15
Hiccup mode, auto recovery
LCW100US24
Overvoltage Protection
VDC
LCW100US36
60.0
160
5
LCW100US48
Overload Protection
110
%
Nominal output current, auto recovery
Temperature Coefficient
Short Circuit Protection
±0.03
%/°C
Continuous, hiccup with auto recovery
2
AC-DC POWER SUPPLIES
LCW100 Series
General
Characterisꢀc
Minimum
Typical
Maximum
Units
Notes & Condiꢀons
Efficiency
88
%
230VAC Full load (see Models & Ratings table)
4000
2000
1250
VAC
VAC
VAC
kHz
Isolation: Input to Output
Input to Ground
Class I construction
Output to Ground
Switching Frequency
Power Density
65
4.60
W/in3
Mean Time Between Failure
300
khrs
MIL-HDBK-217F, Notice 2 25°C GB
LCW100US05
0.72 (325)
0.67 (305)
Weight
lb(g)
All other models
Case Material
Aluminium chassis with vented galvanized steel cover
Acrylic resin, UL94V-0 rated, certified (UL No. E351072), minimum 30μm coating thickness. Add suffix -E to part number
Conformal Coating Option
Environmental
Characterisꢀc
Minimum
Typical
Maximum
Units
Notes & Condiꢀons
Operating Temperature
Storage Temperature
Cooling
-30
-40
+70
+85
°C
°C
See derating curve
Natural convection
5
Humidity
90
%RH
m
Non-condensing
Operating Altitude
Shock and Vibration
5000
Tested according to EN60068-2-27, 10 - 500Hz, 5g (1H) for each X,Y and Z plane
EMC: Emissions
Phenomenon
Standard
Test Level
Notes & Condiꢀons
Conducted
Radiated
EN55032
EN55032
Class B
Class B
EMC: Immunity
Phenomenon
Standard
Test Level
Criteria
Notes & Condiꢀons
ESD Immunity
Radiated Immunity
EFT
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
3
A
A
A
A
A
A
B
A
A
A
B
Contact ±6kV/Air ±8kV
3
10V/m
3
±2kV
Surge
Installation class 4
3
Line to line ±2kV, line to ground ±4kV
10Vrms
Conducted
Dip. 100% (0VAC), 10ms
Dip. 100% (0VAC), 20ms
Dip. 60% (88VAC), 200ms
Dip. 30% (154VAC), 500ms
Dip. 20% (176VAC), 5000ms
Int. 100% (0VAC), 5000ms
Dips
EN61000-4-11
Interruptions
3
ACꢁDC POWER SUPPLIES
LCW100 Series
Safety Approvals
Cerꢀꢁcaꢀon
Standard
Notes & Condiꢀons
UL
UL62368-1
InformationTechnology
EN
EN62368-1, EN60335, EN61558
Meets all applicable directives
Meets all applicable legislation
InformationTechnology and Household
CE
UKCA
Applicaꢀon Notes
Temperature Deraꢀng
100
90
80
70
60
(5V)
(12V, 15V, 24V, 36V, 48V)
50
40
30
20
-30
-20
-10
0
10
30
Ambient temperature (°C)
20
40 45 50
60
70
4
AC-DC POWER SUPPLIES
LCW100 Series
Mechanical Details
4.823 (122.5)
0.177 (4.5)
0.138 (3.5)
V Out Adj.
Power
‘ON’ LED
4.724 (120.0)
0.256 (6.5)
0.138 (3.5)
3x M3 x 0.5 Thread
Max. Penetraꢀon = 5mm
3.819 (97.0)
1.260 (32.0)
2x 3.031 (77.0)
2 x 3.071 (78.0)
Pin-Out
Funcꢀon
Pin
1
2
3
4
5
6
7
AC(L)
AC(N)
GND
-Vo
-Vo
2x M3x0.5 Thread
Max. Penetraꢀon = 3mm
+Vo
+Vo
Connector torque: M3.5, 0.4Nm
5.079 (129.0)
Notes:
1. All dimensions are in inches (mm).
2. Tightening torque: M3.5, 0.4Nm fixings
3. General tolerances: ±0.039 (±1.00)
4. Chassis must be connected to protecꢀve earth.
5. Use 22-14 AWG wire range for connector
5
12 Aug 2021
相关型号:
©2020 ICPDF网 联系我们和版权申明