DC-DC Converter  
RDE20 Series  
20 Watts  
• Regulated Single & Dual Output  
xxx Series  
• 24-48 VDC & 72-110 VDC nominal inputs for Railway Applications  
• 3000 VDC Isolation  
• High Efficiency  
• EN50155 Certified for Railway Applications  
• EN50121-3-2 with External Components  
• Remote On/Off  
• Output Voltage Trim 10%  
• Operating Temperature -40 °C to +100 °C  
• Full Power to +55 °C  
Dimensions:  
RDE20:  
• 3 Year Warranty  
1.0 x 1.0 x 0.41” (25.4 x 25.4 x 10.4 mm)  
The RDE20 series provides a comprehensive wide DC input voltage range covering all requirements of the railway standard EN50155. The product  
features a robust design tested to railway standards and includes a remote on /off function, output voltage trimming, protection against short  
circuit, undervoltage lockout, overload and overvoltage.  
Models & Ratings  
Input current(1)  
Maximum  
capacitive load  
7000 µF  
5000 µF  
850 µF  
Input voltage  
Output voltage  
Output current  
Efficiency  
Model number  
No load  
Full load  
3.3 V  
5.0 V  
4500 mA  
4000 mA  
1670 mA  
1330 mA  
2000 mA  
833 mA  
711.20 mA  
946.96 mA  
936.33 mA  
925.92 mA  
968.99 mA  
925.92 mA  
925.92 mA  
156.97 mA  
206.61 mA  
211.41 mA  
211.41 mA  
216.45 mA  
208.98 mA  
208.98 mA  
87%  
88%  
89%  
90%  
86%  
90%  
90%  
86%  
88%  
86%  
86%  
84%  
87%  
87%  
RDE2024S3V3  
RDE2024S05  
RDE2024S12  
RDE2024S15  
RDE2024D05  
RDE2024D12  
RDE2024D15  
RDE20110S3V3  
RDE20110S05  
RDE20110S12  
RDE20110S15  
RDE20110D05  
RDE20110D12  
RDE20110D15  
12.0 V  
15.0 V  
5.0 V  
13-70 VDC  
10 mA  
700 µF  
1000 µF  
680 µF  
12.0 V  
15.0 V  
3.3 V  
666 mA  
470 µF  
4500 mA  
4000 mA  
1670 mA  
1330 mA  
2000 mA  
833 mA  
7000 µF  
5000 µF  
850 µF  
5.0 V  
12.0 V  
15.0 V  
5.0 V  
42-176 VDC  
10 mA  
700 µF  
1000 µF  
680 µF  
12.0 V  
15.0 V  
666 mA  
470 µF  
Notes  
1. Input current measured at nominal input voltage.  
2. For heatsink add suffix ‘-HK’, e.g. RDE2024S15-HK  
Mechanical Details  
Optional  
Heatsink (-HK)  
0.4  
0.4  
0.41  
(10.4)  
Pin Connections  
Pin Single Output Dual Output  
(10.16) (10.16)  
1.0  
(25.4)  
1.0  
0.02  
(0.5)  
(25.4)  
0.66  
(16.8)  
1
2
3
4
5
6
+Vin  
-Vin  
Control  
+Vout  
Trim  
+Vin  
-Vin  
Control  
+Vout  
Com  
1.0  
(25.4)  
0.6  
(15.24)  
0.8  
Bottom View  
Top View  
1.0 (25.4)  
ø0.04  
(20.32)  
(1.0)  
-Vout  
-Vout  
Notes  
1. All dimensions are in inches (mm)  
0.24  
(6.0)  
1.0  
(25.4)  
0.2  
(5.08)  
1.0  
(25.4)  
0.3  
(7.62)  
www.xppower.com  
1
DC-DC Converter  
RDE20 Series  
Input  
Characteristic  
Minimum  
Typical  
Maximum  
70  
Units  
Notes & Conditions  
13  
42  
24 V, 37.5 V, 48 V nominal inputs  
72 V, 96 V & 110 V nominal inputs  
Input Voltage Range  
Input Filter  
VDC  
176  
Internal Pi type  
100  
185  
RDE2024 series  
Input Voltage Surge  
VDC for 100 ms  
RDE20110 series  
OFF at <11.6 V, ON at 12.3 V  
OFF at <38.4 V, ON at 40.5 V  
RDE2024 series  
Undervoltage Lockout  
RDE20110 series  
ON at 3.0 VDC to 12.0 VDC or open circuit  
Positive logic reference to -Vin (pin 2)  
Remote On/Off  
(Positive Logic)  
OFF at 0 VDC to 1.2 VDC or short pin 2 to pin 3  
3
Standby Current  
mA  
When module inhibited  
Output  
Characteristic  
Output Voltage  
Output Trim  
Minimum  
Typical  
Maximum  
Units  
VDC  
%
Notes & Conditions  
3.3  
30  
10  
See Models and Ratings table  
Single output models only  
Initial Set Accuracy  
Minimum Load  
Line Regulation  
Load Regulation  
1.0  
%
At full load  
A
No minimum load required  
0.5  
%
From minimum to maximum input at full load  
From 0 to full load. Single Output/Dual Output  
0.5/ 1.0  
%
On dual output models when one load is varied between  
25% and 100% and other is fixed at 100%  
Cross Regulation  
5.0  
%
Recovery within 1% in less than 250 µs for a 25% load  
change.  
Transient Response  
3
5
% deviation  
Ripple & Noise  
75  
mV pk-pk  
20 MHz bandwidth. Measured using external 10 µF MLCC  
Overvoltage Protection  
Overload Protection  
120  
170  
%
%
Short Circuit Protection  
Maximum Capacitive Load  
Temperature Coefficient  
Continuous trip & restart (hiccup mode), with auto recovery  
See Models and Ratings table  
0.02  
%/˚C  
General  
Characteristic  
Minimum  
84  
Typical  
Maximum  
Units  
%
Notes & Conditions  
See Models and Ratings table  
60 s functional isolation  
At 3 kVDC  
Efficiency  
90  
Isolation: Input to Output  
Isolation Resistance  
Isolation Capacitance  
Switching Frequency  
Power Density  
3000  
VDC  
Ω
9
10  
2000  
pF  
330 / 245  
kHz  
RDE2024 / 110 series  
3
48.8  
W/in  
Mean Time Between Failure  
Case Material  
190  
khrs  
MIL-HDBK-217F, +25 °C GB  
Copper Case, Non conductive black plastic base, UL94V-0 rated  
Epoxy UL94V-0  
Potting Material  
Fire Protection  
Designed to meet EN45545-2  
PCB Pin Material  
ø1.0 mm brass, solder coated  
Lead Free Reflow Solder Process IPC JEDEC J-STD 020D.1. 260 °C max. 1.5 mm from case. 10 s max.  
0.041 (19.0)  
Standard  
Weight  
lb (g)  
0.048 (22.0)  
With heatsink  
www.xppower.com  
2
DC-DC Converter  
RDE20 Series  
Environmental  
Characteristic  
Minimum  
Typical  
Maximum  
+100  
Units  
°C  
Notes & Conditions  
Operating Temperature  
Maximum Case Temperature  
-40  
See derating curve  
+105  
°C  
13  
Without heatsink  
With heatsink  
Thermal Impedance to Air  
°C/W  
°C  
12  
Storage Temperature  
Altitude  
-55  
+125  
95  
5000 m operation  
Humidity  
%RH  
Non-condensing  
Cooling  
IEC/EN 60068-2-1  
IEC/EN 60068-2-2  
IEC/EN 60068-2-30  
IEC/EN 61373  
Dry Heat  
Damp Heat  
Shock & Vibration  
EMC: Emissions  
Phenomenon  
Standard  
Test Level  
Notes & Conditions  
Railway Equipment  
EN50121-3-2  
Conducted and Radiated  
EMC: Immunity  
Phenomenon  
Standard  
Test Level  
Criteria  
Notes & Conditions  
Electromagnetic compatibility for rolling stock  
apparatus  
Railway Equipment  
EN50121-3-2  
ESD  
EN50121-3-2  
EN50121-3-2  
8 kV air discharge, 6 kV contact  
20 V/m  
A
A
Radiated  
With external capacitor  
Suggested parts are  
24V: CHEMI-CON KY 330 µF/100 V  
110V: BXF SERIES 100 µF/250 V in parallel  
EFT/Burst  
Surge  
EN50121-3-2  
EN50121-3-2  
2 kV  
2 kV  
A
A
Conducted  
EN50121-3-2  
EN61000-4-8  
10 V rms  
100 A/m  
A
A
See application note  
Magnetic Fields  
Safety Approvals  
Safety Agency  
Safety Standard  
Notes & Conditions  
IEC  
IEC60950-1/IEC62368-1  
ITE  
Safety Agency  
Safety Standard  
Notes & Conditions  
EN  
EN50155  
Railway Applications, Electronic Equipment used on Rolling Stock  
www.xppower.com  
3
DC-DC Converter  
RDE20 Series  
Application Notes  
Remote On/Off - Single Output  
Remote On/Off - Dual Output  
1 +Vin  
+Vout 4  
1 +Vin  
+Vout 4  
5
Load  
3 Ctrl  
Load  
Common  
3 Ctrl  
Load  
2 -Vin  
-Vout 6  
2 -Vin  
-Vout 6  
Positive logic. Module turns on with logic high. Logic low turns module off. On/Off is enabled by an external switch between the control pin 3 and  
-Vin pin 2, e.g. open collector or drain. If the Remote On/Off is not used leave pin 3 floating.  
Output Voltage Trim - Single Output Models Only  
EMC - 110 V Input Models Only  
L1  
1 +Vin  
+Vout 4  
+Vout 4  
Rd  
Ru  
Trim down  
Trim up  
Trim 5  
Load  
2 -Vin  
-Vout 6  
-Vout 6  
C1 x 6  
(MLCC type)  
C1  
1 µF, 250 V  
L1  
12 µH  
Not required for RDE2024 series  
Trim Tables  
3.3 V  
5 V  
12 V  
15 V  
3.3 V  
5 V  
12 V  
15 V  
Trim Down %  
Trim Up%  
Rd (kΩ)  
Ru (kΩ)  
1
2
3
4
5
6
7
8
9
817.535  
362.230  
215.448  
142.957  
99.747  
71.057  
50.622  
35.326  
23.448  
13.957  
117.886  
61.634  
38.388  
25.688  
17.684  
12.179  
8.159  
5.096  
2.683  
0.735  
345.033  
164.830  
98.862  
64.647  
43.707  
29.571  
19.386  
11.699  
5.692  
174.366  
91.104  
56.589  
37.706  
25.796  
17.598  
11.611  
7.047  
1
2
3
4
5
6
7
8
9
567.584  
263.172  
158.473  
105.497  
73.508  
52.096  
36.760  
25.235  
16.257  
9.066  
616.020  
221.402  
131.336  
91.426  
68.900  
54.432  
44.353  
36.930  
31.235  
26.727  
1015.590  
448.881  
280.558  
199.789  
152.361  
121.162  
99.078  
82.625  
69.892  
59.745  
661.510  
231.250  
134.015  
91.042  
66.818  
51.270  
40.445  
32.475  
26.362  
21.524  
3.453  
0.548  
10  
0.867  
10  
Derating Curve  
100%  
With heat-sink  
75%  
Without heat-sink  
50%  
25%  
55  
-40  
-20  
0
20  
40 59 60  
80  
100 120  
Ambient Temperature (ºC)  
www.xppower.com  
07 June 19  

相关型号:

RDE20110D15

DC-DC Converter
XPPOWER

RDE20110S05

DC-DC Converter
XPPOWER

RDE20110S12

DC-DC Converter
XPPOWER

RDE20110S15

DC-DC Converter
XPPOWER

RDE20110S3V3

DC-DC Converter
XPPOWER

RDE2024D05

DC-DC Converter
XPPOWER

RDE2024D12

DC-DC Regulated Power Supply Module,
XPPOWER

RDE2024D15

DC-DC Regulated Power Supply Module,
XPPOWER

RDE2024S05

DC-DC Converter
XPPOWER

RDE2024S12

DC-DC Converter
XPPOWER

RDE2024S15

DC-DC Converter
XPPOWER

RDE2024S3V3

DC-DC Converter
XPPOWER