SLM300PS24-T [XPPOWER]
Industrial (SL) & Medical (SLM) Versions;型号: | SLM300PS24-T |
厂家: | XP POWER LIMITED |
描述: | Industrial (SL) & Medical (SLM) Versions |
文件: | 总2页 (文件大小:166K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
300-600 Watts
xppower.com
SL & SLM Series
•
•
•
•
•
•
•
Industrial (SL) & Medical (SLM) Versions
Output Voltages from 12 V to 96 V
Power Factor Corrected
Remote On/Off
Current Share
Power Fail Signal
Overtemperature Protection
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC (125-360 VDC)
Efficiency
Isolation
• 85% typical
• 44-66 Hz
• 6000 VDC Input to Output
(Y caps disconnected)
2200 VDC Input to Ground
2200 VDC Output to Chassis
• 300 W models: 4.4 A at 90 VAC
1.8 A at 230 VAC
600 W models: 8.9 A at 90 VAC
3.5 A at 230 VAC
Switching Frequency
Signals
• 30-35 kHz PFC, 45-55 kHz PWM
Inrush Current
Power Factor
• 100 A at 230 VAC
• 0.9 typical
• AC OK - TTL compatible signal is high
with reference to 0 V when AC is OK
MTBF
• 105 kHrs typical per MIL-HDBK-217E
at +20 ˚C. Consult office for each model
Earth Leakage Current • SL models: <2.5 mA at 264 VAC/50 Hz
SLM models: <100 µA at 264 VAC/50 Hz
Input Protection
• 10 A HRC fuse
Environmental
Output
Operating Temperature • -20 ˚C to +70 ˚C, derate from +40 ˚C
to 50% power at +70 ˚C
Output Voltage
• See table
• See table
Operating Humidity
Storage Temperature
Operating Altitude
Shock
• 90% RH, non-condensing
• -25 ˚C to +85 ˚C
• 3000 m
Output Voltage Trim
Initial Set Accuracy
Minimum Load
•
1% max
• No minimum load required
• 600 ms max
• Non operating. 100 mm drop on
to chassis face
Start Up Delay
Start Up Rise Time
Hold Up Time
• 150 ms max
Vibration
• Operating 5-50 Hz 0.05 mm pk-pk,
50-100 Hz 0.025 mm pk-pk
• 18 ms min
Line Regulation
Load Regulation
Transient Response
• <0.5% V min to V max
• <2.0% for a 0-100% load change
Airflow Direction
• Where fitted fans blow air into the unit
• 2% max deviation, recovery to within
0.25% in 1 ms for a 10% load change
EMC & Safety
Emissions
• EN55022, level B conducted
EN55022, level A radiated
Ripple & Noise
• 1% pk-pk max, 20 MHz BW
Overvoltage Protection • 120% approx Vnom
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-3-2, class A
Overtemperature
Protection
• Fitted to 600 W models only,
recycle mains to reset
• EN61000-3-3
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, level 3 Perf Criteria A
Overload Protection
• 110% typical, constant current
Short Circuit Protection • Constant current
Temperature
Coefficient
• 0.02%/˚C
Surge
Conducted Immunity
Dips & Interruptions
Remote On/Off
• Output inhibited by shorting
ROF pin to 0 V
• EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Perf Criteria A, B, B
Current Share
• Allows up to 5 units to share within 5%
Safety Approvals
• SL: UL60950, CSA22.2 No.60950
SLM: UL2601-1, CSA C22.2 No.60601-1
SL & SLM Series
Model Numbering
No. of
Outputs
Power
Inputs
Outputs
Style
Options
(Watts)(1)
-C = Cover
-D = ORing Diode(2)
-E = Conformal Coating
-M = Ruggedisation
-N = Temperature
Compensation
12 = 12 V
24 = 24 V
48 = 48 V
60 = 60 V
C1 = 96 V
SL
SLM
=
=
Standard
Medically
Approved
300
600
S = Single
P = PFC
-T = Overtemperature
Protection
EXAMPLE:
SL 300
P S 24
-
C
SL = Standard
300 = Power
C = Safety Cover Fitted
24 = Output 24 VDC
S = Single Output
P = PFC Input
Notes
1. 300 W models are convection cooled. 600 W models are fan cooled.
2. Not available on 12 V output.
Models and Ratings
Output Current
Nominal Output
OVP Setting
Output Voltage Trim
Code
Voltage(2,3)
Typical(1)
300 W
25.0 A
12.0 A
8.0 A
6.0 A
5.0 A
600 W
50.0 A
25.0 A
16.5 A
12.5 A
10.0 A
6.0 A
12 V
24 V
36 V
48 V
60 V
96 V
11-14 V
22-29 V
33-42 V
44-57 V
55-70 V
88-114 V
15.3 V
30.7 V
45.9 V
61.2 V
76.5 V
127.5 V
12
24
36
48
60
C1
3.0 A
Notes
1. Overvoltage protection is by the inverter shutdown method and can only be reset by disconnecting the input voltage.
2. Output characteristic constant voltage - constant current type, ideal for non-linear loads.
3. Other output voltages available, consult sales for details.
Mechanical Details
All dimensions are in inches (mm)
Weight: 300 W models - 3.75 lbs (1.7 kg)
600 W models - 4.19 lbs (1.9 kg)
600 W
2.77 (71.0)
300 W
4.95 (127.0)
4.33 (111.0)
REMOTE ON/OFF
POWER SHARE
OUTPUT
AC FAIL SIGNAL
2.61 (67.0)
A
A
+V+V+V -V -V -V
INTERNAL FAN
600 W ONLY
Input connectors:
0.37” (9.5mm) pitch M4 barrier block.
Signals:
3 X 0.04” (3 X 1.0mm) pins 1.0” (25.4mm) pitch
(ROF, power share and AC fail).
LINE
NEUTRAL
EARTH
Fixings (ref ‘A’): M3 ISO Metric
(Screws must not penetrate unit by more than
0.20” (5.0mm).
A
A
INPUT
17-Apr-07