VCE40US15 [XPPOWER]
AC-DC Power Supplies;型号: | VCE40US15 |
厂家: | XP POWER LIMITED |
描述: | AC-DC Power Supplies |
文件: | 总4页 (文件大小:643K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AC-DC Power Supplies
VCE40 Series
40 Watts
• 85 to 305VAC input
• Single outputs from 3.3 to 48VDC
• PCB mount
• Encapsulated & open frame
• ITE & household appliance approvals
• EN55035 immunity standard
• Class II
• Low cost
GREEN
POWER
• 3 year warranty
Dimensions:
VCE40:
The VCE40 is a series of open frame and encapsulated AC-DC single output power supplies
designed for low cost ITE, industrial and domestic applications. The series provides two mechanical
options including open frame and encapsulated PCB mount. With approvals to world-wide safety
standards including ITE and Household, compliance with class B for conducted and radiated
emissions, these class II isolation parts benefit system designers with easy integration into a wide
range of applications.
3.46 x 1.50 x 1.12” (87.9 x 38.1 x 28.5 mm)
VCE40-P:
3.35 x 1.38 x 1.09” (85.0 x 35.1 x 27.7 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
Model Number(1)
30 W
40 W
40 W
40 W
40 W
40 W
40 W
3.3 VDC
5.0 VDC
9.0 VDC
12.0 VDC
15.0 VDC
24.0 VDC
48.0 VDC
9.10 A
8.00 A
4.44 A
3.33 A
2.66 A
1.66 A
0.82 A
VCE40US03
VCE40US05
VCE40US09
VCE40US12
VCE40US15
VCE40US24
VCE40US48
Notes
1. For Open Frame version add suffix -P to model number, e.g. VCE40US12-P.
Summary
Characteristic
Minimum
Typical
Maximum
305
Units
VAC
W
Notes & Conditions
Input Voltage Range
No Load Input Power
Efficiency
85
Derate output from 100% at 90 VAC to 90% at 85 VAC
0.3
85
%
Model dependant
3V3 & 5V models: derate output linearly from 100% at
+45 °C to 45% at +70 °C.
Operating Temperature
-25
+70
°C
Other models: derate output linearly from 100% at 50 °C to
50% at 70 °C.
EMC
EN55032 Level B Conducted & Radiated, EN601000-3-2, EN61000-3-3, EN55024
IEC62368-1, IEC60335-1, IEC60950-1, EN62368-1, EN60335-1, UL62368-1
Safety Approvals
Input
Minimum
Typical
Maximum
305
Units
VAC
Hz
Notes & Co
nditions
Characteristic
Input Voltage Range
Input Frequency
85
47
Derate from
100% at 90 VAC to 90% at 85 VAC
63
VAC
Input Current - Full Load
No Load Input Power
Inrush Current
0.7/0.4
A rms
W
A
At 115/230
0.3
40
At 230 VAC
, cold start 25 °C
Earth Leakage Current
Input Protection
Class II con
struction no earth
Internal T1.0 A/300 VAC fuse fitted in line
www.xppower.com
1
AC-DC Power Supplies
VCE40 Series
Output
Characteristic
Output Voltage
Initial Set Accuracy
Minimum Load
Line Regulation
Minimum
Typical
Maximum
48
1.5/1.0
Units
VDC
%
Notes & Conditions
3.3
1.5% for 3V3 & 5 V models
, 1% for others at 50% loa
d
0
A
No minimum lo
ad required
1
%
Load Regulation
Start Up Delay
Start Up Rise Time
Hold Up Time
2
2
35
s
ms
ms
8
14
at full load and
115 VAC
Deviation, recovery within 1
for a 25% load change
% in less than 500 µs
Transient Response
Ripple & Noise
4
%
100
mV pk-pk
% pk-pk
% Vnom
%
3V3 & 5 V models, 20 MHz
bandwidth
9 to 48 V m
odels, 20 MHz bandwidth
Overvoltage Protection
Overload Protection
115
110
140
190
210% typical for 3V3 mode
l, auto recovery
Short Circuit Protection
Temperature Coefficient
Trip & Restart (hiccup mod
e)
0.05
%/˚C
General
Characteristic
Efficiency
Minimum
Typical
85
Maximum
Units
%
Notes & Conditions
Model Dependant
Isolation: Input to Output
Switching Frequency
Power Density
3000
5
VAC
kHz
W/in
65
7.7
Varied with load
For ‘-P’ version
3
Mean Time Between Failure
550
600
0.187 (85)
0.419 (190)
kHrs
lb (g)
lb (g)
MIL-HDBK-217F, +25 °C GB
Open frame versions (-P)
Encapsulated version
Weight
Efficiency Graphs
VCE40US12-P
100%
90%
80%
70%
60%
50%
115Vac
230Vac
10
20
30
40
50
60
70
80
90
100
Load (%)
VCE40US24-P
100%
90%
80%
70%
60%
50%
115Vac
230Vac
10
20
30
40
50
60
70
80
90
100
Load (%)
www.xppower.com
2
AC-DC Power Supplies
VCE40 Series
Environmental
Characteristic
Minimum
Typical
Maximum
+70
Units
°C
Notes & Conditions
3V3 & 5V models: derate output linearly from 100% at
+45 °C to 45% at +70 °C.
Operating Temperature
-25
-40
Other models: derate output linearly from 100% at 50 °C to
50% at 70 °C.
Storage Temperature
Cooling
+85
°C
Convection-cooled
Non-condensing
Humidity
95
%RH
m
Operating Altitude
Shock
5000
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes
IEC68-2-6, 2 g, 10 Hz to 500 kHz, 10 mins/cycle, 60 mins each cycle
Vibration
EMC: Emissions
Phenomenon
Standard
EN55032
Test Level
Criteria
Notes & Conditions
Conducted
Class B
If output is connected to a ground additional
external components will be required. Contact sales
for details
Radiated
EN55032
Class B
Harmonic Current
Voltage Flicker
EN61000-3-2
EN61000-3-3
Class A
EMC: Immunity
Phenomenon
ITE
Standard
Test Level
Criteria
Notes & Conditions
EN55024
EN55035
As Below
As Below
6kV contact,
8kV air discharge
ESD
EN61000-4-2
A
Radiated
EFT
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
10 V/m
3
A
A
A
A
A
A
B
A
B
A
A
A
B
Surge
2
Line to Line
Conducted
Magnetic Fields
10 Vrms
30 A/m
T
70% U (80.5 VAC) for 100 ms
T
40% U (46 VAC) for 200 ms
EN61000-4-11 (115 VAC)
EN61000-4-11 (230 VAC)
T
<5% U (0 VAC) for 10 ms
T
<5% U (0 VAC) for 5000 ms
Dips and Interruptions
T
70% U (161 VAC) for 100 ms
T
40% U (92 VAC) for 200 ms
T
<5% U (0 VAC) for 10 ms
T
<5% U (0 VAC) for 5000 ms
Safety Approvals
Safety Agency
Safety Standard
IEC60950-1
IEC62368-1
IEC60335-1
UL62368-1
Notes & Conditions
ITE
CB
Household
ITE
UL
TUV
EN62368-1
ITE
www.xppower.com
3
AC-DC Power Supplies
VCE40 Series
Mechanical Details
Encapsulated
Pin Connections
Single
Pin
1
Open Frame (-P)
ACL
2
ACN
3
-Vout
4
+Vout
Notes
1. Dimensions in inches (mm).
2. Weight: Open frame versions (-P): 0.187 lbs (85 g)
Encapsulated: 0.419 lbs (190 g)
3. Tolerances:
x.xx = 0.02 (x.x = 0.5)
x.xxx = 0.01 (x.xx = 0.25)
www.xppower.com
19 Sept 19
相关型号:
©2020 ICPDF网 联系我们和版权申明