VEH90PS19 [XPPOWER]
Energy Efficiency Level V, CEC 2008 & EISA 2007 Compliant;型号: | VEH90PS19 |
厂家: | XP POWER LIMITED |
描述: | Energy Efficiency Level V, CEC 2008 & EISA 2007 Compliant |
文件: | 总2页 (文件大小:466K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
xppower.com
90 Watts
VEH Series
•
•
•
•
•
•
•
Energy Efficiency Level V
CEC 2008 & EISA 2007 Compliant
High Power Density
Single Outputs from 12 V to 24 V
No Load Input Power <0.5 W
Optional Output Connector
Low Cost
B R A N D
Specification
Input
General
Input Voltage
Input Frequency
Input Current
Inrush Current
• 90-264 VAC
• 47-63 Hz
• 1.5 A max at 90 VAC
• 110 A max at 230 VAC, cold start at 25 °C
Efficiency
• See table
• Level V
• 3000 VAC Input to Output,
1500 VAC Input to Ground
PS12: 500 VDC Output to Ground,
PS19/24: Negative output is connected to
Ground
Energy Efficiency
Isolation
Earth Leakage Current • <1 mA at 230 VAC/50 Hz
Power Factor • >0.95 at 230 VAC and full load
No Load Input Power • <0.5 W
Switching Frequency
MTBF
• PFC: 25-125 kHz, PWM: 60 kHz typical
• >160 kHrs to Bell Core iss. 6
Input Protection
• Internal T2.0A/250 V fuse in line
Environmental
Output
Operating Temperature • 0 °C to +60 °C derate linearly from 100%
load at +40 °C to 50% load at +60 °C,
Storage Temperature • -10 ˚C to +85 °C
Output Voltage
• See table
Initial Set Accuracy
Minimum Load
•
5% at 50% load
• No minimum load requirement
• 10 ms min at 115 VAC, full load
• 3 s max
Operating Humidity
Storage Humidity
Shock
• 5% to 90% RH non-condensing
• 5% to 95% RH non-condensing
• 6 Random drops from 0.7 m with no
damage, 50 g for 20 ms in each of 3 axes
Hold Up Time
Start Up Delay
Start Up Rise Time
Transient Response
• 8 ms typical
• 4% maxiumum deviation, recovering to
less than 1% within 500 µs for a 50%
step load change
Vibration
• 2 g variable frequency from 20 Hz to 30 Hz
Line Regulation
Load Regulation
Ripple & Noise
•
•
0.5% max
5% max
EMC & Safety
Emissions
• EN55022, level B conducted & radiated
• EN61000-3-2 class A,
• 1% pk-pk max, 20 MHz bandwidth
(see note 1)
Harmonic Currents
EN61000-3-2 class C >60% load
• EN61000-3-3
Overvoltage Protection • See table
Overload Protection • 120 -180%
Short Circuit Protection • Continuous (hiccup/trip & restart mode
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, installation class 3,
Perf Criteria A
with auto recovery)
Temperature
Coefficient
•
0.04%/°C
Surge
Conducted Immunity
Magnetic Field
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals
• EN60950-1:2001, UL/cUL60950-1
VEH90
Models and Ratings
Output Power
Output Voltage
Output Current
OVP Setting(2)
Effeciency(3)
Model Number(4)
90 W
90 W
90 W
12.0 V
19.0 V
24.0 V
7.50 A
4.74 A
3.75 A
16.0 V
25.0 V
32.0 V
88%
88%
89%
VEH90PS12†^
VEH90PS19†^
VEH90PS24†^
Notes
1. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF
electrolytic capacitor.
2. Typical values.
3. Average of efficiencies measured at 25%, 50%, 75% and 100% load and
230 VAC input.
4. For optional barrel jack connector, 2.5 mm inner positive, 5.5 mm outer
negative, 11 mm length add suffix ‘-B’ e.g. VEH90PS24-B
† Available from Farnell & element14. See page 28.
^ Available from Newark. See page 28.
Mechanical Details
3
1
2
4
Pin
1
2
3
Function
Output +
Output +
Return*
4
Shell
Return*
Floating
*Return is internally connected
to input earth on 19 V & 24 V
models
5.24
(133.0)
Power Cord, Order Part:
UK - UK-MAINS-5
European - EU-MAINS-5
US - US-MAINS-5
1.19
(30.3)
2.28
(58.0)
IEC320-C6
0.67
(17.0)
Notes
1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length.
2. Weight 0.82 lbs (370 g) approx.
3. Cable length is 48” 2”(1220 50 mm) approx.
4. Output connector (Power Mini Din) mates with Kycon KPJ-4S or equivalent.
18-May-11
相关型号:
©2020 ICPDF网 联系我们和版权申明