VEL36US180-US-JA [XPPOWER]
VEL36 Series AC-DC Power Supplies;型号: | VEL36US180-US-JA |
厂家: | XP POWER LIMITED |
描述: | VEL36 Series AC-DC Power Supplies |
文件: | 总4页 (文件大小:616K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AC-DC Power Supplies
VEL36 Series
36 Watt
• Energy Efficiency Level VI
xxx Series
• European CoC Tier 2
• Fixed Mains Connectors
• Universal Input
• Output Voltages from 12 V to 24 V
• Class II Construction
• Low Cost
B R A N D
Dimensions:
The VEL36 series of wall plug adaptors comply with the very latest energy efficiency VI standards
with high active mode efficiency and extremely low no load power consumption. Available with a
standard jack plug connector these adaptors suit a wide variety of cost sensitive applications while
maintaining industry leading performance.
VEL (body only):
-US: 3.70 x 1.38 x 1.83” (94.0 x 35.0 x 46.6 mm)
-EU: 3.70 x 1.38 x 2.55” (94.0 x 35.0 x 64.8 mm)
-UK: 3.70 x 1.95 x 2.11” (94.0 x 49.6 x 53.6 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
Total Regulation(2)
Output Connector
Model Number(3)
VEL36US120-XX-JA(4)
VEL36US150-XX-JA
12.0 V
15.0 V
3000 mA
2400 mA
5%
5%
5.5 x 2.1 x 12 mm DC Jack
5.5 x 2.1 x 12 mm DC Jack
36 W
18.0 V
24.0 V
2000 mA
1500 mA
5%
5%
5.5 x 2.1 x 12 mm DC Jack
5.5 x 2.1 x 12 mm DC Jack
VEL36US180-XX-JA
VEL36US240-XX-JA
Notes
3. Replace ‘XX’ in model number with ‘US’ for US mains plug, ‘UK’ for UK
plug or ‘EU’ for European mains plug.
mains
1. Other output voltages available, contact sales for details.
2. Total regulation includes initial set accuracy, line and load regulation.
4. Meets DOE efficiency level VI and CoC tier 1, not tier 2.
Input
Characteristic
Minimum
Typical
Maximum
264
Units
VAC
Hz
Notes & Conditions
Input Voltage
90
47
Input Frequency
Input Current
63
0.8
A
100 VAC
Inrush Current
Power Factor
120
A
240 VAC, cold start at 25 °C
EN61000-3-2, class A
No Load Input Power
Input Protection
75
mW
Internal T1.0A/250 VAC fuse
Output
Characteristic
Output Voltage
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Minimum
Typical
Maximum
Units
V
Notes & Conditions
12
0
24
See Models and Ratings table
No minimum load required
A
4
s
30
ms
ms
%
8
Full load and 100 VAC
Total Regulation
5
5
See Models and Ratings table
Recovely within <1% within 500 µs for a 60% step load
change at 0.15 A/µs
Transient Response
Ripple & Noise
% deviation
mV pk-pk
Measured with 20 MHz bandwidth and 47 µF electrolytic in
parallel with 0.1 µF ceramic capacitor
180
Short Circuit Protection
Temperature Coefficient
Continuous, trip and restart (hiccup mode) with auto r
ecovely
0.05
%/˚C
www.xppower.com
1
AC-DC Power Supplies
VEL36 Series
General
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Typical average of efficiencies measured at 25%, 50%, 75%
and 100% load and 115 VAC input
Efficiency
87
%
Energy Efficiency
Isolation
Level VI
3000
24
VAC
kHz
kHrs
Input to Output
Variable
Switching Frequency
Mean Time Between Failure
70
250
MIL-HDBK-217F at 25 °C GB
EU and US versions
UK versions
0.32 (147.0)
0.34 (155.0)
Weight
lb (g)
Environmental
Characteristic
Operating Temperature
Storage Temperature
Operating Humidity
Cooling
Minimum
Typical
Maximum
+60
Units
Notes & Conditions
0
-40
5
°C
°C
%
Derate from 100% load at 45 °C to 50% load at 60 °C
+85
95
RH, non-condensing
Natural convection
Shock
1 m drop onto concrete on each of 6 axes
2 g 15 mins/sweep, 60 mins for each of 3 axes
Vibration
10
300
Hz
EMC: Emissions
Phenomenon
Conducted
Standard
Test Level
Notes & Conditions
EN55022
EN55022
Level B
Level B
Class A
Radiated
Harmonic Current
Voltage Flicker
EN61000-3-2
EN61000-3-3
EMC: Immunity
Phenomenon
Standard
Test Level
Criteria
Notes & Conditions
ESD Immunity
Radiated Immunity
EFT/Burst
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
4 kV contact, 8 kV air
A
A
A
A
A
A
3 V/m
Level 2
Level 2
3 V
Surge
Conducted Immunity
Magnetic Fields
Dips and Interruptions
1 A/m
EN55024 100% 10 ms, 30% 500 ms, 100% 5000 ms, Perf Criteria A, A, B
Safety Approvals
Phenomenon
CB Report
UL
Standard
IEC60950-1
UL/cUL60950-1, approved as limited power source (LPS)
EN60950-1
TUV
CCC
China Compulsory Certification
www.xppower.com
2
AC-DC Power Supplies
VEL36 Series
Mechanical Details
VEL36US-US-JA
1.83
(46.6)
0.54
(13.7)
0.63
(16.1)
0.5 (1.5)
0.5 (12.7)
0.25 (6.35)
3.7 (94.0)
1.57 (40.0)
3-R2.00
C2
1.06
(27.0)
1.37
(35.0)
1.57 (40.0)
VEL36US-UK-JA
0.69
(17.6)
0.27
(7.0)
0.37
(9.5)
0.89
(22.7)
0.31 (7.95)
2.11 (53.6)
0.15
(4.0)
1.45 (37.0)
R2.00
1.06
1.95
(49.6)
0.87
(27.0)
(22.2)
3.7 (94.0)
0.87 (22.23)
www.xppower.com
3
DC-DC Converter
VEL36 Series
Mechanical Details
VEL36US-EU-JA
0.74
(19.0)
0.41
(10.5)
0.71
(18.2)
0.73 (18.6)
0.68 (17.5)
0.15 (4.0)
0.14 (3.8)
0.15 (4.0)
1.39 (35.5)
3.7 (94.0)
1.57 (40.0)
1.83
(46.6)
1.06
(27.0)
1.37
(35.0)
1.02
(26.1)
Output Lead and Connection
24 AWG
0.083 (2.1)
0.47 (12.0)
0.22 (5.5)
BLACK AND WHITE
59.0 (1500)
TIE
PVC 30-35P
2.7 (70)
Wire type: VW-1 80°C 300 V L=1500 mm 2464, 18 AWG for 12 V output, 20 AWG for 15 V ouput,
22 AWG for 18 and 24 V output, 2C Black and White. Black - Negative, White - Positive
Polarity
www.xppower.com
17 Mar 16
相关型号:
VEL36US180-XX-JA
VEL36 Series AC-DC Power SuppliesWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
XPPOWER
VEL36US240-EU-JA
VEL36 Series AC-DC Power SuppliesWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
XPPOWER
VEL36US240-UK-JA
VEL36 Series AC-DC Power SuppliesWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
XPPOWER
VEL36US240-US-JA
VEL36 Series AC-DC Power SuppliesWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
XPPOWER
VEL36US240-XX-JA
VEL36 Series AC-DC Power SuppliesWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
XPPOWER
VEM14E10-320.0002.5/-30+75
Sine Output Oscillator, 320MHz Nom, DIP-14/4Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EUROQUARTZ
VEM14E10-9.6001.0/0+50
Sine Output Oscillator, 9.6MHz Nom, DIP-14/4Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EUROQUARTZ
VEM14E10-9.6001.5/-30+75
Sine Output Oscillator, 9.6MHz Nom, DIP-14/4Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EUROQUARTZ
VEM14E10-9.6002.5/-10+60
Sine Output Oscillator, 9.6MHz Nom, DIP-14/4Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EUROQUARTZ
VEM14E15-320.0002.0/-10+60
Sine Output Oscillator, 320MHz Nom, DIP-14/4Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EUROQUARTZ
VEM14E15-320.0002.5/-30+75
Sine Output Oscillator, 320MHz Nom, DIP-14/4Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EUROQUARTZ
VEM14E3-9.6001.0/0+50
Sine Output Oscillator, 9.6MHz Nom, DIP-14/4Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
EUROQUARTZ
©2020 ICPDF网 联系我们和版权申明