VES120 [XPPOWER]
VES120 Series AC-DC Power Supplies;型号: | VES120 |
厂家: | XP POWER LIMITED |
描述: | VES120 Series AC-DC Power Supplies |
文件: | 总4页 (文件大小:605K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AC-DC Power Supplies
VES120 Series
120 Watts
• Energy Efficiency Level VI
• European CoC Tier 2
• High Power Density
• Single Outputs from 12 V to 24 V
• <0.15 W Standby Power
• China Compulsory Certification (CCC) Qualified
• 0 °C to 60 °C Operation
• Optional Output Connector
• Low Cost
B R A N D
Dimensions:
VES120:
6.61 x 2.80 x 1.48” (168.0 x 71.0 x 37.5 mm)
Models & Ratings
Output Power
Output Voltage
Output Current
Total Regulation
Efficiency(1)
Model Number(2)
12.0 V
19.0 V
24.0 V
10.00 A
6.32 A
5.00 A
89%
89%
89%
VES120PS12
VES120PS19
VES120PS24
120 W
5%
Notes
1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 230 VAC input.
2. For optional Barrel Jack Connector, 2.5 mm inner positive, 5.5 mm outer negative, 11 mm length add suffix ‘-B’ e.g. VES120US24-B.
Mechanical Details
47.24 0.79 (1200 20)
6.61 (168.0)
2.76 0.20
(70 5)
Pin
1
2
Function
Output +
Output +
Return
UL 10748 16AWG*1C+S Black
3
4
Return
4 PINS DC POWER CONNECTOR
Connected to output
return and input ground
Shell
2.36 0.79
(60 20)
4.72 0.79
(120 20)
2.36 0.79
(60 20)
For optional barrel jack connector,
outer sleeve (negative) is connected to
input ground
1.48 0.02 (37.5 0.5)
CORE: ø14.2*2*ø7.0*L28.5
Notes
1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except
output cable length.
3. Weight: 1.27 lbs (580 g) approx.
2. Output connector: Power Mini DIN, mates with Kycon KPJ-4S or equivalent.
www.xppower.com
1
AC-DC Power Supplies
VES120 Series
Input
Characteristic
Minimum
Typical
Maximum
264
Units
Notes & Conditions
Input Voltage
90
47
VAC
Input Frequency
Input Current
Inrush Current
63
Hz
A
A
2/1
Measured at 115/230 VAC
230 VAC, cold start at 25 °C
EN61000-3-2 Class A
264 VAC, 60 Hz
130
Power Factor
Earth Leakage Current
No Load Input Power
Input Protection
500
µA
W
0.15
T3.15A/250 VAC internal fuse in line
Output
Characteristic
Min.
Typ.
Max.
Units
Notes & Conditions
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
12
24
2
VDC
%
See Models and Ratings table
At 50% load
No minimum load required
3
50
s
ms
ms
%
8
Full load and 115 VAC
Line Regulation
Total Regulation
0.5
5
%
Maximum deviation, recovering to less than 1% within
500 µs for 50% step load
Transient Response
10
%
2% for 12 V, 1% for 19 & 24 V,
20 MHz bandwidth, measured with 20 MHz Bandwidth and
10 µF electrolytic in parallel with 0.1 µF ceramic capacitor.
Ripple and Noise
2/1
% pk-pk
Overshoot
2
%
%
%
At turn on / turn off
Overload Protection
Overvoltage Protection
Short Circuit Protection
Temperature Coefficient
120
200
180
Recycle mains to reset
Trip and restart (hiccup), auto resetting
0.04
%/°C
Environmental
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Operating Temperature
Cooling
0
+60
°C
Derate from 100% load at 40 °C to 50% load at 60 °C
Natural convection
Operating Humidity
Storage Temperature
Operating Altitude
Shock
10
-40
90
+70
5000
%RH
°C
m
Non-condensing
IEC68-2-27, 30 g, 30 ms half sine, 3 times in each of 6 axes
IEC68-2-6, 10-300 Hz, 2 g 15 mins/sweep, 60 mins for each of 3 axes, non operating
Vibration
100%
Derating Curve
80%
60%
40%
20%
60
0
20
40
Ambient Temperature (ºC)
www.xppower.com
2
AC-DC Power Supplies
VES120 Series
General
Characteristic
Minimum
Typical
Maximum
Units
%
Notes & Conditions
Efficiency
89
See Models and Ratings table and curves.
3000
1500
VAC
VAC
VDC
kHz
Isolation: Input to Output
Input to Ground
Output to Ground
Output return is connected to input ground
At full load
Switching Frequency
Power Density
55
4.3
3
W/in
Mean Time Between Failure
Weight
>200
kHrs
lb (g)
MIL-HDBK-217F at 25 °C GB
1.27 (580)
Efficiency Curves
VES120PS12
100%
90%
80%
70%
60%
50%
115Vac
230Vac
10
20
30
40
50
60
70
80
90
100
Load (%)
VES120PS24
100%
90%
80%
70%
60%
50%
115Vac
230Vac
10
20
30
40
50
60
70
80
90
100
Load (%)
EMC: Emissions
Phenomenon
Standard
Test Level
Notes & Conditions
Emissions
Harmonic Current
Voltage Flicker
EN55022
EN61000-3-2
EN61000-3-3
Level B
Class A
Conducted & Radiated
www.xppower.com
3
AC-DC Power Supplies
VES120 Series
EMC: Immunity
Phenomenon
Standard
Test Level
Criteria
Notes & Conditions
ESD
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
8 kV Air, 4 kV contact
3 V/m
A
A
A
A
A
Radiated
EFT/Burst
Surge
Conducted
Magnetic Fields
2
Installation Class 3
3 V
3 A/m
A
Dip: 30% 500 ms
Dip: 60% 200 ms
Dip: 100% 5000 ms
Int: 100% 10 ms
A/B
A/B
B
High Line/Low Line
High Line/Low Line
Dips and Interruptions
EN61000-4-11
A
Safety Approvals
Safety Agency
Safety Standard
UL60950-1
Notes & Conditions
UL
TUV
CB
EN60950-1
IEC60950-1
CCC
China Compulsory Certification (CCC) Qualified
Mechanical Details
47.24 0.79 (1200 20)
6.61 (168.0)
2.76 0.20
(70 5)
UL 10748 16AWG*1C+S Black
4 PINS DC POWER CONNECTOR
2.36 0.79
(60 20)
4.72 0.79
(120 20)
2.36 0.79
(60 20)
1.48 0.02 (37.5 0.5)
CORE: ø14.2*2*ø7.0*L28.5
Pin
1
2
Function
Output +
Output +
Return
3
4
Return
For optional barrel jack connector,
outer sleeve (negative) is connected to
input ground
Connected to output
return and input ground
Shell
Notes
1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except
output cable length.
3. Weight:
lbs (
g) approx.
2. Output connector: Power Mini DIN, mates with Kycon KPJ-4S or equivalent.
www.xppower.com