Z0220112VSC [ZILOG]

Modem-Support Circuit, 2.4kbps Data, PQCC44, PLASTIC, LCC-44;
Z0220112VSC
型号: Z0220112VSC
厂家: ZILOG, INC.    ZILOG, INC.
描述:

Modem-Support Circuit, 2.4kbps Data, PQCC44, PLASTIC, LCC-44

电信 电信集成电路
文件: 总19页 (文件大小:226K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Totally Logical  
ZiLOG V.22bis Modem  
Z02201 Data Pump/AFE  
Z02205 Controller  
Agenda  
Totally Logical  
u ZiLOG Commitment to the Embedded Modem  
u What Is ZiLOG’s V.22bis Modem Solution?  
u Z02201 Data Pump/AFE Description  
u Z02205 Modem Controller Description  
u Features Comparison With Competition  
u Modem Schematic  
u Modem BOM With Component Costs  
u Availability  
u Summary  
Commitment  
Totally Logical  
u ZiLOG Is Committed to Support Your  
Embedded Modem Needs  
u Today  
2400bps and 9600bps  
u Tomorrow  
Higher Integration -- Single Chip  
3.3volt  
14.4kbps and Faster  
ZiLOG’s V.22bis Modem  
Totally Logical  
u Two-Chip Set Z02201 Data Pump/AFE  
Z02205 Modem Controller  
u Supports Popular Modulation Standards  
V.22bis, V.23, V.22, V.21, Bell212a, Bell103  
u 2400bps Transmit Rate  
u Competitive BOM Cost  
u Small Size -- No External Memory Required  
u Quick Time to Market  
u ZiLOG Can Arrange Assistance With Your Design  
Both Hardware and Software  
Main Applications  
Totally Logical  
u ZiLOG’s V.22bis Modem’s Primary Applications:  
TV Set Top Box Modem  
Satellite Receiver Modem  
Security System Modem  
Remote Diagnostics  
Utility Meter Modem  
Remote Telemetry  
Smart Card Terminal  
and many more!  
V.22bis Modem Overview  
Totally Logical  
Controller DSP/AFE  
DAA  
RJ 11  
Trans-  
former  
DTE side  
Phone line  
Z02201  
(Data  
Terminal  
Equipment)  
u No External Memory  
u Minimum External Logic Required  
u Hybrid Included On-chip Reduces BOM Cost.  
“Direct Connect” to the DAA  
Z02201 V.22bis DSP/AFE  
Totally Logical  
u Single Chip Data Pump and AFE Solution  
u V.22bis, V.22, V.23, V.21, Bell212a/103  
ADC  
DAC  
Osc  
Parallel  
I/F  
DSP  
u 2 Types of Handshake Timings  
Automatic ITU Standard Handshakes  
Manual Control Over Handshakes  
V.24  
Serial  
I/F  
8KW ROM  
512W RAM  
Eye  
Pattern  
u Tone Generators and Tone Detectors Fully  
Programmable to Simplify Country  
Qualifications  
u Low power consumption  
50mA Active Mode  
25uA Sleep Mode  
u Small Package  
u Auto-dial and Answer Support  
DTMF & Calling Tone Generation/detection  
Call Progress Tone Detection  
u Excellent Line Compensation  
Multiple Compromise and Cable Equalizers  
u HDLC Framing in Software  
44-pin PLCC  
u No External Memory Required, Minimal  
External Logic  
Z02205 Modem Controller  
Totally Logical  
u 8-bit Modem Controller With Embedded  
C/T  
Ints  
Osc  
24bit  
Par.I/O  
Z8  
uC  
ROM  
u 16K ROM Onchip Contains All AT  
Commands  
16KB ROM  
237W RAM  
u Basic AT Command Set  
WDT/  
POR  
Analog  
Compar  
AT +++, A, A/, B, D, E, &F, &G, H, I, N, O,  
P, &P, Q, Sn, ?, =X, T, V, X  
Dial Modifiers  
uLow power consumption  
25mA Active Mode @ 5V  
10uA Sleep Mode  
uSmall Package  
S37 -- Register to Control Connect Rate  
u Basic Data Pump Driver Source Code  
Available  
u Homologation Code  
28-pin SOIC  
Additional Features  
Totally Logical  
Feature  
Benefit  
Control Handshake Manually  
Customization  
Programmable Transmit Level  
-6db to -43db  
More Country Qualifications  
Programmable DTMF Tone Transmit  
Programmable  
Programmable Bandpass and  
Tone Detectors  
Replace Old Analog Tone  
Detection Logic. Save Cost.  
Simple, Flexible Homologation  
Less Engineering  
V.23 for Europe and  
South America  
Same Solution  
Serves Worldwide  
2- to 4- Wire Hybrid  
Integrated Onchip  
Fewer Components,  
Lower Cost  
Small Packages  
Small P.C. Board  
Data Pump Comparison  
Totally Logical  
Z02201  
TSC73K324L  
RC2324  
Package  
44 PLCC  
+5V +/-10%  
50 mA max  
25 uA  
28 PLCC  
+5V +/-10%  
25 mA max  
68 PLCC  
+5V +/-10%  
48 mA max  
3 mA  
Power supply  
Active Supply Current  
Sleep Current  
Operating Temp  
Storage Temp  
Crystal Frequency  
V.22bis  
3 mA  
-40 to +85C  
-65 to +150C  
24.576 MHz  
Yes  
-40 to +85C  
-65 to +150C  
11.0592 MHz  
0 to +60C  
-55 to +85C  
24 MHz  
Yes  
Yes  
V.22  
Yes  
Yes  
Yes  
V.21  
Yes  
Yes  
Yes  
V.23  
Yes  
Yes  
Yes  
Bell 212A  
Yes  
Yes  
Yes  
Bell 103  
Yes  
No  
Yes  
MCU bus  
Serial I/F  
Parallel I/F  
HDLC  
Standard 8-bit  
Not Used  
Yes  
Standard 8-bit  
Standard 8-bit  
Yes  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
Integrated Hybrid  
Yes  
No. Yes on "324BL"  
Yes  
Fully programmable  
-6 dBm max.  
-6 to -35 dBm  
Tx Level  
-6 to -21 dBm  
0 to -15 dBm  
Dynamic Range  
Reception Timing  
Tone Generators  
-3 to -43 dBm  
+/-0.02% freq. error  
Fixed  
-9 to -43 dBm  
+/-0.017% freq. error  
Programmable  
+/-0.01% freq. error  
Fully Programmable  
Fully Programmable  
16 single freq. plus  
biquads (2048 steps)  
Yes  
Biquads and "zero  
crossing" only  
Tone Detectors  
Fixed and limited  
Adaptive Equalizers  
Compromise  
Equalizers  
Yes  
Yes  
Programmable  
Fixed  
Fixed, Tx only  
EYE Monitoring  
Analog I/F  
Yes  
No  
Yes  
Analog out  
Analog out  
Manual only  
Analog Out  
Automatic only  
Handshake types  
Single chip solution  
available?  
Automatic and manual  
Coming Soon  
No  
Yes  
Get to Market Fast  
Totally Logical  
u Evaluation Kit Available - Evaluation Board  
Z0220100ZCO  
- Schematic and BOM  
- Data Pump Driver Code  
- Orcad Files  
- Product Specifications  
- User Manual  
u ZiLOG Can Arrange Assistance in System Level Design  
and in Controller Code Customization  
Z0220100ZCO Eval Kit  
Totally Logical  
u Demonstrate Basic  
Functionality of  
Optional DAA  
Jumpers  
Module  
Z02201 and Z02205  
SPEAKER  
u Customer Can Plug in  
CP Clare DAA Module  
to Support Other  
Country’s Phone  
Networks  
CY21XX  
DPOH  
uPOH  
J302  
RJ11  
CYG21XX  
STD.DAA  
J304  
J303  
MIDCOM  
671-8001  
Txd  
Z02205  
ACTIVE  
PASSIVE  
J301  
RxD  
DTR  
DCD  
OH  
Z02201  
u Contains Speaker and  
POWER  
POWER  
SWITCH  
ON  
OFF  
Eye Pattern Support  
Application Notes Available  
Totally Logical  
u Choosing a Crystal Oscillator  
u Bell202  
u Muting the V.23 Backchannel  
u Receive Caller ID  
TM  
Diplomat Code Utility  
Totally Logical  
u Simplify Country Qualifications  
u Modify Controller Object Code  
No Need for Source Code  
u Text-based  
Controller  
Object Code  
TM  
Diplomat  
Utility  
Country-Specific  
Controller Code  
Country  
Table  
Design Alternatives  
Totally Logical  
u Design Alternatives To Meet Your Needs  
Two-chip Solution: Z02201 + Z02205  
One-chip Solution: Z02201 Plus Controller Code  
Ported to Your Host Microprocessor  
Data Pump Driver Code in ‘C’ Available at No Charge  
Complete Controller Source Code in ‘C’ Available for  
One-time Fee  
$10K License Fee  
No License Fee  
•data pump driver code  
•AT commands  
•data pump driver code  
•Homologation code  
•Homologation code  
V.22bis Modem BOM  
Totally Logical  
PART NUMBER  
DESCRIPTION  
Z0220112VSC  
Z0220512SSC  
24.576mhz  
14.7456mhz  
Various  
Data Pump/AFE 44PLCC  
Controller 28pin SOIC  
Crystal  
1
1
1
Crystal  
1
Caps  
11  
10  
1
Various  
Resistors  
671-8005  
Zener  
Transformer  
Diodes  
4
Various  
Diodes  
3
4N35  
Opto Isolator  
Fuse  
1
0.25 Amp  
SPST  
1
Relay  
2
RJ11  
Phone Jack  
PCB  
1
PC Board  
VR101 250V/4.5A  
1
Varistor  
1
Z02201/Z02205 Availability  
Totally Logical  
u Samples  
Now  
Now  
Now  
Now  
u Production  
u Evaluation Kit  
u Product Spec  
u Customer Procurement Spec Now  
Customers Are Designing With This Solution Now!  
Start Your Design Today With the ZiLOG  
Evaluation Kit...  
V.22bis Modem Module  
Totally Logical  
u Standalone Modem  
Pre-Certified  
u Modules Available Q4’98 from  
various sources  
u Basic AT Command Set  
AT +++, A, A/, B, D, E, &F, &G, H,  
&HT, I, N, O, P, &P, Q, Sn, ?, =X, T,  
V, Z  
u CP Clare DAA Module (North  
America Q4’98, Europe Q1’99)  
www.cpclare.com  
u Comtech -- UK Version  
www.ctl-bolton.com  
ZiLOG V.22bis Modem  
Totally Logical  
u Z0220100ZCO Evaluation Kit  
u Competitive BOM Cost  
u Low Component Count Solution  
u Controller Code Is Available  
u Customization Is Available  
u Demonstration Is Available Today!  
u Visit ZiLOG’s Web Site at www.zilog.com  

相关型号:

Z0220112VSCR3470

V.22BIS Data Pump with INTEGRATED AFE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZILOG

Z0220112VSCR3470T

V.22BIS Data Pump with INTEGRATED AFE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZILOG

Z0220112VSCR3470TR

V.22BIS Data Pump with INTEGRATED AFE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZILOG

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
IXYS

Z0220112VSCR4078

V.22BIS Data Pump with INTEGRATED AFE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZILOG

Z0220112VSCR4078T

V.22BIS Data Pump with INTEGRATED AFE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZILOG

Z0220112VSCR4078TR

V.22BIS Data Pump with INTEGRATED AFE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZILOG

Z0220112VSGR3470

V.22BIS Data Pump with INTEGRATED AFE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZILOG

Z0220112VSGR4078

V.22BIS Data Pump with INTEGRATED AFE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZILOG

Z022011VSCR3470

Modem, PQCC44,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
IXYS

Z022011VSCR3470

Modem, PQCC44,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZILOG

Z022011VSCR4078

Modem, PQCC44,

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ZILOG