ZGFI7101JBT [ZILOG]

High Gain Differential Amplifier;
ZGFI7101JBT
型号: ZGFI7101JBT
厂家: ZILOG, INC.    ZILOG, INC.
描述:

High Gain Differential Amplifier

文件: 总14页 (文件大小:671K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Z8051 Series 8-Bit Microcontrollers  
ZGFI7101 Earth Leakage  
Detector  
Product Specification  
PS030402-0212  
P R E L I M I N A R Y  
Copyright ©2012 Zilog®, Inc. All rights reserved.  
www.zilog.com  
ZGFI7101 Earth Leakage Detector  
Product Specification  
ii  
DO NOT USE THIS PRODUCT IN LIFE SUPPORT SYSTEMS.  
Warning:  
LIFE SUPPORT POLICY  
ZILOG’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE  
SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF  
THE PRESIDENT AND GENERAL COUNSEL OF ZILOG CORPORATION.  
As used herein  
Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b)  
support or sustain life and whose failure to perform when properly used in accordance with instructions for  
use provided in the labeling can be reasonably expected to result in a significant injury to the user. A criti-  
cal component is any component in a life support device or system whose failure to perform can be reason-  
ably expected to cause the failure of the life support device or system or to affect its safety or effectiveness.  
Document Disclaimer  
©2012 Zilog, Inc. All rights reserved. Information in this publication concerning the devices, applications,  
or technology described is intended to suggest possible uses and may be superseded. ZILOG, INC. DOES  
NOT ASSUME LIABILITY FOR OR PROVIDE A REPRESENTATION OF ACCURACY OF THE  
INFORMATION, DEVICES, OR TECHNOLOGY DESCRIBED IN THIS DOCUMENT. ZILOG ALSO  
DOES NOT ASSUME LIABILITY FOR INTELLECTUAL PROPERTY INFRINGEMENT RELATED  
IN ANY MANNER TO USE OF INFORMATION, DEVICES, OR TECHNOLOGY DESCRIBED  
HEREIN OR OTHERWISE. The information contained within this document has been verified according  
to the general principles of electrical and mechanical engineering.  
Z8051 is a trademark or registered trademark of Zilog, Inc. All other product or service names are the  
property of their respective owners.  
PS030402-0212  
P R E L I M I N A R Y  
ZGFI7101 Earth Leakage Detector  
Product Specification  
iii  
Revision History  
Each instance in this document’s revision history reflects a change from its previous edi-  
tion. For more details, refer to the corresponding page(s) or appropriate links furnished in  
the table below.  
Revision  
Date Level  
Description  
Page  
Feb  
02  
Removed references to wafer sale product option.  
All  
2012  
Jan  
01  
Original Zilog issue.  
All  
2012  
PS030402-0212  
P R E L I M I N A R Y  
Revision History  
ZGFI7101 Earth Leakage Detector  
Product Specification  
Table of Contents  
1.  
General Description ........................................................................................................................................2  
Features ..........................................................................................................................................................2  
Ordering Information .......................................................................................................................................2  
Pin Assignment ...............................................................................................................................................2  
Block Diagram.................................................................................................................................................3  
Absolute Maximum Rating (TA = 25Ԩ)...........................................................................................................4  
Recommended Operating Condition : Ta = -30°C to 85°C.............................................................................4  
Electrical Characteristics.................................................................................................................................5  
Typical Performance Curves...........................................................................................................................6  
Test Circuit.......................................................................................................................................................7  
Typical Application...........................................................................................................................................9  
Package Dimensions.....................................................................................................................................10  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
9.  
10.  
11.  
12.  
PS030402-0212  
P R E L I M I N A R Y  
1
ZGFI7101 Earth Leakage Detector  
Product Specification  
1. General Description  
The ZGFI7101 is designed for use in earth leakage circuit interrupters for operation directly off the AC  
Line in breakers. It contains pre-regulator, main-regulator, after-regulator, differential amplifier, level  
comparator, latch circuit. The input in the differential amplifier is connected to the secondary node of zero  
current transformer. The level comparator generates high level when earth leakage current is greater than  
some level.  
2. Features  
Low Power consumption (PD = 5mW) 100V/ 200V  
100V/200V Common Built-in Voltage Regulator  
High Gain Differential Amplifier  
High Input Sensitivity (VT = 13.5mV Typ.)  
Minimum External Parts  
Large Surge Margin  
Wide Operating Temperature Range (TA = -30 to 85Ԩ)  
High Noise Immunity  
GL7101,M54122 pin compatible  
3. Ordering Information  
Device Name  
ZGFI7101JBT  
ZGFI7101PBT  
Package  
8_SOP  
8_PDIP  
4. Pin Assignment  
PS030402-0212  
P R E L I M I N A R Y  
2
ZGFI7101 Earth Leakage Detector  
Product Specification  
5. Block Diagram  
PS030402-0212  
P R E L I M I N A R Y  
3
ZGFI7101 Earth Leakage Detector  
Product Specification  
6. Absolute Maximum Rating (TA = 25)  
Supply voltage  
20  
V
Supply Current  
8
mA  
mW  
Power Dissipation  
Operating Temperature  
Storage Temperature  
200  
-30 to 85  
-55 to 125  
7. Recommended Operating Condition : Ta = -30°C to 85°C  
PARAMETER  
Supply Voltage  
SYMBOL  
V+  
MIN.  
12  
TYP.  
MAX.  
UNIT  
V
Vs-GND Capacitor  
Os-GND Capacitor  
Cvs  
1
uF  
Cos  
1
uF  
PS030402-0212  
P R E L I M I N A R Y  
4
ZGFI7101 Earth Leakage Detector  
Product Specification  
8. Electrical Characteristics  
TEMP  
(°C)  
TEST  
CIRCUT  
PARAMETER SYMBOL  
CONDTIONS  
MIN.  
TYP. MAX.  
UNIT  
-30  
-
-
580  
SupplyCurrent1  
*Trip Voltage  
IS1  
VT  
V+=12V, VR-VI=30mV  
uA  
1
25  
85  
-
-
400  
-
530  
480  
V+=16V. VR-VI=X  
-30~85  
9
13.5  
18  
-30  
37  
mV(rms)  
2
3
Differential  
Amplifier  
V+=16V, VR-VI=30mV  
VOD=1.2V  
ITD1  
25  
-12  
-
uA  
Output Current1  
Differential  
Amplifier  
V+=16V, VR-VI=short  
VOD=0.8V  
ITD2  
25  
17  
-
-
uA  
uA  
4
5
Output Current2  
IS1=580 uA  
VSC=1.4V  
-30  
-200  
Output Current  
IO  
IS1=530 uA  
VOS=0.8V  
25  
85  
25  
-100  
-75  
-
-
-
IS1=480 uA  
V+=16V  
SC On Voltage  
VSC ON  
ISC ON  
0.7  
1.4  
5
V
6
7
SC Input Current  
V+=12V  
25  
-
-
-
uA  
Output “L” Current  
IOSL  
V+12V, VOSL =0.2V  
-30~85  
200  
-
uA  
8
Input Clamp  
Voltage  
VIC  
V+=12V, VIC=20mA  
IIDC = 100mV  
-30~85  
-30~85  
4.3  
0.4  
-
-
6.7  
2
V
V
9
Differential Input  
Clamp Voltage  
VIDC  
10  
Max Current  
voltage  
VSM  
ISM=7mA  
25  
20  
-
28  
V
11  
Supply Current 2  
IS2  
V+OFF  
TON  
VOS=0.5V, VR-VI=X  
-30~85  
25  
-
0.5  
1
-
-
-
900  
uA  
V
12  
13  
14  
Latch Circuit Off  
Supply Voltage  
Response Time  
V+=16V, VR-VI=0.3V  
25  
4
ms  
* A :9~12.55 ,B :11.5~15.5 ,C :14.5 ~ 18  
PS030402-0212  
P R E L I M I N A R Y  
5
ZGFI7101 Earth Leakage Detector  
Product Specification  
9. Typical Performance Curves  
PS030402-0212  
P R E L I M I N A R Y  
6
ZGFI7101 Earth Leakage Detector  
Product Specification  
10.Test Circuit  
PS030402-0212  
P R E L I M I N A R Y  
7
ZGFI7101 Earth Leakage Detector  
Product Specification  
PS030402-0212  
P R E L I M I N A R Y  
8
ZGFI7101 Earth Leakage Detector  
Product Specification  
11.Typical Application  
PS030402-0212  
P R E L I M I N A R Y  
9
ZGFI7101 Earth Leakage Detector  
Product Specification  
12.Package Dimensions  
8DIP  
8SOP  
PS030402-0212  
P R E L I M I N A R Y  
10  
ZGFI7101 Earth Leakage Detector  
Product Specification  
11  
Customer Support  
To share comments, get your technical questions answered, or report issues you may be  
experiencing with our products, please visit Zilog’s Technical Support page at  
http://support.zilog.com.  
To learn more about this product, find additional documentation, or to discover other fac-  
ets about Zilog product offerings, please visit the Zilog Knowledge Base or consider par-  
ticipating in the Zilog Forum.  
This publication is subject to replacement by a later edition. To determine whether a later  
edition exists, please visit the Zilog website at http://www.zilog.com.  
PS030402-0212  
P R E L I M I N A R Y  
Customer Support  

相关型号:

ZGFI7101PBT

High Gain Differential Amplifier
ZILOG

ZGFM0510C-MH

SURFACE MOUNT ZENER TYPE
PACELEADER

ZGFM0511C-MH

SURFACE MOUNT ZENER TYPE
PACELEADER

ZGFM0512C-MH

SURFACE MOUNT ZENER TYPE
PACELEADER

ZGFM0513C-MH

SURFACE MOUNT ZENER TYPE
PACELEADER

ZGFM0515C-MH

SURFACE MOUNT ZENER TYPE
PACELEADER

ZGFM0516C-MH

SURFACE MOUNT ZENER TYPE
PACELEADER

ZGFM0518C-MH

SURFACE MOUNT ZENER TYPE
PACELEADER

ZGFM0520C-MH

SURFACE MOUNT ZENER TYPE
PACELEADER

ZGFM0522C-MH

SURFACE MOUNT ZENER TYPE
PACELEADER

ZGFM0524C-MH

SURFACE MOUNT ZENER TYPE
PACELEADER

ZGFM0527C-MH