MIL-PRF-19500/394G
4.4.2.2 Group B inspection, (JAN, JANTX, and JANTXV). Separate samples may be used for each step. In the
event of a group B failure, the manufacturer may pull a new sample at double size from either the failed assembly lot
or from another assembly lot from the same wafer lot. If the new “assembly lot” option is exercised, the failed
assembly lot shall be scrapped.
Subgroup
1
Method
1039
Condition
Steady-state life: Test condition B, 340 hours min., VCB = 10 - 30 V dc, power
shall be applied to achieve TJ = +150°C minimum using a minimum of PD = 75
percent of maximum rated PT as defined in 1.3. n = 45 devices, c = 0.
2
3
1039
1032
The steady-state life test of step 1 shall be extended to 1,000 hrs for each die
design. Samples shall be selected from a wafer lot every twelve months of wafer
production. Group B step 2 shall not be required more than once for any single
wafer lot. n = 45, c = 0.
High-temperature life (non-operating), t = 340 hours, TA = +200°C. n = 22, c = 0.
4.4.2.3 Group B sample selection. Samples selected from group B inspection shall meet all of the following
requirements:
a. For JAN, JANTX, and JANTXV samples shall be selected randomly from a minimum of three wafers (or
from each wafer in the lot) from each wafer lot. For JANS, samples shall be selected from each inspection
lot. See MIL-PRF-19500.
b. Must be chosen from an inspection lot that has been submitted to and passed group A, subgroup 2,
conformance inspection. When the final lead finish is solder or any plating prone to oxidation at high
temperature, the samples for life test (subgroups B4 and B5 for JANS, and group B for JAN, JANTX, and
JANTXV) may be pulled prior to the application of final lead finish.
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table VII of MIL-PRF-19500, and in 4.4.3.1 (JANS).and 4.4.3.2 (JAN, JANTX, and
JANTXV) herein for group C testing. Electrical measurements (end-points) and delta requirements shall be in
accordance with table I, group A, subgroup 2 and 4.5.3 herein, delta measurements apply to subgroup C6.
4.4.3.1 Group C inspection, table VII (JANS) of MIL-PRF-19500.
Subgroup
C2
Method
2036
Condition
Test condition E.
C6
1026
1,000 hours at VCB = 10 V dc; power shall be applied to achieve TJ = +150°C
minimum and a minimum of PD = 75 percent of maximum rated PT as defined in
1.3.
4.4.3.2 Group C inspection, table VII (JAN, JANTX, and JANTXV) of MIL-PRF-19500.
Subgroup
C2
Method
2036
Condition
Test condition E.
*
C5
C6
3131
See 4.5.2, R
.
qJC
Not applicable.
10