TRJ Series
Professional Tantalum Chip Capacitor
QUALIFICATION TABLE
TRJ professional series (Temperature range -55ºC to +125ºC)
Characteristics
TEST
Condition
Visual examination
DCL
ΔC/C
DF
no visible damage
Apply rated voltage (Ur) at 85ºC and / or category
voltage (Uc) at 125ºC for 2000 hours through a circuit
impedance of ≤0.1Ω/V. Stabilize at room temperature for
1-2 hours before measuring.
1.25 x initial limit
within ±10% of initial value
initial limit
1.25 x initial limit
no visible damage
1.25 x initial limit
within ±10% of initial value
initial limit
Endurance
ESR
Visual examination
DCL
Store at 125ºC, no voltage applied, for 2000 hours.
Stabilize at room temperature for 1-2 hours before
measuring.
ΔC/C
Storage Life
Humidity
DF
ESR
1.25 x initial limit
no visible damage
1.5 x initial limit
Visual examination
DCL
Store at 65ºC and 95% relative humidity for 500 hours,
with no applied voltage. Stabilize at room temperature
and humidity for 1-2 hours before measuring.
ΔC/C
within ±10% of initial value
1.2 x initial limit
DF
ESR
1.25 x initial limit
no visible damage
2 x initial limit
Visual examination
DCL
ΔC/C
DF
Apply rated voltage (Ur) at 85ºC, 85% relative humidity
for 1000 hours. Stabilize at room temperature and
humidity for 1-2 hours before measuring.
within ±10% of initial value
1.2 x initial limit
Biased Humidity
ESR
1.25 x initial limit
Step
Temperature°C
Duration(min)
+20ºC
IL*
-55ºC
n/a
+20ºC
IL*
+85ºC
+125ºC
+20ºC
IL*
1
2
3
4
5
6
+20
-55
+20
+85
+125
+20
15
15
15
15
15
15
DCL
ΔC/C
DF
10 x IL* 12.5 x IL*
Temperature
Stability
n/a
+0/-10%
1.5 x IL*
±5%
IL*
+10/-0% +12/-0%
±5%
IL*
IL*
1.5 x IL*
2 x IL*
ESR
1.25 x IL* 2.5 x IL* 1.25 x IL* 1.25 x IL* 1.25 x IL* 1.25 x IL*
no visible damage
initial limit
Visual examination
Apply 1.3x category voltage (Uc) at 125ºC for 1000
cycles of duration 6 min (30 sec charge, 5 min 30 sec
discharge) through a charge / discharge resistance of
1000Ω
DCL
ΔC/C
within ±5% of initial value
initial limit
Surge Voltage
DF
ESR
1.25 x initial limit
Visual examination
no visible damage
initial limit
DCL
Mechanical
Shock
MIL-STD-202, Method 213, Condition F
MIL-STD-202, Method 204, Condition D
ΔC/C
within ±5% of initial value
initial limit
DF
ESR
1.25 x initial limit
Visual examination
no visible damage
initial limit
DCL
ΔC/C
DF
within ±5% of initial value
initial limit
Vibration
ESR
1.25 x initial limit
*Initial Limit
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or
available online at www.avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
103
040120