MODEL: KEPF
■ OPERATION DIAGRAM (example)
/C02: Polyurethane coating
/C03: Rubber coating
• Negative in lag, positive in lead
TERMINAL SCREW MATERIAL
/S01: Stainless steel
OUT
20mA
OUT
+10V
12
4
0
GENERAL SPECIFICATIONS
Construction: Plug-in
-10V
0.5
(Lag)
1
0.5
(Lead)
0.5
(Lag)
1
0.5
(Lead)
Connection: M3.5 screw terminals
Screw terminal: Chromated steel (standard) or stainless
steel
• Negative in lead, positive in lag
OUT
20mA
OUT
+10V
Housing material: Flame-resistant resin (black)
Isolation: Voltage input to current input to output to
auxiliary power
12
4
0
Computation: Phase angle detection
Overrange output: Approx. -10 to +120 % at 1 – 5 V
Zero adjustment: -5 to +5 % (front)
Span adjustment: 95 to 105 % (front)
-10V
0.5
(Lag)
0.5
(Lag)
1
0.5
(Lead)
1
0.5
(Lead)
Note: When there is no input voltage or 5% or less of rated
input current , the output may become unstable (hunting).
INPUT SPECIFICATIONS
A device which employs different measuring methods may
show different outputs from that of M-System's.
Frequency: 50 or 60 Hz
INSTALLATION
Auxiliary power supply
• Voltage Input
•AC: Operational voltage range: rating -15/+10 %,
50/60 Hz, approx. 2 VA
Input burden: 0.5 VA
Operational range: 85 – 120 % of rating
Overload capacity: 150 % of rating for 10 sec., 120 %
continuous
•DC: Operational voltage range: rating ±10 %,
or 85 – 150 V for 110 V rating, ripple 10 %p-p max.,
approx. 2 W (18 mA at 110 V)
• Current Input
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 85 %RH (non-condensing)
Mounting: Surface or DIN rail
Input burden:
0.1 VA (input 1 A)
0.5 VA (input 5 A)
Weight: 400 g (0.88 lb)
Operational range: 10 – 120 % of rating
Overload capacity: 1000 % of rating for 3 sec., 200 % for 10
sec., 120 % continuous
PERFORMANCE in percentage of span
Accuracy: ±2 % with input 1 – 0.866, balanced load
±4 % with input 0.866 – 0.5, balanced load (at 23°C ±10°C
or 73.4°F ±18°F, 45 – 65 Hz)
■ Input range:
Lag 0.5 – 1 – lead 0.5
Lead 0.5 – 1 – lag 0.5
Response time: ≤ 2 sec. (0 – 100 % ±1 %)
Ripple: 0.5 %p-p max.
OUTPUT SPECIFICATIONS
■ DC Current: 0 – 20 mA DC and ± 1 mA
Minimum span: 1 mA
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 2000 V AC @ 1 minute
(voltage input to current input to output to auxiliary power
to ground)
Offset: Max. 1.5 times span
Load resistance: Output drive 12 V max.
■ DC Voltage: -10 – +12 V DC
Minimum span: 5 mV
Impulse withstand voltage: 1.2 / 50 μsec., ±5 kV
(input to output or ground)
Offset: Max. 1.5 times span
Load resistance: Output drive 1 mA max. at ≥ 0.5 V
KEPF SPECIFICATIONS
ES-3668 Rev.5 Page 2/4
http://www.m-system.co.jp/