TCS-75-R/K

更新时间:2024-10-08 23:03:32
品牌:MSYSTEM
描述:Plug-in Signal Conditioners M-UNIT

TCS-75-R/K 概述

Plug-in Signal Conditioners M-UNIT

TCS-75-R/K 数据手册

通过下载TCS-75-R/K数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
MODEL: TCS  
4: J (IC) (Usable range -210 to +1200°C, -346 to +2192°F)  
5: T (CC) (Usable range -270 to +400°C, -454 to +752°F)  
6: B (RH) (Usable range 0 to 1820°C, 32 to 3308°F)  
7: R (Usable range -50 to +1760°C, -58 to +3200°F)  
8: S (Usable range -50 to +1760°C, -58 to +3200°F)  
N: N (Usable range -270 to +1300°C, -454 to +2372°F)  
0: Specify  
Plug-in Signal Conditioners M-UNIT  
THERMOCOUPLE TRANSMITTER  
Functions & Features  
• Accepting direct input from a thermocouple and providing  
a standard process signal  
• 7-segment linearization  
• Burnout protection  
[2] OUTPUT  
Current  
• High-accuracy cold junction compensation  
• Isolation up to 2000 V AC  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
• Fast response type available  
• LCD meter (engineering unit display selectable)  
• Simple loop test output (0 % and 100 %)  
• High-density mounting  
Typical Applications  
• High-accuracy cold junction compensation benefits narrow  
span measurements  
• 0.1 μA burnout sensing enables long distance  
transmission with minimum offset drifts  
• Electric furnace (isolation)  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 100 Ω min.)  
4: 0 – 10 V DC (Load resistance 1000 Ω min.)  
5: 0 – 5 V DC (Load resistance 500 Ω min.)  
6: 1 – 5 V DC (Load resistance 500 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
• No burnout type can connect to a single T/C in parallel  
with a recorder  
• Power plant (2000 V AC isolation, 110 V DC power supply)  
50  
(1.97)  
[3] POWER INPUT  
AC Power  
80  
(3.15)  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
127  
(5)  
F: 120 V AC  
mm (inch)  
G: 200 V AC (Not selectable with Option /UL)  
H: 220 V AC (Not selectable with Option /UL)  
J: 240 V AC (Not selectable with Option /UL)  
DC Power  
MODEL: TCS–[1][2]–[3][4]  
S: 12 V DC (Not selectable with Option /UL)  
R: 24 V DC (Not selectable with Option /UL)  
V: 48 V DC (Not selectable with Option /UL)  
P: 110 V DC (Not selectable with Option /E2 or /UL)  
ORDERING INFORMATION  
• Code number: TCS-[1][2]-[3][4]  
Specify a code from below for each of [1] through [4].  
(e.g. TCS-2A-B/E2/BL/Q)  
• Temperature range (e.g. 0 – 800°C)  
• Special output range (For codes Z & 0)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
[4] OPTIONS (multiple selections)  
Input Signal Indicator  
blank: Without  
/E: With (0.0 - 100.0 % display)  
/E2: With (in engineering unit with backlight and the  
simple loop test output)  
[1] INPUT THERMOCOUPLE  
1: (PR) (Usable Range 0 to 1760°C, 32 to 3200°F)  
2: K (CA) (Usable range -270 to +1370°C, -454 to +2498°F)  
3: E (CRC) (Usable range -270 to +1000°C, -454 to +1832°F)  
Response Time (0 – 90 %)  
blank: Standard (≤ 0.5 sec.)  
/K: Fast response (Approx. 25 msec.)  
TCS SPECIFICATIONS  
ES-1331-E Rev.16 Page 1/4  
http://www.m-system.co.jp/  
MODEL: TCS  
(Not selectable with Option /E2)  
Burnout  
INPUT SPECIFICATIONS  
Minimum span: 3 mV  
blank: Upscale burnout  
Offset: Max. 1.5 times span  
Input resistance: 30 kΩ min.  
Burnout sensing: 0.1 μA  
/BL: Downscale burnout  
/BN: No burnout  
Standards & Approvals  
blank: Without UL  
Minimum span (in °C)  
(PR): min. span 370°C  
K (CA): min. span 75°C  
E (CRC): min. span 50°C  
J (IC): min. span 60°C  
T (CC): min. span 75°C  
B (RH): min. span 780°C  
R: min. span 360°C  
/UL: UL approval (Not selectable with /E or /E2)  
Other Options  
blank: none  
/Q: Option other than the above (specify the specification)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
S: min. span 380°C  
N: min. span 110°C  
/C02: Polyurethane coating  
/C03: Rubber coating (UL not available)  
TERMINAL SCREW MATERIAL  
Minimum span (in °F)  
(PR): min. span 670°F  
K (CA): min. span 140°F  
E (CRC): min. span 90°F  
J (IC): min. span 110°F  
T (CC): min. span 140°F  
B (RH): min. span 1410°F  
R: min. span 650°F  
/S01: Stainless steel (UL not available)  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Connection: M3.5 screw terminals  
Screw terminal: Chromated steel (standard) or stainless  
steel  
S: min. span 690°F  
Housing material: Flame-resistant resin (black)  
Isolation: Input to output to power  
N: min. span 200°F  
Overrange output: Approx. -10 to +120 % at 1 – 5 V  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
At burnout: Downscale ≤ -10 %, Upscale ≥ 110 %  
Linearization: Standard  
Note: The described accuracy may be partially not satisfied  
when the temperature ranges below 0°C. Consult factory.  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Cold junction compensation: CJC sensor attached to the  
input terminals (B thermocouple is without CJC as standard)  
Simple loop test output: 0 % and 100 % signal simulated by  
selecting the front switch positions. (Only for option code  
/E2)  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
Load resistance: Output drive 15 V max.  
DC Voltage: -10 – +12 V DC  
Minimum span: 5 mV  
■ DISPLAY (Input indicator)  
Offset: Max. 1.5 times span  
• Option code: /E  
Load resistance: Output drive 10 mA max.; 5 mA for  
negative voltage output; at ≥ 0.5 V  
LCD digital display: 0.0 - 100.0 % (min. digit 0.1 %)  
(No scaling)  
• Option code: /E2  
LCD digital display: Engineering unit  
Display scaling: -10000 – +10000  
INSTALLATION  
Power input  
Decimal position: 10-1 - 10-4 or no decimal point  
Engineering unit: %, μV, mV, V, mA, A, °C, °F, Ω, DEG K,  
mHz, Hz, kHz, VAC, AAC, mg, g, kg, t, rpm or rps selectable  
Back light: Green at normal, red at loop test output enable  
Factory setting: scaling 0.00 - 100.00, unit: %  
AC: Operational voltage range: rating ±10 %, 50/60 ±2 Hz,  
approx. 2 VA  
(approx. 3 VA with Option /E2)  
DC: Operational voltage range: rating ±10 %, or 85 – 150 V  
for 110 V rating (ripple 10 % p-p max.) approx. 2.6 W (110  
mA at 24 V; approx. 3.6 W with Option /E2)  
Operating temperature: -5 to +60°C (23 to 140°F)  
TCS SPECIFICATIONS  
ES-1331-E Rev.16 Page 2/4  
http://www.m-system.co.jp/  
MODEL: TCS  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Weight: 350 g (0.77 lb)  
PERFORMANCE in percentage of span  
Accuracy: ±0.3 % (at over 400°C or 750°F for R, S  
and PR; over 770°C or 1420°F for B)  
Display accuracy: ± (0.3 % of FS + 1 digit) (at over 400°C or  
750°F for R, S and PR; over 770°C or 1420°F for B)  
Simple loop test output setting accuracy: ±0.5 %  
Cold junction compensation error  
(at 20°C ±10°C or 68°F ±18°F)  
K, E, J, T & N: ±0.5°C or ±0.9°F  
S, R & PR: ±1°C or ±1.8°F  
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)  
(at over 400°C or 750°F for R, S and PR; over 770°C or  
1420°F for B)  
Burnout response: ≤ 10 sec.  
Line voltage effect: ±0.1 % over voltage range  
Insulation resistance: ≥ 100 MΩ with 500 V DC  
Dielectric strength: 2000 V AC @1 minute (input to output  
to power to ground)  
STANDARDS & APPROVALS  
Approval:  
UL/C-UL general safety requirements  
(UL 3111-1, CAN/CSA-C22.2 No.1010-1)  
EXTERNAL VIEW  
OPTION /E  
OPTION /E2  
LCD Meter  
Zero Adj.  
Span Adj.  
LCD Meter  
Zero Adj.  
Span Adj.  
NEXT Key  
Loop Test Selector  
ENTER Key  
Top  
: 0% fixed  
Middle : 100% fixed  
Bottom : Cancel  
(normal operating mode)  
TCS SPECIFICATIONS  
ES-1331-E Rev.16 Page 3/4  
http://www.m-system.co.jp/  
MODEL: TCS  
EXTERNAL DIMENSIONS unit: mm (inch)  
CLAMP  
(top & bottom)  
7.8 (.31)  
DIN RAIL  
35mm wide  
6
5
4
3
2–4.5 (.18) dia.  
MTG HOLE  
15 (.59) deep  
7
8
1
2
8–M3.5  
SCREW  
50 (1.97)  
107 (4.21)  
127 (5)  
40 (1.57)  
50 (1.97)  
[3.3 (.13)]  
• When mounting, no extra space is needed between units.  
TERMINAL ASSIGNMENTS unit: mm (inch)  
CJC SENSOR  
(model: CJM)  
6
3
5
8
4
1
7
2
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM  
*
comp. leadwire  
T / C  
Z
S
Isolation  
+
Low Drift  
Amplifier  
Output  
Driver  
+
+
3
Linearizer  
1
2
OUTPUT  
POWER  
***  
metal leg  
LOOP TEST  
SELECTOR  
4
5
6
CJC  
SENSOR  
**  
U(+)  
V(–)  
7
8
CJC Sensing  
Volt. Generator  
model: CJM  
Base Socket  
*
Option /E, E2  
** Deleted with B thermocouple  
***Option /E2  
Specifications are subject to change without notice.  
TCS SPECIFICATIONS  
ES-1331-E Rev.16 Page 4/4  
http://www.m-system.co.jp/  

TCS-75-R/K 相关器件

型号 制造商 描述 价格 文档
TCS-75-R/Q MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
TCS-75-S MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
TCS-75-S/BL MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
TCS-75-S/BN MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
TCS-75-S/CE MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
TCS-75-S/E MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
TCS-75-S/K MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
TCS-75-S/Q MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
TCS-75-V MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格
TCS-75-V/BL MSYSTEM Plug-in Signal Conditioners M-UNIT 获取价格

TCS-75-R/K 相关文章

  • BENCENT(槟城电子)产品选型手册
    2024-10-11
    7
  • BECKHOFF(倍福)产品选型手册(中文版)
    2024-10-11
    3
  • BOOKLY(百力微)产品选型手册
    2024-10-11
    6
  • BALLUFF(巴鲁夫)产品选型手册
    2024-10-11
    6