RAG 系列耐脈衝厚膜晶片電阻器規格標準書(車用等級)
IE-SP-116
Specifications規格
Item
Conditions
項目
條件
Resistors
Put the specimens on the test fixture and two
△R=±3.0%
(2)discharges (3KVDC) shall be applied to each PUT,
one (1) with a positive polarity and one (1) with a negative
polarity. Afterwards, the specimens stabilize for 30min or
more and measure of its resistance variance rate. The
test is performed with direct contact and regular
discharge mode. The resistor and capacitor used on the
spearhead is 2000Ω and 150pF respectively.
ESD
Experiment evidence AEC-Q200
Test method:
Test item 1 (solder pot test): Method B
Precondition:
1. Soldering coverage over 95%
2. At the edge of terminal, the object
underneath (e.g. white ceramic) shall
not expose.
The specimens are subjected to 155℃ dry bake for
4hrs±15min.
The specimens are immersed into the flux first, then fully
immersed into the solder pot, at a temperature of
235± 5℃ for 5+0/-0.5 sec. Then rinse with water and
observe the soldering coverage under the microscope.
Test item 2 (Leaching test): Method D
The specimens are immersed into the flux first, then fully
immersed into the solder pot, at a temperature of
260±5℃ for 30+0/-0.5 sec. Then rinse with water and
observe the soldering coverage under the microscope.
Solderability
Experiment evidence AEC-Q200
(R2-R1)
Refer to item 3. general specifications
TCR൫ppm/℃൯=
×106
R1(T2-T1)
R1: Resistance at room temperature (Ω)
R2: Resistance at -55℃ or +125℃(Ω)
T1: Room temperature (℃)
Electrical
Characterization
T2: Temperature -55℃ or +125℃.
Experiment evidence: AEC-Q200
Solder the specimens on the test PCB and put the PCBA △R=±1.0%
onto the Bending Tester. Add force at the central part of
PCB, and the duration of the applied forces shall be
60 (+ 5) Sec. Measure of its resistance variance rate in
load.
Bending depth
(D)RAG02、03、05=5mm
No mechanical damage, peel-off of side
end or chip crack.
Board Flex
(Bending Test)
RAG06、12=3mm
RAG20、25=2mm
Experiment evidence: AEC-Q200
Put the tested resistor in sulfur vapor, at a △R=±4.0%
temperature of 60±2℃for 1000hrs
Refer to ASTM-B-809-95&EIA977
Refer to item 3.
general
specification
Sulfuration
Test
Class:A
6
www.ralec.com