V10
TRE25 Series Derating Curve
Specifications
INPUT SPECIFICATIONS:
Voltage …....………........…........................................... 90~264Vac
Frequency ………………………………………….……………..... 47 to 63Hz
Input Current ………………….……………................... 0.7A max.
Inrush Current ………………….……………................... 60A max. @240Vac
Conducted EMI …………………………….…………... CISPR/FCC Class B
Leakage Current …………………………………………………. 0.25mA max.
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 10ms typ. @115Vac
Short Circuit Protection …………….…………… Continuous(Auto Recovery)
Over Voltage Protection ………………. ............... IC Component to Clamp
Temperature Coefficient ……………………............................… 0.05%/℃
GENERAL SPECIFICATIONS:
SAFETY AND EMC:
Isolation ………………………………….…..…… Input to output = 3,000VAC
Emission and lmmunity ……….… EN55022 Class B, FCC Part 15 Class B
EN61000-6-3, EN61000-3-2, EN61000-3-3
℃
Operating Temperature .................................. -20~60 (see derating curve)
EN55024, EN61204-3, EN61000-6-1
℃
Storage Temperature ………………….…………...….......……........ -20~85
Humidity …………………...….......…........... 93% RH max. Non condensing
Cooling ………………………………….………………….. Natural Convection
Switching Frequency ………………………….……………….. 65KHz typ.
Safety ………………….…… Class II, IEC60950-1, EN60950-1, UL60950-1
NOTE:
1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
ripple & noise measuring @20MHz BW.
℃
MTBF …….… MIL-HDBK-217F, GB, 25 /115VAC ……….. 300K hrs min.
Altitude …………………………………………………………………… 2000m
Life time …….… Ambient 40degC 75% Load …………………..…… >3years
Dimensions ……….……. 2.795x1.906x1.299Inches (71.00x48.4x33.00mm)
Weight …………………..…………………………….…… 140g(0.31 Pounds)
2. Voltage setpoint at 60% full load.
3. Line regulation measured from 100Vac to 240Vac, full load.
4. Load regulation measured from 60% to 100% full load and from 60% to
20% load (60% +/- 40% full load).
Mechanical Specification
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified