54239151.121

更新时间:2025-06-11 15:33:35
品牌:SCHURTER
描述:Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT

54239151.121 概述

Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT 电源连接器

54239151.121 规格参数

是否Rohs认证: 符合生命周期:Active
包装说明:ROHS COMPLIANTReach Compliance Code:compliant
风险等级:5.72其他特性:STANDARDS: IEC/EN 60320-1/C14, UL 94V-0; UL 498, CSA C22.2, VDE
连接器类型:MAINS POWER CONNECTOR联系完成配合:NOT SPECIFIED
联系完成终止:TIN/TIN COPPER触点性别:MALE
触点材料:NOT SPECIFIED耦合类型:SNAP
DIN 符合性:NOIEC 符合性:YES
JESD-609代码:e3/e2MIL 符合性:NO
电源连接器额定值:10A, 250VAC插接信息:MULTIPLE MATING PARTS AVAILABLE
安装类型:PANEL选件:GENERAL PURPOSE
外壳材料:POLYETHYLENE端接类型:SOLDER
触点总数:3Base Number Matches:1

54239151.121 数据手册

通过下载54239151.121数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
Power Entry Modules with Line Filter  
Felcom 54  
www.schurter.com/pg06  
IEC Appliance Inlet C14 Modular Assembling Options  
Standard- or Medical-Filter  
5411.XX5X.XXX  
Appliance inlet  
Fuseholder  
5431.X05X.XXX  
Appliance inlet  
Appliance outlet  
Switch  
Line filter  
Line filter  
C14  
F
70° C  
70° C  
Description  
-ꢀPanelꢀMount:  
Characteristics  
-ꢀModularꢀcomponentꢀselection  
-ꢀIndividualꢀcomponentsꢀsolderedꢀonꢀaꢀprintedꢀcircuitꢀboard  
-ꢀPlugꢀremovalꢀnecessaryꢀforꢀfuse-linkꢀreplacement  
ꢀ FuseꢀdrawerꢀmeetsꢀrequirementsꢀofꢀmedicalꢀstandardꢀIEC/ENꢀ60601-1  
ꢀ Theꢀfuseholderꢀisꢀaccessibleꢀfromꢀtheꢀequipmentꢀfront  
-ꢀTechnicalꢀdataꢀofꢀfilter-componentsꢀseeꢀblockfilterꢀtypeꢀ5500  
-ꢀFullyꢀinsulatedꢀfromꢀtheꢀrear  
ꢀ Snap-inꢀversionꢀfromꢀfrontꢀsideꢀ  
-ꢀ2ꢀ-ꢀ5ꢀFunctions:  
ꢀ ApplianceꢀInletꢀProtectionꢀclassꢀI,ꢀConnector,ꢀLineꢀSwitchꢀ2-pole,ꢀFuse-  
holderꢀforꢀfuse-linksꢀ5ꢀxꢀ20ꢀmmꢀ1-ꢀorꢀ2-pole,ꢀLineꢀfilterꢀinꢀstandardꢀandꢀ  
medicalꢀversionꢀ  
-ꢀSolderꢀterminalsꢀ3.5ꢀxꢀ0.8ꢀmmꢀorꢀquickꢀconnectꢀterminalsꢀ6.3ꢀxꢀ0.8ꢀ  
mm  
-ꢀQualifiedꢀforꢀuseꢀinꢀequipmentꢀaccordingꢀIEC/ENꢀ60950  
Other versions on request  
Approvals  
-ꢀVDEꢀCertificateꢀNumber:ꢀ101307  
-ꢀULꢀFileꢀNumber:ꢀE72928  
-ꢀLineꢀswitchꢀwithꢀotherꢀrockerꢀmarking  
References  
Alternative:ꢀversionꢀwithoutꢀlineꢀfilterꢀꢀꢀFelcomꢀ64ꢀ  
Weblinks  
pdf,ꢀGeneralꢀProductꢀInformation,ꢀApprovals,ꢀRoHS,ꢀCHINA-RoHS,ꢀ  
MatingꢀConnectors,ꢀe-Store,ꢀSCHURTER-Stock-Check,ꢀDistributor-  
Stock-Check,ꢀAccessories  
Technical Data  
RatingsꢀIEC  
RatingsꢀUL/CSA  
LeakageꢀCurrent  
1ꢀ-ꢀ10Aꢀ@ꢀTaꢀ40ꢀ°Cꢀ/ꢀ250VAC;ꢀ50Hz  
1ꢀ-ꢀ10Aꢀ@ꢀTaꢀ40ꢀ°Cꢀ/ꢀ250VAC;ꢀ60Hz  
standardꢀ<ꢀ0.5mAꢀ(250Vꢀ/ꢀ60Hz)ꢀ  
medicalꢀ<ꢀ5ꢀµAꢀ(250ꢀVꢀ/ꢀ60ꢀHz)  
>ꢀ1.7kVDCꢀbetweenꢀL-Nꢀ  
>ꢀ2.7kVDCꢀbetweenꢀL/N-PEꢀ  
Testꢀvoltageꢀ(2sec)  
-25°Cꢀtoꢀ85°C  
25/085/21ꢀacc.ꢀtoꢀIECꢀ60068-1  
fromꢀfrontꢀsideꢀIPꢀ40ꢀacc.ꢀtoꢀIECꢀ60529  
Suitableꢀforꢀappliancesꢀwithꢀprotectionꢀ  
classꢀ1ꢀacc.ꢀtoꢀIECꢀ61140  
Solderꢀterminalsꢀ3.5ꢀxꢀ0.8ꢀmmꢀorꢀquickꢀ  
connectꢀterminalsꢀ6.3ꢀxꢀ0.8ꢀmm  
Snap-in:ꢀ1/1.2/1.5/2/2.5/3mm1/1.2/1.5  
/2/2.5/3ꢀmm  
Appliance-Inlet/-Outlet  
Fuseholder  
C14ꢀacc.ꢀtoꢀIEC/ENꢀ60320-1,ꢀ  
Fꢀacc.ꢀtoꢀIEC/ENꢀ60320-2-2,ꢀ  
ULꢀ498,ꢀCSAꢀC22.2ꢀno.ꢀ42ꢀ(forꢀcoldꢀ  
conditions)ꢀpin-temperatureꢀ70ꢀ°C,ꢀ10A,ꢀ  
ProtectionꢀClassꢀ1  
1ꢀorꢀ2ꢀpole,ꢀShocksafeꢀcategoryꢀPC2ꢀ  
acc.ꢀtoꢀIECꢀ60127-6,ꢀ  
forꢀfuse-linksꢀ5ꢀxꢀ20mm  
DielectricꢀStrength  
AllowableꢀOperationꢀTemp.  
ClimaticꢀCategory  
DegreeꢀofꢀProtection  
ProtectionꢀClass  
RatedꢀPowerꢀAcceptanceꢀ@ꢀ 5ꢀxꢀ20:ꢀ2Wꢀ(1ꢀpole)/ꢀ1.6Wꢀ(2-pole)ꢀperꢀ  
Taꢀ23ꢀ°C  
PowerꢀAcceptanceꢀ@ꢀTaꢀ>ꢀ  
23°C  
pole  
Admissibleꢀpowerꢀacceptanceꢀatꢀhig-  
herꢀambientꢀtemperatureꢀseeꢀderatingꢀ  
curves  
Rockerꢀswitchꢀ2-pole,ꢀnon-illuminated,ꢀ  
acc.ꢀtoꢀIECꢀ61058-1ꢀ  
Terminal  
LineꢀSwitch  
LineꢀFilter  
PanelꢀThicknessꢀs  
Material:ꢀHousing  
Technicalꢀdetails  
StandardꢀVersion,ꢀIECꢀ60939,ꢀIECꢀ  
60601-1,ꢀULꢀ1283,ꢀULꢀ544,ꢀENꢀ133ꢀ  
200,ꢀCSAꢀC22.2ꢀno.ꢀ8ꢀ  
Thermoplastic,ꢀblack,ꢀULꢀ94V-0  
Technicalꢀdetails  
MTBF  
>ꢀ1'400'000hꢀacc.ꢀtoꢀMIL-HB-217ꢀF  
EMC Products  
Power Entry Modules with Line Filter  
Felcom 54  
www.schurter.com/pg06  
Dimensions  
Variants 5411.XX5X.XXX  
Variants 5421.X05X.XXX  
Mounting Ø: 63+0,2 x 27.6+0,2  
Mounting Ø: 85.9+0,2 x 27.6+0,2  
Variants 5423.XX5X.XXX  
Variants 5424.XX5X.XXX  
Mounting Ø: 96.4+0,2 x 27.6+0,2  
Mounting Ø: 87.9+0,2 x 27.6+0,2  
Variants 5431.X05X.XXX  
Variants 5432.XX5X.XXX  
Mounting Ø: 111.1+0,2 x 27.6+0,2  
Mounting Ø: 121.6+0,2 x 27.6+0,2  
Technical Data of Filter-Components  
Rated Current  
[A]  
Filter-Type  
Inductances Capacitance Capacitance  
R [M]  
L [mH]  
CX [nF]  
CY [nF]  
1
2
Standard Version  
2 x 11  
2 x 4  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
2.2  
2.2  
2.2  
2.2  
2.2  
2.2  
-
-
-
Standard Version  
4
Standard Version  
2 x 1.6  
2 x 0.7  
2 x 0.6  
2 x 0.4  
2 x 11  
2 x 4  
-
6
Standard Version  
-
8
Standard Version  
-
10  
1
Standard Version  
-
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
1
1
1
1
1
1
2
-
4
2 x 1.6  
2 x 0.7  
2 x 0.6  
2 x 0.4  
-
6
-
8
-
10  
-
EMC Products  
Power Entry Modules with Line Filter  
Felcom 54  
www.schurter.com/pg06  
Diagrams  
5411  
5421  
5423  
5424  
1) Line  
2) Load 1  
1) Load 2  
2) Load 1  
1) Load 2  
2) Load 1  
1) Line  
2) Load 1  
5431  
5432  
1) Load 2  
2) Load 1  
1) Load 2  
2) Load 1  
Derating Curves  
1-pole  
2-pole  
2.0  
1.6  
1.4  
1.2  
1.0  
0.8  
0.6  
0.4  
1.5  
I = 1.0 In  
I = 1.0 In  
I = 0.7 In  
I = << In  
I = 0.7 In  
1.0  
I = << In  
0.5  
0.2  
0.0  
0.0  
0
0
20  
40  
60  
80  
100  
20  
40  
60  
80  
100  
Ambient air temperature Ta °C  
Ambient air temperature Ta °C  
Ordering instructions  
54 XX. X X XX.XX X  
Type of line filter  
1 = standard  
3 = medical  
“Snap-in” panel thickness  
10 = 1,0 mm  
12 = 1,2 mm  
15 = 1,5 mm  
20 = 2,0 mm  
25 = 2,5 mm  
30 = 3,0 mm  
Connection  
51 = solder terminals 3,5 x 0,8 mm  
53 = quick connect terminals 6,3 x 0,8 mm  
Fuseholder 5 x 20 mm  
0 = without fuseholder  
1 = 1-pole  
2 = 2-pole  
Line filter  
1 = 1 Amp.  
2 = 2 Amp.  
4 = 4 Amp.  
6 = 6 Amp.  
8 = 8 Amp.  
9 = 10 Amp.  
Module combination  
11 = Appliance inlet, fuseholder  
21 = Appliance inlet, appliance outlet  
23 = Appliance inlet, fuseholder, appliance outlet  
24 = Appliance inlet, fuseholder, switch  
31 = Appliance inlet, appliance outlet, switch  
32 = Appliance inlet, fuseholder, appliance outlet, switch  
Base model  
10ꢀPcsꢀ  
Packaging unit  
EMC Products  
Power Entry Modules with Line Filter  
Felcom 54  
www.schurter.com/pg06  
Accessories  
Description  
Cord retaining kits  
Cord retaining strain relief  
Flat head, A  
4700.0001  
Mating Inlets/Plugs  
Category / Description  
Interconnection CordOverview complete  
Interconnection Cord with IEC Plug E, Angled  
Interconnection Cord with IEC Plug E, Angled  
Interconnection Cord with IEC Plug E, Straight  
Interconnection Cord with IEC Plug G, Angled  
Interconnection Cord with IEC Plug G, Angled  
Interconnection Cordfurther types toFelcom 54  
0607  
0608  
0609  
607B  
608B  
...  
PlugOverview complete  
IEC Plug E, Cord Connector (Rewireable), Straight, max. cable Diameter 8.5 mm  
IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm  
IEC Plug E, Cord Connector (Rewireable), Straight, max. Cable Diameter 10 mm  
IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm  
IEC Plug E, Cord Connector (Rewireable), Straight  
4732  
4733  
4735  
4736  
9009  
...  
Plugfurther types toFelcom 54  
Mating Outlets/Connectors  
Appliance OutletOverview complete  
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal  
4787  
4788  
5091  
5092  
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal  
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal  
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal  
Appliance Outletfurther types toFelcom 54  
ConnectorOverview complete  
IEC Connector C15, Rewireable, Straight  
IEC Connector C15A, Rewireable, Straight  
IEC Connector C15A, Rewireable, Straight  
IEC Connector C15A, Rewireable, Angled  
IEC Connector C13, Rewireable, Angled  
Connectorfurther types toFelcom 54  
0101  
0102  
0102-G  
0112  
4012  
...  
Power CordOverview complete  
Power Cord with IEC Connector C13, Angled  
Power Cord with IEC Connector C13, Angled  
Power Cord with IEC Connector C13, Angled  
Power Cord with IEC Connector C13, Angled  
Power Cord with IEC Connector C13  
0311  
3011  
3012  
3013  
3020  
...  
Power Cordfurther types toFelcom 54  
Theꢀspecifications,ꢀdescriptionsꢀandꢀillustrationsꢀindicatedꢀinꢀthisꢀdocumentꢀareꢀbasedꢀonꢀ  
EMC Products  
currentꢀinformation.ꢀAllꢀcontentꢀisꢀsubjectꢀtoꢀmodificationsꢀandꢀamendments.  
4

54239151.121 相关器件

型号 制造商 描述 价格 文档
54239151.123 SCHURTER Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT 获取价格
54239151.151 SCHURTER Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT 获取价格
54239151.153 SCHURTER Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT 获取价格
54239151.201 SCHURTER Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT 获取价格
54239151.203 SCHURTER Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT 获取价格
54239151.251 SCHURTER Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT 获取价格
54239151.253 SCHURTER Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT 获取价格
54239151.301 SCHURTER Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT 获取价格
54239151.303 SCHURTER Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT 获取价格
54239153.103 SCHURTER Mains Power Connector, 10A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT 获取价格
Hi,有什么可以帮您? 在线客服 或 微信扫码咨询