P2
TAI-TECH
5. Specification
Inductance
L0 (uH)±20%
DCR(mΩ)
Typ.@25℃
DCR(mΩ)
Max.@25℃
Part Number
I rms ( A )
I sat ( A )
TMPC0312HV-R22MG
TMPC0312HV-R33MG
TMPC0312HV-R36MG
TMPC0312HV-R47MG
TMPC0312HV-R56MG
TMPC0312HV-R68MG
TMPC0312HV-R82MG
TMPC0312HV-1R0MG
TMPC0312HV-1R5MG
TMPC0312HV-2R2MG
TMPC0312HV-3R3MG
TMPC0312HV-4R7MG
TMPC0312HV-5R6MG
TMPC0312HV-6R8MG
TMPC0312HV-8R2MG
TMPC0312HV-100MG
0.22
0.33
0.36
0.47
0.56
0.68
0.82
1.00
1.50
2.20
3.30
4.70
5.6
6.5
6.2
6.0
5.0
4.5
4.0
3.5
3.3
3.0
2.7
2.0
1.6
1.5
1.4
1.2
1.0
10
14
16
17
20
9.2
8.5
7.2
6.6
6.1
5.8
5.5
4.0
3.4
3.1
2.8
2.2
2.0
1.7
1.4
18.5
25
23
30
31
36
34
40
41
48
50
60
71
85
98
115
210
293
360
400
463
550
191
266
310
360
420
498
6.80
8.20
10.0
Note:
1. Test frequency : Ls : 100KHz /1.0V.
2. All test data referenced to 25℃ ambient.
3. Testing Instrument(or equ) : L: HP4284A,CH11025,CH3302,CH1320,CH1320S LCR METER / Rdc:CH16502,Agilent33420A MICRO OHMMETER.
4. Heat Rated Current (Irms) will cause the coil temperature rise approximately ΔT of 40℃
5. Saturation Current (Isat) will cause L0 to drop approximately 30%.
6. The part temperature (ambient + temp rise) should not exceed 125℃under worst case operating conditions.Circuit design,component,PCB trace size and
thickness,airflow and other cooling provisions all affect the part temperature. Part temperature should be verified in the end application.
7. Special inquiries besides the above common used types can be met on your requirement.