Crystal Filter  
IXF Series  
3 Lead Metal Package  
Frequency Range (MHz)  
3 dB Bandwidth  
Insertion loss  
10 MHz to 120 MHz  
±2 KHz to ±20 KHz, See Table  
1.5 dB to 6 dB, depends on frequency and number of poles  
-35 dB to -80 dB, depends on frequency and number of poles  
AT Cut  
Ultimate Rejection  
Crystal Cut  
Aging  
±5 ppm Max. / Year Standard  
Temperature  
Operating  
-20° C to +70° C Standard  
-40° C to +85° C Standard  
Storage  
See Appendix B for information  
Environmental  
Package Information  
MSL = N.A., Termination, UM1 = e4  
Termination, HC49U = e1  
Surface mount and filter module packages are also available, contact ILSI America.  
Part Number Guide  
Sample Part Number:  
Package  
IXF - 10A15AA  
Bandwidth  
Filter  
Frequency **  
Polls  
Mode  
Impedance  
IXF -  
10 = 10.7 MHz  
21 = 21.4 MHz  
A = HC49U  
B = UM1  
A = 2 Pole  
B = 4 Pole *  
C = 6 Pole *  
D = 8 Pole *  
F = Fundamental  
T = 3rd Overtone ***  
**  
2 = ±2 KHz  
3 = ±3 KHz  
45 = 45.0 MHz  
C = UM4  
4 = ±3.75 KHz  
6 = ±6 KHz  
55 = 55.025 MHz  
56 = 55.845 MHz  
58 = 58.1125 MHz  
70 = 70.000 MHz  
90 = 90.000 MHz  
D = UM5  
7 = ±7.5 KHz  
8 = ±8.5 KHz  
15 = ±15 KHz  
20 = ±20 KHz  
* - 2 poles per package, 4 / 6 / 8 poles are matched sets..  
** - Contact ILSI America for additional options.  
*** - Available at 30 MHz and above.  
ILSI America Phone: 775-851-8880 • Fax: 775-851-8882• e-mail: e-mail@ilsiamerica.com • www.ilsiamerica.com  
12/06  
Specifications subject to change without notice  