SAW Bandpass Filter F1G99
Specifications
Fc = 1962.5 MHz
Minimum
Typical
1962.5
2.6
Maximum
Unit
MHz
dB
Center Frequency ( Fc )
-
-
-
-
-
Insertion Loss (In Fc +/- 32.5 MHz)
Amplitude Ripple (In Fc +/- 32.5 MHz)
VSWR (In Fc +/- 32.5 MHz)
3.8
2.3
2.5
1.4
dB
2.0
Attenuation (Reference level from 0dB)
1710.0 MHz ~ 1755.0 MHz
1855.0 MHz ~ 1915.0 MHz
2010.0 MHz ~ 2020.0 MHz
10
5
32
11
8
-
-
-
dB
5
℃
Temperature Range (Operational)
Input/Output Impedance
-20
25
50
70
Ohms
Notes :
1) All specifications are based on the matching schematic shown below, measured by Agilent Network analyzer and
full 2 port calibration.
2) Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing
tolerances
3) All attenuation measurements are measured relative to insertion loss
Part No.
Rev. Date
Rev.
F1G99
I T F Co., Ltd.
102-901, Bucheon Technopark 364,
Samjeong-Dong, Ojeong-Gu, Bucheon-City,
Gyounggi-Do, Korea 421-809
2010-06-15
NCLD04-AS01
2/7