ISOLATED DC/DC CONVERTERS  
48 VDC Input 9.3VDC/36.5 A Output, 1/4 Brick  
07CM-38S10L  
RoHS 5 Compliant  
Rev.B  
Industry standard quarter-brick package  
Up to 300 W at 95% efficiency  
1500 V isolation  
Safety Agency Approvals  
Description  
The 07CM-38S “Cimarron” Series are isolated DC/DC converters that  
operate from a nominal 48 VDC source. These converters use a full bridge power train to provide isolation and  
step down. These units will provide up to 300 W of output power from a nominal 54 VDC input. These units are  
designed to be highly efficient and low cost. Features include remote on/off, over current protection and under  
voltage lockout. These converters are provided in an industry standard quarter -brick package.  
Part Selection  
Output  
Input Voltage  
Max. Output  
Current  
Max. Output  
Power  
Typical  
Efficiency  
Model Number  
Voltage  
9.3 Vdc  
48 Vdc  
36.5 A  
300 W  
95%  
07CM-38S10L  
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.  
2. All part numbers above indicate RoHS 5. Change the second letter "7" to "R" for RoHS 6 part numbers.  
Input Specifications  
Parameter  
Min  
Typ  
Max  
Notes  
Input Voltage Range  
36 V  
-
55 V  
Input Current (no load)  
Input Current (full load)  
Reflected Ripple Current (rms)  
-
-
-
-
-
-
110 mA  
7.2 A  
200 mA  
See figure 1 for measurement technique  
Under-voltage Lockout  
Turn-on  
-
-
35.8 V  
33.8 V  
-
-
Turn off  
Over-voltage Lockout  
-
57.1 V  
-
Output Specifications  
Parameter  
Output Voltage  
36Vin  
Min  
Typ  
Max  
Notes  
-
-
-
7.0 V  
9.3 V  
10.6 V  
-
-
-
48Vin  
55Vin  
Setpoint at no load.  
Output Current  
Output Power  
Load Regulation  
0 A  
-
-
-
36.5 A  
300 W  
0.55 V  
-
-
0 to 20 MHz Bandwidth, use 1.0 uF ceramic  
cap and 100 uF/50mOhm tantalum on  
output  
Ripple and Noise (pk-pk)  
-
-
-
150 mV  
3000 uF  
100 uF  
(50mohm)  
Load Capacitance  
Transient Response  
Max deviation  
di/dt =0 .1 A/uS, Vin =48 V  
Ta = 25 °C, 25% load change.  
-
-
150 mV  
50 uS  
250 mV  
100 uS  
Recovery to within ± 1%  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
48 VDC Input 9.3VDC/36.5 A Output, 1/4 Brick  
General Specifications  
Min  
Typ  
Max  
Notes  
Parameter  
Switching Frequency  
Weight  
-
96 kHz  
-
fixed  
-
56 g (2.0oz)  
-
Operating Temperature  
Non-Operating Temperature  
Overtemp Shutdown  
-
-40 °C  
-55 °C  
-
85 °C  
125 °C  
-
-
120 °C  
10 °C hysteresis measured on Q4  
Dimensions  
Inches (L × W × H)  
Millimeters (L × W × H)  
Protection Features  
Short circuit  
2.28 x 1.45 x 1.00  
57.9 x 36.8 x 25.4  
Latching  
Over current  
Undervoltage  
Overvoltage  
110% to 125% max Io  
UVLO Vin < 35.0  
OVSD Vin>57.0  
Remote On/Off  
Active Low  
0 V  
-
0.4 V  
(Optional Active High)  
Turn on delay  
Outupt voltage rise time  
Safety Agency Approvals  
(pending)  
1.0 V  
-
-
-
18 V  
-
-
2.7 ms  
4.3 ms  
UL / cUL Recognized Certified to EN60950  
Derating @ 54VDC Input  
Derating @ 38VDC Input  
35  
30  
25  
20  
15  
10  
5
40  
35  
30  
25  
20  
15  
200LFM  
200LFM  
100LFM  
100LFM  
Natural  
convection  
Natural  
convection  
0
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70  
Ambient Temperature C  
0
5
10 15 20 25 30 35 40 45 50 55 60 65 70  
Ambient Temperature C  
Figure 1: Measurement circuit for reflected ripple current.  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
48 VDC Input 9.3VDC/36.5 A Output, 1/4 Brick  
Thermal Images  
*>100.0˚C  
Top Side of Unit  
w/o Heatsink  
Air Flow  
100.0  
Vin:  
Iout:  
39 Vdc  
33.2 A  
Pout: 240 W  
Tamb: 22 C  
75.0  
Airflow: 200 LFM  
50.0  
*<40.0˚C  
*>100.0˚C  
Bottom Side of Unit  
Air Flow  
80.0  
Vin:  
Iout:  
39 Vdc  
33.2 A  
Pout: 240 W  
Tamb: 22 C  
Airflow: 200 LFM  
55.0  
30.0  
*<40.0˚C  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
48 VDC Input 9.3VDC/36.5 A Output, 1/4 Brick  
Thermal Images (continued)  
*>100.0˚C  
Air Flow  
55.0  
Top Side of Unit  
w/ 0.5” heatsink  
Vin:  
Iout:  
39 Vdc  
33.2 A  
40.0  
Pout: 240 W  
Tamb: 22 C  
Airflow: 200 LFM  
25.0  
*<40.0˚C  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  
ISOLATED DC/DC CONVERTERS  
48 VDC Input 9.3VDC/36.5 A Output, 1/4 Brick  
Mechanical Drawing  
Pin Connections  
Pin  
Function  
1
2
3
4
5
+ Vin  
Remote On/Off  
- Vin  
- Vout  
+ Vout  
RoHS Compliance  
These devices contain lead, as part of the solder and solder plating alloys, and thus  
can be considered RoHS compliant if used in server or telecommunications  
infrastructure equipment applications (RoHS 5).  
©2008 Bel Fuse Inc. Specifications subject to change without notice. 121808  
CORPORATE  
FAR EAST  
EUROPE  
Bel Fuse Inc.  
Bel Fuse Ltd.  
Bel Fuse Europe Ltd.  
206 Van Vorst Street  
Jersey City, NJ 07302  
Tel 201-432-0463  
Fax 201-432-9542  
www.belfuse.com  
8F/ 8 Luk Hop Street  
San Po Kong  
Kowloon, Hong Kong  
Tel 852-2328-5515  
Fax 852-2352-3706  
www.belfuse.com  
Preston Technology Management Centre  
Marsh Lane, Suite G7, Preston  
Lancashire, PR1 8UD, U.K.  
Tel 44-1772-556601  
Fax 44-1772-888366  
www.belfuse.com