1N5225B thru 1N5267B  
Vishay Semiconductors  
formerly General Semiconductor  
Zener Diodes  
Zener Voltage Range 3.0 to 75V  
Power Dissipation 500mW  
DO-204AH  
(DO-35 Glass)  
Features  
• Silicon Planar Power Zener Diodes.  
• Standard Zener voltage tolerance is ±5% with a “B” suffix.  
Other tolerances are available upon request.  
• These diodes are also available in MiniMELF case with  
the type designation ZMM5225 ... ZMM5267, SOT-23  
case with the type designation MMBZ5265 ...  
MMBZ5267 and SOD-23 case with the types  
designation MMSZ5225 ... MMSZ5267  
Mechanical Data  
Case: DO-35 Glass Case  
Weight: approx. 0.0046 oz., 0.13 g  
Packaging codes/options:  
D7/10K per 13" reel, (52mm tape), 20K/box  
D8/10K per Ammo tape (52mm tape), 20K/box  
Dimensions in inches and (millimeters)  
Maximum Ratings and Thermal Characteristics (TA = 25°C unless otherwise noted)  
Parameter  
Symbol  
Value  
Unit  
Zener Current (see Table “Characteristics”)  
Power Dissipation at Tamb = 75°C  
Thermal Resistance Junction to Ambient Air  
Maximum Junction Temperature  
PD  
RθJA  
TJ  
500(1)  
300(1)  
mW  
°C/W  
°C  
175  
Storage Temperature Range  
TS  
–65 to +175  
°C  
Note:  
(1) Valid provided that leads at a distance of 10mm from case are kept at ambient temperature.  
Document Number 88305  
22-Aug-02  
www.vishay.com  
1
1N5225B thru 1N5267B  
Vishay Semiconductors  
formerly General Semiconductor  
Electrical Characteristics (TA = 25°C unless otherwise noted) Maximum V = 1.1V at I = 200mA  
F
F
Maximum Reverse  
Leakage Current  
Maximum Zener Impedance(1)  
Typical  
Nominal Zener  
Voltage(3)  
Temperature  
at I = 0.25mA Coefficient  
Test Current  
(mA)  
Test VoltageMaximum Regulator  
(V) (mA)  
Current (2)  
ZK  
Type  
at I V (V)  
I
at I  
Z
()  
Z
()  
α
VZ (% / °C)  
I
(µA)  
V
I
ZM  
ZT  
Z
ZT  
ZT ZT  
ZK  
R
R
1N5225B  
1N5226B  
1N5227B  
1N5228B  
1N5229B  
1N5230B  
1N5231B  
1N5232B  
1N5233B  
1N5234B  
1N5235B  
1N5236B  
1N5237B  
1N5238B  
1N5239B  
1N5240B  
1N5241B  
1N5242B  
1N5243B  
1N5244B  
1N5245B  
1N5246B  
1N5247B  
1N5248B  
1N5249B  
1N5250B  
1N5251B  
1N5252B  
1N5253B  
1N5254B  
1N5255B  
1N5256B  
1N5257B  
1N5258B  
1N5259B  
1N5260B  
1N5261B  
1N5262B  
1N5263B  
1N5264B  
1N5265B  
1N5266B  
1N5267B  
3.0  
20  
29  
28  
24  
23  
22  
19  
17  
11  
7
1600  
1600  
1700  
1900  
2000  
1900  
1600  
1600  
1600  
1000  
750  
– 0.075  
–0.070  
–0.065  
–0.060  
–0.055  
±0.030  
±0.030  
+0.038  
+0.038  
+0.045  
+0.050  
+0.058  
+0.062  
+0.065  
+0.068  
+0.075  
+0.076  
+0.077  
+0.079  
+0.082  
+0.082  
+0.083  
+0.084  
+0.085  
+0.086  
+0.086  
+0.087  
+0.087  
+0.089  
+0.090  
+0.091  
+0.091  
+0.092  
+0.093  
+0.094  
+0.095  
+0.095  
+0.096  
+0.096  
+0.097  
+0.097  
+0.097  
+0.098  
50  
25  
15  
10  
1.0  
1.0  
1.0  
1.0  
1.0  
2.0  
2.0  
3.0  
3.5  
4.0  
5.0  
6.0  
6.5  
6.5  
7.0  
8.0  
8.4  
9.1  
9.9  
10  
152  
138  
126  
115  
106  
97  
3.3  
3.6  
3.9  
4.3  
4.7  
5.1  
5.6  
6.0  
6.2  
6.8  
7.5  
8.2  
8.7  
9.1  
10  
11  
20  
20  
20  
20  
20  
20  
20  
20  
20  
20  
20  
20  
20  
20  
20  
20  
20  
5.0  
5.0  
5.0  
5.0  
5.0  
5.0  
3.0  
3.0  
3.0  
3.0  
3.0  
3.0  
2.0  
1.0  
0.5  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
89  
81  
76  
7
73  
5
67  
6
500  
61  
8
500  
55  
8
600  
52  
10  
17  
22  
30  
13  
15  
16  
17  
19  
21  
23  
25  
29  
33  
35  
41  
44  
49  
58  
70  
80  
93  
105  
125  
150  
170  
185  
230  
270  
600  
50  
600  
45  
600  
41  
12  
13  
14  
15  
16  
17  
18  
19  
20  
22  
24  
25  
27  
28  
30  
33  
36  
39  
43  
47  
51  
56  
60  
62  
68  
75  
600  
38  
9.5  
9.0  
8.5  
7.8  
7.4  
7.0  
6.6  
6.2  
5.6  
5.2  
5.0  
4.6  
4.5  
4.2  
3.8  
3.4  
3.2  
3.0  
2.7  
2.5  
2.2  
2.1  
2.0  
1.8  
1.7  
600  
35  
600  
32  
600  
11  
30  
600  
12  
28  
600  
13  
27  
600  
14  
25  
600  
14  
24  
600  
15  
23  
600  
17  
21  
600  
18  
19.1  
18.2  
16.8  
16.2  
15.1  
13.8  
12.6  
11.6  
10.6  
9.7  
8.9  
600  
19  
600  
21  
600  
21  
600  
23  
700  
25  
700  
27  
800  
30  
900  
33  
1000  
1100  
1300  
1400  
1400  
1600  
1700  
36  
39  
43  
46  
47  
52  
56  
Notes:  
(1) The Zener impedance is derived from the 1 kHz AC voltage which results when an AC current having an RMS value equal to 10% of the Zener current (IZT or  
ZK) is superimposed on IZT or IZK. Zener impedance is measured at two points to insure a sharp knee on the breakdown curve and to eliminate unstable units  
I
(2) Valid provided that leads at a distance of 10 mm from case are kept at ambient temperature  
(3) Measured with device junction in thermal equilibrium  
www.vishay.com  
2
Document Number 88305  
22-Aug-02  
1N5225B thru 1N5267B  
Vishay Semiconductors  
formerly General Semiconductor  
Ratings and  
Characteristic Curves (TA = 25°C unless otherwise noted)  
D
Document Number 88305  
22-Aug-02  
www.vishay.com  
3
Legal Disclaimer Notice  
Vishay  
Disclaimer  
All product specifications and data are subject to change without notice.  
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf  
(collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein  
or in any other disclosure relating to any product.  
Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any  
information provided herein to the maximum extent permitted by law. The product specifications do not expand or  
otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed  
therein, which apply to these products.  
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this  
document or by any conduct of Vishay.  
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless  
otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such  
applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting  
from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding  
products designed for such applications.  
Product names and markings noted herein may be trademarks of their respective owners.  
Document Number: 91000  
Revision: 18-Jul-08  
www.vishay.com  
1