COMMON MODE CHOKES  
For LAN and Telecom Applications  
CMC00100  
Designed to reduce EMI and common mode noise  
Common mode attenuation from 100kHz to 500MHz  
Operating temperature 0° to 70° C  
Multiple signal lines and packaging options available  
Low profile, SMT packaging rated to withstand 225° C  
peak IR reflow temperature  
Minimum interwinding breakdown voltage of 1500 Vrms  
ELECTRICAL SPECIFICATIONS AT 25° C  
Number  
of Lines  
Common Mode Attenuation  
dB typ  
DCR  
max  
OCL  
Part Number  
µH min  
(winding  
300kHz  
x core)  
1MHz  
10MHz  
30MHz  
50MHz  
100MHz 300MHz 500MHz  
Surface Mount  
4
S555-5999-41  
S555-5999-40  
S555-5999-15  
S555-0139-01  
S555-5999-02  
S555-6400-08  
S555-2940-00  
S555-1084-00  
S555-5999-39  
S553-5999-D6  
20  
24  
-16  
-10  
-10  
-11  
-17  
-40  
-12  
-5  
-25  
-22  
-17  
-21  
-27  
-50  
-19  
-12  
-28  
-27  
-37  
-42  
-29  
-35  
-32  
-45  
-28  
-30  
-32  
-29  
-38  
-41  
-27  
-36  
-33  
-43  
-22  
-29  
-34  
-25  
-36  
-42  
-23  
-36  
-32  
-38  
-11  
-28  
-32  
-19  
-30  
-34  
-10  
-23  
-20  
-22  
-4  
-31  
-2  
0.50  
0.35  
0.30  
0.95  
0.80  
1.00  
0.20  
0.30  
0.20  
0.30  
(4 x 1)  
4
-30  
-29  
-30  
-40  
-38  
-29  
-27  
-35  
(4 x 1)  
4
38  
-15  
-9  
(2 x 2)  
4
80  
(2 x 2)  
4
140  
4700  
80  
-11  
---  
(2 x 2)  
4
(4 x 1)  
6
-20  
-20  
-10  
-12  
-12  
-11  
-4  
(2 x 3)  
8
24  
(2 x 4)  
8
350  
85  
-21  
-17  
(2 x 4)  
16  
(2 x 8)  
-37  
-2  
Through Hole  
-38  
2
0553-3965-08  
0555-3001-08  
0555-6400-06  
140  
120  
-16  
-16  
-44  
-26  
-26  
-50  
-43  
-45  
-27  
-45  
-44  
-21  
-42  
-38  
-8  
-24  
-20  
---  
-16  
-15  
---  
0.80  
0.80  
1.00  
(2 x 1)  
4
-39  
-37  
(2 x 2)  
4
4700  
(4 x 1)  
©2000 Bel Fuse Inc. Specifications subject to change without notice. 01.00  
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com  
CMC-1  
COMMON MODE CHOKES  
For LAN and Telecom Applications  
CMC00100  
SCHEMATICS  
0555-3001-08  
0553-3965-08  
8
7
1
2
4
3
1
2
6
5
3
4
S553-5999-D6  
0555-6400-06  
1
2
40  
39  
5
6
7
4
3
5
38  
36  
2
1
9
10  
6
7
35  
34  
8
33  
31  
10  
11  
12  
30  
29  
S555-0139-01  
13  
15  
28  
26  
5
4
3
6
16  
17  
25  
24  
7
8
2
1
18  
20  
23  
21  
©2000 Bel Fuse Inc. Specifications subject to change without notice. 01.00  
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com  
CMC-2  
COMMON MODE CHOKES  
For LAN and Telecom Applications  
CMC00100  
SCHEMATICS  
S555-2940-00  
S555-1084-00  
S555-5999-39  
1
2
16  
15  
1
2
16  
15  
13  
12  
4
5
14  
13  
3
4
7
8
10  
9
5
6
12  
11  
7
8
10  
9
S555-5999-02  
S555-5999-15  
S555-5999-40  
S555-5999-41  
1
8
7
6
5
1
2
8
7
2
3
4
6
5
3
4
S555-6400-08  
10  
9
1
2
7
6
4
5
©2000 Bel Fuse Inc. Specifications subject to change without notice. 01.00  
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com  
CMC-3  
COMMON MODE CHOKES  
For LAN and Telecom Applications  
CMC00100  
MECHANICALS  
0.390  
[9.91]  
max  
0553-3965-08  
0.380  
[9.65]  
max  
0.020  
[0.51]  
Sq. 0.020 ±0.002  
[0.51 ±0.05]  
0.300  
[7.62]  
0.100  
[2.54]  
0.120 ±0.020  
[3.05 ±0.05]  
0.120  
[3.05]  
4
1
2
0.200  
[5.08]  
3
Dimensions are in inches [millimeters].  
Standard dimension tolerance is ±0.005 [0.13] unless otherwise noted.  
0555-3001-08  
0.500  
0.500  
[12.70]  
[12.70]  
max  
max  
0.400  
[10.16]  
max  
0.020  
[0.51]  
0.100  
0.110  
0.020 ±0.001  
[0.51 ±0.03]  
[2.54]  
typ  
0.300  
[7.62]  
[2.79]  
Dimensions are in inches [millimeters].  
±
Standard dimension tolerance is 0.005 [0.13] unless otherwise noted.  
©2000 Bel Fuse Inc. Specifications subject to change without notice. 01.00  
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com  
CMC-4  
COMMON MODE CHOKES  
For LAN and Telecom Applications  
CMC00100  
MECHANICALS  
0.600  
[15.24]  
max  
0555-6400-06  
0.600  
[15.24]  
max  
0.400  
[10.16]  
max  
0.130  
[3.30]  
0.200  
[5.08]  
0.400  
[10.16]  
0.200 [5.08] x 2  
0.100 [2.54] x 2  
Dimensions are in inches [millimeters].  
Standard dimension tolerance is  
±0.005 [0.13] unless otherwise noted.  
0.050  
[1.27]  
0.030  
[0.76]  
+
0.020 0.002  
0.070  
[1.78] ref  
+
[0.51 0.05]  
S553-5999-D6  
0.070  
[1.78]  
0.645  
[16.38]  
0.480  
[12.19]  
R 0.015  
0.050 [1.27]  
[0.38]  
Suggested PCB Pad Layout  
1.100  
[27.94] max  
R 0.005  
[0.13]  
0.212  
[5.38] ref  
0.225  
[5.72] max  
0.004 [0.10]  
0˚ - 5˚  
0.035  
[0.89]  
0.010 - 0.015  
[0.25 - 0.38]  
0.950  
[24.13]  
0.600  
[15.24]  
Dimensions are in inches [millimeters].  
Standard dimension tolerance is ±0.005 [0.13] unless otherwise noted.  
©2000 Bel Fuse Inc. Specifications subject to change without notice. 01.00  
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com  
CMC-5  
COMMON MODE CHOKES  
For LAN and Telecom Applications  
CMC00100  
MECHANICALS  
S555-0139-01  
0.100  
[2.54]  
0.670  
[17.02]  
0.710  
[18.03]  
0.070  
[1.78]  
0.010 ±0.002  
[0.25 ±0.05]  
0.525  
[13.34]  
0.030  
[0.76]  
Suggested PCB Pad Layout  
0.795  
[20.19]  
0.030  
[0.76]  
min  
0˚- 8˚  
0.004 [1.10]  
0.002  
[0.05]  
min  
0.100  
[2.54]  
typ  
0.087  
[2.21]  
ref  
0.098  
[2.49]  
max  
0.018 ±0.002  
[0.46 ±0.05]  
Dimensions are in inches [millimeters].  
±
Standard dimension tolerance is 0.005 [0.13] unless otherwise noted.  
S555-1084-00  
S555-2940-00  
S555-5999-39  
0.500  
12.70  
max  
Suggested PCB Pad Layout  
0.285  
[7.24]  
max  
0.375  
[9.53]  
max  
0.425  
[10.80]  
0.070  
[1.78]  
0.050  
[1.27]  
0.018 ±0.002  
[0.46 ±0.05]  
0.025  
[0.64]  
0.050  
[1.27]  
0.225  
[5.72]  
max  
4˚ nom  
0.004 [1.10]  
0.035  
[0.89]  
0.003 - 0.010  
[0.08 - 0.25]  
0.350 ±0.01  
[8.89 ±0.25]  
0.008 - 0.012  
[0.20 - 0.30]  
Dimensions are in inches [millimeters].  
±
Standard dimension tolerance is 0.005 [0.13] unless otherwise noted.  
©2000 Bel Fuse Inc. Specifications subject to change without notice. 01.00  
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com  
CMC-6  
COMMON MODE CHOKES  
For LAN and Telecom Applications  
CMC00100  
MECHANICALS  
S555-5999-02  
0.100  
[2.54]  
typ  
0.410  
0.645  
[16.38]  
[10.41]  
0.040  
[1.02]  
0.110  
[2.79]  
0.580  
[14.73]  
R0.005  
[R0.13]  
0.470  
[11.94]  
Suggested PCB Pad Layout  
R0.005  
[R0.13]  
0.330  
[8.38]  
0.015  
[0.38]  
0˚- 4˚  
.004 [0.10]  
0.030 ±0.002  
[0.76 ±0.05]  
0.100  
[2.54]  
typ  
0.055 [1.40]  
0.085 [2.16]  
Dimensions are in inches [millimeters].  
Standard dimension tolerance is ±0.005 [0.13] unless otherwise noted.  
0.500  
12.70  
max  
S555-5999-15  
Suggested PCB Pad Layout  
0.285  
[7.24]  
max  
0.375  
[9.53]  
max  
0.425  
[10.80]  
0.100  
[2.54]  
0.018 ±0.002  
[0.46 ±0.05]  
0.025  
[0.64]  
1.00  
[2.54]  
0.070  
[1.78]  
0.225  
[5.72]  
max  
4˚ nom  
0.004 [1.10]  
0.035  
[0.89]  
0.300 ±0.01  
[7.62 ±0.25]  
0.008 - 0.012  
[0.20 - 0.30]  
0.003 - 0.010  
[0.08 - 0.25]  
Dimensions are in inches [millimeters].  
±
Standard dimension tolerance is 0.005 [0.13] unless otherwise noted.  
©2000 Bel Fuse Inc. Specifications subject to change without notice. 01.00  
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com  
CMC-7  
COMMON MODE CHOKES  
For LAN and Telecom Applications  
CMC00100  
MECHANICALS  
S555-5999-40  
0.300  
[7.62]  
Suggested PCB Pad Layout  
0.050  
[1.27]  
0.375 0.280  
[9.52] [7.11]  
0.425  
[10.80]  
0.070  
[1.78]  
0.050  
[1.27]  
0.025  
[0.64]  
0.020 ±0.002  
[0.51 ±0.05]  
0.004 [1.10]  
0.084  
[2.13]  
max  
0.068  
[1.73]  
ref  
Between components  
and internal leads to  
seating plane with  
0.002 [0.05] minimum  
clearance  
0˚- 5˚  
0.150 ±0.005  
[3.81 ±0.13]  
0.032  
[0.81]  
0.300  
[7.62]  
max  
S555-5999-41  
0.285  
[7.24]  
max  
0.375  
[9.52]  
max  
0.425  
[10.80]  
0.070  
[1.78]  
0.050  
[1.27]  
0.050  
[1.27]  
0.018 ±0.002  
[0.46 ±0.05]  
0.025  
[0.62]  
Suggested PCB Pad Layout  
0.003  
[0.08]  
min  
0.200  
[5.09]  
max  
4˚ nom  
.004 [0.10]  
0.150  
[3.81]  
0.008 - 0.012  
[0.20 - 0.30]  
0.035  
[0.88]  
Dimensions are in inches [millimeters].  
Standard dimension tolerance is ±0.005 [0.13] unless otherwise noted.  
©2000 Bel Fuse Inc. Specifications subject to change without notice. 01.00  
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com  
CMC-8  
COMMON MODE CHOKES  
For LAN and Telecom Applications  
CMC00100  
MECHANICALS  
0.530  
[13.46]  
max  
S555-6400-08  
0.100  
[2.54]  
0.650  
[16.51]  
max  
0.400  
[10.16]  
0.030  
[0.76]  
0.600  
[15.24]  
0.720  
[18.29]  
max  
0.390  
[9.91]  
max  
.004 [0.10]  
0.045  
[1.14]  
0.015 - 0.020  
[0.38 - 0.51]  
Dimensions are in inches [millimeters].  
Standard dimension tolerance is ±0.005 [0.13] unless otherwise noted.  
©2000 Bel Fuse Inc. Specifications subject to change without notice. 01.00  
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com  
CMC-9  
COMMON MODE CHOKES  
For LAN and Telecom Applications  
CMC00100  
COMMON MODETEST CIRCUIT  
D.U.T.  
50  
50  
HP 3577A  
Network Analyzer  
©2000 Bel Fuse Inc. Specifications subject to change without notice. 01.00  
CORPORATE  
FAR EAST  
EUROPE  
Bel Fuse Inc.  
Bel Fuse Ltd.  
Bel Fuse Europe Ltd.  
198 Van Vorst Street  
Jersey City, NJ 07302  
Tel 201-432-0463  
Fax 201-432-9542  
www.belfuse.com  
8F / 8 Luk Hop Street  
San Po Kong  
Kowloon, Hong Kong  
Tel 852-2328-5515  
Fax 852-2352-3706  
www.belfuse.com  
PrestonTechnology Management Centre  
Marsh Lane, Suite F23, Preston  
Lancashire, PR1 8UD, U.K.  
Tel 44-1772-556601  
Fax 44-1772-888366  
www.belfuse.com  
CMC-10