Battery Master Switch BMS01  
					Description  
					The BMS01 is a battery master switch designed for dangerous goods road  
					vehicles complying with international ADR regulations. Environmental  
					protection and the intrinsically safe control circuitry of the BMS01 are  
					in accordance with ADR 2015. The battery switch must be installed  
					between the battery and the vehicle’s electrical system. It is operated  
					on and off by means of a control switch in the driver’s cab, additional  
					control switches can be sited around the vehicle as required. The  
					BMS01 is a double pole device, but can be connected as 1-pole  
					version (see connection diagram).  
					An integral safety barrier permits siting of the BMS01 in hazardous  
					areas. Additional auxiliary contacts are provided for disconnection of  
					the ignition circuit, de-energisation of the alternator field winding, or a  
					controlled shutdown of the CANBUS system followed after a delay by  
					disconnection of the battery.  
					BMS01  
					Typical applications  
					Technical data  
					Utility vehicles for hazardous goods.  
					Operating data  
					Voltage rating  
					2
					DC 12 V  
					DC 24 V  
					18...32 V  
					Voltage range  
					9...16 V  
					Ordering information  
					Rated current  
					200 A / pole  
					Type number  
					BMS01 Battery Master Switch (to ADR 2015)  
					Number of poles  
					Max. overload current  
					2,400 A 1 s; 600 A 20 s  
					Power consumption of  
					electronic module  
					2
					2-pole  
					Rated voltage  
					typically 5 mA (in OFF condition)  
					Excitation current / time of  
					the bistable main relay  
					0
					1
					DC 12 V  
					DC 24 V  
					Control function: delay time between  
					auxiliary contact K13 and main contacts  
					12 V:  
					24 V:  
					typically 2.6 A / 200 ms  
					typically 1.3 A / 200 ms  
					1
					2
					5
					1 sec / ADR-compliant  
					9.5 sec / ADR-compliant  
					180 sec / version for SCRT (BlueTec) motors  
					Control circuit (EX)  
					Temperature range  
					ZELM 04 ATEX 0213X  
					Ex II (2) G [Ex ib] II C  
					Control function: low voltage monitoring  
					-40...+70 °C (-40...+158 °F)  
					0
					1
					without low voltage monitoring  
					Reverse polarity protection integral (in the event of reverse polarity  
					the master switch will disconnect  
					with low voltage monitoring and disconnection -  
					device switches off in undervoltage condition  
					with low voltage monitoring and signalisation  
					Version  
					3
					instantaneously)  
					Low voltage monitoring  
					switching thresholds:  
					hysteresis:  
					DC 12 V  
					DC 24 V  
					0
					neutral  
					11.0 V 0. 3 V 22.8 V 0.3 V  
					typically 0.25 V typically 0.5 V  
					typically 60 sec typically 60 sec  
					BMS01 -  
					2
					1
					1
					1 -  
					0
					ordering example  
					trip time:  
					Typical life  
					10,000 cycles at rated current  
					100,000 cycles without load  
					Rubber caps and mounting screws are supplied with the product.  
					Accessories (e.g. external control switch, 7-pole and 4-pole connectors) should be  
					ordered separately.  
					Protection class: housing  
					Protection class: terminals  
					IP65  
					IP54 with rubber caps  
					Vibration  
					5 g (57-200 Hz), 0.38 mm (10-57 Hz),  
					test to IEC 60068-2-6, test Fc,  
					10 frequency cycles / axis  
					Approvals  
					Authority Standard  
					Rated voltage  
					Shock  
					10 g, test to IEC 60068-2-27, test Ea  
					Corrosion  
					96 hrs 5 % salt mist,  
					test to IEC 60068-2-11, test Ka  
					TÜV  
					- ADR 2015 Teil/part 9, 9.2.2 und /  
					and 9.7.8  
					- VdTÜV-Merkblatt 5205, Ausgabe /  
					edition 03.2015  
					- IEC 60079-0:2011  
					- IEC 60079-11:2011  
					- IEC 60529:2001  
					Humidity  
					240 hrs. 95 % RH,  
					test to IEC 60068-2-78, test Cab  
					Terminals  
					battery terminals:  
					control terminals:  
					M10 terminal studs  
					AUX connectors to DIN 72 585, 7-pole  
					CRTL connectors to DIN 72 585, 2-pole  
					KBA  
					ECE Regelung Nr. 10 (E1) Rev. 4  
					DC 12 V  
					DC 24 V  
					Auxiliary contact  
					max. 10 A (circuit unprotected)  
					ZELM  
					EN60079-0:2012+A11:2013  
					EN60079-11:2012  
					DC 12 V  
					DC 24 V  
					Aux. energy output for  
					permanently energised loads  
					(e.g. tachograph)  
					max. 1 A (internally protected)  
					approx. 1,700 g  
					Mass  
					Protection Class  
					IP65  
					1615  
					www.e-t-a.de  
					1