2
					LDC240 Series  
					LDC240-12  
					LDC240-12P  
					LDC240-24  
					LDC240-24P  
					LDC240-36  
					LDC240-36P  
					LDC240-48  
					LDC240-48P  
					LDC240-72  
					LDC240-72P  
					120 - 240 VAC (110 - 345 VDC)  
					120 - 240 VAC (110 - 345 VDC)  
					120 - 240 VAC (110 - 345 VDC)  
					120 - 240 VAC (110 - 345 VDC)  
					120 - 240 VAC (110 - 345 VDC)  
					120 - 240 VAC (110 - 345 VDC)  
					120 - 240 VAC (110 - 345 VDC)  
					120 - 240 VAC (110 - 345 VDC)  
					120 - 240 VAC (110 - 345 VDC)  
					120 - 240 VAC (110 - 345 VDC)  
					12 VDC  
					12 VDC  
					24 VDC  
					24 VDC  
					36 VDC  
					36 VDC  
					48 VDC  
					48 VDC  
					72 VDC  
					72 VDC  
					15 A  
					15 A  
					10 A  
					10 A  
					7.5 A  
					7.5 A  
					5 A  
					Includes internal ORing diode  
					Includes internal ORing diode  
					Includes internal ORing diode  
					Includes internal ORing diode  
					Includes internal ORing diode  
					5 A  
					3.3 A  
					3.3 A  
					Technical parameters are typical, measured in laboratory environment at 25°C and 240 VAC / 50 Hz, at nominal values, after minimum  
					5 minutes of operation.  
					Rated, UL certified  
					Operating  
					120 – 240 VAC  
					90 - 264 VAC  
					Input AC Voltage Range  
					Input DC Voltage Range  
					Input Frequency Range  
					Rated  
					110 - 345 VDC  
					47 - 63 Hz  
					Vin = 120 VAC 2.4 A  
					Vin = 240 VAC 1.2 A  
					Input AC Current  
					LDC240-12  
					LDC240-24 / LDC240-36 /LDC240-48 /  
					LDC240-72  
					2.5 A  
					Vin = 110 VDC  
					2.6 A  
					Input DC Current  
					LDC240-12  
					1.2 A  
					Vin = 345 VDC  
					0.9 A  
					LDC240-24 / LDC240-36 / LDC240-48 /  
					LDC240-72  
					Power Factor Correction  
					Inrush Peak Current  
					Active  
					> 0.9  
					≤ 45 A  
					Touch (Leakage) Current  
					Internal Protection Fuse  
					≤ 0.6 mA  
					Not user replaceable  
					6.3 AT  
					It is strongly recommended to provide external surge  
					arresters (SPD) according to local regulations.  
					Fuse 10 AT or MCB 10 A C curve  
					Recommended External Protection  
					Output Power  
					240 W  
					LDC240-12  
					LDC240-24  
					LDC240-36  
					LDC240-48  
					LDC240-72  
					12 VDC (12 - 15 VDC)  
					24 VDC (22 - 29 VDC)  
					36 VDC (34 - 39 VDC)  
					48 VDC (45 - 55 VDC)  
					72 VDC (70 - 85 VDC)  
					Rated Voltage  
					(Adjustable Output Voltage Range)  
					tech.support@psbel.com