LDC480 Series is a single phase, extremely compact Power Supply  
with active PFC specially designed for space sensitive and demanding  
applications.  
Its compact size, high efficiency, excellent reliability together with easy  
installation makes it ideal for various industrial applications.  
LDC480 Series is Class I isolation device suitable for SELV and PELV  
circuitry (up to 48 VDC models) and is designed to be mounted on DIN  
rail and installed inside a protective enclosure.  
High efficiency and extremely compact size  
Only 56 mm width aluminum enclosure  
Active PFC  
Overload 150%  
Constant current or hiccup mode limitation, user settable  
Wide range of output voltage  
Easy parallelable for power increase  
Up to 60°C operating temperature with no derating  
Industrial Control  
Communication  
Instrumentation Equipment  
Renewable energy  
High reliability applications  
2
LDC480 Series  
LDC480-24  
120 - 240 VAC (110 - 345 VDC)  
120 - 240 VAC (110 - 345 VDC)  
120 - 240 VAC (110 - 345 VDC)  
120 - 240 VAC (110 - 345 VDC)  
120 - 240 VAC (110 - 345 VDC)  
120 - 240 VAC (110 - 345 VDC)  
120 - 240 VAC (110 - 345 VDC)  
120 - 240 VAC (110 - 345 VDC)  
24 VDC  
24 VDC  
36 VDC  
36 VDC  
48 VDC  
48 VDC  
72 VDC  
72 VDC  
20 A  
20 A  
15 A  
15 A  
10 A  
10 A  
6.7 A  
6.7 A  
LDC480-24P  
LDC480-36  
LDC480-36P  
LDC480-48  
LDC480-48P  
LDC480-72  
LDC480-72P  
Includes internal ORing diode  
Includes internal ORing diode  
Includes internal ORing diode  
Includes internal ORing diode  
Technical parameters are typical, measured in laboratory environment at 25°C and 240 VAC / 50 Hz, at nominal values, after minimum  
5 minutes of operation.  
Rated, UL certified  
Operating  
120 240 VAC  
90 - 264 VAC  
Input AC Voltage Range  
Input DC Voltage Range  
Input Frequency Range  
Rated  
110 - 345 VDC  
47 - 63 Hz  
Vin = 120 VAC  
Vin = 230 VAC  
4.8 A  
2.4 A  
Input AC Current  
Input DC Current  
Vin = 110 VDC  
Vin = 345 VDC  
4.9 A  
1.7 A  
Power Factor Correction  
Inrush Peak Current  
Active  
> 0.9  
35 A  
0.9 mA  
8 AT  
Touch (Leakage) Current  
Internal Protection Fuse  
Not user replaceable  
It is strongly recommended to provide external surge  
arresters (SPD) according to local regulations.  
Fuse 10 AT or MCB 10 A C curve  
Recommended External Protection  
Output Power  
480 W  
LDC480-24  
LDC480-36  
LDC480-48  
LDC480-72  
LDC480-24  
LDC480-36  
LDC480-48  
LDC480-72  
LDC480-24  
LDC480-36  
LDC480-48  
LDC480-72  
LDC480-24  
LDC480-36  
LDC480-48  
LDC480-72  
24 VDC (22 - 29 VDC)  
36 VDC (34 - 39 VDC)  
48 VDC (45 - 55 VDC)  
72 VDC (70 - 85 VDC)  
Rated Voltage  
(Adjustable Output Voltage Range)  
20 A  
15 A  
10 A  
6.7 A  
21 A  
16 A  
12 A  
7 A  
30 A  
20 A  
17 A  
12 A  
Continuous Current  
Overload Limit (Constant Current Mode)  
Overload Limit (Hiccup mode) (max. 5 s)  
tech.support@psbel.com  
3
LDC480 Series  
LDC480-24 / LDC480-36  
LDC480-48 / LDC480-72  
LDC480-24 / LDC480-36  
LDC480-48 / LDC480-72  
1.5%  
0.5%  
150 mVpp  
50 mVpp  
Load Regulation  
Ripple & Noise1  
Hold up Time  
25 ms  
Overload, short circuit, with constant current or hiccup mode (user settable)  
Thermal protection  
Input undervoltage lockout  
Output overvoltage  
Protections  
LDC480-24  
LDC480-36  
LDC480-48  
LDC480-72  
33 VDC  
45 VDC  
68 VDC  
100 VDC  
Output Over Voltage Protection  
Status Signals  
DC OK - green LED  
OVERLOAD - red LED  
DC OK - dry contact (NO, 24 VDC / 1 A)  
Possible for power or redundancy (with external ORing module)  
P (models) - include internal ORing circuit  
LDC480-24 / LDC480-36  
LDC480-48 / LDC480-72  
LDC480-24 / LDC480-36  
LDC480-48 / LDC480-72  
Parallel Connection2  
Efficiency  
> 93%  
> 94%  
< 36.5 W  
< 31 W  
Dissipated Power  
1
Ripple and Noise are measured with 20 MHz bandwidth, probe terminated with a 0.1μF MKP parallel capacitor.  
Pay attention, set the current limitation mode jumper on C.C. mode when connecting more units in parallel.  
2
NOTE: Power rating, losses, efficiency, ripple, thermal behaviour and start-up may change outside of the nominal rated input range.  
Contact factory for details.  
UL certified up to 50°C at 120 VAC or  
Operating Temperature  
Storage Temperature  
Derating  
- 40° to + 70°C  
- 40° to + 80°C  
- 7.6 W / °C over 50°C at 120 VAC  
- 7.2 W / °C over 60°C at 240 VAC  
up to 60°C at 240 VAC (Start-up type tested: - 40°C)3  
Humidity  
Non condensing  
5 - 95% RH  
Life Time Expectancy  
At 25°C ambient, full load  
167953 h (19.1 years)  
Overvoltage Category  
Pollution Degree  
III (EN50178)  
2 (IEC60664-1)  
Protection Class  
Class I  
Input to Output  
Input to Ground  
Output to Ground  
UL508 (certified)  
EN60950 (reference)  
EN50178 (reference)  
EN55011 (CISPR11)  
EN55022 (CISPR22)  
EN61000-3-2  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
4.2 kVDC  
2.2 kVDC  
0.75 kVDC  
Isolation Voltage  
Safety Standards & Approvals  
Class B  
Class B  
Class A  
Level 3  
Level 3  
Level 3  
Level 4  
Level 2  
Emission  
EMC Standards  
Immunity  
EN61000-4-11  
Protection Degree  
Vibration Sinusoidal  
EN60529  
IP20  
5-17.8 Hz: ±1.6 mm;  
IEC 60068-2-6  
17.8-500 Hz: 2 g 2Hours / axis (X,Y,Z)  
30 g 6 ms, 20 g 11 ms; 3 bumps / direction,  
18 bumps total  
Shock  
IEC 60068-2-27  
3
Possible with load derating.  
North America  
Asia-Pacific  
Europe, Middle East  
+1 408 785 5200  
+86 755 298 85888  
+353 61 225 977  
© 2016 Bel Power Solutions & Protection  
BCD.00757_AB  
4
LDC480 Series  
Weight  
1.1 kg  
Dimensions (W x H x D)  
Mounting Rail  
56 x 140 x 117 mm  
IEC 60715/H15/TH35-7.5(-15)  
2.5 mm²  
Connection Terminals  
Case Material  
Screw type pluggable (24 - 12 AWG)  
Aluminum  
INPUT CONNECTION  
OUTPUT CONNECTION  
Single phase:  
L = Line  
N = Neutral  
= Earth ground  
DC:  
L = + Positive DC  
N = - Negative DC  
= Earth ground  
AC/DC input  
1
2
+ = Positive DC  
- = Negative DC  
DC output (load)  
Diagnostic Output  
(dry contact, NC output OK)  
Green LED: Output OK  
3
Signaling:  
DC OK: dry contact  
NO  
COM  
4
5
6
Red LED: Overload  
Output voltage adjustment  
Selectable limitation mode  
(Hiccup mode, C.C. mode)  
7
Figure 1. Mechanical Drawing  
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
tech.support@psbel.com