Surface Mount Fuses Datasheet  
438 Series  
0603 Fast-Acting Fuse  
RoHS Pb  
HF  
Description  
The 438 Series is a 100% Lead-free, RoHS compliant and  
Halogen-free fuse series designed specifically to provide over-  
current protection to circuits that operate under high working  
ambient temperature up to 150ºC.  
The general design ensures excellent temperature stability and  
performance reliability.  
The high I²t values which is typical in the Littelfuse Ceramic Fuse  
family ensure high inrush current withstand capability.  
Features & Benefits  
OperatingTemperature from  
Conforms to EN 60127-1 and  
-55ºC to +150ºC  
EN 60127-7  
100% Lead-free, RoHS  
compliant and Halogen-free  
CE Mark indicates suitability  
for the European Market  
Suitable for both leaded  
and lead-free reflow / wave  
soldering  
UKCA Mark indicates suitability  
for the UK Market  
Additional Information  
Recognized to UL/CSA/NMX  
248-1 and UL/CSA/NMX 248-  
14  
Applications  
Handheld Electronics  
LCD Displays  
Resources  
Accessories  
Samples  
Hard Disk Drives  
SD Memory Cards  
Agency Approvals  
Battery Packs  
Agency  
Agency File Number  
Ampere Range  
E10480  
29862  
J50489122  
N/A  
0.250A – 6A  
0.250A – 6A  
0.250A - 6A  
0.250A - 6A  
0.250A - 6A  
Electrical Characteristics for Series  
% of Ampere Rating  
Ampere Rating  
OpeningTime at 25ºC  
100%  
250%  
0.25A – 6A  
0.25A – 6A  
4 Hours, Minimum  
N/A  
5 Seconds, Maximum  
Electrical Specifications by Item  
Ampere  
Rating  
(A)  
Nominal  
Nominal NominalVoltage Nominal Power  
Agency Approvals  
Amp Max.Voltage  
Code Rating (V)  
Interrupting Rating  
Resistance Melting I2t Drop At Rated  
Dissipation At  
(Ohms)2  
2.218  
1.247  
0.829  
0.466  
0.310  
0.200  
0.174  
0.1405  
0.051  
0.0324  
0.0255  
0.0205  
0.0170  
0.0115  
(A2Sec.)3  
0.0017  
0.0041  
0.0100  
0.0281  
0.0593  
0.0510  
0.0902  
0.1440  
0.1490  
0.1977  
0.2922  
0.4752  
0.6920  
0.7398  
1.3838  
Current (V)4  
0.550  
0.488  
0.486  
0.378  
0.351  
0.365  
0.368  
0.360  
0.107  
0.095  
0.093  
0.082  
0.079  
0.074  
Rated Current (W)  
0.250 .250  
0.375 .375  
0.500 .500  
0.750 .750  
1.00  
1.25  
1.50  
1.75  
2.00 002.  
2.50 02.5  
3.00 003.  
3.50 03.5  
4.00 004.  
5.00 005.  
6.00 006.  
63VDC  
63VDC  
63VDC  
63VDC  
63VDC  
63VDC  
63VDC  
63VDC  
32  
0.138  
0.183  
0.243  
0.284  
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
50A @ 63VDC  
50A @ 32VAC  
001.  
1.25  
01.5  
1.75  
0.351  
0.456  
0.552  
0.540  
0.214  
0.238  
0.279  
0.287  
0.316  
0.370  
32  
32  
32  
32  
32  
24  
50A @ 32VDC/12VAC  
50A @ 24VDC/12VAC 0.0085  
0.072  
0.432  
Notes:  
Devices designed to carry rated current for 4 hours minimum. It is recommended that devices be operated  
continuously at no more than 80% rated current. See “Temperature Re-rating Curve”for additional re-rating  
information.  
1. AC Interrupting Rating tested at rated voltage with unity power factor. DC Interrupting Rating tested at rated  
voltage with time constant < 0.8 msec.  
2. Nominal Resistance measured with < 10% rated current.  
3. Nominal Melting I²t measured at 1 msec. opening time.  
Devices designed to be mounted with marking code facing up.  
4. Nominal Voltage Drop measured at rated current after temperature has stabilized.  
© 2023 Littelfuse, Inc.  
Specifications are subject to change without notice.  
Revised: GD. 08/11/23  
1
Surface Mount Fuses Datasheet  
438 Series  
0603 Fast-Acting Fuse  
Temperature Re-rating Curve  
AverageTime Current Curves  
140  
120  
100  
80  
100  
10  
60  
1
40  
-65 -45  
-25  
-5  
15  
35  
55  
75  
95  
115 135 155  
TEMPERATURE (°C)  
0.1  
Note:  
1. Re-rating depicted in this curve is in addition to the standard re-rating of 20% for continuous operation.  
Example:  
For continuous operation at 75 degrees celsius, the fuse should be rerated as follows:  
I = (0.80)(0.85)IRAT = (0.68)IRAT  
0.01  
0.001  
0.1  
1
10  
100  
CURRENT IN AMPERES  
Soldering Parameters  
Pb – free  
assembly  
Reflow Condition  
tP  
-Temperature Min (Ts(min)  
-Temperature Max (Ts(max)  
-Time (Min to Max) (ts)  
)
150°C  
TP  
Critical Zone  
Ramp-up  
TL to TP  
Pre Heat  
)
200°C  
60 – 180 seconds  
3°C/second max.  
5°C/second max.  
217°C  
TL  
TS(max)  
tL  
Average Ramp-up Rate (LiquidusTemp (TL) to peak)  
TS(max) toTL - Ramp-up Rate  
Ramp-down  
Preheat  
-Temperature (TL) (Liquidus)  
Reflow  
TS(min)  
-Temperature (tL)  
60 – 150 seconds  
260+0/-5 °C  
tS  
PeakTemperature (TP)  
25  
Time within 5°C of actual peakTemperature (tp)  
Ramp-down Rate  
10 – 30 seconds  
6°C/second max.  
8 minutes max.  
260°C  
time to peak temperature  
(t 25ºC to peak)  
Time  
Time 25°C to peakTemperature (TP)  
Do not exceed  
Wave Soldering  
260°C, 10 seconds max.  
© 2023 Littelfuse, Inc.  
Specifications are subject to change without notice.  
2
Revised: GD. 08/11/23  
Surface Mount Fuses Datasheet  
438 Series  
0603 Fast-Acting Fuse  
Product Characteristics  
Body: Advanced Ceramic  
Moisture Resistance  
MIL-STD-202, Method 106  
Materials  
Terminations: Ag / Ni / Sn (100% Lead-free)  
Element Cover Coating: Lead-free Glass  
Thermal Shock  
Mechanical Shock  
Vibration  
MIL-STD-202, Method 107, Condition B-3  
MIL-STD-202, Method 213, Condition A  
MIL-STD-202, Method 201  
Moisture Sensitivity  
Level  
IPC/JEDEC J-STD-020, Level 1  
Solderability  
IPC/EIC/JEDEC J-STD-002, Condition B  
MIL-STD-202, Method 103, Conditions D  
MIL-STD-202, Method 210, Condition B  
Vibration, High  
Frequency  
Dissolution of  
Metallization  
MIL-STD-202, Method 204, Condition D  
Humidity  
Resistance to Solder  
Heat  
IPC/EIC/JEDEC J-STD-002, Condition D  
IEC 60127-4  
Terminal Strength  
Dimensions mm [in]  
Part Marking System  
0.530 +/- 0.150  
[0.021 +/- 0.006]  
Amp Code  
Marking Code  
Amp Code  
Marking Code  
1.582 +/- 0.152  
[0.062 +/- 0.006]  
.250  
.375  
.500  
.750  
001.  
1.25  
01.5  
1.75  
D
E
F
002.  
02.5  
003.  
03.5  
004.  
005.  
006.  
N
O
P
0.828 +/- 0.152  
[0.033 +/- 0.006]  
G
H
J
R
S
T
K
L
U
0.516 +/- 0.064  
[0.020 +/- 0.003]  
Part Numbering System  
0438 005. W  
R
SERIES  
0.432 +/- 0.150  
[0.017 +/- 0.006]  
PACKING CODE  
R = Reel Pack  
AMP CODE  
0.60  
[0.024]  
0.74  
[0.029]  
QUANTITY CODE  
W = 3000 pcs  
1.00  
[0.039]  
Packaging  
Packaging  
Option  
8mmTape  
Packaging  
Quantity &  
Packaging Code  
Quantity  
1.94  
[0.076]  
Specification  
EIA-481, IEC  
60286-3  
3000  
WR  
and Reel  
Disclaimer Notice - Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications,  
devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth  
in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable  
for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and  
Conditions of Sale, unless otherwise agreed by Littelfuse. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own  
applications. Littelfuse products are not designed for, and may not be used in, all applications. Read complete Disclaimer Notice at www.littelfuse.com/disclaimer-electronics.  
© 2023 Littelfuse, Inc.  
Specifications are subject to change without notice.  
3
Revised: GD. 08/11/23