3
MAP80 Series
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
90
175
135
264
Continuous input range
VAC
Hz
AC input
47
90
20
63
Lowest AC input voltage that regulation is maintained with full rated
loads.
VAC
ms
Nominal AC input voltage (115VAC), full rated load.
90 VAC (80 W load)
110VAC (80W load)
2.5
1.8
Input Current
ARMS
Input Protection
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor, Vin = 264 VAC (one cycle), 25° C
Switching frequency of power supply (varies with load)
Inrush Surge Current
Operating Frequency
45
APK
22
120
kHz
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Full load @ 115 VAC.
Varies with distribution of loads among outputs.
Efficiency
73% typical
MAP80-1012
MAP80-1024
All multiple output models, main channel only
0.42
0.21
1.50
Minimum Loads
Ripple and Noise
Output Power
A
Full load, 20 MHz bandwidth.
See Model Selection Chart
Continuous output power, all multiple output models.
Peak output power (60 s maximum, 10% duty cycle), all multiple
output models.
80
90
W
%
Overshoot / Undershoot
Regulation
Output voltage overshoot/undershoot at turn-on, V1, V2.
1
Varies by output. Total regulation includes: line changes from
90-132 VAC or 175-264, changes in load starting at 20% load and
changing to 100% load.
See Model Selection Chart
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output of multiple output
units).
μs
Transient Response
500
Turn-on Delay
Time required for initial output voltage stabilization.
1
5
s
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
20
ms
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Provided on the main output of multiple output units.
5.5
17.5
32
6.8
23
37
Overvoltage Protection
MAP80-1012
MAP80-1024
V
Fully protected against output overload and short circuit. Automatic
recovery upon removal of overload condition.
Overload Protection
Logic LO (denotes power fail detected).
0.7
94
V
Logic HI with internal pull-up to output.
5.1
kΩ
Power Fail Warning 8
Power Fail trip point, maximum load, decreasing line.
Time before regulation dropout, at full load, due to loss of input power.
86
4
VAC
ms
8 Power Fail Warning is not available for MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum