defining a degree of excellence  
					8 TAP LEADING EDGE CONTROL  
					100K ECL DELAY MODULES  
					-
					Cat 42 R0  
					1.30 Max  
					3
					4
					5
					8
					9 10 11 12  
					.010 Min  
					Vee 18  
					In 24  
					.375 Max  
					*
					*
					.012  
					.008  
					Vcc 1, 6,  
					7, 13, 19  
					.12 Min  
					.018  
					.50  
					.045  
					+
					.20  
					.90  
					.40 .02  
					(
					)
					bel DC  
					.50 Max  
					(
					)
					P/N  
					.50  
					.10  
					Part Numbers  
					Test Conditions @ 25oC  
					Total  
					Delay  
					Delay  
					per Tap  
					Rise  
					Time  
					Ein  
					Pulse Voltage, Logic 1  
					Pulse Voltage, Logic 0  
					Rise Time  
					Pulse Width  
					Pulse Period  
					-0.9 Volts  
					-1.7 Volts  
					1.0 ns (20%-80%)  
					Total Delay + 10 ns  
					4 x Pulse Width  
					Thru-Hole  
					0461-0016-01  
					0461-0020-01  
					0461-0024-01  
					0461-0028-01  
					0461-0032-01  
					0461-0036-01  
					0461-0040-01  
					0461-0044-01  
					0461-0048-01  
					0461-0052-01  
					0461-0056-01  
					0461-0060-01  
					0461-0064-01  
					0461-0068-01  
					0461-0072-01  
					0461-0076-01  
					0461-0080-01  
					16 ns  
					20 ns  
					24 ns  
					28 ns  
					32 ns  
					36 ns  
					40 ns  
					44 ns  
					48 ns  
					52 ns  
					56 ns  
					60 ns  
					64 ns  
					68 ns  
					72 ns  
					76 ns  
					80 ns  
					2.0 ns  
					2.5 ns  
					3.0 ns  
					3.5 ns  
					4.0 ns  
					4.5 ns  
					5.0 ns  
					5.5 ns  
					6.0 ns  
					6.5 ns  
					7.0 ns  
					7.5 ns  
					8.0 ns  
					8.5 ns  
					9.0 ns  
					9.5 ns  
					10.0 ns  
					3 ns  
					3 ns  
					3 ns  
					3 ns  
					3 ns  
					3 ns  
					3 ns  
					3 ns  
					3 ns  
					3 ns  
					3 ns  
					4 ns  
					4 ns  
					4 ns  
					4 ns  
					4 ns  
					4 ns  
					Trin  
					PW  
					PP  
					Vee  
					Supply Voltage  
					-5.0 Volts  
					Electrical Characteristics  
					Min. Max.  
					-4.2 -5.7  
					-1165 -870  
					-1830 -1475  
					-1025 -870  
					-1830 -1620  
					240  
					Units  
					Vee Supply Voltage  
					V
					mV  
					mV  
					mV  
					mV  
					ua  
					ua  
					C
					Vih Logic 1 Input Voltage  
					Vil Logic 0 Input Voltage  
					Voh Logic 1 Output Voltage  
					Vol Logic 0 Output voltage  
					Iih Logic 1 Input Current  
					Iil  
					Logic 0 Input Current  
					0.50  
					0o  
					70o  
					Ta Operating Free Air Temperature  
					PW Min. Input Pulse Width of Total Delay  
					d
					%
					%
					40  
					Maximum Duty Cycle  
					50  
					300 PPM/OC Typ.  
					(
					)
					Tc Temp. Coeff. of Total Delay TD  
					Tolerances  
					Notes  
					Epoxy encapsulated  
					Compatible with 100K ECL circuits  
					Performance warranty is limited to specified parameters listed  
					+
					Input to Taps 1 ns or 4% , Whichever is Greater  
					Delays measured @ 50% levels on Leading Edge only  
					+
					with outputs terminated in 50 ohm 1% to -2 V  
					Rise Times measured from 20% to 80% levels  
					Other Delays and Tolerances Available  
					Consult Sales  
					Drive Capabilities  
					Fan-out capabilities  
					70 ECL Loads Max.  
					Specifications subject to change without notice.  
					Corporate Office  
					Bel Fuse Inc.  
					Far East Office  
					Bel Fuse Ltd.  
					European Office  
					Bel Fuse Europe Ltd.  
					198 Van Vorst Street, Jersey City, NJ 07302-4496  
					Tel: 201-432-0463  
					Fax: 201-432-9542  
					E-Mail: BelFuse@belfuse.com  
					Internet: http://www.belfuse.com  
					8F/8 Luk Hop Street  
					San Po Kong  
					Kowloon, Hong Kong  
					Tel: 852-2328-5515  
					Fax: 852-2352-3706  
					Preston Technology Management Centre  
					Marsh Lane, Preston PR1 8UD  
					Lancashire, U.K.  
					Tel: 44-1772-556601  
					Fax: 44-1772-888366  
					29