ADSL Magnetics
TM02389
•
•
•
Minimum interwinding breakdown voltage of 1000 Vdc
Operating and storage temperature range: -40° to +85° C
Meets IEC 695, 2-2 flammability requirements
•
•
PWB Process Capability: standard printed wiring board
assembly techniques, total-immersion cleaning
Reliability testing: shock, vibration, temperature cycling,
temperature - humidity - bias
ELECTRICAL SPECIFICATIONS AT 25° C
DCR
Ω
max
Turns Ratio
±2%
Inductance1
mH ±4%
Inductance
mH ±4%
Part Number
(1-4) : (2-5)
(1-5)
at 300 mA DC
(1-4)
(2-5)
0560-6100-A2
1 : 1
10
10
6.5
6.5
All measurements are made with pins 2 and 4 connected
1. Inductance measured at 10 kHz, 0.1 Vac
SCHEMATIC
0560-6100-A2
2
1
4
5
©2002 Bel Fuse Inc. Specifications subject to change without notice. 01.02
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com