SAW Bandpass Filter 201126B
3. Specifications
Fo = 70.0 MHz
Terminating source impedance : 50Ω and matching network
Terminating load impedance
: 50Ω and matching network
Minimum
Typical
70.0
21.0
5.95
6.3
Maximum
Center Frequency
MHz
dB
69.94
70.06
Insertion Loss
-
-
23.0
1dB Bandwidth
MHz
MHz
MHz
dB
-
-
3dB Bandwidth
6.0
-
40dB Bandwidth
7.75
0.7
8.0
1.0
200
-
Amplitude Ripple (Fo +/- 2.7 MHz)
-
Group Delay Variation (Fo +/- 2.7 MHz)
Absolute Delay
nsec
usec
-
100
2.77
52
-
Ultimate Rejection
dB
50
-
-
Temperature Coefficient of Frequency
ppm/°C
-94
-
Notes :
1) All specifications are based on the matching schematic shown below
2) All specifications are measured by Agilent Network analyzer and full 2 port calibration at room temperature
3) All attenuation measurements are measured relative to insertion loss
I T F Co., Ltd.
Part No.
Rev. Date
Rev.
201126B
102-901, Bucheon Technopark 364,
Samjeong-Dong, Ojeong-Gu, Bucheon-City,
Gyounggi-Do, Korea 421-809
2004-04-28
2/5
NI1014-CS03