SAW Bandpass Filter 230051B
3. Specifications
Fo = 71.0MHz
Terminating source impedance : 50Ω and matching network
Terminating load impedance
: 50Ω and matching network
Operating temperature range : -20 to +80℃
Minimum
Typical
71.0
6.85
0.32
0.35
0.38
0.56
0.72
0.81
0.35
200
Maximum
Center Frequency at 2dB Bandwidth
MHz
dB
70.97
71.03
8.0
-
Insertion Loss(4)
-
2dB Bandwidth
MHz
MHz
MHz
MHz
MHz
MHz
dB
0.18
3dB Bandwidth
0.22
-
5dB Bandwidth
-
-
-
-
-
-
0.5
0.7
1.0
1.4
1.0
1500
20dB Bandwidth
30dB Bandwidth
35dB Bandwidth
Amplitude Ripple (Fo +/- 0.08 MHz)
Group Delay Variation (Fo +/- 0.05 MHz)
Absolute Delay
nsec
usec
2.65
47
Ultimate Rejection(5)
Temperature Coefficient of Frequency
dB
40
-
-
-
ppm/°C2
-0.03
Notes :
1) All specifications are based on the matching schematic shown below, measured by Agilent Network analyzer and
full 2 port calibration.
2) Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing
tolerances
3) All attenuation measurements are measured relative to insertion loss
4) Insertion Loss is minimum loss within passband at ambient temperature with matching network
5) from 10 MHz to 68.5 MHz and from 73.5 MHz to 130 MHz
I T F Co., Ltd.
Part No.
Rev. Date
Rev.
230051B
102-901, Bucheon Technopark 364,
Samjeong-Dong, Ojeong-Gu, Bucheon-City,
Gyounggi-Do, Korea 421-809
2006-09-21
2/5
DS4046- CS03